• Title/Summary/Keyword: Technology standard model

Search Result 1,649, Processing Time 0.036 seconds

Fuzzy Inference Systems Based on FCM Clustering Algorithm for Nonlinear Process (비선형 공정을 위한 FCM 클러스터링 알고리즘 기반 퍼지 추론 시스템)

  • Park, Keon-Jun;Kang, Hyung-Kil;Kim, Yong-Kab
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.5 no.4
    • /
    • pp.224-231
    • /
    • 2012
  • In this paper, we introduce a fuzzy inference systems based on fuzzy c-means clustering algorithm for fuzzy modeling of nonlinear process. Typically, the generation of fuzzy rules for nonlinear processes have the problem that the number of fuzzy rules exponentially increases. To solve this problem, the fuzzy rules of fuzzy model are generated by partitioning the input space in the scatter form using FCM clustering algorithm. The premise parameters of the fuzzy rules are determined by membership matrix by means of FCM clustering algorithm. The consequence part of the rules is expressed in the form of polynomial functions and the coefficient parameters of each rule are determined by the standard least-squares method. And lastly, we evaluate the performance and the nonlinear characteristics using the data widely used in nonlinear process.

A Study on Collecting Electrode Design for Developing Electrostatic Precipitator(ESP) of Urban Railway Underground Tunnels (도시철도 지하터널용 전기집진기 개발을 위한 집진극 형상에 대한 기초연구)

  • Koo, Tae Yong;Kim, Yong Min;Hong, Jung Hee;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.9 no.2
    • /
    • pp.79-87
    • /
    • 2013
  • In this study, the characteristics of turbulent flow and collection efficiency for an one-stage electrostatic precipitator(ESP) with slit type collecting electrode for urban railway underground tunnels were obtained using computational fluid dynamics(CFD) commercial code FLUENT 6.3 and lab-scale experiments. The electrostatic precipitator was operated under high gas velocity(3~12m/s). Five different designs of collecting electrode, flat plate-type and a slit-type of 3mm, 5mm, 7mm and 10mm slit width and four various gas velocity(3, 6, 9, and 12m/s) were used and applied. A standard k-${\varepsilon}$ model in CFD commercial code FLUENT 6.3 was used for flow simulation. The flow simulation results showed that the turbulent intensity of flat plate-type was higher than slit-type under all gas velocity conditions and also the turbulent intensity of flat plate-type was increased continuously, but in case of slit-type was maintained at constant range. And, the turbulent intensity was decreased according to increasing of slit width. The experimental results showed that the collection efficiency of slit-type was higher than flat plate-type under all gas velocity conditions. And, over 6m/s gas velocity condition, the collection efficiency of 5mm and 7mm was highest, when compared to 3mm and 10mm.

Improving Assessments of Maritime Traffic Congestion Based On Occupancy Area Density Analysis for Traffic Vessels (통항선박의 점용영역 밀집도 분석을 통한 해상교통혼잡도 평가 개선에 관한 연구)

  • Kim, Soung-Tae;Rhee, Hahn-Kyou;Gong, In-Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.2
    • /
    • pp.153-160
    • /
    • 2017
  • It may be reasonable to consider density per unit area over time rather than analyze traffic volume, which is simply the traffic volume per unit of time, in assessing the maritime traffic congestion of a certain area. This study contributes to the standardization of maritime traffic congestion assessment methods for the maritime traffic safety diagnosis institute while seeking a new method to minimize evaluation error due to converted traffic volume per ship tonnage level. To solve this problem, a method to evaluate maritime traffic congestion by comparing the area occupied by a vessel with the area of its route using vessel identification data from the Automatic Identification System (AIS) has been proposed. In this new model, it is possible to use actual data due to the development of information and communication technology, reducing conversion error while allowing for the evaluation of maritime traffic congestion by route.

A Radiation-hardened Model Design of CMOS Digital Logic Circuit for Nuclear Power Plant IC and its Total Radiation Damage Analysis (원전용 IC를 위한 CMOS 디지털 논리회로의 내방사선 모델 설계 및 누적방사선 손상 분석)

  • Lee, Min-Woong;Lee, Nam-Ho;Kim, Jong-Yeol;Cho, Seong-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.745-752
    • /
    • 2018
  • ICs(Integrated circuits) for nuclear power plant exposed to radiation environment occur malfunctions and data errors by the TID(Total ionizing dose) effects among radiation-damage phenomenons. In order to protect ICs from the TID effects, this paper proposes a radiation-hardening of the logic circuit(D-latch) which used for the data synchronization and the clock division in the ICs design. The radiation-hardening technology in the logic device(NAND) that constitutes the proposed RH(Radiation-hardened) D-latch is structurally more advantageous than the conventional technologies in that it keeps the device characteristics of the commercial process. Because of this, the unit cell based design of the RH logic device is possible, which makes it easier to design RH ICs, including digital logic circuits, and reduce the time and cost required in RH circuit design. In this paper, we design and modeling the structure of RH D-latch based on commercial $0.35{\mu}m$ CMOS process using Silvaco's TCAD 3D tool. As a result of verifying the radiation characteristics by applying the radiation-damage M&S (Modeling&Simulation) technique, we have confirmed the radiation-damage of the standard D-latch and the RH performance of the proposed D-latch by the TID effects.

