• Title/Summary/Keyword: Target mirror

Search Result 65, Processing Time 0.02 seconds

COMPARISON OF MIRROR FUNCTORS OF ELLIPTIC CURVES VIA LG/CY CORRESPONDENCE

  • Lee, Sangwook
    • Journal of the Korean Mathematical Society
    • /
    • v.57 no.5
    • /
    • pp.1135-1165
    • /
    • 2020
  • Polishchuk-Zaslow explained the homological mirror symmetry between Fukaya category of symplectic torus and the derived category of coherent sheaves of elliptic curves via Lagrangian torus fibration. Recently, Cho-Hong-Lau found another proof of homological mirror symmetry using localized mirror functor, whose target category is given by graded matrix factorizations. We find an explicit relation between these two approaches.

Research on Synthesis of Radiation Noise from Moving Target (이동하는 표적의 방사소음 합성기법 연구)

  • 배재휘
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.58-65
    • /
    • 2000
  • A target signal simulation method for passive sonar systems is introduced. The method uses multirate signal processing techniques to simulate moving target signals in the multi-path sound propagation environment by introducing Lloyd's mirror and Doppler effect. Time and frequency variation of target signal due to the target maneuvering is also considered to provide realistic ship signatures in the LOFAR gram so that the simulated target is used for sonar operator training. Synthesized target characteristics is analyzed and compared with real target signal in terms of interference pattern and frequency variation in the LOFAR gram.

  • PDF

Design of All-SiC Lightweight Secondary and Tertiary Mirrors for Use in Spaceborne Telescopes

  • Bae, Jong-In;Lee, Haeng-Bok;Kim, Jeong-Won;Kim, Myung-Whun
    • Current Optics and Photonics
    • /
    • v.6 no.1
    • /
    • pp.60-68
    • /
    • 2022
  • We report on the design of the secondary and the tertiary mirrors used in lightweight assemblies made entirely of silicon carbide (SiC). The essential design points are weight reduction within the acceptable deformation of the mirror surface by gravity release, temperature change, and vibration during or after space launch. To find a design that achieves the target requirements, we established finite element models for various candidate designs and subjected each one to wave front error analyses along gravity directions and in operation temperatures. We also calculated the natural frequencies of the candidate assemblies. Our study suggested that a triangular cell with bipod flexure support can satisfy the target weight within the requirements.

Improved kinematic mount design for bar type reference mirror for profilometric measurement large optical surface

  • Jung, Kil-Jae;Yang, Ho-Soon;Rhee, Hyug-Gyo;Jyun, Byoung-Hyug;Lee, Yun-Woo;Kim, Sug-Whan
    • Bulletin of the Korean Space Science Society
    • /
    • 2010.04a
    • /
    • pp.25.3-25.3
    • /
    • 2010
  • Our previous study used a bar-type reference mirror to measure the relative distance to the target surface. The target measurement accuracy was required to $1{\mu}m$ PV for aspheric optical surface up to 1m in diameter. Earlier system suffers from the reference surface deformation when the measuring part moves. In order to reduce the deformation, measuring part and the reference part separated from each order in the new design. This system utilizes a kinematic support assembly using invar flexure to minimize the reference surface deformation under gravity and vibration. The surface deformation requirement of reference mirror is defined as of $0.2{\mu}m$ under gravity and 40Hz vibration. The finite element results, shows reference mirror deformation of $0.164{\mu}m$. The first resonance mode was computed to analysis 46.05Hz for reference part and 43.44Hz for measuring part. Thesis satisfies the frequency requirement.

  • PDF

Development of a low energy ion irradiation system for erosion test of first mirror in fusion devices

  • Kihyun Lee;YoungHwa An;Bongki Jung;Boseong Kim;Yoo kwan Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.70-77
    • /
    • 2024
  • A low energy ion irradiation system based on the deuterium arc ion source with a high perveance of 1 µP for a single extraction aperture has been successfully developed for the investigation of ion irradiation on plasma-facing components including the first mirror of plasma optical diagnostics system. Under the optimum operating condition for mirror testing, the ion source has a beam energy of 200 eV and a current density of 3.7 mA/cm2. The ion source comprises a magnetic cusp-type plasma source, an extraction system, a target system with a Faraday cup, and a power supply control system to ensure stable long time operation. Operation parameters of plasma source such as pressure, filament current, and arc power with D2 discharge gas were optimized for beam extraction by measuring plasma parameters with a Langmuir probe. The diode electrode extraction system was designed by IGUN simulation to optimize for 1 µP perveance. It was successfully demonstrated that the ion beam current of ~4 mA can be extracted through the 10 mm aperture from the developed ion source. The target system with the Faraday cup is also developed to measure the beam current. With the assistance of the power control system, ion beams are extracted while maintaining a consistent arc power for more than 10 min of continuous operation.

A Study on Human-Robot Interface based on Imitative Learning using Computational Model of Mirror Neuron System (Mirror Neuron System 계산 모델을 이용한 모방학습 기반 인간-로봇 인터페이스에 관한 연구)

  • Ko, Kwang-Enu;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.6
    • /
    • pp.565-570
    • /
    • 2013
  • The mirror neuron regions which are distributed in cortical area handled a functionality of intention recognition on the basis of imitative learning of an observed action which is acquired from visual-information of a goal-directed action. In this paper an automated intention recognition system is proposed by applying computational model of mirror neuron system to the human-robot interaction system. The computational model of mirror neuron system is designed by using dynamic neural networks which have model input which includes sequential feature vector set from the behaviors from the target object and actor and produce results as a form of motor data which can be used to perform the corresponding intentional action through the imitative learning and estimation procedures of the proposed computational model. The intention recognition framework is designed by a system which has a model input from KINECT sensor and has a model output by calculating the corresponding motor data within a virtual robot simulation environment on the basis of intention-related scenario with the limited experimental space and specified target object.

