Evaluation of Setup Uncertainty on the CTV Dose and Setup Margin Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 셋업오차가 임상표적체적에 전달되는 선량과 셋업마진에 대하여 미치는 영향 평가)

  • Cho, Il-Sung;Kwark, Jung-Won;Cho, Byung-Chul;Kim, Jong-Hoon;Ahn, Seung-Do;Park, Sung-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.81-90
    • /
    • 2012
  • The effect of setup uncertainties on CTV dose and the correlation between setup uncertainties and setup margin were evaluated by Monte Carlo based numerical simulation. Patient specific information of IMRT treatment plan for rectal cancer designed on the VARIAN Eclipse planning system was utilized for the Monte Carlo simulation program including the planned dose distribution and tumor volume information of a rectal cancer patient. The simulation program was developed for the purpose of the study on Linux environment using open source packages, GNU C++ and ROOT data analysis framework. All misalignments of patient setup were assumed to follow the central limit theorem. Thus systematic and random errors were generated according to the gaussian statistics with a given standard deviation as simulation input parameter. After the setup error simulations, the change of dose in CTV volume was analyzed with the simulation result. In order to verify the conventional margin recipe, the correlation between setup error and setup margin was compared with the margin formula developed on three dimensional conformal radiation therapy. The simulation was performed total 2,000 times for each simulation input of systematic and random errors independently. The size of standard deviation for generating patient setup errors was changed from 1 mm to 10 mm with 1 mm step. In case for the systematic error the minimum dose on CTV $D_{min}^{stat{\cdot}}$ was decreased from 100.4 to 72.50% and the mean dose $\bar{D}_{syst{\cdot}}$ was decreased from 100.45% to 97.88%. However the standard deviation of dose distribution in CTV volume was increased from 0.02% to 3.33%. The effect of random error gave the same result of a reduction of mean and minimum dose to CTV volume. It was found that the minimum dose on CTV volume $D_{min}^{rand{\cdot}}$ was reduced from 100.45% to 94.80% and the mean dose to CTV $\bar{D}_{rand{\cdot}}$ was decreased from 100.46% to 97.87%. Like systematic error, the standard deviation of CTV dose ${\Delta}D_{rand}$ was increased from 0.01% to 0.63%. After calculating a size of margin for each systematic and random error the "population ratio" was introduced and applied to verify margin recipe. It was found that the conventional margin formula satisfy margin object on IMRT treatment for rectal cancer. It is considered that the developed Monte-carlo based simulation program might be useful to study for patient setup error and dose coverage in CTV volume due to variations of margin size and setup error.

HVL Measurement of the Miniature X-Ray Tube Using Diode Detector (다이오드 검출기를 이용한 초소형 X선관(Miniature X-ray Tube)의 반가층 측정)

  • Kim, Ju-Hye;An, So-Hyeon;Oh, Yoon-Jin;Ji, Yoon-Seo;Huh, Jang-Yong;Kang, Chang-Mu;Suh, Hyunsuk;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.279-284
    • /
    • 2012
  • The X ray has been widely used in both diagnosis and treatment. Recently, a miniature X ray tube has been developed for radiotherapy. The miniature X ray tube is directly inserted into the body irradiated, so that X rays can be guided to a target at various incident angles according to collimator geometry and, thus, minimize patient dose. If such features of the miniature X ray tube can be applied to development of X ray imaging as well as radiation treatment, it is expected to open a new chapter in the field of diagnostic X ray. However, the miniature X ray tube requires an added filter and a collimator for diagnostic purpose because it was designed for radiotherapy. Therefore, a collimator and an added filter were manufactured for the miniature X ray tube, and mounted on. In this study, we evaluated beam characteristics of the miniature X ray tube for diagnostic X ray system and accuracy of measuring the HVL. We used the Si PIN Photodiode type Piranha detector (Piranha, RTI, Sweden) and estimated the HVL of the miniature X ray tube with added filter and without added filter. Through an another measurement using Al filter, we evaluated the accuracy of the HVL obtained from a direct measurement using the automatic HVL calculation function provided by the Piranha detector. As a result, the HVL of the miniature X ray tube was increased around 1.9 times with the added filter mounted on. So we demonstrated that the HVL was suitable for diagnostic X ray system. In the case that the added filter was not mounted on, the HVL obtained from use of the automatic HVL calculation function provided by Piranha detector was 50% higher than the HVL estimated using Al filter. Therefore, the HVL automatic measurement from the Piranha detector cannot be used for the HVL calculation. However, when the added filter was mounted on, the HVL automatic measurement value using the Piranha detector was approximately 15% lower than the estimated value using Al filter. It implies that the HVL automatic measurement can be used to estimate the HVL of the miniature X ray tube with the added filter mounted on without a more complicated measurement method using Al filter. It is expected that the automatic HVL measurement provided by the Piranha detector enables to make kV-X ray characterization easier.

