This paper is the result of a comparative analysis of crew members' workloads using the EMG and OWAS methods according to the fishing process before and after the improvement of the operating system of the experimental vessel, with the aim of improving operational efficiency and safety work of coastal improved stow net fishing vessels. The target crew members were three people with at least five years of experience on board the same fishing vessel as the experimental vessel. After improving the operating system, such as installing a power block crane and two capstans, change the location of the ball-roller, the time required for setting and hauling work decreased (p < .01), and the evaluation results by OWAS showed that the overall workload for setting and hauling net work decreased. The results of muscle activity analysis showed a decrease in lashing anchor work (p < .01) in the case of hauling net and in anchor dropping work in the case of setting net (p < .001). It is judged that the use of ball rollers in net handling has been reduced; consequently, work safety has been improved.
Kauweloa, Kevin I.;Park, Justin C.;Sandhu, Ajay;Pawlicki, Todd;Song, Bongyong;Song, William Y.
한국의학물리학회지:의학물리
/
제24권4호
/
pp.220-229
/
2013
Respiratory-induced dynamic tumors render free-breathing cone-beam computed tomography (FBCBCT) images with motion artifacts complicating the task of quantifying the internal target volume (ITV). The purpose of this paper is to study the visibility of the revealed ITV when the imaging dose parameters, such as the kVp and mAs, are varied. The $Trilogy^{TM}$ linear accelerator with an On-Board Imaging ($OBI^{TM}$) system was used to acquire low-imaging-dose-mode (LIDM: 110 kVp, 20 mA, 20 ms/frame) and high-imaging-dose-mode (HIDM: 125 kVp, 80 mA, 25 ms/frame) FBCBCT images of a 3-cm diameter sphere (density=0.855 $g/cm^3$) moving in accordance to various sinusoidal breathing patterns, each with an unique inhalation-to-exhalation (I/E) ratio, amplitude, and period. In terms of image ITV contrast, there was a small overall average change of the ITV contrast when going from HIDM to LIDM of $6.5{\pm}5.1%$ for all breathing patterns. As for the ITV visible volume measurements, there was an insignificant difference between the ITV of both the LIDM- and HIDM-FBCBCT images with an average difference of $0.5{\pm}0.5%$, for all cases, despite the large difference in the imaging dose (approximately five-fold difference of ~0.8 and 4 cGy/scan). That indicates that the ITV visibility is not very sensitive to changes in imaging dose. However, both of the FBCBCT consistently underestimated the true ITV dimensions by up to 34.8% irrespective of the imaging dose mode due to significant motion artifacts, and thus, this imaging technique is not adequate to accurately visualize the ITV for image guidance. Due to the insignificant impact of imaging dose on ITV visibility, a plausible, alternative strategy would be to acquire more X-ray projections at the LIDM setting to allow 4DCBCT imaging to better define the ITV, and at the same time, maintain a reasonable imaging dose, i.e., comparable to a single HIDM-FBCBCT scan.
