• 제목/요약/키워드: Technical feasibility

검색결과 499건 처리시간 0.026초

Health Monitoring System (HMS) for structural assessment

  • e Matos, Jose Campos;Garcia, Oscar;Henriques, Antonio Abel;Casas, Joan Ramon;Vehi, Josep
    • Smart Structures and Systems
    • /
    • 제5권3호
    • /
    • pp.223-240
    • /
    • 2009
  • As in any engineering application, the problem of structural assessment should face the different uncertainties present in real world. The main source of uncertainty in Health Monitoring System (HMS) applications are those related to the sensor accuracy, the theoretical models and the variability in structural parameters and applied loads. In present work, two methodologies have been developed to deal with these uncertainties in order to adopt reliable decisions related to the presence of damage. A simple example, a steel beam analysis, is considered in order to establish a liable comparison between them. Also, such methodologies are used with a developed structural assessment algorithm that consists in a direct and consistent comparison between sensor data and numerical model results, both affected by uncertainty. Such algorithm is applied to a simple concrete laboratory beam, tested till rupture, to show it feasibility and operational process. From these applications several conclusions are derived with a high value, regarding the final objective of the work, which is the implementation of this algorithm within a HMS, developed and applied into a prototype structure.

철도차량용 선형유도전동기 성능시험기의 공극조절 시스템 특성 연구 (Characteristic Analysis of Air-gap Control System in Performance Test Machine of a LIM for Railway Transit)

  • 박찬배;이형우;이병송;박현준;권삼영;한경희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1955-1961
    • /
    • 2008
  • A lot of researches on a linear induction motor(LIM) have been advanced to realize a traction system with high efficiency and performance for railway transit for a long time. However, most of them are limited in design of a LIM part such as Primary and Secondary. At a LIM which is traveling, the change of an air-gap(It occurs by a construction tolerance of a secondary reaction plate) becomes the cause which decreases a smoother ride and the efficiency of railway transit system. Therefore, uniform air-gap operation of LIM is important issue to improve the system efficiency. However, the researches which control the air-gap length of the LIM with technical and high-cost problem have been not advanced a lot. Therefore, in this research, it is introduced an air-gap control system for performance test machine of a scale-downed LIM which is able to control the air-gap length of the LIM and monitor a variety of performance changes of the propulsion system, and conducted a research on feasibility of the system based on characteristic analysis.

  • PDF

LCD 제조공정에서의 폐용매 분리처리를 위한 공정 설계 (Design of Waste Solvent Treatment Process from LCD Manufacturing Process)

  • 윤문규;이문용
    • 청정기술
    • /
    • 제14권4호
    • /
    • pp.275-280
    • /
    • 2008
  • 연구에서는 LCD 제조 공정에서 배출되는 스트리퍼와 디벨로퍼 혼합 폐액(SD폐액)과 스트리퍼 폐수의 효과적 분리 및 처리를 위한 가능한 기술로서 추출공정과 증류공정의 기술적/경제적 타당성을 검토하였다. SD폐액과 스트리퍼 폐수의 추출분리를 위한 용매로 $CHCl_3$가 여러 가지 관점에서 가장 적절한 용매로 확인되었다. 또한 SD폐액 분리 회수를 위한 공정으로서 추출공정과 증류공정의 두 가지 공정에 대하여 정밀 전산모사를 수행한 결과 $CHCl_3$를 이용한 추출분리공정이 단순증류공정보다 6배 정도 에너지 소요비용이 적게 소요됨을 확인할 수 있었다.

