• Title/Summary/Keyword: Teeth wear

Search Result 172, Processing Time 0.026 seconds

Tribological Performance of Supper-A Dental Material (치과용 재료 Supper-A의 트라이볼로지적 고찰)

  • Choi, Won-Sik;Kim, Won-Ku;Kwon, Soon-Hong;Chung, Sung-Won;Kwon, Soon-Gu;Park, Jong-Min
    • Tribology and Lubricants
    • /
    • v.23 no.6
    • /
    • pp.318-322
    • /
    • 2007
  • The wear characteristics in supre-A dental material have been investigated. The wear tests were performed by using pin-on-disk wear tester at room temperature. Vickers hardness and fracture toughness measurement of dental materials were preformed. Microscopic observations on worn surfaces of specimens were conducted by SEM. The friction coefficient of supper-A material was investigated according to weight and slinging velocity. The hardness of supper-A material was a half of the enamel of natural teeth.

An Experimental Study on Wear of Porcelain Surface to Natural Teeth and Crown Metal Alloys (자연치아 및 치과용 합금에 대한 도재표면 마모에 관한 실험적 연구)

  • Lee, Nung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.19 no.1
    • /
    • pp.47-54
    • /
    • 1981
  • Dental porcelains are widely used for restorative material because of its excellent esthetic property. But according to contact with natural teeth or metal in oral cavity, the porcelain may be worn and may effect on masticatory physiology and prosthetic function. The purpose of this experiment was to study on wear of porcelain surface which treated in different method. Using the abrasion device which was designed and constructed by myself, the different porcelain surface were abraded by gold alloy, nickel-chrome alloy and natural teeth in order to compare roughness. Results were as follows. 1. The group of porcelain abraded by gold alloy showed less surface roughness change (t=2.92, p<0.05), and the group of porcelain abraded by natural teeth had high surface roughness. change (t=6.84, p<0.05). 2. According to the method of surface treatment, the surface roughness were very significant (F=9.12, p<0.05). 3. After abrading, the porcelain surface roughness change was very significant (F=54.49, p<0.05). 4. There was no significant between surface treatment method and the kind of abrading materials. (F=1.01, p>0..05). 5. The group of natural glazing had the most smooth surface ($2.1{\pm}1.13{\mu}m$).

  • PDF

Relationship in Shape between Oral and Pharyngeal Structures and Upper Cervical Spine (구강-인두형태와 상경추부형태간의 관계)

  • 한경수;김병욱;김문규
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.4
    • /
    • pp.457-473
    • /
    • 1998
  • This study was performed to investigate the morophological and positional correlation between the upper cervical vertebra, the oral structures and the pharyngeal tissues, and the correlation of these anatomical structures with dental features, such as teeth wear area nad tooth contact status, etc. Seventy patients with temporamandibular disorders and sixty three dental students without any signs and symptoms in head and neck region were selected for this study. All they had natural dentition without any fixed and removable protheses. Teeth wear area and arch width wre measured from the upper dental cast, tooth contact status were observed by T-Scan system$^\textregistered$ and four cephaloradiograpohs were taken from four head postures, namely, natural(NHP), forward(FHP), upward(UHP), and downward head postiure(DHP). 22 cephalometric items were measured on the films and the data were processed with SAS statistical program. The result of this study were as follows : 1. In normal group, angle of cervical vertebra tangent and of between hard and soft palate were broader in female subjects than those in male subjacets, but distance from subocciput to axis, size of soft palate, and pharyngeal space width were larger in male subjects. 2. In normal group with natural head posture, the items correlated each others from the three anatomical regions were distance between first nad second vertebra in posterior part, distance from the lingual surface of lower anterior teeth to anterior surface of soft palate, and distance from the hyoid bone to third vertebra. 3. Three set of items showed significant correlation each other in the four head postures in normal group. First set was the angle between hard and soft palate and the idstance from subocciput to posterior arch of first vertebra, second set was the distance between first and second vertebra in posterior part and the teeth wear area, third set was number and force of tooth contact and length of soft palate and distance from anterior tip of hyoid bone to mandibular plane.