목 적: 온보드 영상장치(OBI) 및 콘빔 CT (CBCT)를 이용하면 치료실에 위치한 환자의 자세 및 위치와 모의치료(SIMULATION) 시점의 환자의 자세 및 위치를 비교할 수 있다. Detected offsets은 실제로 적용된 인체팬톰(Rando phantom) 위치의 오차와 비교되어 진다. 이후, 인체 팬톰은 detected 오차에 근거하여 couch를 움직여 위치선정 되었다. 또한 인체팬톰 위치 결정의 실측값과 이론값 오차값들을 비교하였으며, OBI를 사용하고 있는 KV X선영상의 2D와 CBCT의 3D 타켓 위치 정확성 평가하고자 한다. 대상 및 방법: 신체 내부 구조가 모사된 팬톰(The Rando Phantom, Alderson Resarch Laboratories Inc. Stamford. CT, USA)을 사용하여 실제방사선 치료와 동일한 과정을 따라 모의치료(SIMULATION) 및 치료계획(RTP)을 시행한 후 치료 데이블 위에 인체 팬톰을 셋업한다. 정확히 위치가 재현된다고 가정되는 인체팬톰에 대해 3가지 방법으로 실험을 했는데 X, Y, Z축의 변화에 따라 셋업 오차를 측정했고 각각의 실험은 10회씩 반복되어 오차의 표준 편차를 구했다. DigiPas DWL-80G는 기울기의 각을 결정하기 위해 사용하였으며, 2D/2D 및 3D/3D정합의 실측치와 측정치를 비교 분석 하였다. 결 과: 온보드 영상장치로 획득한 정면 및 측면 kv x선 영상과 모의치료시 디지털 재구성 기준영상과의 2차원/2차원 정합시, 팬톰의 X, Y, Z 편차 평균값은 lat 0.12 cm, long -0.66 cm, vert 0.07 cm이며, 각도의 변화를 주었을 때 편차의 평균값은 lat -0.5 cm, long -0.3 cm, 팬톰의 몸을 약간 튼 상태에서의 편차 평균값은 각각 lat -0.5 cm, long 0.2 cm, vert -0.6 cm으로 나타났다. 또한 콘빔CT로 획득한 영상과 모의치료 시 획득한 CT영상을 비교하는 3차원/3차원 정합에서 팬톰의 3가지 방법에서 편차의 평균 detection error와 표준편차는 lateral $0.5{\pm}0.4\;mm$, longitudinal $0.8{\pm}0.5\;mm$, vertical $0.4{\pm}0.3\;mm$로 각각 0-10 mm의 범위이다. Residual error에 해당되는 positioning couch shift 변수는 $0.6{\pm}0.3\;mm$, $0.5{\pm}0.3\;mm$, $0.3{\pm}0.1\;mm$이다. 20-50 mm까지 longitudinal shift에 의한 평균 detection error는 각각 lateral $0.4{\pm}0.2\;mm$, longitudinal $0.3{\pm}0.2\;mm$, vertical $0.3{\pm}0.3\;mm$이다. Residual error는 $0.6{\pm}0.3\;mm$, $0.6{\pm}0.2\;mm$, $0.4{\pm}0.1\;mm$이다. Detection error는 모두 0.0~0.6 mm 범위이다. Residual error는 0.3~0.9 mm 범위로 나타났다. 결 론: 온보드 영상장치(OBI) 및 콘빔 CT (CBCT)를 이용하여 표적위치의 정확성을 평가하였다. 치료실에 위치한 환자의 자세 및 위치와 모의치료(SIMULATION) 시점의 환자의 자세 및 위치를 비교할 수 있다. 그러므로 OBI 및 CBCT를 이용한 2D/2D 및 3D/3D 정합은 모의 치료 시와 환자 치료 시 정확한 정합을 함으로써 error를 최소화 할 것으로 평가된다.
본 논문은 장애물을 인식하고 회피하면서 목적지까지 자율적으로 이동할 수 있는 로봇을 구현한 논문이다. 우리는 본 논문에서 영상처리보드의 구현이라는 하드웨어적인 부분과 자율 이동로봇을 위한 영상궤환 제어라는 소프트웨어의 두 가지 결과를 나타내었다. 첫 번째 부분에서, 영상처리를 수행하는 제어보드로부터 명령을 받는 로봇을 나타내었다. 우리는 오랫동안 CCD카메라를 탑재한 자율 이동로봇에 대하여 연구해왔다. 로봇의 구성은 DSP칩을 탑재한 영상보드와 스텝모터 그리고 CCD카메라로 구성된다. 시스템 구성은 이동로봇의 영상처리 보드에서 영상을 획득하고 영상처리 알고리즘을 수행하고 로봇의 이동경로를 계산한다. 이동로봇에 탑재된 CCD카메라에서 획득한 영상 정보는 매 샘플링 시간마다 캡쳐한다. 화면에서 장애물의 유무를 판별한 후 좌 혹은 우로 회전하여 장애물을 회피하고 이동한 거리를 Feedback하는 시스템을 구현하여 초기에 지정한 목표지점가지 로봇이 갈 수 있도록 간략한 경로를 계획하여 절대좌표를 추적해 나가는 알고리즘을 구현한다. 이러한 영상을 획득하고 알고리즘을 처리하는 영상처리 보드의 구성은 DSP (TMS320VC33), ADV611, SAA7111, ADV7176A, CPLD(EPM7256ATC144), SRAM 메모리로 구성되어 있다. 두 번째 부분에서는 장애물을 인식하고 회피하기 위하여 두 가지의 영상궤환 제어 알고리즘을 나타낸다. 첫 번째 알고리즘은 필터링, 경계검출 NOR변환, 경계치 설정 등의 영상 전처리 과정을 거친 영상을 분할하는 기법이다. 여기에서는 Labeling과 Segmentation을 통한 pixel의 밀도 계산이 도입된다. 두 번째 알고리즘은 위와 같이 전처리된 영상에 웨이브렛 변환을 이용하여 수직방향(y축 성분)으로 히스토그램 분포를 20 Pixel 간격으로 스캔한다. 파형 변화에 의하여 장애물이 있는 부분의 히스토그램 분포는 거의 변동이 없이 나타난다. 이러한 특성을 분석하여 장애물이 있는 곳을 찾아내고 이것을 회피하기 위한 알고리즘을 세웠다. 본 논문은 로봇에 장착된 한 개의 CCD 카메라를 이용하여 장애물을 회피하면서 초기에 설정해둔 목적지가지 도달하기 위한 알고리즘을 제안하였으며, 영상처리 보드를 설계 및 제작하였다. 영상처리 보드는 일반적인 보드보다 빠른 속도(30frame/sec)와 해상도를 지원하며 압축 알고리즘을 탑재하고 있어서 영상을 전송하는 데에 있어서도 탁월한 성능을 보인다.