Dosimetric Verifications of the Output Factors in the Small Field Less Than $3cm^2$ Using the Gafchromic EBT2 Films and the Various Detectors (Gafchromic EBT2필름과 다양한 검출기를 이용하여 $3cm^2$ 이하의 소조사면에서 출력비율의 선량검증)

  • Oh, Se An;Yea, Ji Woon;Lee, Rena;Park, Heon Bo;Kim, Sung Kyu
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.218-224
    • /
    • 2014
  • The small field dosimetry is very important in modern radiotherapy because it has been frequently used to treat the tumor with high dose hypo-fractionated radiotherapy or high dose single fraction stereotactic radiosurgery (SRS) with small size target. But, the dosimetry of a small field (< $3{\times}3cm^2$) has been great challenges in radiotherapy. Small field dosimetry is difficult because of (a) a lack of lateral electronic equilibrium, (b) steep dose gradients, and (c) partial blocking of the source. The objectives of this study were to measure and verify with the various detectors the output factors in a small field (<3 cm) for the 6 MV photon beams. Output factors were measured using the CC13, CC01, EDGE detector, thermoluminescence dosimeters (TLDs), and Gafchromic EBT2 films at the sizes of field such as $0.5{\times}0.5$, $1{\times}1$, $2{\times}2$, $3{\times}3$, $5{\times}5$, and $10{\times}10cm^2$. The differences in the output factors with the various detectors increased with decreasing field size. Our study demonstrates that the dosimetry for a small photon beam (< $3{\times}3cm^2$) should use CC01 or EDGE detectors with a small active volume. And also, Output factors with the EDGE detectors in a small field (< $3{\times}3cm^2$) coincided well with the Gafchromic EBT2 films.

Comparison of Anisotropic Analytic Algorithm Plan and Acuros XB Plan for Lung Stereotactic Ablative Radiotherapy Using Flattening Filter-Free Beams (비편평화여과기 빔을 이용한 폐 정위절제방사선치료를 위한 AAA와 Acuros XB 계산 알고리즘의 치료계획 비교)