  • PDF

A case of oral rehabilitation in a patient with severe tooth wear and occlusal plane collapse, utilizing maxillary fixed prosthesis and mandibular implant-assisted removable partial denture (과도한 치아 마모와 교합평면 붕괴를 보이는 환자에서 상악 고정성 보철 및 하악 임플란트 보조 국소의치를 통한 구강회복 증례)

  • Jae-Hyung Ahn;Sung-Yong Kim;Seong-A Kim;Yong-Sang Lee;Keun-Woo Lee;Hee-Won Jang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.174-182
    • /
    • 2024
  • In patients with multiple missing molars, wear patterns or displacement of anterior teeth, collapsed occlusal plane, and reduction in vertical dimension may occur. Particularly, in case of a few remaining teeth on one side, a removable partial denture has biomechanical disadvantage. For this reason, an implant-assisted removable partial denture with a few implant surveyed crowns can be an alternative. In this case, due to the right mandibular posterior teeth loss, the anterior teeth were severely worn and the occlusal plane was collapsed. With minimal increasing vertical dimension, oral rehabilitation was performed using a maxillary fixed prosthesis and mandibular implant-assisted removable partial denture. As a result, functional and aesthetic clinical outcomes were obtained.

Friction of the Gold-Alloy Dental Prosthesis (치과용 금합금-보철물의 마찰특성)

  • Choi, Won-Sik
    • Tribology and Lubricants
    • /
    • v.24 no.1
    • /
    • pp.44-48
    • /
    • 2008
  • The wear characteristics of the gold alloy dental prosthesis have been investigated. The wear tests were performed by using a pin-on-disk wear tester at room temperature. Vickers hardness and fracture toughness measurement of dental materials were preformed. Microscopic observations on worn surfaces of specimens were conducted by microscope. The friction coefficient of the gold alloy dental prosthesis was investigated according to weight and slinging velocity. The hardness of the gold alloy dental prosthesis were similar and a half of the enamel of natural teeth.

In vitro wear behavior between enamel cusp and three aesthetic restorative materials: Zirconia, porcelain, and composite resin

  • Jang, Yong-Seok;Nguyen, Thuy-Duong Thi;Ko, Young-Han;Lee, Dae-Woo;Baik, Byeong Ju;Lee, Min-Ho;Bae, Tae-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.1
    • /
    • pp.7-15
    • /
    • 2019
  • PURPOSE. The aim of this study was to identify the effects of three aesthetic restorative materials on the wear between tooth and restoration by a pin-on-disk manner. MATERIALS AND METHODS. Six aesthetic restorative materials were used to prepare disk specimens for wear test, which were Lava Zirconia as zirconia group, Vintage MP and Cerabien ZR as veneering porcelain group, Gradia Direct microhybrid composite containing prepolymerized fillers, Filtek Z250 microhybrid composite containing zirconia glass and colloidal silica particles, and Filtek Z350 nanocomposite as composite resin group. Vertical loss of the worn cusp, change of the surface roughness of the restoration materials, and the surface topography were investigated after wear test under 9.8-N contact load. RESULTS. The porcelain groups (Vintage MP and Cerabien ZR) caused the largest vertical loss of teeth when compared with those of the composite resin and zirconia groups, and Filtek Z250 microhybrid composite results in the second-largest vertical loss of teeth. The surface of Filtek Z350 nanocomposite was deeply worn out, but visible wear on the surface of the zirconia and Gradia Direct microhybrid composite was not observed. When the zirconia surface was roughened by sand-blasting, vertical loss of teeth considerably increased when compared with that in the case of fine polished zirconia. CONCLUSION. It was identified that microhybrid composite resin containing a prepolymerized filler and zirconia with reduced surface roughness by polishing were the most desirable restorative materials among the tested materials to prevent the two-body wear between aesthetic restorative material and tooth.