본 연구에서는 대나무 Zephyr 보드에 있어서 열압조건이 보드의 성능에 미치는 영향을 조사하기 위하여 다양한 열압시간과 열압온도를 적용하여 보드(목표밀도 0.7 g/cm3, 400×400×12 mm)를 제조하고 그 기본적인 물성을 비교, 검토해 보았다. 제조된 보드는 KS F 3104와 KS F 3113에 준하여 성능평가를 하였으며 그 결과는 다음과 같다. 보드의 상태 휨강도는 열압조건에 관계없이 전반적으로 상당히 높은 값을 나타내었으며 그 중 span에 대한 평행 방향에 있어서는 열판온도 160℃에서 12분 동안 열압하여 제조한 보드가 가장 높은 강도를 보였다. 보드의 박리강도 시험에서는 모든 열압시간에서 열압온도가 높을수록 상대적으로 더 높은 값을 나타내었으며, 그 결과 200℃에서 압체된 보드가 가장 높은 강도를 보였다. 보드의 습윤 휨강도 시험에서는 총 열압시간 12분과 10분일 때 각각 160℃와 180℃의 온도에서 제조된 보드가 상대적으로 높은 강도를 나타내었다. 더욱이, 200℃에서 8분 동안 열압하여 제조한 보드의 경우 상태 휨강도에 거의 육박하는 가장 높은 습윤 휨강도를 보였다. 두께 팽창율 시험에서는 모든 보드에서 전반적으로 6% 미만의 낮은 값을 나타내어 높은 치수안정성을 가지는 것을 알 수 있었다.
목 적: 온 보드영상(OBI)장치를 이용한 콘빔CT는 환자 치료 중 실시간으로 전산화모의치료 영상과 비교하여 환자의 자세 및 표적용적의 움직임과 셋업오차를 확인 할 수 있다. IMRT 시 콘빔CT를 이용해 환자의 자세 및 표적용적의 변화와 움직임을 확인하여 치료계획과의 오차정도를 산출하고, Automatic Match System을 이용하여 위치 보정을 한 후 전자포털영상 장치를 통하여 위치보정의 정확성을 검증하고, IMRT에서 콘빔CT의 유용성과 Automatic Match System의 정확성에 대하여 알아보고 자 한다. 대상 및 방법: 본원에서 치료받은 IMRT 환자 중 두 경부 치료환자 3명, 골반부 치료환자 1명을 대상으로 치료 자세의 변동과 그에 따른 조사용적의 위치변동을 알아보기 위해 선형가속기에 장착된 온 보드 영상 장치를 이용해 콘빔 CT를 촬영하였다. IMRT 전 매 치료 시 마다 콘빔CT를 촬영하여 전산화단층모의치료 영상과 비교하여 좌표별로 치료계획과의 오차값을 확인하고 3D/3D Match의 Automatic Match System을 통하여 치료계획과 일치하도록 이동 보정한 후 전자포털영상 장치를 이용하여 검증, 평가하였다. 결 과: 치료 전 콘빔 CT와 전산화단층모의치료 영상 비교 시 두 경부에서 좌표별 평균오차는 Vertical 0.99 mm, Longitudinal 1.14 mm, Lateral 0.84 mm, Rotation $0.49^o$이고, 골반부의 평균오차는 Vertical 2.78 mm, Longitudinal 2.04 mm, Lateral 4.91 mm, Rotation $1.07^o$로 부위별로 다소 근소한 차이를 보였다. 보정 후 검증에서는 전자포털영상 장치에 의한 영상과 DRR 영상 비교 결과 0.5 mm 이내의 오차로 정확한 보정이 이루어졌음을 알 수 있었다. 결 론: 치료 전 콘빔CT 영상은 환자의 셋업오차와 장기 및 표적의 위치변화를 2차원적 영상의 비교와 달리 하나의 체적으로 재구성된 3차원적 영상으로 비교함으로써 보다 정확하게 위치변화와 표적용적의 변동 등을 측정, 보정하여 정확한 치료를 할 수 있으며, 그 오차 값을 산출하여 비교할 수 있다. 이상의 연구로 보아 콘빔CT는 치료계획과 일치하는 정확한 치료전달과 반복적인 치료재현성에 유용하였으며, 만족스러운 결과를 얻을 수 있었다. 콘빔CT에 의해 향상된 정확도는 복잡한 모양의 표적용적과 급격한 선량분포의 변화가 나타나는 IMRT에서 더욱 필요하며 각 치료 부위별, 치료 목적별로 Match focus에 대한 기준을 연구해야 될 것으로 사료된다.