  • PDF

교방천 복원을 위한 분산형 유지유량 확보 방안 연구 (I): 수량.수질 타당성 검토를 위한 도시 물순환 모형 적용 (Study on decentralized options of the in-stream flow for restoring the Gyobang cheon: application of the Urban Volume and Quality (UVQ) model to examine feasibilities in water quantity and quality)

  • 신상민;최고은;이상은;박희경
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.699-706
    • /
    • 2011
  • This study has a purpose of examining technical feasibility of supplying the in-stream flow for the Gyobang cheon by using treated water from small wastewater treatment facilities as a decentralized option. To do this, the water and contaminant flow in study areas of the Gyobang cheon are defined from the context of the integrated urban water cycle, and analyzed by using the Urban Volume and Quality (UVQ) model. First, the UVQ model was built for the study areas of the Gyobang cheon and calibrated with observation data. Second, the decentralized options of the in-stream flow was explored with consideration of availability of water sources. The UVQ simulation then led to selecting the best option which would meet the criteria of water quantity and quality. It was finally concluded that using water sources out of study areas 1 and 2, adjoining the upper part of the Gyobang cheon, in the decentralized manner can be a feasible option for in-stream flow. It also seems that the UVQ model is useful to understand the water cycle in study areas of the Gyobang cheon.

Performance Verification Process for Introduction of Open Source Software -centered on introduction of Linux into the NEIS-

  • Kim Doo-Yeon;Kim Jong-Bae;Rhew Sung-Yul
    • 한국산업정보학회논문지
    • /
    • 제11권3호
    • /
    • pp.59-68
    • /
    • 2006
  • Recently, introduction of Open Source Software into informatization of the government and public sector has been actively examined, however, Open Source Software is being rarely adopted due to the lack of verified and reliable data with regard to the criteria, process, performance and stability for introduction of Open Source Software. In this paper, the process, method and plan for performance verification for introduction of Open Source Software into mission critical systems of the government and public sector are suggested in order to solve the aforesaid problem Specially, a test system to judge whether or not to adopt Open Source Software in school affairs system of the NEIS(National Education Information System) of the Korean government was set up, and the method and process of performance verification by stage in addition to feasibility study were applied to the test system for verification. Based on the result of performance evaluation in the test system, the application of Linux to school affairs system of the NEIS is being successfully practiced. It is expected that this study will be a guideline to technical review process and performance verification method as necessary to introduce Open Source Software into the mission critical systems of government and public agencies.

  • PDF

지열히트펌프 시스템의 국내 적용현황 조사 및 분석 (Investigation and Analysis on the present state of Geothermal Source Heat Pump System Applied in Korea)

  • 최미영;고명진;김용식;박진철;이언구
    • 설비공학논문집
    • /
    • 제21권5호
    • /
    • pp.267-272
    • /
    • 2009
  • This study aims to investigate and analyze the present state of ground source heat pump(GSHP) system applied in Korea. It is based on the statistic from the New and Renewable Energy Center in Korea and construction results of the professional companies registered to the center. The research items were installed area, installed year, building use, ground heat exchange type and heat exchanger type of the pump. According to the result of investigation, the using GSHP system have been increasing steadily as the space heating and cooling system in a building. The capacity of this system is also becoming lager based on technical and economical feasibility analysis about the system since GSHP system first introduced in 2000.

건축자재의 산화티타늄 코팅을 통한 휘발성 유기화합물 분해 (Destruction of Volatile Organic Compounds Using Photocatalyst-Coated Construction Materials)

  • 조완근;전희동
    • 한국환경과학회지
    • /
    • 제14권8호
    • /
    • pp.785-792
    • /
    • 2005
  • In order to reduce roadside and indoor air pollution for volatile organic compounds VOC), it may be necessary to apply photocatalyst-coated construction materials. This study evaluated the technical feasibility of the application of $TiO_2$ photocatalysis for the removal of VOC present in roadside or indoor air. The photocatalytic removal of five target VOC was investigated: benzene, toluene, ethyl benzene and o,m,p-xylenes. Variables tested for the current study included ultraviolet(UV) light intensity coating materials, relative humidity (RH), and input concentrations. Prior to performing the parameter tests, adsorption of VOC onto the current experiment was surveyed, and no adsorption was observed. Stronger UV intensity provided higher photocatalytic destruction(PCD) efficiency of the target compounds. For higher humidity, higher PCD efficiency was observed. The PCD efficiency depended on coating material. Contrary to certain previous findings, lower PCD efficiencies were observed for the experimental condition of higher input concentrations. The current findings suggested that the four parameters tested in the present study should be considered for the application of photocatalyst-coated construction materials in cleaning VOC of roadside or indoor air.