Reattachment procedure for treatment of fractured maxillary anterior teeth: two case reports (치관부 파절편 재부착술식을 이용한 상악전치부 치관파절의 치료에 대한 2건의 증례보고)

  • Choi, Yoorina
    • The Journal of the Korean dental association
    • /
    • v.54 no.7
    • /
    • pp.492-500
    • /
    • 2016
  • Crown fractures are a common type of dental injuries and very frequently occurred on maxillary anterior teeth, area of requiring a rapid aesthetic recovery. Crown fragment reattachment is a simple and conservative method to restore the fractured teeth. The technique promotes esthetic outcomes as utilizing natural contour, shade, surface texture of teeth and gives mechanical similarity in terms of wear-resistance. Also it gives emotional positive responses to patients and requires less of chair time and costs. This case report presents two cases of crown fragment reattachments on maxillrary anterior teeth, including one complicated crown fracture and one uncomplicated crown fracture. If the fragment is available in cases of crown fractures, reattachment of fragment can be regarded as a predictable alternative. However, it is all the time important that a close conversation informing the patients about the limitations and prognoses of this treatment option.

  • PDF

Full mouth rehabilitation in osteoporosis patient with loss of teeth and excessive wear (치아 상실과 심한 마모를 보이는 골다공증 환자에서의 완전구강 회복 증례)

  • Kim, Hyun-Tack;Kim, Myung-Joo;Lim, Young-Jun;Kwon, Ho-Beom
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.63-70
    • /
    • 2022
  • Teeth wear with loss of posterior support often leads to symptoms such as irregular occlusal plane and excessive wear of anterior teeth. In such environment, establishing proper posterior support and harmonious anterior guidance and occlusal plane is recommended. In this case, the patient had excessively worn dentition with loss of posterior support, while denying surgical treatment due to her(his) history of osteoporosis, ibandronate injection, and risk of medication-related osteonecrosis of the jaw (MRONJ). To recover the vertical space needed for prosthetic restoration, full mouth rehabilitation with vertical dimension increase of remaining teeth was decided. Missing teeth in the posterior area were restored with mandibular removable partial denture. The treatment plan was determined through careful diagnosis, and every step of procedures including tooth preparation, provisional phase with the increased vertical dimension, and definitive prosthetic phase were carried out accordingly. Once the treatment was completed, the patient was satisfied functionally and esthetically. Periodic examination of oral hygiene, occlusal stability was conducted.

Wear of contemporary dental composite resin restorations: a literature review

  • Dimitrios Dionysopoulos;Olga Gerasimidou
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.2
    • /
    • pp.18.1-18.13
    • /
    • 2021
  • Composite resins are the most commonly used dental restorative materials after minimally invasive dental procedures, and they offer an aesthetically pleasing appearance. An ideal composite restorative material should have wear properties similar to those of tooth tissues. Wear refers to the damaging, gradual loss or deformation of a material at solid surfaces. Depending on the mechanism of action, wear can be categorized as abrasive, adhesive, fatigue, or corrosive. Currently used composite resins cover a wide range of materials with diverse properties, offering dental clinicians multiple choices for anterior and posterior teeth. In order to improve the mechanical properties and the resistance to wear of composite materials, many types of monomers, silane coupling agents, and reinforcing fillers have been developed. Since resistance to wear is an important factor in determining the clinical success of composite resins, the purpose of this literature review was to define what constitutes wear. The discussion focuses on factors that contribute to the extent of wear as well as to the prevention of wear. Finally, the behavior of various types of existing composite materials such as nanohybrid, flowable, and computer-assisted design/computer-assisted manufacturing materials, was investigated, along with the factors that may cause or contribute to their wear.

TREATMENT OF CLASS II DIVISION 1 MALOCCLUSION WITH L-ARS(LIGATED ANTERIOR REPOSITIONING SPLINT) (L-ARS를 이용한 Cl II div. 1 부정교합의 치험례)

  • Kim, Jong-Chul;Williamson, Eugene H.
    • The korean journal of orthodontics
    • /
    • v.23 no.4 s.43
    • /
    • pp.447-454
    • /
    • 1993
  • Patient with skeletal class II relationship was treated with L-ARS. L-ARS is fixed functional appliance that could be effective in children and adolescent patient who don't wear activator. The following results were obtained ; 1) Growth of Mandible was stimulated and overjet was decreased, therefore coupling of anterior teeth was established with L-ARS which is fixed functional appliance. 2) These changes were accomplished with Mandibular skeletal growth with no effect on the Maxilla. 3) L-ARS was especially effective on patient who deny to wear the removable functional appliance.

  • PDF