• Title/Summary/Keyword: Teflon

Search Result 527, Processing Time 0.025 seconds

Continuous Processing of Monodispersed Zirconia Powders (초음파 혼합 연속공정에 의한 단분산 지르코니아 분체의 합성)

  • Rhee, Jhun;Jo, Dong-Soo
    • Journal of the Korean Ceramic Society
    • /
    • v.29 no.12
    • /
    • pp.919-925
    • /
    • 1992
  • Continuous synthesis process for monodispersed zirconia powders with ultrasonic wave mixing was developed. Reactant solutions were flowed through a T-tube with small diameter and then mixed in a microscale with ultrasonification. Reaction and aging were followed during the mixed solution of reactants is in plug flowing through a narrow long teflon tubing. Zr(n-OC4H9)4 in ethanol and H2O in ethanol were used as reactants. From this process monodispersed, spherical, non-agglomerated, singlet hydrated zirconia powders with 0.6 $\mu\textrm{m}$ average size were obtained. Geometrical standard deviation of the particle size distribution was less than 1.2 with ultrasonic mixing, and the geometrical standard deviation was not affected by the flow rate of the reactants.

  • PDF

Design and Fabrication of Small UWB Antenna (소형 UWB 안테나 설계 및 제작)

  • Bae, Jin-Woo;Ko, Ji-Hwan;Cho, Young-Ki
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.221-224
    • /
    • 2005
  • In this paper, We have designed, fabricated and measured a stacked planar antenna for Ultra-Wideband communication. Radiation parts of the antenna have exponential curve and fed by strip feeding network. We have used the HFSS of Ansoft to simulate the antenna. It was designed to work on a substrate Teflon of thickness 1.575mm and relative permittivity 3.2. The proposed antenna covered the entire UWB band( 3.1GHz $\sim$ 10.6GHz ) for S11$\leq$l0dB. Also the proposed antenna show a good characteristics, linear phase, omni -directional pattern lot UWB applications. Besides the measured results have a reasonable agreement with the simulated results.

  • PDF

고분자 미립구를 사용한 비뇨기과, 성형외과적 주사 요법용 생체 재료 개발

  • Jo, Ui-Ri;Gang, Seon-Ung;Kim, Byeong-Su
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.591-594
    • /
    • 2003
  • In the present study, we developed a filling material composed of poly(lactic-co-glycolic) acid (PLGA) microspheres with applications in the treatment of facial wrinkle and urinary incontinence and studied the feasibility of injecting the filling materials in animal models for plastic surgical and urological applications. Former filling materials including Teflon, Silicon, and collagen have shown a few shortcomings such as inflammation reaction, particles migration or volume decrease. We injected PLGA microspheres into the subcutaneous dorsum of mice. Injected volume was constantly maintained after implanting. We hardly found either inflammation reaction or migration. This material overcomes the problems of the current filling materials and could be utilized as a new filling material for plastic surgical and urological applications.

  • PDF

Impact Characteristics for Composite with Initial Delamination (층간분리가 있는 복합재료의 충격특성)

  • Jung, Kyu-Ik;Lee, Seung-Mo;Lee, Kee-Sung;Kim, Tae-Woo
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.64-66
    • /
    • 2005
  • In order to evaluate impact characteristics for the laminates with or without delaminations, carbon fiber/epoxy laminated composite were fabricated. After trying several ways to develop delaminations within the laminates, an insertion of teflon-tape was found to be most effective. The locations for delamination was determined after several trial-and-error experiments. The low impact energy did not produce measurable difference for composites with or without delamination, which indicated the presence of impact energy threshold. The impact chacteristics for composites with the delamination were found to be different from those for composites with other type of defect including fiber failures.

  • PDF

PIV Measurements of the Pressure Driven Flow Inside a T-Shaped Microchannel Junction (T헝 마이크로채널 연결부 압력구동 유동의 PIV계측)

  • Choi Jayho;Lee In-Seop
    • Journal of the Korean Society of Visualization
    • /
    • v.1 no.1
    • /
    • pp.75-81
    • /
    • 2003
  • A custom micro-PIV optics assembly has been used to measure the flow fold inside a T-junction of a microchannel. The micro-PIV system consists of microscope objectives of various magnifications, a dichroic cube, and an 8-bit CCD camera. Fluorescent particles of diameters 620 nm have been used with a Nd:YAG laser and color filters. A programmable syringe pump with Teflon tubings were used to inject particle-seeded distilled water into the channel at flow rates of 2.0, 4.0, 6.0 mL/hr. The micro-channels are fabricated with PDMS with a silicon mold, then O$_{2}$ -ion bonded onto a slide glass. Results show differences in flow characteristics and resolution according to fluid injection rates, and magnifications, respectively. The results include PIV data with vector-to-vector distances of 2 $\mu$m with 32 pixel-square interrogation windows at 50$\%$ overlap.

