• Title/Summary/Keyword: Teflon

Search Result 527, Processing Time 0.027 seconds

Surgical Analysis of the Postinfarction Ventricular Septal Defect (심근 경색에 합병된 심실중격결손의 외과적 고찰)

  • 조유원;이현우
    • Journal of Chest Surgery
    • /
    • v.29 no.1
    • /
    • pp.32-37
    • /
    • 1996
  • Between May 1991 and September 1995, 7 patients underwent surgical repair of ventricular septal defect (VSD) complicated with myocardial infarction in Asan Medical Center. The patients included two male and five female. The ages of patients were ranged from 54 years to 76 years with a mean of 65 years. The sites of postinfarction ventricular septal defect were consist of anterior septal defect in 6 patients and anteroposterior septal defect in 1 patient. Preoperative 2D-echocardiography & angiography were performed in all patients in order to measure ventricular function and evaluate the extent of coronary artery disease. The operations were delayed till mean 24 $\pm$ 12days after myocardial infarction. All patients underwent infarctectomy and Teflon patch closures through the area of the left ventricle infarction or aneurysm in the anterior or apical aspect of postinfarction ventricular septal defect. The ventricular septal defect repaired simultaneously with coronary artery b pass graft in 3 patients, with ventricular aneurysmectomy in 5 patients, and with left ventricular thrombectomy in 1 patient. Patch fixation in the left side of interventricular septum by tracts-septal interrupted pledget suture reduced the recurrence rate of VSD. There were 2 postoperative complications : One with pneumonia, 1 patient with the skin necrosis of left thigh. There was ilo early death. The 6 patients except for one emigrant were followed up postoperatively between 3 and 63 months(mean .28 months), without any sequelae and late death. They are in New York Heart Association functional class I-II.

  • PDF

Effect of electrode coating and applied voltage of pulsed electric fields (PEF) on sludge solubilization (펄스전기장 (Pulsed Electric Fields)의 전극 코팅과 인가 전압에 따른 슬러지의 가용화 효과)

  • Um, Se-Eun;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.16-23
    • /
    • 2018
  • Alternative technologies for sludge treatment and disposal need to be developed urgently because the amount of produced production has increased continuously. In this study, Pulsed Electric Fields (PEF) technique was applied for sludge solubilization and the performance was evaluated. The PEF equipped with electrodes coated by epoxy resin and teflon was inducted to the activated sludge suspension, and the effect of the coating materials on the solubilization was determined. In addition, the effect of the applied voltage on the solubilization yield was investigated as the applied voltage was increased from 6 to 12 and 15 kV. Sludge solubilization was not observed when the epoxy-coated electrode was used for PEF induction regardless of the applied voltage. However, sludge solubilization occurred when 12 and 15 kV were applied to the teflon-coated electrodes. The MLSS decreased to 9%, and the soluble-COD increased to 496% when the applied voltage was 15 kV. But sludge solubilization did not happen under 6 kV condition. The corona discharge was observed at applied voltages of 12 and 15 kV, (Ed- sorry but I cannot understand the following highlight) but if 6 kV, strongly indicating that the corona discharge make the sludge solubilized, which suggests that the critical voltage for sludge solubilization lies between 6 and 12 kV. Consequently, proper selection of electrode-coating materials and the applied voltage of PEF could lead to sludge solubilization by corona discharge.

Sulfonated Polystyrene/PTFE Composite Membranes for Direct Methanol Fuel Cell (직접 메탄올 연료전지를 위한 술폰화 폴리스티렌/테플론 복합막 제조 및 특성연구)

  • 김정훈;신정필;박인준;이수복;서동학
    • Membrane Journal
    • /
    • v.14 no.2
    • /
    • pp.173-184
    • /
    • 2004
  • For the application of direct methanol fuel cell (DMFC), sulfonated polystyrene/teflon (PS/PTFE) composite membranes were developed by changing monomer ratio of styrene and DVB. The composite membranes were prepared as follows: first, the monomer mixtures consisting of styrene, divinyl benzene and AIBN were impregnated in porous PTFE film and then, polymerized under 8$0^{\circ}C$ to give PS/PTFE membranes. Finally, the membranes were reacted with chlorosulfonic acid in 1,2-dichloroethane to give the sulfonated composite membranes. The measurements of ATR-FTIR, SEM, solvent uptake test and ion exchange capacity (IEC) were done for the resulting membranes before or after sulfonation, respectively, which showed the composite membranes with proper crosslinking degree and sulfonic acid content were prepared well as a function of styrene/DVB ratio. ion conductivity and methanol permeability were studied for the sulfonated membranes. It was found that with decreasing the ratio of styrene/DVB, methanol permeability decreased from $6.6{\times}10^{-7}∼1.3{\timas}10^{-7}$ $\textrm{cm}^2$/s, which are much lower values than that of Nafion$^{(R)}$117($1.02{\times}10^{-6}$ $\textrm{cm}^2$/s). Under the same monomer condition, ion conductivity decreased from 0.11 S/cm ($25^{\circ}C$) to 0.08 S/cm ($25^{\circ}C$), which are similar or a little higher values compared with $Nafion^{(R)}117 (1.02{\times}10^{-6}$ $\textrm{cm}^2$/s, 0.0824 S/cm). These two results confirmed the composite membranes prepared could be applied successfully to DMFC.C.

