• 제목/요약/키워드: Team efficiency

검색결과 1,022건 처리시간 0.025초

직접분사식 가솔린 엔진의 연소제어인자에 따른 희박연소 특성 연구 (A Study on the Lean Combustion Characteristics with Variation of Combustion Parameter in a Gasoline Direct Injection Engine)

  • 박철웅;오진우;김홍석
    • 한국자동차공학회논문집
    • /
    • 제20권4호
    • /
    • pp.39-45
    • /
    • 2012
  • Today gasoline engines for vehicular application are not only faced with stringent emission regulation but also with increasing requirements to better fuel economy, while guaranteeing power density. The spray-guided type gasoline direct injection (GDI) engine has an advantage of improved thermal efficiency and lower harmful emissions. Centrally mounted high pressure injector and adjacent spark plug allow stable lean combustion due to the flexible mixture stratification. In the present study, the performance and emissions characteristics of developed spray-guided type GDI combustion system were evaluated at various excess air ratio conditions. The specific fuel consumption and nitrogen oxides ($NO_x$) emissions were reduced due to the achievement of stable lean combustion under flammability limit. Multiple injection strategy was not helpful to improve fuel consumption while further reduction of $NO_x$ emissions was possible.

어선원 인명피해 최소화를 위한 구명동의용 위성자동위치발신기의 특성 (Characteristics of automatic positioning transmitter (APT)using satellite on life jacket to minimize casualties of fisherman)

  • 김석재;김욱성;이유원
    • 수산해양기술연구
    • /
    • 제48권3호
    • /
    • pp.235-241
    • /
    • 2012
  • The efficiency tests of automatic positioning transmitter (APT) using satellite on life jacket were carried out to minimize casualties of fishermen and to make system optimization for effective SAR (Search and Rescue) operation. As the result of the tests, average position was equaled on the comparison between SPOT using low earth orbit satellite and DGPS (Differential Global Positining System), but standard deviation of DGPS for latitude and longitude were 66.4% and 46.3% smaller than those of SPOT. The position precision of SPOT was almost two times lower than LGT using geostationary satellite to compare 95% circular error probability. However, the success rate of receiver for SPOT was revealed as 86.5~94.1% on the experiments in the South Sea and the West Sea and it was 4.5 times higher than LGT. Therefore, SPOT is expected to contribute greatly to the rapid rescue of victim.

북미 Tier2 Bin5 규제 대응을 위한 디젤 SCR 개발 (Diesel SCR Development to Meet US Tier2 Bin5 Emission Regulation)

  • 이강원;강중훈;조청훈
    • 한국자동차공학회논문집
    • /
    • 제19권2호
    • /
    • pp.98-104
    • /
    • 2011
  • The introduction of a diesel engine into the passenger car and light duty applications in the United States involves significant technical challenges for the automotive makers. This paper describes the SCR System optimization procedure for such a diesel engine application to meet Tier2 Bin5 emission regulation. A urea SCR system, a representative $NO_x$ reduction after-treatment technique, is applied to a 3.0 liter diesel engine. To achieve the maximum $NO_x$ reduction performance, the exhaust system layout was optimized using series of the computational fluid dynamics and the urea distribution uniformity test. Furthermore a comprehensive simulation model for the key factors influencing $NO_x$ reduction performance was developed and embedded in the Simulink/Matlab environment. This model was then applied to the urea SCR system and played a key role to shorten the time needed for SCR control parameter calibration. The potential of a urea SCR system for reducing diesel $NO_x$ emission is shown for FTP75 and US06 emission standard test cycle.

Numbers Cup Optimization: A new method for optimization problems

  • Vezvari, Mojtaba Riyahi;Ghoddosian, Ali;Nikoobin, Amin
    • Structural Engineering and Mechanics
    • /
    • 제66권4호
    • /
    • pp.465-476
    • /
    • 2018
  • In this paper, a new meta-heuristic optimization method is presented. This new method is named "Numbers Cup Optimization" (NCO). The NCO algorithm is inspired by the sport competitions. In this method, the objective function and the design variables are defined as the team and the team members, respectively. Similar to all cups, teams are arranged in groups and the competitions are performed in each group, separately. The best team in each group is determined by the minimum or maximum value of the objective function. The best teams would be allowed to the next round of the cup, by accomplishing minor changes. These teams get grouped again. This process continues until two teams arrive the final and the champion of the Numbers Cup would be identified. In this algorithm, the next cups (same iterations) will be repeated by the improvement of players' performance. To illustrate the capabilities of the proposed method, some standard functions were selected to optimize. Also, size optimization of three benchmark trusses is performed to test the efficiency of the NCO approach. The results obtained from this study, well illustrate the ability of the NCO in solving the optimization problems.

전기화학적 처리에 의한 배추 절임염수 재이용 가능성 평가 (Evaluation of brine reuse on salting of chinese cabbage using electrochemical process)

  • 정희숙;이은실;한성국;한응수
    • 상하수도학회지
    • /
    • 제28권5호
    • /
    • pp.541-548
    • /
    • 2014
  • The pickling brine generated from the salting process of kimchi production is difficult to treat biologically due to very high content of salt. When pickling brine is treated and discharged, it cannot satisfy the criteria for effluent water quality in clean areas, while resources such as the salt to be recycled and the industrial water are wasted. However, sterilization by ozone, UV and photocatalyst is expensive installation costs and operating costs when considering the small kimchi manufacturers. Therefore there is a need to develop economical process. The study was conducted on the sterilization efficiency of the pickling brine using electrochemical processing. The electrochemical treatment of organic matters has advantages over conventional methods such as active carbon absorption process, chemical oxidation, and biological treatment because the response speed is faster and it does not require expensive, harmful oxidizing agents. This study were performed to examine the possibility of electrochemical treatment for the efficient processing of pickling brine and evaluated the performance of residual chlorine for the microbial sterilization.

