• Title/Summary/Keyword: Tear film break-up time

Search Result 24, Processing Time 0.03 seconds

Comparison of tear film break-up time and high order aberration according to soft contact lens material (소프트콘택트렌즈 재질에 따른 눈물막 파괴시간과 고위수차의 비교)

  • Kim, Bong-Hwan;Han, Sun-Hee;Kim, Hak-Jun;Bae, Sang-A;Son, Yu-Jin;Kim, Ji-Hyun;KIm, Hyun-Ji
    • Journal of Korean Clinical Health Science
    • /
    • v.7 no.1
    • /
    • pp.1232-1237
    • /
    • 2019
  • Purpose. In this study, two types of soft contact lenses with different materials were selected to compare the time of tear film destruction and high order aberrations before and after wearing. Methods. Thirty patients (60 eyes) in their 20s were included in this study. Two lenses with different materials, Group 4 (Etafilcon A) and Group 5 (Narafilcon A) were selected. Using aberration analyzer and keratometry, high-order aberration and tear film test (NIF-BUT, NIAvg-BUT) were performed before and after wearing. Results. When comparing the higher aberrations of the Etafilcon A and Narafilcon A lenses, the higher aberrations of the Narafilcon A lens were higher overall. For the initial tear film break-up time (NIF-BUT) after wearing, the Etafilcon A lens was reduced by 4.0 seconds and the Narafilcon A lens increased by 0.6 seconds. For the mean tear film break-up time (NIAvg-BUT) after wearing, the Etafilcon A lens decreased by 2.4 seconds and the Narafilcon A lens increased by 1.7 seconds. Conclusions. NIF-BUT and NIAvg-BUT of Narafilcon A lens were increased. The lens with relatively low water content and higher oxygen permeability than the lens with high water content has relatively less tear evaporation, which means that the time of destruction of the tear film is increased.

The Difference in Tear Film Stability between Normal and Dry Eyes by Wearing Clear and Circle Contact Lenses made of the Same Materials (동일 재질의 투명 및 써클콘택트렌즈 착용 시 정상안과 건성안의 눈물막 안정성 차이)

  • Lee, Sehee;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.11-21
    • /
    • 2016
  • Purpose: The aim of this study was to analyze the difference in tear film stability according to the wearing time when wearing clear and circle soft contact lens(circle lens) made of same material. Methods: The clear and circle contact lenses of hilafilcon B and nelfilcon A materials were respectively applied on the subjects classified as normal and dry eyes depending on their tear volume, and their tear film stability was investigated by measuring the non-invasive tear film break-up times, lens centration and the first appearing area of tear breakup after 30 mins and 6 hrs of lens wearing. Results: Non-invasive tear film breakup time significantly reduced with increase of the wearing time for normal and dry eyes when wearing clear and circle contact lenses. The starting ratio of tear film break-up was higher at the peripheral area of clear and circle lenses in all two different materials, and higher at the peripheral area of dry eyes than normal eyes. Starting ratio of tear film break-up was higher at the peripheral area of nelfilcon A lenses compared with hilafilcon B lenses, however, its change with the increase of wearing time showed a different aspect. The number of tear film break-up per unit area when wearing circle lenses of nelfilcon A increased at the central area with the wearing time while its number was higher at the peripheral area when wearing circle lenses of hilafilcon B. The centration of clear lenses made of two materials was closer to pupil compared to circle lenses with the increase of wearing time, however, a larger decentration was shown in dry eyes compared with normal eyes. Conclusions: The research revealed that an effect on tear film stability may be changed by clear lenses as well as circle lenses with coloring process according to the increase of wearing time, and the factors affecting on tear film stability may also vary depending on lens materials. Thus, the appropriate lenses should be selected by the consideration of lens material as well as coloring method/dyes according to the wearers' habit such as daily wearing time and wearing period when trying to wear clear and circle lenses.