Characterization of Fluorocarbon Thin Films deposited by PECVD (PECVD로 증착된 불화 유기박막의 특성 평가)

  • 김준성;김태곤;박진구;신형재
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.8 no.2
    • /
    • pp.31-36
    • /
    • 2001
  • Teflon-like fluorocarbon thin film was deposited by using difluoromethane$(CH_2F_2$) added with Ar, $O_2$, and $CH_4$ on Si, $SiO_2$, TEOS, and Al substrate. The deposited thin film was characterized by static contact angles for measuring hydrophobicity in various additive gas ratio. temperature, and working pressure. In case of addition with Ar, the static contact angles decreased as additive gas ratio and power increased. But the static contact angles increased as working pressure increased. Specially, super-hydrophobic surface was obtained using the powder-like fluorocarbon thin film above 2 Torr. Added with $O_2$, the static contact angles decreased as the $O_2$ ratio and working pressure increased. And the static contact angles did not change in 100W, but hydrophilic surface was obtained at 200W. In case of addition of CE$_4$, static contact angles dramatically increased in $CH_4/CH_2F_2$ ratio 5. And continuous static contact angles obtained above ratio 5. As compare with previous experiments by thermal evaporation, the fluorocarbon thin film by plasma polymerization was obtained very low hysteresis. This results shows more homogenous surface by plasma polymerization than thermal evaporation process.

  • PDF

Shape Oscillation and Detachment of Droplet on Vibrating Flat Surface (진동하는 평판 위의 액적의 형상 진동 및 제거 조건에 대한 연구)

  • Shin, Young-Sub;Lim, Hee-Chang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.4
    • /
    • pp.337-346
    • /
    • 2014
  • This study aimed to understand the mode characteristics of a droplet subject to periodic forced vibration and the detachment of a droplet placed on a plate surface. An surface was coated with Teflon to clearly observe the behavior of a droplet. The contact angle between the droplet and surface and the hysteresis were found to be approximately $115^{\circ}C$ and within $25^{\circ}C$, respectively. The coating process was performed in a clean room that had an environment with a low level of contaminants and impurities such as air dust, detergents, and particles. To predict the resonance frequency of a droplet, theoretical and experimental approaches were applied. Two high-speed cameras were configured to acquire side and top views and thus capture different characteristics of a droplet: the mode shape, the detachment, the separated secondary droplet, and the waggling motion. A comparison of the theoretical and experimental results shows no more than 18 discrepancies when predicting the resonance frequency. These differences seem to be caused by contact line friction, nonlinear wall adhesion, and the uncertainty of the experiment. For lower energy inputs, the contact line of the droplet was pinned and the oscillation pattern was axisymmetric. However, the contact line of the droplet was de-pinned as the oscillation became more vigorous with increased energy input. The size of each lobe at the resonance frequency is somewhat larger than that at the neighboring frequency. A droplet in mode 2, one of the primary mode frequencies, exhibits vertical periodic movement as well as detachment and secondary ejection from the main droplet.

GENE EXPRESSION PROFILING IN HUMAN DENTAL PULP CELLS TREATED WITH MINERAL TRIOXIDE AGGREGATE (Mineral trioxide aggregate가 인간치수세포에서 유전자 발현에 미치는 영향)

  • Kim, Yong-Beom;Shon, Won-Jun;Lee, Woo-Cheol;Kum, Kee-Yeon;Baek, Seung-Ho;Bae, Kwang-Shik
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.3
    • /
    • pp.152-163
    • /
    • 2010
  • This study investigated the changes in gene expression when mineral trioxide aggregate (MTA) was applied in vitro to human dental pulp cells (HDPCs). MTA in a teflon tube (diameter 10 mm, height 2 mm) was applied to HDPCs. Empty tube-applied HDPCs were used as negative control. For microarray analysis, total RNA was extracted at 6, 24, and 72 hrs after MTA application. The results were confirmed selectively by performing reverse transcriptase polymerase chain reaction for genes that showed changes of more than two-fold or less than half. Of the 24,546 genes, 109 genes were up-regulated greater than twofold (e.g., FOSB, THBS1, BHLHB2, EDN1, IL11, FN1, COL10A1, and TUFT1) and 69 genes were down-regulated below 50% (e.g., SMAD6 and DCN). These results suggest that MTA, rather than being a bio-inert material, may have potential to affect the proliferation and differentiation of pulp cells in various ways.

