• 제목/요약/키워드: Technical report

검색결과 515건 처리시간 0.025초

국내공정시험기준과 ISO 방법을 이용한 고정오염원 미세먼지 (PM10, PM2.5) 측정 방법 및 입경분율 비교: 석탄화력발전소, 석유정제시설 중심으로 (Comparison of Measurement Methods and Size Fraction of Fine Particles (PM10, PM2.5) from Stationary Emission Source Using Korean Standard and ISO: Coal Power Plant and Refinery)

  • 윤종상;한세현;정용원;전기준
    • 한국대기환경학회지
    • /
    • 제33권4호
    • /
    • pp.342-350
    • /
    • 2017
  • We report mass concentration and size fraction of TPM, $PM_{10}$ and $PM_{2.5}$ according to Korea standard test method (ES 01301.1 and ES 01317.1) and ISO 23210 methods. Particulate matters were sampled in large stationary emission sources such as a coal power plant and B-C oil refinery. The Korea standard test method PM mass concentrations showed 3~3.5 times larger than the cascade impactor method. On the other hand, the size fraction results showed less than 5% difference (i.e. $PM_{2.5}/PM_{10}$) between two methods. Moreover, the correlation coefficient ($r^2$) is 0.84 between TPM results of the Korea standard test method and CleanSYS. These results suggested not only improvement of current test criteria in terms of technical and theoretical aspects. Further, additional measurements are required in various large stationary sources to compare current field data.

IMO의 선박기인 CO2 배출 규제 동향 및 고찰 (Recent International Development on the Technical and Operational Measures of IMO's CO2 Emission Control From Ships)

  • 정노택
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제14권1호
    • /
    • pp.65-71
    • /
    • 2011
  • 국제해사기구의 해양환경보호위원회에서 CO2 배출량 감축의 지구적 노력에 동참하기 위해 최근 선박에서 대기로 방출하는 CO2의 양을 지수화 하고자 하는 논의가 활발히 진행중이다. 그 대표적인 지수로서 신조선 설계 건조시에 적용하는 에너지 효율지수(EEDI : Energy Efficiency Design Index for new ships)와 현재 또는 건조 후 항행시에 운항선에 적용되는 에너지 효율지표(EEOI : Energy Efficiency Operational Indicator), 그리고 운항선의 에너지 효율관리 계획(SEEMP : Ship Energy Efficiency Management Plan)등이다. 본 지수는 선박을 설계 건조시부터 각 선박당 CO2의 배출값을 산정하고 운항시에도 CO2배출을 개량하고 이를 감축하는 방안을 모색하도록 유도하는 조치가 될 것이다. 향후 3년내에 발효될 수 있는 임박한 CO2선박 배출 규제를 조사 분석하고 향후 발전방향을 모색해 보고자 한다.

합성암반체 접근법에 대한 고찰 (Review of the Synthetic Rock Mass Approach)

  • 박철환;신중호;박의섭
    • 터널과지하공간
    • /
    • 제17권6호
    • /
    • pp.438-447
    • /
    • 2007
  • 본 기술보고서는 Lisbon에서 개최된 2007 ISRM Congress에서 발표된 논문을 소개한 것이다. 이는 SRM(합성암반체)에 관한 연구결과이며, 이의 중요성과 향후 잠재력을 강조하고 있는 Fairhurst 교수가 직접 발표한 논문이다. 절리 암반의 특성을 규명하는 SRM 접근법은 현존하는 경험적 접근법이나 절리 암반의 거동에 대한 현재의 이해정도와 관련지어 재검토된다. 이 재검토 논문에서 절리 암반의 역학적 거동에 영향을 미치는 주요 요소들이 어떻게 고려되는가를 기술하며, 또 SRM 접근법이 상당히 발전되어 현장에 적용된 사례를 보여준다. PFC-3D에서 BP 모델링과 DFN 모사법 등의 두개의 잘 정립된 방법에 기초를 두고 있는 이 기법은 새로운 미끄러지는 절리모델을 사용한다. 이 모델은 모든 응력경로에 의하여 힘을 받고 있는 수천개의 기존 절리를 포함하는 대규모 암반체를 모사할 수 있게 하는 것이다. 암반의 강도 및 취성도, 완전 순응 행렬의 전개, 그리고 초기의 파쇄 등이 SRM 시험에서 얻어지는 결과이다.