  • Chung, Jin-Beom;Eom, Keun-Yong;Kim, In-Ah;Kim, Jae-Sung;Lee, Jeong-Woo;Hong, Semie;Kim, Yon-Lae;Park, Byung-Moon;Kang, Sang-Won;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.210-217
    • /
    • 2014
  • This study investigated the dosimetric effects of different dose calculation algorithm for lung stereotactic ablative radiotherapy (SABR) using flattening filter-free (FFF) beams. A total of 10 patients with lung cancer who were treated with SABR were evaluated. All treatment plans were created using an Acuros XB (AXB) of an Eclipse treatment planning system. An additional plans for comparison of different alagorithm recalcuated with anisotropic analytic algorithm (AAA) algorithm. To address both algorithms, the cumulative dose-volume histogram (DVH) was analyzed for the planning target volume (PTV) and organs at risk (OARs). Technical parameters, such as the computation times and total monitor units (MUs), were also evaluated. A comparison analysis of DVHs from these plans revealed the PTV for AXB estimated a higher maximum dose (5.2%) and lower minimum dose (4.2%) than that of the AAA. The highest dose difference observed 7.06% for the PTV $V_{105%}$. The maximum dose to the lung was also slightly larger in the AXB plans. The percentate volumes of the ipsilateral lung ($V_5$, $V_{10}$, $V_{20}$) receiving 5, 10, and 20 Gy were also larger in AXB plans than for AAA plans. However, these parameters were comparable between both AAA and AXB plans for the contralateral lung. The differences of the maximum dose for the spinal cord and heart were also small. The computation time of AXB plans was 13.7% shorter than that of AAA plans. The average MUs were 3.47% larger for AXB plans than for AAA plans. The results of this study suggest that AXB algorithm can provide advantages such as accurate dose calculations and reduced computation time in lung SABR plan using FFF beams, especially for volumetric modulated arc therapy technique.

Estimation of Secondary Scattered Dose from Intensity-modulated Radiotherapy for Liver Cancer Cases (간암환자에 대한 세기조절방사선치료에서의 2차 산란선량평가)

  • Kim, Dong Wook;Sung, Jiwon;Lee, Hyunho;Yoon, Myonggeun;Chung, Weon Kuu;Bae, Sun Hyun;Shin, Dong Oh;Chung, Kwangzoo;Lim, Young Kyung;Shin, Donho;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.295-302
    • /
    • 2013
  • We estimated secondary scattered and leakage doses for intensity-modulated radiotherapy (IMRT), volumetric arc therapy (VMAT) and tomotherapy (TOMO) in patients with liver cancer. Five liver patients were planned by IMRT, VMAT and TOMO. Secondary scatter (and leakage) dose and organ equivalent doses (OEDs) are measured and estimated at various points 20 to 80 cm from the iso-center by using radiophotoluminescence glass dosimeter (RPLGD). The secondary dose per Gy from IMRT, VMAT and TOMO for liver cancer, measured 20 to 80 cm from the iso-center, are 0.01~3.13, 0.03~2.34 and 0.04~1.29 cGy, respectively. The mean values of relative OED of secondary dose of VMAT and TOMO for five patients, which is normalized by IMRT, measured as 75.24% and 50.92% for thyroid, 75.14% and 40.61% for bowel, 72.30% and 47.77% for rectum, 76.21% and 49.93% for prostate. The secondary dose and OED from TOMO is relatively low to those from IMRT and VMAT. OED based estimation suggests that the secondary cancer risk from TOMO is less than or comparable to the risks from conventional IMRT and VMAT.

Quantitative Evaluation of the Corticospinal Tract Segmented by Using Co-registered Functional MRI and Diffusion Tensor Tractography (정상인에서 기능적 뇌 자기공명영상과 확산텐서영상 합성기법을 이용한 피질척수로의 위치에 따른 정량적 분석)

  • Jang, Sung-Ho;Hong, Ji-Heon;Byun, Woo-Mok;Hwang, Chang-Ho;Yang, Dong-Seok
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2009
  • Purpose : The purpose of this study was to investigate the quantitative evaluation of the corticospinal tract (CST) at the multiple levels by using functional MRI (fMRI) co-registered to diffusion tensor tractography (DTT). Materials and Methods : Ten normal subjects without any history of neurological disorder participated in this study. fMRI was performed at 1.5 T MR scanner using hand grasp-release movement paradigm. DTT was performed by using DtiStudio on the basis of fiber assignment continuous tracking algorithm (FACT). The seed region of interest (ROI) was drawn in the area of maximum fMRI activation during the motor task of hand grasp-release movement on a 2-D fractional anisotropy (FA) color map, and the target ROI was drawn in the cortiocospinal portion of anterior lower pons. We have drawn five ROIs for the measurement of FA and apparent diffusion coefficient (ADC) along the corona radiata (CR) down to the medulla. Results : The contralateral primary sensorimotor cortex (SM1) was mainly found to be activated in all subjects. DTT showed that tracts originated from SM1 and ran to the medulla along the known pathway of the CST. In all subjects, FA values of the CST were higher at the level of the midbrain and posterior limb of internal capsule (PLIC) than the level of others. Conclusion : Our study showed that co-registered fMRI and DTT has elucidated the state of CST on 3-D and analyzed the quantitative values of FA and ADC at the multiple levels. We conclude that co-registered fMRI and DTT may be applied as a useful tool for clarifying and investigating the state of CST in the patients with brain injury.

