• Title/Summary/Keyword: Tc-To method

Search Result 1,083, Processing Time 0.029 seconds

Rotordynamic Performance of High-Tc superconductor Bearings (고온초전도베어링의 회전체역학적 특성)

  • 성태현;이준성;한영희;김영철;최상규;김상준
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.180-184
    • /
    • 2000
  • The dymanic properties of the high-Tc superconductor journal bearings used in the KEPRI flywheel energy storage system was experimentally estimated by using the imbalance excitation method. The test reveals that the superconductor bearings have very low stiffness compared to that of typical oil film bearings with similar geometry and almost the same amount of damping as in roller bearings, which may not be helpful for the system to pass through the critical speeds. However, it was found out that the cross-coupled stiffness and damping terms were almost negligible so that the system could be more stable than the one using lil film bearings. Also with proper design of the rotor-bearing system and accurate balancing of the rotor, the high-Tc superconductor bearing is one of the most viable alternatives to the conventional ones due to its oil-free, non-contact running capability in a vacuum environment, which is literally essential for highly efficient flywheel energy storage systems.

  • PDF

Captopril Enhanced $^{99m}Tc-DMSA$ Renal Scintigraphy in A Case of Renovascular Hypertension Due to Branch Renal Artery Stenosis (신동맥분지협착에 의한 신혈관성고혈압 예에서 캅토프릴투여후 $^{99m}Tc-DMSA$ 신 스캔)

  • Yang, W.S.;Kim, Y.S.;Earm, J.H.;Kim, S.E.;Lee, D.S.;Han, J.S.;Chung, J.K.;Kim, S.;Lee, M.C.;Lee, J.S.;Koh, C.S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.2
    • /
    • pp.325-331
    • /
    • 1990
  • Radionuclide renal scintigraphies were performed in a 24-year-old man with right renal artery branch stenosis. Captopril enhanced $^{99m}Tc-DTPA$ renal scintigraphy revealed no abnormal finding in the right kidney. But, $^{99m}Tc-DMSA$ renal scintigraphy showed regional cortical photon deficient area corresponding to the area supplied by the stenotic branch artery. The defect size increased in captopril enhanced $^{99m}Tc-DMSA$ renal scintigrphy and nearly disappeared after successful transluminal renal angioplasty. This case suggests that the captopril enhanced $^{99m}Tc-DMSA$ renal scintigraphy may be a useful method in the evaluation of renovascular hypertension, especially due to branch renal srtery stenosis.

  • PDF

STUDY ABOUT A CONNECTIVE METHOD OF HIGH Tc SUPERCONDUCTING WIRE FOR LONG WIRE (고온 초전도 선재의 장선화를 위한 접속에 관한 연구)

  • 임성훈;강형곤;이재윤;임성우;한병성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.222-224
    • /
    • 1997
  • This study is about a connective method of High Tc wire for long wire. We prepared silver-sheathed BiPbSrCaCuO wires by the powder-in-tube method. Since the superconducting wires are ceramic, it is very hard to connect each other. In this study, we used a silver sleeve to contract wires and pressed them by various preasures. Then optimum preasure was 9,000 Kgf/$\textrm{cm}^2$ to get the high critical current. The higest critical current was 10A.

  • PDF

Estimation of Users대 Benefit Value for Woobang Tower Land in Taegu Using Travel Cost Method (여행비용접근법을 통한 대구 우방타워랜드의 편익가치 측정)

  • 김수봉;심애경;권기찬
    • Journal of Environmental Science International
    • /
    • v.10 no.3
    • /
    • pp.173-178
    • /
    • 2001
  • The aim of this paper is to evaluate users benefit values of theme park using Travel Cost Method with special reference to Woobang Tower Land in Taegu for the estimation of economic values. This research is mainly based on questionnaire survey of 100 users of the theme park. Socio-economic factors such as income, year of education, annual income, age and money(travel cost) are analysed from 5 residential areas of the respondents. Multiple regression analysis was used for the evaluation of annual number of park visitings based on the analysis. The regression model shows NV = $\alpha$+$\beta_1$TC+$\beta_2$INC+$\beta_3$EDU+$\beta_4$AGE (NV : Annual Number of Visitings, TC : Travel Cost, INC : Annual Income, EDU : Years of Education, AGE : Age). Regarding to visitors demand curve based on the equation showed that annual economic values of Woobang Tower Land was estimated as 50billion Korean Won.