The Effect of Circle Contact Lens on the Stability of Tear Film (써클콘택트렌즈가 눈물막 안정성에 미치는 영향)

  • Lee, Sehee;Hyung, Sung Min;Koh, Seung Hwan;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.125-131
    • /
    • 2015
  • Purpose: The effect of pigmentation in circle contact lens on lens wearers' tear film stability was investigated in this study. Methods: Non-invasive tear film break-up times of 54 normal eyes before and after lens wearing in twenties and the portion of first tear breakup were measured. The frontal and back surface roughness of circle contact lens was further observed with a scanning electron microscope. The clear lens which was made of hilafilcon B and circle contact lenses which were made of hilafilcon B, polymacon and copolymer of HEMA NVP were tested. Results: Non-invasive tear film breakup time was significantly reduced compared with it before lens wearing. In some case, statistically significant difference in tear film breakup time was also observed between circle contact lenses. The tear file break-up was usually early started in lower than upper portion, and in temporal than nasal portion although there was variation in the lens material. The tear film break-up of circle contact lenses made of hilafilcon B was more commonly observed in peripheral portion(pigmented area) compared with clear contact lens made of same material. Conclusions: The present study revealed that the stability of tear film was affected by wearing circle contact lens and the result seems to be used as the basis for the problem solving that can occur due to the pigmentation when wearing circle contact lens.

The Difference of Tear Break-Up Time by the Fitting States of Soft Contact Lens in Normal and Dry Eyes (정상안과 건성안에서 소프트렌즈 피팅 상태에 따른 비침입성 눈물막 파괴 시간의 차이)

  • Jung, Da I;Lee, Heum Sook;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.339-346
    • /
    • 2010
  • Purpose: The study was performed to compare the difference of non-invasive tear break-up time (NIBUT) with alignment or steep fitting of soft contact lens in normal and dry eyes. Methods: Total 40 eyes (aged 20~30 years) were classified to the normal (n=20) or dry eye group (n=20) by the diagnosis methods for dry eyes and worn soft contact lens (polymacon material) with alignment or steep fitting. NIBUTs of lens wearers were separately measured at the points of before wearing, immediately after wearing and after stabilization of tear film. Results: With alignment fitting, averaged NIBUT in the dry eye group after stabilization of tear film was not significantly different from that of the normal eye group. However, averaged NIBUTs in the normal and dry eyes had significant difference when measured immediately after lens wearing. However, the number of eyes having NIBUT less than 4.0 second was 30% higher compared to the number of normal eyes with steep fitting when measured immediately after wearing. Some shorten NIBUT in dry eyes with steep fitting was also shown after stabilization of tear film. Conclusions: These results suggest that wearing soft contact lens in dry eyes differently affect tear film compared to normal eyes. Thus, dry eyes need more advertent fitting for contact lens wearing because of unstable tear film.

A Study on the Confidence of Dry Eye Diagnosis Methods (건성안 검사 방법의 신뢰도에 대한 연구)

  • Lee, Byeong Jun;Hong, Jae Hyeon;Jung, Dai;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.15-20
    • /
    • 2008
  • Purpose: To study on the confidence of dry eye diagnosis methods which need to prescribe contact lens. Methods: Non-invasive tear film break-up time (NIBUT) and tear film break-up time (TBUT) were measured in forty healthy subjects in their 20s, and then the subjects were classified into normal eye and dry eye. The results of McMonnies questionnaire, tear prism height measurement, Hardtack test, blink rate measurement and Schirmer test were compared with the results of NIBUT and TBUT. Results: The results of NIBUT and TBUT were as follows; 20 subjects had normal eyes, 10 subjects had dry eyes in both NIBUT and TBUT, and 10 subjects showed different results. In McMonnies questionnaire, the score of normal eye group averaged 8.2 and that of dry eye group averaged 18.5, which showed statistically significant difference. Furthermore, 100% of normal eye group classified by the results of NIBUT and TBUT corresponded with the result of McMonnies questionnaire and 90% of dry eye group showed the correspondence. Tear prism height of normal eye group averaged 0.32 mm and that of dry eye group averaged 0.23 mm, which were significantly different. Hardtack test, blink rate measurement and Schirmer test without local anesthesia showed no statistically significant difference between normal eye group and dry eye group. Conclusions: On dry eye diagnosis methods, the results of McMonnies questionnaire and tear prism height measurement had close correlation with the results of NIBUT and TBUT.