  • PDF

2-D/3-D Seismic Data Acquisition and Quality Control for Gas Hydrate Exploration in the Ulleung Basin (울릉분지 가스하이드레이트 2/3차원 탄성파 탐사자료 취득 및 품질관리)

  • Koo, Nam-Hyung;Kim, Won-Sik;Kim, Byoung-Yeop;Cheong, Snons;Kim, Young-Jun;Yoo, Dong-Geun;Lee, Ho-Young;Park, Keun-Pil
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.2
    • /
    • pp.127-136
    • /
    • 2008
  • To identify the potential area of gas hydrate in the Ulleung Basin, 2-D and 3-D seismic surveys using R/V Tamhae II were conducted in 2005 and 2006. Seismic survey equipment consisted of navigation system, recording system, streamer cable and air-gun source. For reliable velocity analysis in a deep sea area where water depths are mostly greater than 1,000 m and the target depth is up to about 500 msec interval below the seafloor, 3-km-long streamer and 1,035 $in^3$ tuned air-gun array were used. During the survey, a suite of quality control operations including source signature analysis, 2-D brute stack, RMS noise analysis and FK analysis were performed. The source signature was calculated to verify its conformity to quality specification and the gun dropout test was carried out to examine signature changes due to a single air gun's failure. From the online quality analysis, we could conclude that the overall data quality was very good even though some seismic data were affected by swell noise, parity error, spike noise and current rip noise. Especially, by checking the result of data quality enhancement using FK filtering and missing trace restoration technique for the 3-D seismic data inevitably contaminated with current rip noises, the acquired data were accepted and the field survey could be conducted continuously. Even in survey areas where the acquired data would be unsuitable for quality specification, the marine seismic survey efficiency could be improved by showing the possibility of noise suppression through onboard data processing.

The Relationship Between Family Related Variables and Program in Healthy Family Support Business (가족관련 변인과 건강가족지원사업 프로그램의 관계)

  • Lee, Hyoung-Ha
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.1
    • /
    • pp.167-175
    • /
    • 2013
  • This study set out from the perception that one should develop and activate differentiated programs from those 5 programs of the Health Family Support Center (family counseling program, family education support project, family affinity culture support project, care support project, diversity family support project) on the subjects (n=299) of residents in G metropolitan city by reflecting the levels of family values, communication between family members and family relationship. To achieve the study purposes above, this study devised research questions as follows: Research question 1. What are the levels of local residents for their family values, communication between family members and family relationship? Research question 2. Is there any difference in demanding family support project programs according to the local residents' family values, communication between family members and family relationship? Following are the results of this study: First, the levels were analyzed to be more than the average (on a maximum scale of 5 points) with local residents' family values (M=3.55, S.D.=.664), communication between family members (M=3.65, S.D.=.669), family relationship (M=3.69 S.D=.584) Second, the necessity levels for family values, communication between family members and family relationship of the group below the average as compared with the group over the average was found to be significantly high in family education support project, family affinity culture support project, care support project and diversity family support project except family counseling program. Accordingly, strategic plans for increasing the participation rate for the programs by the Health Family Support Center and activating those programs could be by investigating in advance the levels of family values, communication between family members and family relationship by each program respectively and differentiating the target level for the program by the group, or by giving preference to the group below the average who have high needs of program necessity when making decisions for the participation preference of the programs.

