• Title/Summary/Keyword: Target Coverage

Search Result 303, Processing Time 0.029 seconds

Dosimetric comparison of intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) in total scalp irradiation: a single institutional experience

  • Ostheimer, Christian;Hubsch, Patrick;Janich, Martin;Gerlach, Reinhard;Vordermark, Dirk
    • Radiation Oncology Journal
    • /
    • v.34 no.4
    • /
    • pp.313-321
    • /
    • 2016
  • Purpose: Total scalp irradiation (TSI) is a rare but challenging indication. We previously reported that non-coplanar intensity-modulated radiotherapy (IMRT) was superior to coplanar IMRT in organ-at-risk (OAR) protection and target dose distribution. This consecutive treatment planning study compared IMRT with volumetric-modulated arc therapy (VMAT). Materials and Methods: A retrospective treatment plan databank search was performed and 5 patient cases were randomly selected. Cranial imaging was restored from the initial planning computed tomography (CT) and target volumes and OAR were redelineated. For each patients, three treatment plans were calculated (coplanar/non-coplanar IMRT, VMAT; prescribed dose 50 Gy, single dose 2 Gy). Conformity, homogeneity and dose volume histograms were used for plan. Results: VMAT featured the lowest monitor units and the sharpest dose gradient (1.6 Gy/mm). Planning target volume (PTV) coverage and homogeneity was better in VMAT (coverage, 0.95; homogeneity index [HI], 0.118) compared to IMRT (coverage, 0.94; HI, 0.119) but coplanar IMRT produced the most conformal plans (conformity index [CI], 0.43). Minimum PTV dose range was 66.8%-88.4% in coplanar, 77.5%-88.2% in non-coplanar IMRT and 82.8%-90.3% in VMAT. Mean dose to the brain, brain stem, optic system (maximum dose) and lenses were 18.6, 13.2, 9.1, and 5.2 Gy for VMAT, 21.9, 13.4, 14.5, and 6.3 Gy for non-coplanar and 22.8, 16.5, 11.5, and 5.9 Gy for coplanar IMRT. Maximum optic chiasm dose was 7.7, 8.4, and 11.1 Gy (non-coplanar IMRT, VMAT, and coplanar IMRT). Conclusion: Target coverage, homogeneity and OAR protection, was slightly superior in VMAT plans which also produced the sharpest dose gradient towards healthy tissue.

KMTNet Supernova Project : The Initial Status

  • Kim, Sang Chul;Moon, Dae-Sik;Lee, Jae-Joon;Pak, Mina
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.56.1-56.1
    • /
    • 2015
  • We are at the initial performance-verification phase of our KMTNet Supernova Project (KSP) using the three wide-field telescopes of the KMTNet in the southern hemisphere. The primary science objectives of KSP, which take advantage of its unique 24-hour continuous sky coverage, are to study early (i.e., within a few hours from explosion) and rare/peculiar (e.g. fast decay) supernovae (SNe), SN progenitors, explosion mechanisms, as well as other exotic optical transients. We present the initial status/results of the program, along with the program strategy, science objectives, target fields, and future plan. While the target field selection will be made based on the performance of the system and consideration of various scientific merits, the initial target fields are focused on nearby galaxies with increased cadence and filter coverage.

  • PDF

EBKCCA: A Novel Energy Balanced k-Coverage Control Algorithm Based on Probability Model in Wireless Sensor Networks

  • Sun, Zeyu;Zhang, Yongsheng;Xing, Xiaofei;Song, Houbing;Wang, Huihui;Cao, Yangjie
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.8
    • /
    • pp.3621-3640
    • /
    • 2016
  • In the process of k-coverage of the target node, there will be a lot of data redundancy forcing the phenomenon of congestion which reduces network communication capability and coverage, and accelerates network energy consumption. Therefore, this paper proposes a novel energy balanced k-coverage control algorithm based on probability model (EBKCCA). The algorithm constructs the coverage network model by using the positional relationship between the nodes. By analyzing the network model, the coverage expected value of nodes and the minimum number of nodes in the monitoring area are given. In terms of energy consumption, this paper gives the proportion of energy conversion functions between working nodes and neighboring nodes. By using the function proportional to schedule low energy nodes, we achieve the energy balance of the whole network and optimizing network resources. The last simulation experiments indicate that this algorithm can not only improve the quality of network coverage, but also completely inhibit the rapid energy consumption of node, and extend the network lifetime.