Effect of Zircon on Rare-Earth Element Determination of Granitoids by ICP-MS (ICP-MS를 이용한 화강암내 희토류원소 분석시 저어콘이 미치는 영향)

  • Lee, Seung-Gu;Kim, Taehoon;Han, Seunghee;Kim, Hyeon Cheol;Lee, Hyo Min;Tanaka, Tsuyoshi;Lee, Seung Ryeol;Lee, Jong Ik
    • The Journal of the Petrological Society of Korea
    • /
    • v.23 no.4
    • /
    • pp.337-349
    • /
    • 2014
  • We measured rare earth element and Zr concentrations of USGS granite standard material GSP-2 and GSJ granite standard material JG-1a to clarify the effect of zircon during rare earth element analysis using ICP-MS. We also measured rare-earth element and zirconium (Zr) contents of zircon from granite by acid-digestion methods using conventional teflon vial and pressure-bomb. The results show that acid-digestion using teflon vial dissolved ca. 50% of zircon compared to pressure-bomb method. The Zr contents of JG-1a and GSP-2 gave ca 50% of reference value. However, rare-earth element abundance of JG-1a and GSP-2 were similar to those of reference values. This suggests that the decomposition degree of zircon might give a negligible effect on a petrological and geochemical interpretation using chondritenormalized REE pattern.

Effect of UV Sterilization on Quality of Centrifuged Takju during Storage (자외선 살균이 청징 탁주의 저장 중 품질에 미치는 효과)

  • Choi, Eun-Ju;Jung, Jin-Joo;Lee, Jang-Woon;Kang, Sung-Tae
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.3
    • /
    • pp.461-466
    • /
    • 2010
  • A cylindrical UV sterilization system was developed to decrease microorganisms in centrifuged Takju (CT). CT was run through 110 strips of honey comb type-teflon tubes and 9 UV lamps (1395 W) were equipped between teflon tubes. The optimum sterilization condition of CT was fixed for 1.5 min at 2 L/min in overall quality aspects; also, 5~6 log cycle decrease of viable cell numbers of total bacteria and yeast was observed at this operating condition. Quality changes of UV-sterilized CT were examined by UV irradiation of CT followed by storing at $30^{\circ}C$ for 8 days. To evaluate quality changes of UV-sterilized CT, pH, amino nitrogen content, acidity, reducing sugar content and viable cell numbers of total bacteria and yeast were measured. The growth of yeast and bacteria was retarded, showing around $10^8\;CFU/mL$ even after 4 days and $10^8\;CFU/mL$ after 6 days, respectively. Also, UV sterilized CT showed no changes in pH, titratable acidity, and amino nitrogen content during storage except reducing sugar content. UV sterilization did not cause significant difference in L, a, and b values between CT and UV-sterilized CT over the storage period.

EXPERIMENTAL STUDIES ON THE EFFECT OF RLN ANASTOMOSIS REMOVAL ON PHONATION (반회신경 문합과 후윤상피열근 절제가 발성기능에 미치는 영향에 대한 실험적 연구)