Background: Multidisciplinary team care (MTC) is a collaborative approach to treatment plan and ongoing care. We aimed to evaluate the clinical effect of MTC on the regulation of chronic kidney disease-mineral and bone disorder (CKD-MBD) complications in dialysis patients. Methods: This retrospective observational study was approved by the institutional review board. Among patients who have undergone dialysis at admission, the patients admitted to the nephrology ward were allocated to MTC group, and the others to usual care (UC) group. The MTC group had collaborative care by nephrologists, nurses, pharmacists, and nutritionists. The endpoints were the regulation of corrected calcium (cCa) and phosphate (P), the percent of patients in target level of cCa-P product ($cCa{\times}P$), and the prescription rate of non-calcium based P-binders. Results: A total of 163 patients were included from January to December 2009. A significant difference was shown in the percentage of patients in target $cCa{\times}P$ level at admission (MTC vs. UC, 81.40% vs. 91.67%; P = 0.038), but there was no significant difference at discharge. During admission, the cCa and P levels of patients in only UC group were significantly changed. In addition, compared with UC group, patients in MTC group were more likely prescribed appropriate P-binders, when they had higher $cCa{\times}P$ levels than $55mg^2/dL^2$ (P <0.001). Conclusion: It was found that MTC had beneficial effect on improving the regulation of CKD-MBD and the appropriate phosphate binder uses. Therefore, application of the MTC is anticipated to enhance quality of clinical care in chronic diseases.
본 논문은 저비용이면서 정확한 제어를 수행하는 새로운 퍼지 제어기의 VHDL 설계 및 FPGA 구현을 자동적으로 수행하는 통합 개발환경(IDE : Integrated Development Environment)을 다룬다. 이를 위해 FLC의 자동 설계 및 구현의전 과정을 하나의 환경 내에서 개발 가능하게 하는 퍼지 제어기 자동 설계 및 구현 시스템(FLC Automatic Design and Implementations Station : FADIS)을 개발하였는데 이 시스템은 다음 기능을 포함한다. (1) 원하는 퍼지 제어기의 설계 파라메터를 입력받아 이로부터 FLC를 구성하는 각 모듈의 VHDL 코드를 자동적으로 생성한다. (2) 생성된 각 모듈의 VHDL 코드가 원하는 동작을 수행하는지를 Synopsys사의 VHDL Simulator상에서 시뮬레이션을 수행한다. (3) Synopsys사의 FPGA Compiler에 의해 VHDL 코드를 합성하여 FLC의 각 구성 모듈을 얻는다. (4) 합성된 모듈은 Xilinx사의 XactStep 6.0에 의해 최적화 및 배치, 배선이 이루어진다. (5) 얻어진 Xilinx rawbit파일은 VCC사의 r2h에 의해 C언어의 header파일 형태의 하드웨어 object 로 변환된다. (6) 하드웨어 object를 포함하는 응용 제어 프로그램의 실행파일을 재구성 가능한 FPGA시스템 상에 다운로드한다. (7) 구현된 FLC의 동작 과정은 구현된 FLC와 제어 target사이의 상호통신에 의해 모니터링한다. 트럭 후진 주차 제어에 사용하는 퍼지 제어기 설계 및 구현의 전 과정을 FADIS상에서 수행하여 FADIS가 완전하게 동작하는지를 확인하였으며, FCL를 FPGA상에 구현함에 따른 제어 시간의단축을 다른 구현의 경우와 비교하였다.