Finding a Second Best Coverage Path (차선거리유지 경로찾기)

  • Na, Hyeon-Suk;Kim, Jung-Hee
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.35 no.8
    • /
    • pp.385-393
    • /
    • 2008
  • The best coverage problem is finding a path whose worst distance to the sensor-set is the best among all paths. Instead, if the user stays close to its nearest two sensors, then the stability of the wireless connection may be guaranteed. So we consider the problem of finding a second best coverage path; given the sensor set U, a starting point s and a target point t, find a path whose worst distance to the second closest sensor is minimized. This paper presents an O(n logn) -time algorithm to find such a path. We also give experimental evidence showing that the connection to the sensor-set along a second best coverage path is more stable than that along the best coverage path.

Analysis of spraying performance of agricultural drones according to flight conditions

  • Dae-Hyun Lee;Baek-Gyeom Seong;Seung-Woo Kang;Soo-Hyun Cho;Xiongzhe Han;Yeongho Kang;Chun-Gu Lee;Seung-Hwa Yu
    • Korean Journal of Agricultural Science
    • /
    • v.50 no.3
    • /
    • pp.427-435
    • /
    • 2023
  • This study was conducted to evaluate the spraying performance according to the flight conditions of agricultural drones for the development of a variable control system. The analyzed flight conditions comprised six factors: spraying direction, flight speed, altitude, wind speed, wind direction, and rotor rotational speed. The ratio of the area sprayed on the water-sensitive paper was used as the coverage, and the distribution and amount of the coverage were evaluated. The coverage distribution based on the distance from the drone was used to evaluate a spray pattern, and the distribution was expressed as a Gaussian function approximation. In addition, the probability distribution based on coverage was expressed as the cumulative probability via Gamma function approximation to analyze the spraying efficiency in the target area. The results showed that the averaged coverage decreased significantly as the flight speed and wind speed increased, and the wind direction changed the spray pattern without a coverage decrease. This study contributes to the development of a control technique for the precision control system of agricultural drones.

A Study of Rehabilitation for Limestone Quarry near the Baekdudaegan Mountains (2) - In Case Study for Planting Seedlings Experiment on Okke Quarry - (백두대간에 인접한 석회석 광산의 식생복구 연구 (2) - 묘목식재 방법에 의한 옥계 광산복구 시험시공 사례 -)

  • Kim, Kyunghoon;Kim, Haksung
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.15 no.2
    • /
    • pp.117-125
    • /
    • 2012
  • The objective of this study was to investigate the possibility of planting seedlings for quarry rehabilitation. To achieve the objective, the experiment was designed for rehabilitation of quarry with planting seedlings and seeding types. Planting seedlings were categorized as target species, accompanied species and pioneer species. The study was conducted in limestone quarry (Lafarge Halla Cement Inc.) near the Baekdudaegan Mountains at Okke, Kangwon-do. The experimental planting bed was set in 2007 and field monitoring was carried out from 2007 to 2011. As the result of experiment, it was found that the early-phase pattern for surveyed species to establish was affected by the planting and seeding types. As years after planting and seeding, the percent of plant coverage also increased up to 90%. The methods of mixed planting and seeding were good for species diversity, but the growing of seedlings were affected by seeding plants. Accompanied species and pioneer species were superior to target species during first 2 years, but target species has gained predominance during last 2 years. The quality maintenance should be carried out annually to attain the goal of rehabilitation.

Usability Assessment of Plan Transfer between TOMO HAD and Radixact : Planning Study (TOMO HDA와 Radixact 치료 계획 간 Transfer에 대한 유용성 평가 : Planning Study)