  • PDF

Comparison of 99mTc-Tin colloid colloid and 99mTc-DISIDA Hepatoscintigraphy in Miniature Pigs (미니돼지에서 99mTc-Tin colloid와 99mTc-DISIDA를 사용한 간신티그라피의 비교 연구)

  • Shim, Kyung-Mi;Kim, Se-Eun;Lee, Won-Guk;Koong, Sung-Soo;Bae, Chun-Sik;Lee, Jae-Yeong;Choi, Seok-Hwa;Han, Ho-Jae;Kang, Seong-Soo;Park, Soo-Hyun
    • Journal of Life Science
    • /
    • v.16 no.6
    • /
    • pp.1060-1065
    • /
    • 2006
  • Non-invasive evaluation of liver function in animal models remains a challenge. Hepatoscintigraphy provides information about changes in liver size and shape, and enables to understand general liver function. Futhermore it is readily used to diagnosis complications of liver transplantation like hepatitis, rejections and biliary complications. In this study, we investigated the usefulness of evaluating the liver function in miniature pigs with $^{99m}Tc-Tin$ colloid and $^{99m}Tc-DISIDA$ which are the most commonly used radiopharmaceuticals in human medicine. In result, $^{99m}Tc-Tin$ colloid was uptaked in lung, liver, gastric wall and kidney in miniature pigs. And $^{99m}Tc-DISIDA$ showed continuous uptake images of heart, lung, liver, gallbladder and duodenum, and it was similar to human's. Therefore we could conclude $^{99m}Tc-Tin$ colloid would not be suitable for evaluating hepatic function because of it's nonspecific affinity, however $^{99m}Tc-DISIDA$ scintigraphy would be an effective method for detecting hepatobiliary function in miniature pigs.

A Design of TC layer Controller for ATM-PON OLT (ATM-PON OLT TC 계층 처리기 설계)

  • 이석훈;채종억;유태환;김봉태;김재근;김대영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.6B
    • /
    • pp.1059-1067
    • /
    • 1999
  • In this paper characteristics of ATM-PON is described and a TC layer controller for ATM-PON OLT is designed. This paper proposes an algorithm of economically controlling the grant information written by CPU to dynamically allocate the upstream bandwidth on the PON among the ONUs in a fair way and of encrypting the downstream data using a lower standard of encryption, termed data churning, which is used to distinguish it from existing transmission system scramblers and higher layer encryption methods. This paper also proposes a method of allocating churning-related message into the PLOAM cell in order to synchronously change the churning key between the OLT and the ONU.

  • PDF

Fabrication and Characterization of High $T_c$ $YBa_2Cu_3O_7-x$ Thick Films (YBCO 고온 초전도체 후막의 제작 및 특성 연구)

  • 정형진;박홍순;이전국;송진태
    • Journal of the Korean Ceramic Society
    • /
    • v.27 no.3
    • /
    • pp.299-310
    • /
    • 1990
  • The fabrication of Y-Ba-Cu-O films and experimental factors affecting to characteristics of films are studied in detail. Superconducting thick films are fabricated by the screen printing method. The metal-citrate precursors are obtained simply by mixing of metal nitrate with citric acid. The particle size of heat treated powders is approximately 0.3-1${\mu}{\textrm}{m}$ and the thickness of film is estimated as 30-35${\mu}{\textrm}{m}$. According to the XRD analysis, the films sintered at 870-93$0^{\circ}C$ for 10min. -6hr with P(oxygen)=1atm has the unique orthorhombic crystal symmetry indicating the 123 phae. Tc, onset is determined around 92-87。K, but it shows semiconducting behavior probably due to the oxygen deficiency in the lattice, porosity and impurities in films. Extrapolated Tc, zero is estimated as 76-50。K. For films sintered at 90$0^{\circ}C$ for 1hr, superconducting properties are observed with the room temperature resistivity of 0.025$\Omega$.cm Tc, onset at 88。K and Tc, zero at 63。K.

  • PDF

A Review on ISO Standards Applicable for a Human Error Tolerant Control Center Design (제어실의 인적오류 예방에 적용 가능한 ISO 표준 검토)

  • Lee, Dhong-Ha
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.161-168
    • /
    • 2011
  • Objective: The aim of this study is to review the ISO(the International Organization for Standardization) standards recommendations on a human error tolerant control room design. Background: ISO TC(Technical Committee) 159 published a variety of international standards on design of mental and physical work, design of displays and controls, and workstation layout design. A proper edition of these standards can be a good resource for a human error tolerant control center design guidelines. Method: Recommendations of ISO TC 159 standards were grouped into arrangement of control suite, layout of control room, layout and dimensions of workstations, design of displays and controls, environmental design, alarm, automation, management system design, procedure and training. Results: It was found that some standards on the design of supervisory control and data acquisition(SCADA), alarm, automation, layout, workload management, and environment can be used for human error prevention guidelines in the control center design. Conclusion: ISO TC 159 standards were not sufficient to cover all the ergonomics area of control center design. Application: Designers can have technical aids from these ISO standards to improve ergonomic performance of their control center.