국제상호비교검증을 통한 Teledyne PB-3 개인선량계시스템의 성능시험 (The Performance Test of Teledyne PB-3 Personnel Dosimetry System by Intercomparison Study)

  • 이상윤;이형섭;김장렬;윤석철
    • Journal of Radiation Protection and Research
    • /
    • 제19권2호
    • /
    • pp.133-145
    • /
    • 1994
  • 최근, 개인방사선피폭선량평가에 관한 기술기준이 과학기술처에 의해 고시됨에 따라 국내에서도 개인선량계를 이용한 체외피폭선량평가결과의 신뢰성 문제가 크게 대두되고 있다. 한국원자력연구소에서는 이러한 국내의 상황을 인식하고 자체적인 신뢰성 확보를 위해 미국의 Oak Ridge국립연구소의 주관하에 개인피폭선량의 평가에 관한 국제상호비교검증시험(Personnel Dosimet Intercomparison Study ; PDIS)을 수행하였다. 비교검증시험에는 한국원자력연구소에서 사용하고 있는 Teledyne PB-3 열형광선량계가 사용되었으며 선량계산 알고리즘은 Teledyne PB-3 version 1.5-1989를 사용하였다. 본 연구에서는 지금까지 실시 된 PDIS의 결과를 요약하고 현재 PB-3 시스템의 개인선량평가성능에 대해 고찰하였으며, 선량평가절차에 대한 문제점 도출을 통하여 직업적 방사선피폭선량 평가능력의 향상을 위한 방안을 제시하였다.

  • PDF

프로젝션 기반의 감소현실 시스템 (Projection-Based Diminished Reality System)

  • 이승훈;박한훈;서병국;박종일
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제13권2호
    • /
    • pp.55-60
    • /
    • 2007
  • 본 논문은 프로젝터를 이용한 색상 및 기하 보정기술과 영상완성(image completion)기술을 결합하여 감소현실(diminished reality, DR)을 체험 할 수 있는 시스템을 제안한다. 감소현실은 증강현실(augmented reality)과 반대되는 개념으로 실세계에 존재하는 불필요한 객체 혹은 정보를 가상으로 은닉함으로써 사용자에게 시각적 편의를 제공하는 기술이다. 기존에 데스크탑 혹은 HMD 기반의 감소현실 기술은 개발된 사례가 있으나, 프로젝션 기반의 감소현실 기술에 대한 개발 사례는 없었다. 최근 고화질, 경량의 프로젝터의 일반화와 함께 프로젝션 기반 디스플레이의 응용분야가 크게 증가하고 있음을 감안해 볼 때, 프로젝션 기반의 감소현실 기술에 대한 요구는 크게 증가할 것이다. 본 논문에서는 프로젝션 기반의 감소현실을 구현하기 위한 기술적 과제들을 해결하고 그 응용사례를 제시함으로써 프로젝션 기반의 감소현실 시스템의 필요성 및 가능성을 제시하고자 한다.

  • PDF

Leukocyte- and platelet-rich fibrin as an adjuvant to the surgical approach for osteoradionecrosis: a case report

  • Maluf, Gustavo;Caldas, Rogerio Jardim;Fregnani, Eduardo Rodrigues;da Silva Santos, Paulo Sergio
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제46권2호
    • /
    • pp.150-154
    • /
    • 2020
  • We present a case of osteoradionecrosis treated with leukocyte- and platelet-rich fibrin (LPRF) and surgery and followed up with clinical and tomographic investigations. A 65-year-old woman presented with pain in the posterior region of the right palate. Her medical history included cardiovascular disease and squamous cell carcinoma in the anterior region of the floor of the mouth that had been treated with intensity-modulated radiation therapy. Measurements of isodose curves showed a full dosage of 6,462.6 cGy in the anterior mandibular region, whereas that in the posterior region on the right side of the maxilla reached 5,708.1 cGy. Osteotomy was performed using rotary instruments, and debridement and placement of two LPRF membranes were also carried out. New gum tissue with no bone exposure was noted 14 days postoperatively. Tissue repair was complete, and the patient had no further complaints. During a 39-month follow-up period, the oral mucosa remained intact, and the patient was rehabilitated with a new upper denture. Since there is no consensus regarding the best protocol to treat osteoradionecrosis, LPRF might be an interesting adjuvant to a surgical approach. The use of LPRF is simple and reduces operational costs, time of handling, probability of technical failure, and associated morbidities for patients with osteoradionecrosis.

선천성 기관-윤상연골 협착에서 성공적으로 시행한 활주 기관-윤상연골 성형술 (A Successful Slide Cricotracheoplasty in Congenital Cricotracheal Stenosis)

  • 허정욱;한석주;김영호;김명준;이기영;김재억;한애리;황의호
    • Advances in pediatric surgery
    • /
    • 제7권1호
    • /
    • pp.54-58
    • /
    • 2001
  • Slide tracheoplasty. as a treatment for congenital tracheal stenosis, has been recently reported to have good results and quite a number of advantages as compared with conventional tracheoplasties. The aim of this study is to report a new surgical technique modified from the slide tracheoplasty. "the slide cricotracheoplasty" for the congenital cricotracheal stenosis. A girl was born by Cesarean section and the diagnosis of esophageal atresia (Gross type C) and cricotracheal stenosis (30 % of total length of trachea) was established. Esophageal atresia was successfully corrected at the 8th day of life. At the 31st day of life, corrective surgery for congenital cricotracheal stenosis. the slide cricotracheoplasty. was performed with success. Slide cricotracheoplasty is almost the same procedure as slide tracheoplasty except for two technical features. First the cricoid cartilage was split on its anterior surface. Second the split cricoid cartilage was fixed to pre vertebral fascia to maintain enough space to accommodate the sliding caudal segment of trachea because of the stiffness of the cricoid cartilage. We believe that the sliding cricotracheoplasty is a new surgical technique for congenital cricotracheal stenosis that has similar results and advantages as the sliding tracheoplasty.