2단 DC-DC 컨버터로 구성된 배터리 에너지저장용 계통연계형 전력변환장치 (Grid-tied Power Conditioning System for Battery Energy Storage Composed of 2-stage DC-DC converter)

  • 박아련;김도현;김경태;한병문;이준영
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1848-1856
    • /
    • 2012
  • This paper proposes a new grid-tied power conditioning system for battery energy storage, which is composed of a 2-stage DC-DC converter and a PWM inverter. The 2-stage DC-DC converter is composed of an LLC resonant converter connected in cascade with a 2-quadrant hybrid-switching chopper. The LLC resonant converter operates in constant duty ratio, while the 2-quadrant hybrid-switching chopper operates in variable duty ratio for voltage regulation. The operation of proposed system was verified through theoretical analysis and computer simulations. Based on computer simulations, a hardware prototype was built and tested to confirm the technical feasibility of proposed system. The proposed system could have relatively higher efficiency and smaller size than the existing system.

Investigating deformations of RC beams: experimental and analytical study

  • Parrotta, Javier Ezeberry;Peiretti, Hugo Corres;Gribniak, Viktor;Caldentey, Alejandro Perez
    • Computers and Concrete
    • /
    • 제13권6호
    • /
    • pp.799-827
    • /
    • 2014
  • In this paper, a theoretical and experimental study of the sectional behaviour of reinforced concrete beams subjected to short-term loads is carried out. The pure bending behaviour is analysed with moment-curvature diagrams. Thus, the experimental results obtained from 24 beams tested by the authors and reported in literature are compared with theoretical results obtained from a layered model, which combines the material parameters defined in Model Code 2010 with some of the most recognized tensions-tiffening models. Although the tests were carried out for short-term loads, the analysis demonstrates that rheological effects can be important and must be accounted to understand the experimental results. Another important conclusion for the beams tested in this work is that the method proposed by EC-2 tends to underestimate the tension-stiffening effects, leading to inaccuracies in the estimations of deflections. Thus, the actual formulation is analysed and a simple modification is proposed. The idea is the separation of the deflection prediction in two parts: one for short-term loads and other for rheological effects (shrinkage). The results obtained are in fairly good agreement with the experimental results, showing the feasibility of the proposed modification.

Copper or ferrous slag as substitutes for fine aggregates in concrete

  • Thomas, Job;Thaickavil, Nassif N.;Abraham, Mathews P.
    • Advances in concrete construction
    • /
    • 제6권5호
    • /
    • pp.545-560
    • /
    • 2018
  • The ever-increasing cost of natural sand and the environmental impacts of extracting manufactured sand (quarry sand) calls for exploring the potential to use alternative materials as fine aggregates in concrete. Copper slag and ferrous slag are industrial by products obtained from the smelting process of copper and iron respectively. A large quantity of copper slag and ferrous slag end up being disposed as waste in landfills and this poses a serious threat to the environment. Copper slag and ferrous slag have similar physical and chemical properties as natural sand and also exhibit pozzolanic activity. This paper studies the technical feasibility of industrial by-products such as copper slag and ferrous slag to replace the fine aggregate in concrete by evaluating the workability, strength and durability characteristics of concrete. The test results indicate that the strength properties are not affected by 40% or 100% replacement of quarry sand with iron slag or copper slag. However, 40% replacement of quarry sand with iron slag or copper slag in concrete is recommended considering the durability aspects of concrete.