  • PDF

Changes in Subjective Symptom, Tear Film Stabilization and Blinking Rates when Wearing RGP Lenses with Different Polishing Conditions for Certain Period of Time (연마상태가 다른 RGP렌즈의 일정기간 착용 시 렌즈착용자의 자각적 증상, 눈물막 안정 및 순목횟수 변화)

  • Park, Mijung;Kim, Hyo Gyum;Bae, Jun Seob;Park, Jung Ju;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.31-42
    • /
    • 2014
  • Purpose: The present study was conducted to investigate the effect of the physical properties of RGP lens induced by lens polishing on the actual wearer's subjective comfort, the tear film break-up time and the blinking rate as a follow-up study that revealed the relationship between the lens physical properties during lens manufacturing and lens wearer's factors. Methods: RGP lenses made from the three different polishing conditions (25, 50 and 100 seconds) were applied on 28 eyes of 17 subjects, aged 20 to 29 years, without any known disease and surgical history in the eyes. While the subjects were asked to wear the RGP lenses longer than a week, the questionnaire for the comfortability was administered everyday. Subjective and objective tear break-up time and blinking rate of the wearers were further measured. Results: The wearer's subjective comfortability showed some difference in the type of discomfort and satisfaction score according to the polishing status when wearing RGP lenses made from different polishing conditions longer than a week, and a bigger difference in satisfaction score induced by polishing condition was especially shown in experienced RGP lens wearer rather than un-experienced wearer. In the case of RGP lens wearer compared with the ones without the wearing experience, as the wearing time increased subjective and objective tear break-up time were increased and the blinking rate was decreased. However, subjective and objective tear break-up time were tended to decrease with even longer wearing time when wearing the RGP lens made from the polishment for 100 seconds. Conclusions: These results confirmed that the optimization of physical properties of the lens may not give the same effect on the wearer's subjective and objective symptoms and other factors when actual wearing. From the results, it can suggest that the success rate of RGP lens wear may be changed by physiological factors such as the stabilization of wearer's tear film, comfortability and lens wearing experience when wearing RGP lens based on 'The manufacturing standard for soft contact lens/hard contact lens' provided by Korea Food and Drug Administration.

The Effects of Auricular Acupressure Therapy on Middle-aged and Old Adults' Dry Eye Syndrome (이압요법이 중·노년의 안구건조증에 미치는 효과)

  • Choi, Yun-Joo;Hwang, Sun-Kyung;Kim, Sang-Sik
    • Journal of East-West Nursing Research
    • /
    • v.26 no.1
    • /
    • pp.17-27
    • /
    • 2020
  • Purpose: This study aimed to examine the effect of auricular acupressure therapy on reducing the ocular symptoms and signs for dry eye syndrome. Methods: The participants who were aged ≥ 40 years old and met the inclusion criteria of the ocular surface disease index score ≥ 13 and a tear film break-up time ≤ 10 seconds were enrolled into the two groups: experimental group (n=29) and control group (n=27). Experimental group received auricular acupressure therapy for 8 weeks. Seed stickers were applied to the eye, liver and tubercle point of each ear once a week. Data were collected at pre and 4 and 8 weeks after the treatment and analysed the efficacy of intervention by repeated measures ANOVA. Results: There were significant differences in the ocular surface disease index, standard patient evaluation of eye dryness and a tear film break-up time in both eyes at 8 weeks after the treatment between the two groups. Conclusion: The findings indicate that the auricular acupressure therapy may be helpful for relieving symptoms of dry eye as a nursing intervention. In addition, it could also be utilized as a self-care practice using proper education and training.

Change in Axial Rotation of Toric Soft Contact Lens according to Tear Volume (눈물양에 따른 토릭 소프트콘택트렌즈의 축 회전양 변화)

  • Seo, Woo Hyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.445-454
    • /
    • 2015
  • Purpose: The present study was aimed to investigate the effect of tear volume on a change of axial rotation according to wearing time of toric soft contact lens and gaze directions. Method: Toric soft contact lenses with double thin zone design applied on 62 eyes. Then, changes in non invasive tear film break-up time and the rotational direction/amount of lens when changing gaze direction were respectively measured after 15 minutes and 6 hours of lens wear. Results: Lens rotation to temporal direction was more found when changing gaze direction after lens wear. However, its rotation was varied according to wearing time and the subjects' tear volume. Furthermore, the frequency of lens rotation to temporal direction was higher in dry eyes compared with normal eyes at nearly all gaze directions after 15 minutes and 6 hour of lens wear. The rotational amount of lens was generally greater in dry eyes after 15 minutes of lens wear. However, its difference between normal eyes and dry eyes was not great after 6 hours of lens wear. Conclusion: The present study revealed that axial rotation of toric soft contact lens was varied according to the wearer's tear volume and lens rotational patterns at the initial, and extending periods of lens wear were different. The change in rotational pattern of toric soft contact lens from these results means the possibility of visual change after extending lens wear, and the identification of its correlation with tear volume suggests the necessity of considering factors for choosing appropriate toric soft contact lens.