  • PDF

Equilibrium investigation for dyes removal using a mixed adsorbent

  • Ravikumar, K.;Son, Young-A
    • Textile Coloration and Finishing
    • /
    • v.18 no.5 s.90
    • /
    • pp.48-52
    • /
    • 2006
  • A mixed adsorbent prepared by pyrolysing a mixture of carbon and flyash in 1:1 ratio was tested for its deceleration ability for three different classes of dyes, namely Astrazone Blue FRR(C.I. Basic Blue 69), Teflon Blue ANL(C.I. Acid Slue 125) and Verofix Red(Reactive Red 3GL). Equilibrium investigations were carried out at the optimum conditions obtained in the previous studies. The equilibrium data fitted reasonably well to both the Freundlich and Langmuir adsorption models. However the Langmuir model was more appropriate to describe the adsorption behavior of the dyes to the hybrid absorbent system compared with the Freundlich model. The mixed adsorbent cm be an low-cost alternative to activated carbons.

Kinetic modeling analysis for the decolorization of dyes using a mixed adsorbent

  • Ravikumar, K.;Son, Young-A
    • Textile Coloration and Finishing
    • /
    • v.18 no.5 s.90
    • /
    • pp.42-47
    • /
    • 2006
  • A mixed adsorbent prepared by pyrolysing a mixture of carbon and flyash in 1:1 ratio was tested for its deceleration ability for three different classes of dyes namely, Astrazone Blue FRR(Basic Blue 69), Teflon flue ANL(Acid Blue 125) and Verofix Red(Reactive Red 3GL). Kinetic analyses were carried out at the optimum conditions obtained by the author in the previous studies. The data was fitted with three kinetic model equations. The results showed that the dye uptake mechanism followed the second-order rate expression.

Surgical Treatment of Adult Patent Ductus Arteriosus (성인 동맥관개존증의 외과적 치료)

  • 김종호
    • Journal of Chest Surgery
    • /
    • v.28 no.11
    • /
    • pp.989-993
    • /
    • 1995
  • Patent ductus arteriosus in adult is frequently complicated with aneurysm, calcification and pulmonary hypertension. Therefore, surgical treatment of patent ductus arteriosus in adult has some differences from that of infants and children. We have experienced 25 cases of adult patent ductus arteriosus from July 1983 to December 1994. Mean age of the patients was 26.6 years[16-59 years . There were 12 males and 13 females. Exertional dyspnea was the most frequent clinical manifestation. Pulmonary hypertension was present in eight patients. Ligation was done in 20 cases and surgery using cardiopulmonary bypass was done in 5 cases. There was one hospital death, which had a 5x5cm sized main pulmonary artery aneurysm and was operated under cardiopulmonary bypass. Recanalization occured in one patient who received Teflon-felt supported ligation. Although one case of recannalization after ligation was present, we believed the fact that ligation was safe and simple method of operation in adult patent ductus arteriosus without calcification and aneurysm.

  • PDF

The Variation of Cooling Charateristics Due to the Weber Number of Droplet (액적의 Weber 수에 따른 냉각특성의 변화)

  • 방창훈;양창호
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.1
    • /
    • pp.33-37
    • /
    • 2003
  • The objective of the present work is to examine the variation of cooling characteristics due to the Weber number of droplet on a heated surface. The surface temperatures varied from 72.5 - $106.1^{\circ}C$ on steel and Teflon, when Weber number was 60, 180, 300. The results are as follows; In the case of the same droplet size, the initial temperature of solid increases the indepth temperature of solid more drop. In the case of the same surface temperature, Weber number increases with increasing the cooling effect of droplet. The time-average heat flux increases with increasing the initial temperature of solid and Weber number. The evaporation time decreases with increasing the initial temperature of solid and Weber number.

Investigation of Deep Drawability and Product Qualities of Ultra Thin Beryllium Copper Sheet Metal (베릴륨동 극박판의 드로잉 성형성과 품질특성 연구)

  • Park, S.S.;Hwang, K.B.;Kim, J.B.;Kim, J.H.
    • Transactions of Materials Processing
    • /
    • v.19 no.3
    • /
    • pp.179-184
    • /
    • 2010
  • The present study is focused on the deep drawability and product qualities of ultra thin beryllium copper sheet metal. The goal of this research is to investigate the limit drawing ratio in deep drawing of ultra thin beryllium copper metal. For the experiment, beryllium copper(C1720, $50{\mu}m$ in thickness) is used. Tensile test are also carried out to find out the material properties. Deep drawing experiments are carried out in Universal Testing Machine(UTM) to obtain limit drawing ratio. Deep drawing tests are carried out for various specimen sizes. Teflon film is used as a lubricant and constant blank holding force is imposed. Sheet thickness and surface hardness are measured along radial direction after deep drawing. Thickness is measured using optical microscope. For beryllium copper(C1720), the maximum LDR of 2.4 is obtained when the die shoulder radius is 20 or 30 times of sheet thickness.