  • An, Ye Chan;Kim, Jong Sik;Kwon, Dong Yeol;Kim, Jin Man;Choi, Byeong Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.117-128
    • /
    • 2018
  • Purpose : To evaluate the usability of plan transfer between TOMO HD and Radixact, we compared the differences of dose in transferred plans by evaluating the dose of normal organ and target. TOMO HDA and Radixact. The completed plans were transferred each other and we compared the differences of dose by evaluating the DVH of each plans. Materials and Methods : We planned 4 different plans assuming the treatment of 2 cases in Head and Neck Cancer and 2 cases Prostate cancer. Each plan was designed so that 95 % of the prescription dose was irradiated over 99 % of the target volume, and the normal organ constraints dose was based on the SMC tolerance dose protocol. Each plan was transferred to each equipment and DVH(dose volume histogram) analysis of the transferred plans was compared and evaluated. Results : The Mean dose of CTV and GTV was increased and decreased in the transferred plans, but there was no significant differences. The target coverage of CTV and GTV was decreased in all cases of transferred plans from TOMO HAD to Radixact, and the change of CI and HI in CTV was within 0.1. Normal organ dose was increased in most cases when transferring from HAD to Radixact in both treatment plans. Conclusion : According to the results of this experiment, the target coverage was above the standard and the normal organ dose was almost same or decreased when transferring the plans from Radixact to HDA equipment. However the target coverage was reduced when transferring the plans from HDA to Radixact and there was an increase in dose in normal organs that could cause sever side effects such as Optic Chiasm ($D_{max}$1.38 Gy), Bladder ($D_{max}$3.07 Gy), Penile Bulb ($D_{max}$1.14 Gy). Therefore, it is necessary to pay attention to the dose change when transferring the plan and one-time transfer due to equipment inspection will be useful for efficient radiation therapy, but if the transferred treatment plans continue for several consecutive days, the treatment plan should be resumed.

  • PDF

Clustering for Improved Actor Connectivity and Coverage in Wireless Sensor and Actor Networks (무선 센서 액터 네트워크에서 액터의 연결성과 커버리지를 향상시키기 위한 클러스터 구성)

  • Kim, Young-Kyun;Jeon, Chang-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.8
    • /
    • pp.63-71
    • /
    • 2014
  • This paper proposes an algorithm that forms the clusters on the basis of hop distance in order to improve the actor coverage and connectivity in the sink-based wireless sensor and actor networks. The proposed algorithm forms the clusters that are distributed evenly in the target area by electing the CHs(Cluster Heads) at regular hop intervals from a sink. The CHs are elected sequentially from the sink in order to ensure the connectivity between the sink and the actors that are located on the CHs. Additionally, the electing are achieved from the area of the higher rate of the sensors density in order to improve the actor coverage. The number of clusters that are created in the target area and the number of the actors that are placed on the positions of the CHs are reduced by forming the clusters with regular distribution and minimizing the overlap of them through the proposed algorithm. Simulations are performed to verify that the proposed algorithm constructs the actor network that is connected to the sink. Moreover, we shows that the proposed algorithm improves the actor coverage and, therefore, reduces the amount of the actors that will be deployed in the region by 9~20% compared to the IDSC algorithm.

The Dosimetric Effect on Real PTV and OARs at Various Image Fusion Protocol for Pituitary Adenomas (뇌하수체 종양의 방사선 수술 시 영상 융합 프로토콜이 실제 PTV와 OAR 선량에 미치는 영향)

  • Lee, Kyung-Nam;Lee, Dong-Joon;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.354-359
    • /
    • 2010
  • The purpose of this study is to verify the dosimetric effect on real PTV (planning target volume) coverage and safety of OARs (organs at risk) at various image fusion protocol-based radiosurgery plan for pituitary adenomas. Real PTV coverage and its variation was acquired and maximum dose and the volume absorbing above threshold dose were also measured for verifying the safety of optic pathway and brainstem. The protocol that can reduce superior-inferior uncertainty by using both axial and coronal MR (magnetic resonance) image sets shows relatively lower values than that of case using only axial image sets. As a result, the image fusion protocol with both axial and coronal image sets can be beneficial to generate OAR-weighted radiosurgery plan.

Study on the Coverage by COMS OCI FOV

  • Kang C. H.;Seo S. B.;Lim H. S.;Park D. J.;Ahn S. I.;Koo I. H.;Hyun D. H.;Yang H. M.;Choi H. J.
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.336-339
    • /
    • 2004
  • Communication, Ocean and Meteorological Satellite (COMS) has been developed by Korean Aerospace Research Institute (KARI) since 2003. Ocean Color Imager (OCI) is the one of COMS payloads, which will monitor the marine environment around Korean peninsula routinely with the intermediate resolution. But considering COMS is to be located in the geostationary orbit, required geographical coverage is not positioned in the nadir direction of COMS but in specific location with horizontal and vertical offsets from the nadir. In this study, coverage by OCI Field Of View (FOV) is analyzed. First of all, OCI is modeled as the sensor which is a $2,500{\times}2,500$ sized 2-D CCD and the pixel resolution is about 500m. And then, OCI is simulated to be controlled to target the required coverage accurately. As a result of it, coverage by OCI FOV is determined. Finally, all coverages by OCI FOV are mapped.

  • PDF