  • 김영모;이영구;이정식;이준열;김광문;김기령;홍원표;최홍식
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1991.06a
    • /
    • pp.11-12
    • /
    • 1991
  • 편측 성대마비의 음성개선을 위하여 현재까지 알려진 치료방법은 teflon 또는 silicone 주입술, 외과적 성대 내전술, 갑상연골 성형술, 신경재식술, 등이 있으며, 근래까지는 Teflon 또는 Gelform 주입술이 제일 효과적인 방법이라 알려져 있으나, 이는 음의 높낮이 조절능력의 한계가 있고, 신경재식술의 결과 역시 만족스럽지 못한 경우가 많다. 따라서 저자는 발성기능의 생리학적인 측면에서, 보다 효과적인 음성개선의 방법을 찾기 위하여, 사람의 후두와 비교적 유사한 특성을 가진 개를 사용하여 실험을 하였다. 반회신경을 절단하여 편측 성대 마비를 유발한 뒤, 동측의 유일한 외전근인 후윤상피열근을 절제후 절단된 신경을 문합하여, 성대의 외전근 작용의 소실과, 발성시에 주로 작용하는 내전근만의 작용을 유도하여, 공동운동의 차단과, 내전운동의 향상을 기대하였다. 본 실험에 앞서, 임의적으로 신경을 자극시킬 수 있는 신경자극기와, 주위조직으로부터 신경만을 분리하여 자극할 수 있는 전극을 개발하여 사용하였으며, 또한 성대의 발성음을 임의대로 유발시킬 수 있는 생체 내 후두발성 모형(in vivo laryngeal phonation model)을 Moore(1987, 1988)등이 발표한 모형을 토대로 자체 개발하여 사용하였다. 실험은 13마리의 개를, 반회신경 절단군(3 마리), 반회신경 절단 및 후윤상피 열근 절제군(3 마리), 후윤상피열근 절제군(3 마리), 반회신경 문합 및 후윤상피 열근 절제군(4 마리)등으로 나누어 실험하였으며, 3 개월 후, 현수후두경, 후두 내시경, videolaryngoscopy, 신경자극 검사 등으로 성대의 내전운동 및 위치 변화의 관찰, 발성음의 음향분석 및 갑상피열근의 형태학적 변화를 관찰하여 다음과 같은 결과를 얻었다. 1. 반회신경 절단군과 반회 신경 절단 및 후윤상피열근 절제군은, 수술후 3 개월에 성대의 움직임이나 각도의 변화가 없었으며, 음향분석 결과 발성음이 아닌 잡음만이 포착되었다. 즉, 절단된 신경의 문합 없이 후윤상피열근 절제 만으로는 음성개선은 기대할 수 없었다. 2. 후윤상피열근 절제군에서는 수술 후 3 개월에 정상적인 성대의 내전운동이 관찰되었으며, 음향분석상 기본주파수 동요율 및 발성음의 강도는 약간의 증가를 보였다. 즉, 반회신경이 절단되지 않은 상태에서 후윤상피 열근 만을 절제하면, 발성음의 변화는 거의 없었다. 3. 반회신경을 절단후 문합하고 후윤상피열근을 절제한군 에서는 수술후 3 개월에, 성대의 정상적인 내전운동을 보였고, 음향분석상 수술직후에는 잡음만이 포착되었으나, 3 개월 후에는 잡음이 아닌 발성음을 들을 수 있었으며, 이 발성음의 기본주파수 및 강도는 수술전보다 감소되어 있었으나, 기본주파수 동요율은 증가되어 있었다. 즉 이 술식으로 인한 뚜렷한 발성음의 향상이 있었다. 이상의 결과로 미루어, 편측 신경 절단으로 인한 성대마비시, 절단된 신경을 봉합하고 성대의 유일한 외전근인 후윤상피열근을 절제하면, 공동운동의 차단과, 내향운동의 향상으로, 음성개선에 효과적이라고 사료되었으며, 이 방법이 편측 성대마비 환자의 효과적인 음성개선의 치료방법의 하나로 응용될 수 있으리라 생각된다.

  • PDF

Development of Battery-free SAW Integrated Microsensor for Real Time Simultaneous Measurement of Humidity and $CO_2$ component (습도와 $CO_2$ 농도의 실시간 동시감지를 위한 무전원 SAW 기반 집적 센서 개발)

  • Lim, Chun-Bae;Lee, Kee-Keun;Wang, Wen;Yang, Sang-Sik
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.1
    • /
    • pp.13-19
    • /
    • 2009
  • A 440MHz wireless and passive surface acoustic wave (SAW) based chemical sensor was developed on a $41^{\circ}YX\;LiNbO_3$ piezoelectric substrate for simultaneous measurement of $CO_2$ gas and relative humidity (RH) using a reflective delay line pattern as the sensor element. The reflective delay line is composed of an interdigital transducer (IDT) and several shorted grating reflectors. A Teflon AF 2400 and a hydrophilic $SiO_2$ layer were used as $CO_2$ and water vapor sensitive films. The coupling of mode (COM) modeling was conducted to determine optimal device parameters prior to fabrication. According to simulation results, the device was fabricated and then wirelessly measured using the network analyzer. The measured reflective coefficient $S_{11}$ in the time domain showed high signal/noise (S/N) ratio, small signal attenuation, and few spurious peaks. In the $CO_2$ and humidity testing, high sensitivity ($2^{\circ}/ppm$ for $CO_2$ detection and $7.45^{\circ}/%$RH for humidity sensing), good linearity and repeatability were observed in the $CO_2$ concentration ranges of $75{\sim}375ppm$ and humidity levels of $20{\sim}80%$RH. Temperature and humidity compensations were also investigated during the sensitivity evaluation process.

  • PDF