Design and Fabrication of Sputter Coating System for Ophthalmic Lens (안경렌즈코팅용 소형 Sputter Coating System 설계 및 제작에 관한 연구)

  • Park, Moonchan;Jung, Boo Young;Kim, Eung Sun;Lee, Jong Geun;Joo, Kyung Bok;Moon, Hee Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.53-58
    • /
    • 2008
  • Purpose: To design and fabricate the small sputter coating system for the Ophthalmic lens. Methods: The design of sputter target was done using macleod program for AR coating and mirror coating of Ophthalmic lens with Si target and then the sputter system was fabricated. Results: The optimum condition of AR coating with Si target was [air|$SiO_2$(81.3)|$Si_3N_4$ (102)|$SiO_2$(19.21)|$Si_3N_4$(15.95)|$SiO_2$(102)|glass], for blue color mirror coating [air|$SiO_2$(56.61)|$Si_3N_4$(135.86)|$SiO_2$(67.64)|$Si_3N_4$(55.4)|$SiO_2$(53.53)|$Si_3N_4$(51.28)|glass], for green color coating [air|$SiO_2$(66.2)|$Si_3N_4$(22.76)|$SiO_2$(56.58)|$Si_3N_4$(140.35)|$SiO_2$(152.35)|$Si_3N_4$(70.16)|$SiO_2$(121.87)|glass], for gold color [air|$SiO_2$(83.59)|$Si_3N_4$(144.86)|$SiO_2$(11.82)|$Si_3N_4$(129.93)|$SiO_2$(90.01)|$Si_3N_4$(88.37)|glass]. Conclusions: In the fabrication of sputtering coating apparatus, Dual cathode with same Ti target were coated at the same time on both sides of Ophthalmic lens to lessen the time of coating on Ophthalmic Lens and save the cost of the lens. The distance of target-substrate of cathode was variable from 12.5 cm to 20 cm. Turbo pump was used to take the whole coating process about 15 min. instead of diffusion pump. The lens holder was made to coat 2 pairs lens every coating and was rotated to get the uniformity of thin film.

  • PDF

The Indoor Position Detection Method using a Single Camera and a Parabolic Mirror (볼록 거울 및 단일 카메라를 이용한 실내에서의 전 방향 위치 검출 방법)

  • Kim, Jee-Hong;Kim, Hee-Sun;Lee, Chang-Goo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.2
    • /
    • pp.161-167
    • /
    • 2008
  • This article describes the methods of a decision of the location which user points to move by an optical device like a laser pointer and a moving to that location. Using a conic mirror and CCD camera sensor, a robot observes a spot of user wanted point among an initiative, computes the location and azimuth and moves to that position. This system offers the brief data to a processor with simple devices. In these reason, we can reduce the time of a calculation to process of images and find the target by user point for carrying a robot. User points a laser spot on a point to be moved so that this sensor system in the robot, detecting the laser spot point with a conic mirror, laid on the robot, showing a camera. The camera is attached on the robot upper body and fixed parallel to the ground and the conic mirror.

Development of Optical Sighting System for Moving Target Tracking

  • Jeung, Bo-Sun;Lim, Sung-Soo;Lee, Dong-Hee
    • Current Optics and Photonics
    • /
    • v.3 no.2
    • /
    • pp.154-163
    • /
    • 2019
  • In this study, we developed an optical sighting system capable of shooting at a long-distance target by operating a digital gyro mirror composed of a gyro sensor and an FSM. The optical sighting system consists of a reticle part, a digital gyro mirror (FSM), a parallax correction lens, a reticle-ray reflection mirror, and a partial reflection window. In order to obtain the optimal volume and to calculate the leading angle range according to the driving angle of the FSM, a calculation program using Euler rotation angles and a three-dimensional reflection matrix was developed. With this program we have confirmed that the horizontal leading angle of the developed optical sighting system can be implemented under about ${\pm}8^{\circ}$ for the maximum horizontal driving angle (${\beta}={\pm}12.5^{\circ}$) of the current FSM. Also, if the ${\beta}$ horizontal driving angle of the FSM is under about ${\pm}15.5^{\circ}$, it can be confirmed that the horizontal direction leading angle can be under ${\pm}10.0^{\circ}$. If diagonal leading angles are allowed, we confirmed that we can achieve a diagonal leading angle of ${\pm}10.0^{\circ}$ with a vertical driving angle ${\alpha}$ of ${\pm}7.1^{\circ}$ and horizontal driving angle ${\beta}$ of ${\pm}12.5^{\circ}$.

Alignment estimation performance of Multiple Design Configuration Optimization for three optical systems

  • Oh, Eun-Song;Kim, Seong-Hui;Kim, Yun-Jong;Lee, Han-Shin;Kim, Sug-Whan
    • Bulletin of the Korean Space Science Society
    • /
    • 2011.04a
    • /
    • pp.31.1-31.1
    • /
    • 2011
  • In this study, we investigated alignment state estimation performances of the three methods i.e. merit function regression (MFR), differential wavefront sampling (DWS) and Multiple Design Configuration Optimization (MDCO). The three target optical systems are 1) a two-mirror Cassegrain system for deep space Earth observation, 2) intermediate size three-mirror anastigmat for Earth ocean monitoring, and 3) extremely large segmented optical system for astronomical observation. We ran alignment state estimation simulation for several alignment perturbation cases including 1mm to 10mm in decenter and from 0.1 to 1 degree in tilt perturbation error for the two-mirror Cassegrain system. In general, we note that MDCO shows more competitive estimation performance than MFR and DWS. The computational concept, case definition and the simulation results are discussed with implications to future works.

  • PDF