Effect of Target Material and the Neutron Spectrum on Nuclear Transmutation of 99Tc and 129I in Nuclear Reactors (표적물질 및 중성자 스펙트럼이 99Tc과 129I의 원자로 내부 핵변환에 미치는 영향)

  • Kang, Seung-gu;Lee, Hyun-chul
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.2
    • /
    • pp.195-202
    • /
    • 2018
  • As a rule, geological disposal is considered a safe method for final disposal of high-level radioactive waste. However, some long-lived fission products like $^{99}Tc$ and $^{129}I$ contained in spent nuclear fuel are highly mobile as less sorbing anionic species in the subsurface environment and can mainly cause exposure dose to the ecosystem by emission of beta rays in the hundreds of keV range. Therefore, if these two nuclides can be separated and converted with high efficiency into radioactively unharmful nuclides, this would have a positive effect on disposal safety. One candidate method is to transmute these two nuclides in nuclear reactors into short-lived nuclides or into stable nuclides. For this purpose, it is necessary to evaluate which reactor type is more efficient in burning these two nuclides. In this study, the simulation results of nuclear transmutation of $^{99}Tc$ and $^{129}I$ in light water reactor (PWR), heavy water reactor (CANDU) and fast neutron reactor (SFR, MET-1000) are compared and discussed.

The Quantitative Assessment of Renal Function and Size by Differences of Acquisition Counts in $^{99m}Tc$-DMSA Renal Scan ($^{99m}Tc$-DMSA 신장검사에서 획득 계수의 차이에 따른 기능 및 형태 평가)

  • Shim, Dong-Oh;Kim, Ho-Sung;Chung, Eun-Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.117-121
    • /
    • 2010
  • Purpose: In nuclear medicine study, there are two methods, preset count method and preset time method, to acquire static images. We usually use preset count method for static image in $^{99m}Tc$-DMSA renal scan, but occasionally use preset time method. In case of using preset count method, we always acquire same counts but it causes a difference of scan time. In case of using preset time method, it takes same scan time to acquire images but it causes different counts. Therefore, the purpose of this study is to investigate any differences of function and formal information in both kidney by acquisition counts Materials and Methods: From January 11, 2010 to March 31, 2010, we analyzed the 30 patients (M: 11, W: 19). who were examined by $^{99m}Tc$-DMSA scan and have one side of functioning kidney relatively between 40~60%. And the patients who have cold and hot region in image were analyzed but we did not accept images of patients when it was hard to divide kidney into cortex. There was no division between subjects and age of subjects is $14.83{\pm}22.07$ old. We used the BrightView gamma camera from PHILIPS. To analyze function and formal of kidney, we used JET stream release 3.0 version from PHILIPS. Using SPSS 12.0 program, we compared descriptive statistics and paired T-test. Images were acquired sequentially in the same parameters, but there are three methods which different from acquisition time and scan time, 100 kcounts, 300 kcounts and 7 minutes method (exceed 300 kcounts). To assess function and formal information of kidney, we measured renal relative function, geometric mean and size of kidney and analyzed each difference. Results: In case of renal relative function in both kidney, 100 kcounts method was $50.52{\pm}3.64%$. 300 kcounts method was $50.38{\pm}3.66%$ and 7 minutes method was $49.91{\pm}3.40%$ and there were no statistical significant differences between each method. In case of geometric mean, 100 kcounts method was $50.08{\pm}3.25%$. 300 kcounts method was $49.89{\pm}3.40%$ and 7 minutes method was $49.91{\pm}3.24%$. And also, there were no statistical significant differences. When comparing size of kidney, 100 kcounts method was $8.23{\pm}1.96$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.35{\pm}1.97$ cm. In case of right kidney, 100 kcounts method was $7.91{\pm}1.88$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.25{\pm}1.96$ cm. From those values, we recognized that there were significant differences each method (p<0.05). Conclusion: From results of this study, there were no statistical differences in renal relative function and geometric mean by acquisition counts. However, in shape of kidney, the more acquisition counts are increasing, the more size of kidney is getting big. And there were statistical significant differences. Therefore, to perform reliable quantitative result, preset count method is more desirable than preset time method. Especially, in case of a follow-up test, if we use preset time method, it will cause differences of formal results in kidney due to acquisition counts each time we examine patients.

  • PDF