정지비행 로터 블레이드에 부착된 탭의 공기역학적 효과 (AERODYNAMIC EFFECTS OF THE TAB ON A HOVERING ROTOR BLADE)

  • 강희정;김도형;김승호
    • 한국전산유체공학회지
    • /
    • 제18권3호
    • /
    • pp.60-66
    • /
    • 2013
  • Numerical simulation was performed for the rotor blade with fixed tab in hover using an unstructured mesh Navier-Stokes flow solver. The inflow and outflow boundary conditions using 1D momentum and 3D sink theory were applied to reduce computational time. Calculations were performed at several operating conditions of varying collective pitch angle and fixed tab length. The aerodynamic effect of fixed tab length was investigated for hovering efficiency, pitching moment and flapping moment of the rotor blade. The results show that it affects linearly increasing on the pitching moment of the rotor blade but does not affect on the flapping moment. The required power is less than 45kw for ground rotating test in hover. Numerical simulations also show that the vortex generate not only from the tip of the rotor blade but also from the fixed tab on the rotor blade.

세라믹 방열과 박막 적층 도금을 이용한 고효율 인버터 제어 회로용 퓨즈 설계 (The Design of Fuse in High Efficient Inverter Control System using Ceramic Radiant Heat and Metal Film Laminated Plating)

  • 김은민;김신효;조대권
    • 전기학회논문지
    • /
    • 제63권11호
    • /
    • pp.1538-1544
    • /
    • 2014
  • In recent years, The electronic and energy industries demand low power consumption and high efficiency, so under their demands, the white goods industries which are represented for refrigerator and air conditioner system be implemented energy-saving power suppling structure with inverter control system. As inverter control system is different from step control type, when switching system is optimizing temperature control during short period, the inrush plus current can be flown in the circuit. In despite of these characteristics, there is no fuse which can be applied to this type until now. For this reason, we suggest the method of manufacturing protector in the high efficient inverter control system using the alumina-based ceramic radiated heat characteristics and metal films laminated plating. And through the evaluating electrical characteristics, we make a possible to utilize the method when designing overall fuses.

Fiber내 유도체화/HS-SPME를 이용한 수용액 시료 중 휘발성 지방산의 분석 (Determination of Volatile Fatty Acids in Aqueous Samples by HS-SPME with In-Fiber Derivatization)

  • 안윤경;이지연;김지형;홍종기
    • 분석과학
    • /
    • 제16권6호
    • /
    • pp.458-465
    • /
    • 2003
  • 수용액 시료 중 휘발성 지방산을 HS (headspace)-SPME (Solid phase microextraction)를 이용하여 간편하고 빠르게 분석하는 방법에 대하여 연구하였다. 1-Pyrenyldiazomethane (PDAM)을 이용한 화이버 내 유도체화를 통하여 휘발성 지방산의 검출감도를 향상시킬 수 있었으며, SPME 추출조건으로 pH, 염 효과 및 초음파 추출에 대하여 조사하였다. 본 연구에서 개발된 방법을 기반으로 실제 폐수 중 휘발성 지방산을 추출하여 기체크로마토그래피/질량분석기-선택이온검색법으로 정량 분석하였다.

FPSO 선의 PAU SEAT 강도 해석 (Strength Analysis for PAU Seat of FPSO)

  • 하태민;김성수;송명근
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2005년도 특별논문집
    • /
    • pp.90-96
    • /
    • 2005
  • This paper presents the results of the reliability analysis of PAU (Preliminary Assembly Unit) seat of the floating Production Storage and Off1-loading Unit (FPSO) The main aim of the analysis was to demonstrate that a sufficient safety of structural members is guaranteed against PAU loads, internal and external pressure, and hull girder moments. Topside loads for PAU design are based on owner's request. According to the seat type, topside loads are classified into maximum values of same seat type for design efficiency. Totally, 26 loading cases for each model are used for this analysis with the combination of the reactions of PAU loafing and the hull girder bending moments according to LR offshore (2). The analysis results are evaluated according to the acceptance criteria for yielding given in LR offshore and guidance note (3) and The panel buckling resistance is verified by LR offshore and SDA (4). For 900,000 bbls FPSO, the PAU support foundation analysis using 3-D F.E. model is carried out to verify the structural adequacy of PAU foundation and structure members in way of PAU. The modified structures in way of PAU support are safe against considered load cases and all stresses in way of PAU support are within design criteria.

  • PDF

수냉식변압기 냉각튜브의 부식특성 평가에 관한 연구 (A Study on Evalution of Corrosion Properties in cooling tube of water cooling transformers)

  • 정년호;민병연;박현주
    • Corrosion Science and Technology
    • /
    • 제9권5호
    • /
    • pp.216-222
    • /
    • 2010
  • Most of the thirteen substations in operation in the metropolitan area were installed around the year 2000, and since water cooling methods are used to directly withdraw heat from transformer oils, a stable supply of electric power is required through optimal maintenance of facilities. The water cooling tower installed outdoors, which uses the water supply as sprinkler water, experiences the most problems. Since more than 90% of the cooling water is reused, the dissolved composition in the water becomes concentrated due to long operating hours, and impurities dissolve in the water due to air flowing in from the outside, forming hard scales on the outer surface of the cooling tube, and in extreme cases, reacting with the tube material composition, leading to corrosion. As a result, not only is cooling efficiency lowered, but in extreme cases the cooling tube must be replaced. In this study, the characteristics and composition of the scales formed on the cooling tube were analyzed and corrosion characteristics of material types were identified in order to find an efficient maintenance method for cooling tubes. In addition, the degree of dissolution of various chemicals were investigated during the removal of scales that have been formed.