A study on membrane technology for surface water treatment: Synthesis, characterization and performance test

  • Haan, Teow Yeit;Shah, Mubassir;Chun, Ho Kah;Mohammad, Abdul Wahab
    • Membrane and Water Treatment
    • /
    • v.9 no.2
    • /
    • pp.69-77
    • /
    • 2018
  • The use of membrane as an innovative technology for water treatment process has now widely been accepted and adopted to replace the conventional water treatment process in increasing fresh water production for various domestic and industrial purposes. In this study, ultrafiltration (UF) membranes with different formulation were fabricated via phase inversion method. The membranes were fabricated by varying the polymer concentration (16 wt%, 18 wt%, 20 wt%, and 21 wt%). A series of tests, such as field emission scanning electron microscope (FESEM), pore size and porosity, contact angle, and zeta potential were performed to characterize the membranes. The membrane performance in terms of permeation flux and rejection were evaluated using a laboratory bench-scale test unit with mine water, lake water and tube well as model feed solution. Long hour filtration study of the membranes provides the information on its fouling property. Few pore blocking mechanism models were proposed to examine the behaviour of flux reduction and to estimate the fouling parameters based on different degree of fouling. 21 wt% PVDF membrane with smaller membrane pore size showed an excellent performance for surface water treatment in which the treated water complied with NWQS class II standard.

A Case Study of Application of Exposure Index in Computed Radiography by Using Human Chest Phantom (인체 흉부 모형 팬텀을 이용한 컴퓨터방사선영상에서 노출지수의 적용 사례 연구)

  • Jeong, Hoi-Woun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.533-538
    • /
    • 2018
  • As the use of digital radiographic system has been expanded, there are some concerns an increase about in patient of radiation dose. Therefore, International Electro-technical Commission (IEC) has been proposed a standard foe exposure index (EI). In this study, the EI was measured on human chest model using computed radiography (CR). Radiation quality used RQA5 of IEC62494-1. After acquiring the chest anterior posterior image (Chest AP) by using the phantom, the EI was obtained by applying the system response. In this study, we have analyzed the images with the detector size (Full filed ROI) and the optimized image (Fit filed ROI). The EI increased proportionally with radiation dose increase. Due to the discrete increase in pixel value, the EI showed an exponential increase. The discrete increase in noise equivalent quanta (NEQ) resulted in a discrete increase in the EI. The EI of the two images used in this study increased with increasing NEQ but showed different increments. For the measurement of the EI, IEC standards must be followed. The EI should be used as an index to evaluate the image quality for quality control of X-ray image rather than as an indicator of exposure dose. When calculating the EI, the system response should be applied depending on whether or not the grid is used. The size of the field should be obtained by including only the necessary parts.

Analysis of the Applicability of Ground Stabilizer Using Recycled Resources as Prebored Piles (매입말뚝 주면고정액으로 순환자원을 재활용한 지반안정재의 활용 가능성 분석)

  • Seo, Se-Gwan;Song, Sang-Huwon;Cho, Dae-Sung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.3
    • /
    • pp.287-294
    • /
    • 2021
  • In this study, tests were performed to analyze the feasibility of using the ground stabilizer from recycled resources such as blast furnace slag powder as filling material of prebored piles. For this, specimens were prepared by applying 70% and 83% of the general water/binder ratio of the filling material of prebored piles. And compression test, model test, and shaking table test were performed to determine the compressive strength, skin friction on the surface between prebored pile and filling material, and seismic performance of ground stabilizer. As a result of the tests, the compressive strength exceeded the relevant domestic standards, and the skin friction was equivalent to that of ordinary portland cement. In addition, the amount of vertical and horizontal displacement caused by earthquakes was found to be much smaller than the domestic standard. Therefore, when considering the test results comprehensively, it is judged that the feasibility of using a ground stabilizer from recycled resources as filling material for prebored pile is sufficient.