  • PDF

광학현미경 In Situ Hybridization에 의한 Viral RNA 증명 (Identification of Viral RNA by Light Microscopic in situ Hybridization)

  • 최원기;주경웅;김석홍
    • 대한의생명과학회지
    • /
    • 제2권2호
    • /
    • pp.249-255
    • /
    • 1996
  • 토끼 출혈증 바이러스에 감염된 조직을 10% 포르말린 고정, 파라핀 블록으로 보관했던 것으로 표본을 만들고 biotin 표지된 올리고뉴클레오티드 probe를 사용하는 in situ hybridization 기법으로 viral RNA를 조사하였다. in situ hybridization 기법은 핵산을 규명하는 다른 방법들에 비하여 신속하고 특이성인 높은 기법으로 모든 과정이 MicroProbe$^{TM}$ capillary action system에서 1-2시간 이내에 완료된다. Viral RNA는 간세포의 세포질과 신장의 피질에서 주로 관찰되었으나, 폐조직과 신장의 수질에서는 부분적으로 적색신호가 보였다. 비록 기술적인 한계를 가지고 있지만 다른 핵산 진단방법 보다 많은 장점을 가지고 있어 조직 병리학적으로 바이러스 진단하는데 하나의 독특한 기법으로 채용되리라 기대된다.

  • PDF

Proton Beam Dosimetry Intercomparison

  • Fukumura, Akifumi;Kanai, Tatsuaki;Kanematsu, Nobuyuki;Yusa, Ken;Maruhashi, Akira;Nohtomi, Akihiro;Nishio, Teiji;Shimbo, Munefumi;Akagi, Takashi;Yanou, Toshihiro;Fukuda, Shigekazu;Hasegawa, Takashi;Kusano, Yohsuke;Masuda, Yasutaka
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.252-254
    • /
    • 2002
  • A new protocol for dosimetry in external beam radiotherapy is published by the Japan Society of Medical Physics (JSMP) in 2002. The protocol deals with proton and heavy ion beams as well as photon and electron beams, in accordance with IAEA Technical Report Series No. 398. To establish inter-institutional uniformity in proton beam dosimetry, an intercomparison program was carried out with the new protocol. The absorbed doses are measured with different cylindrical ionization chambers in a water phantom at a position of 30-mm residual range for a proton beam, that had range of 155 mm and a spread out Bragg peak (SOBP) of 60-mm width. As a result, the intercomparison showed that the use of the new protocol would improve the +/- 1.0 % (one standard deviation) and 2.7 % (maximum discrepancy) differences in absorbed doses stated by the participating institutions to +/- 0.3% and 0.9 %, respectively. The new protocol will be adopted by all of the participants.

  • PDF

Properties of Water Substitute Solid Phantoms for Electron Dosimetry

  • Saitoh, Hidetoshi;Tomaru, Teizo;Fujisaki, Tatsuya;Abe, Shinji;Myojoyama, Atsushi;Fukuda, Kenichi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.255-259
    • /
    • 2002
  • To reduce the uncertainty in the calibration of radiation beams, absorbed dose to water for high energy electrons is recommended as the standards and reference absorbed dose by AAPM Report no.51 and IAEA Technical Reports no.398. In these recommendations, water is, defined as the reference medium, however, the water substitute solid phantoms are discouraged. Nevertheless, when accurate chamber positioning in water is not possible, or when no waterproof chamber is available, their use is permitted at beam qualities R$\_$50/ < 4 g/cm$^2$ (E$\_$0/ < 10 MeV). For the electron dosimetry using solid phantom, a depth-scaling factor is used for the conversion of depth in solid phantoms to depth in water, and a fluence-scaling factor is used for the conversion of ionization chamber reading in plastic phantom to reading in water. In this work, the properties, especially depth-scaling factors c$\_$p1/ and fluence-scaling factors h$\_$pl/ of several commercially available water substitute solid phantoms were determined, and the electron dosimetry using these scaling method was evaluated. As a result, it is obviously that dose-distribution in solid phantom can be converted to appropriate dose-distribution in water by means of IAEA depth-scaling.

  • PDF