Comparison Among the Four Examination Methods for Dry Eye (OQAS test, TBUT, Schirmer Test, McMonnies test) (4가지 건성안 분석방법(OQAS test, TBUT, Schirmer test, McMonnies test)의 비교)

  • Park, Chang Won;Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.519-526
    • /
    • 2015
  • Purpose: To evaluate the changes of OSI value according to tear-film instability measured serially by OQAS(Optical Quality Analysis System, Visiometrics, Spain) every seconds. The presented study analyzed the relationship of the OQAS parameter with the results of the tear-film break-up time, Schirmer test, and the McMonies score. Methods: 147 eyes of 82 subjects were randomly selected from university students (age: $21.51{\pm}3.97$, male 45, female 37). Subjects were measured tear-film break-up time, Schirmer test, McMonies score and once every second for 15 seconds after blinking by continuous measurements from OQAS system. Results: The normal eye groups presented OSI values of $2.13{\pm}1.16$ while the dry eye groups had OSI values of $3.76{\pm}1.42$. Therefore, a significant difference between the normal eye group and dry eye group was discovered (p<0.05). In addition, the OSI value of all subjects increased over time. The OSI value, which was measured every second after blinking occurred, significantly increased between 6 seconds and 7 seconds after the start of the measurement (p<0.05). OSI cut off of 30% (sec.) showed a greater correlation; TBUT (r = 0.855, p = 0.000), McMonies test (r = -0.351, p = 0.003), Schirmer (r = 0.316, p = 0.012). Conclusions: Continuous measurement of OQAS showed a high correlation with the value of the existing dry eye tests. Therefore, Analysis of OSI values by utilization of OQAS could be useful in objectively evaluation of tear film in patients.

Effects of Humidity Changes on Eyes (습도 변화가 눈에 미치는 영향)

  • Sun-Hee Han;Bong-Hwan Kim;So-Bin Kim;Min-Jung Kim;Hee-Kyung Park;Hyun-Ji Kim;Heon-Tae Kim;Hyeong-Su Kim
    • Journal of Korean Clinical Health Science
    • /
    • v.11 no.1
    • /
    • pp.1616-1624
    • /
    • 2023
  • Purpose. The purpose of this study was to investigate the effect of changes in tear break-up time, accommodative response amount, and accommodative microwave on the eyes due to changes in humidity. Methods. A total of 48 adult men and women in their 20s (21.1±1.56 years old) were surveyed on dry eye questionnaires (OSID questionnaires), tear destruction time was measured by humidity (40%, 60%, 80%), and controlled reactions and controlled fine waves were measured through tactile tests. Result. As a result of the OSID questionnaire, there were 10 normal patients, 8 mild dry eyes, 1 moderate dry eye, and 5 severe dry eyes. The initial tear film destruction time was 7.34±4.67 seconds at 40% humidity, 8.99±4.75 seconds at 60% humidity, 10.26±4.52 seconds at 80% humidity, and the average tear film destruction time was 9.51±4.07 seconds at 40% humidity, 10.99±3.82 seconds at 60% humidity, and 12.05±3.42 seconds at 80% humidity. The accommodative response was -0.41~1.79D at 40% humidity, -0.34~1.79D at 60% humidity, and -0.30~2.01D at 80% humidity. The accommodative microwave was measured as 56.39~63.43dB when it was 40%, 56.41~62.64dB when it was 60%, and 55.96 ~61.13dB when it was 80%. Conclusion. As the humidity (40~80%) increased, the tear break-up time increased, and as the accommodative stimulus amount increased, the accommodative response amount increased. It was found that the accommodative microwave according to the amount of accommodative stimulation increased, and as the humidity increased, the accommodative microwave decreased.