A Review of Experimental Evaluation Method to Floor Environment Vibration Criteria for Semiconductor and Display Equipment (반도체·디스플레이 장비용 바닥 환경진동허용규제치의 실험적 평가방법 고찰)

  • An, Chae Hun;Choi, Jeong Hee;Park, Joon Soon;Park, Min Su
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.1
    • /
    • pp.25-31
    • /
    • 2021
  • The semiconductor and display equipment demands an ultra-fine precision of several nm to several ㎛, and the scale is getting smaller due to the explosive development. The manufacturing process equipment for such products with ultra-fine precision is very sensitive to ultra-small vibrations flowing from the floor, resulting in problems of production defects and yield degradation. The vibration criteria are a standard that regulates the vibration environment of the floor where such precision process equipment will be installed. The BBN vibration criteria defined the allowable vibration velocity level in the frequency domain with a flat and inclined line and presented a rating according to it. However, the actual vibration criteria have appeared with various magnitudes in the frequency domain according to the dynamic characteristics of individual equipment. In this study, the relationship between the relative motion of two major points in the equipment and the vibration magnitude of the floor is presented using the frequency response function of a simple 3-DOF model. It is describing the magnitudes according to the frequency of the floor vibration that guarantees the allowable relative motion and this can be used as the vibration criteria. In order to obtain the vibration criteria experimentally a method of extracting through a modal test was introduced and verified analytically. It provides vulnerable frequency and magnitude to floor vibration in consideration of the dynamic characteristics of individual equipment. And it is possible to know necessary to improve the dynamic characteristics of the equipment, and it can be used to check the vibration compatibility of the place where the equipment will be installed.

Academic Stress, Self-directed Learning Ability, Learning Satisfaction of Nursing Students Exposed to Blended Learning (블렌디드 러닝을 경험한 간호대학생의 학업스트레스, 자기주도적 학습능력 및 학습만족도)

  • Park, Eui-Jeung;Jeong, Gyeong-Sun
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.2
    • /
    • pp.145-153
    • /
    • 2022
  • Purpose : This study aimed to investigate the effects of blended learning on learning satisfaction in nursing students. Methods : This study was conducted with 160 current nursing students in the department of nursing at K university located in city B. All students included in the study understood the purpose of the study and provided informed consent to participate. Data were collected between May 3 and July 9, 2021 and analyzed using SPSS/WIN 22.0. The frequency, percentage, mean, and standard deviation were created, and t-test, ANOVA, and Scheffé test for post hoc analysis were performed. Correlations were analyzed using Pearson's correlation coefficient. The factors influencing learning satisfaction were analyzed using multiple regression. Results : Significant differences were observed for academic stress according to the online classes environmental satisfaction (F=4.10, p=.001), online classes experience (t=4.11, p=.001) and self-directed learning ability according to the grade (F=4.10, p=.001), online classes environmental satisfaction (t=4.11, p=.001). The academic stress of nursing students who experienced blended learning was significantly negatively correlated with self-directed learning ability (r=-.480, p<.001), and learning satisfaction (r=-.236, p<.001). self-directed learning ability showed a significant positive correlation with learning satisfaction (r=.524, p<.001). The regression model for the factors affecting the learning satisfaction of the subjects was statistically significant (F= 3.027, p<.001). The major influential factors of learning satisfaction were grade (𝛽=.154, p=.013), satisfaction with school life (𝛽=.168, p=.032), and satisfaction with non-contact learning environment (𝛽=-.141, p=.028). The explanatory power was 28 %. Conclusion : These results indicate that it is necessary to reduce academic stress and increase self-directed learning ability to enhance learning satisfaction in nursing students through blended learning. In addition, the development and operation of a tailored intervention program is required to help improve learning satisfaction.

A rapid and direct method for half value layer calculations for nuclear safety studies using MCNPX Monte Carlo code

  • Tekin, H.O.;ALMisned, Ghada;Issa, Shams A.M.;Zakaly, Hesham M.H.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3317-3323
    • /
    • 2022
  • Half Value Layer calculations theoretically need prior specification of linear attenuation calculations, since the HVL value is derived by dividing ln(2) by the linear attenuation coefficient. The purpose of this study was to establish a direct computational model for determining HVL, a vital parameter in nuclear radiation safety studies and shielding material design. Accordingly, a typical gamma-ray transmission setup has been modeled using MCNPX (version 2.4.0) general-purpose Monte Carlo code. The MCNPX code's INPUT file was designed with two detection locations for primary and secondary gamma-rays, as well as attenuator material between those detectors. Next, Half Value Layer values of some well-known gamma-ray shielding materials such as lead and ordinary concrete have been calculated throughout a broad gamma-ray energy range. The outcomes were then compared to data from the National Institute of Standards and Technology. The Half Value Layer values obtained from MCNPX were reported to be highly compatible with the HVL values obtained from the NIST standard database. Our results indicate that the developed INPUT file may be utilized for direct computations of Half Value Layer values for nuclear safety assessments as well as medical radiation applications. In conclusion, advanced simulation methods such as the Monte Carlo code are very powerful and useful instruments that should be considered for daily radiation safety measures. The modeled MCNPX input file will be provided to the scientific community upon reasonable request.