Effect of Aqueous Phase Composition on the Stability of a Silica-stabilized Water-in-oil Emulsion (유화제로서 실리카를 이용한 유중수형 에멀젼의 안정성에 미치는 수상부 조성의 영향)

  • Kim Jin-Hwang;Kim Song-I;Kyong Kee-Yeol;Lee Eun-Joo;Yoon Moung-Seok
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.3 s.47
    • /
    • pp.353-359
    • /
    • 2004
  • The extent of silica flocculation can be modified by varying the silica concentration, aqueous phase pH, salt and polvmer concentration. High volume fraction W/O emulsion stabilized by hydrophobic silica was established with various aqueous phase conditions for cosmetic application. By increasing the silica concentration up to $1.0\;wt\%,$ the size of droplet decreased. A high silica concentration increased the viscosity of continuous oil phase by network formation, which resulted in target size of droplet. The stability of W/O emulsion is improved as increasing the aqueous phase pH. At low and intermediate pH, the emulsions became more stable by adding salt $(0.083\;mol\;dm^{-3}\;MgSO_4).$ At high PH, the presence of salt caused significant destabilization. The gelation behavior of the emulsion indicates that the effect of salt on silica-stabilized emulsion is derived from an electrostatic attraction. The addition of xanthan gum in aqueous phase increased the mono-dispersity of the W/O emulsion by making water more hydrophobic and hindering the recombination of droplets. In conclusion, these results indicate that very stable emulsifier-free, finely dispersed W/O emulsion can be achieved for cosmetic application by changing the aqueous phase composition.

Planting Plan of Ecological Corridor at Destroyed Mountain Area as a Result of Road Construction (도로개발에 의하여 훼손된 산림지역 생물이동통로 식재계획)

  • 이경재;한봉호
    • Korean Journal of Environment and Ecology
    • /
    • v.16 no.3
    • /
    • pp.321-337
    • /
    • 2002
  • This study was carried out to draw up the planting plan of bridge type ecological corridor for animals migration at Hakgogae(ridge) destroyed by road construction in Yongin, Gyeonggi-do, South Korea. It was conducted with two steps, survey and planting master plan. We surveyed the structure of topography, plant community, and animal habitat. We also selected the target species migrate ecological corridor and suggested a concept of each planting area, the planting species, and the planting density based on the analyzed data and finally drew up the planting plan. The structure of topography was a steep slope due to the mountain ridge destruction so the bridge type ecological corridor was could be applied in this study and we supposed that the animals migrate along the both edge of corridor. As the results of analyzed plant community structure in two sides, the dominant woody species, Quercus serrata and Q. variabilis were distributed on the bottom and the belly of a mountain, while Pinus densiflora community was distributed on the mountain ridge as edaphic climax. The similarity between Q. serrata -Q. mongolica -Q. variabilis community on the West of survey site and Q. serrata -Q. mongolica community on the East of survey site was high in 71.0 percentages. As the results of surveying birds and some mammalia, seven species and fifty-seven individuals of birds were founded in survey area, and two species and two individuals of rodents were founded. We selected birds and some mammals for the migration species that supposed to migrate ecological corridor in drawing up the planting plan. And then we divided the planting areas into bird corridor and habitat, and mammals corridor, also suggested the planting areas in detail as follows: community planting area of shrub at slope adjacent to the bridge exit as a buffer zone, screen planting area, community planting area of herb at steep slope connected with mountain areas, inducement planting area of the animals, community planting area for bird migration, community planting area for mammals migration, and community planting area for bird habitat. We selected the planting woody species which were the constancy ratio based on the analyzed data of plant community around mountain areas was high, and suggested the planting master plan each space.