본 논문에서는 TRM(Transmitter-Receiver Module)을 사용하여 각 안테나에 펄스의 위상을 조정함으로써 빔 패턴 각도를 조정하여 다중 경로 환경에서의 성능저하를 향상시킬 수 있다. 다중 경로 환경에서 성능저하를 향상시키는 임펄스 신호를 왜곡 없이 송 수신하는 빔 스캐닝 시스템(Beam Scanning System)을 설계 및 제작 하였다. 빔 스캐닝 시스템은 안테나 종단 부분에서 신호가 왜곡 없이 송 수신이 가능하여 하며 타 시스템에 영향을 미치지 않아야 한다. 또한 빔 조향을 통하여 표적에 대한 감지 능력도 있어야 한다. 설계한 빔 스캐닝 안테나의 분산특성은 충실도(Fidelity)를 사용하여 분석을 하고 조향과 레이더 해상도(Radar Resolution) 성능은 $1cm{\times}1cm$ 표적의 크기를 사용하여 그 성능을 확인한다. 빔 스캐닝 배열 안테나를 제작하기 위해 IR-UWB(Impulse Radio)용 비발디 안테나(Vivaldi Antenna), 삼중대역 윌킨슨 전력 분배기(Tri-Band Wilkinson power divider), TRM(Transmitter-Receiver Module), 송 수신 모듈(TRM)을 컨트롤 할 수 있는 컨트롤 보드 및 GUI 설계를 하였다. 본 연구를 통해 개발된 UWB 빔 스캐닝 시스템은 빔 패턴 각도를 조정하여 다중 경로 환경에서의 성능저하를 향상시킬 수 있으며, 네트워크 분석기를 이용한 시간영역 분석기술은 안테나 설계 시 안테나의 특성을 정확히 분석을 할 수 있고 손쉽게 빔 폭을 확인 할 수가 있다. 설계한 빔 스캐닝 시스템은 레이더 응용 분야인 지표투과 레이더, 벽 투과 레이더, 의료영상 레이더, 탐색 및 구조 레이더, 비파괴 탐상 레이더 및 무선통신 시스템에 사용 적용이 가능하다.
Climate change is one of the biggest dangers facing all living creatures in the earth. It has been understood that emissions of greenhouse gases from human activity is the cause of climate change. Cars are responsible for around 12% of total EU emissions of CO2, the main greenhouse gas. The United Nations Framework Convention on Climate Change (UNFCCC or FCCC) is an international environmental treaty adopted at the United Nations Conference on Environment and Development (UNCED) on 9 May, 1992, which entered into force on 21 March 1994. The European Commission first adopted a Community Strategy to reduce CO2 emissions from cars in 1995. On 19 December 2007, the European Commission proposed "Proposal for Setting emission performance standards for new passenger cars to reduce CO2 emissions", which was adopted on 23 April 2009 as "Regulation (EC) No 443/2009". Prior to submitting the Proposal, the European Commission performed impact assessment and prepared impact assessment report which was reviewed by the Impact Assessment Board. The objective of this Regulation is to set emission performance standards for new passenger cars registered in the Community, which forms part of the Community's integrated approach to reducing CO2 emissions from light-duty vehicles while ensuring the proper functioning of the internal market. In the event that a manufacturer fails to meet its target, it will be required to pay an excess emissions premium in respect of each calendar year from 2012 onwards. On 11 March 2014, Regulation (EC) No 333/2014 amending Regulation (EC) No 443/2009 was adopted. Regulation (EC) No 333/2014 amends Regulation (EC) No 443/2009 to implement the modalities of meeting the 95g CO2/km target for new passenger cars to be reached in 2020. As industry benefits from indications of the regulatory regime that would apply beyond 2020, the Regulation includes a further review to take place by, at the latest, 31 December 2014.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.