• Title/Summary/Keyword: TaqMan assay

Search Result 57, Processing Time 0.026 seconds

Rapid detection and quantification of porcine circovirus type 2 (PCV 2) DNA in Real-time PCR (Real-time PCR을 이용한 돼지써코바이러스 감염증 진단법 연구)

  • Kim, Eun-Gyeong;Hwang, Bo-Won;Lee, Jong-Min;Son, Byeong-Guk;Park, Ho-Jung;Kim, Tho-Kyoung
    • Korean Journal of Veterinary Service
    • /
    • v.32 no.4
    • /
    • pp.299-306
    • /
    • 2009
  • Assay for the detection and quantification of porcine circovirus type 2 (PCV 2) with the real-time PCR were developed. TaqMan probe real-time using a set of primer/probe was developed for detection of PCV 2. In this study we applied real-time PCR assay to 320 samples, collected from pig farms. In 151 of 320 samples, PCV 2 DNA was detected by conventional PCR assay. All samples positive for PCV 2 DNA in conventional PCR assay were also positive in Real-time PCR assay, but 69 of 169 samples that tested negative for PCV 2 DNA in conventional assay were tested positive in TaqMan probe real-time PCR assay. The test of TaqMan probe real-time PCR resulted in detection and quantification limits of 101 copies per sample. TaqMan probe real-time PCR assay increased the number of samples in which PCV 2 was detected by 21%. TaqMan probe real-time PCR assay is very efficient method in contrast to the conventinal PCR, becoming increasingly important method for gene analysis.

Rapid Identification of Vibrio vulnificus in Seawater by Real-Time Quantitative TaqMan PCR

  • Wang, Hye-Young;Lee, Geon-Hyoung
    • Journal of Microbiology
    • /
    • v.41 no.4
    • /
    • pp.320-326
    • /
    • 2003
  • In order to identify Vibrio vulnificus in the Yellow Sea near Gunsan, Korea during the early and late summers, the efficiency of the real-time quantitative TaqMan PCR was compared to the efficiency of the conventional PCR and Biolog identification system^TM. Primers and a probe were designed from the hemolysin/cytolysin gene sequence of V. vulnificus strains. The number of positive detections by real-time quantitative TaqMan PCR, conventional PCR, and the Biolog identification system from seawater were 53 (36.8%), 36 (25%), and 10 strains (6.9%), respectively, among 144 samples collected from Yellow Sea near Gunsan, Korea. Thus, the detection method of the real-time quantitative TaqMan PCR assay was more effective in terms of accuracy than that of the conventional PCR and Biolog system. Therefore, our results showed that the real-time TaqMan probe and the primer set developed in this study can be applied successfully as a rapid screening tool for the detection of V. vulnificus.

TaqMan Probe Real-Time PCR for Quantitative Detection of Mycoplasma during Manufacture of Biologics (생물의약품 제조공정에서 마이코플라스마 정량 검출을 위한 TaqMan Probe Real-Time PCR)

  • Lee, Jae Il;Kim, In Seop
    • KSBB Journal
    • /
    • v.29 no.5
    • /
    • pp.361-371
    • /
    • 2014
  • Mycoplasma is well recognized as one of the most prevalent and serious microbial contaminants of biologic manufacturing processes. Conventional methods for mycoplasma testing, direct culture method and indirect indicator cell culture method, are lengthy, costly and less sensitive to noncultivable species. In this report, we describe a new TaqMan probe-based real-time PCR method for rapid and quantitative detection of mycoplasma contamination during manufacture of biologics. Universal mycoplasma primers were used for mycoplasma PCR and mycoplasma DNA was quantified by use of a specific TaqMan probe. Specificity, sensitivity, and robustness of the real-time PCR method was validated according to the European Pharmacopoeia. The validation results met required criteria to justify its use as a replacement for the culture method. The established real-time PCR assay was successfully applied to the detection of mycoplasma from human keratinocyte and mesenchymal stem cell as well as Vero cell lines artificially infected with mycoplasma. The overall results indicated that this rapid, specific, sensitive, and robust assay can be reliably used for quantitative detection of mycoplasma contamination during manufacture of biologics.

Multiplex TaqMan qPCR Assay for Detection, Identification, and Quantification of Three Sclerotinia Species

  • Dong Jae Lee;Jin A Lee;Dae-Han Chae;Hwi-Seo Jang;Young-Joon Choi;Dalsoo Kim
    • Mycobiology
    • /
    • v.50 no.5
    • /
    • pp.382-388
    • /
    • 2022
  • White mold (or Sclerotinia stem rot), caused by Sclerotinia species, is a major air, soil, or seed-transmitted disease affecting numerous crops and wild plants. Microscopic or culture-based methods currently available for their detection and identification are time-consuming, laborious, and often erroneous. Therefore, we developed a multiplex quantitative PCR (qPCR) assay for the discrimination, detection, and quantification of DNA collected from each of the three economically relevant Sclerotinia species, namely, S. sclerotiorum, S. minor, and S. nivalis. TaqMan primer/probe combinations specific for each Sclerotinia species were designed based on the gene sequences encoding aspartyl protease. High specificity and sensitivity of each probe were confirmed for sclerotium and soil samples, as well as pure cultures, using simplex and multiplex qPCRs. This multiplex assay could be helpful in detecting and quantifying specific species of Sclerotinia, and therefore, may be valuable for disease diagnosis, forecasting, and management.

Detection of infectious canine hepatitis virus by TaqMan real-time PCR method (TaqMan 실시간 PCR법에 의한 개 전염성 간염 바이러스의 검출)

  • Wang, Hye-young;Choi, Jae-yong;Lee, Mi-jin;Park, Jin-ho;Cho, Mae-Rim;Han, Jae-cheol;Choi, Kyoung-seong;Chae, Joon-seok
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.4
    • /
    • pp.655-662
    • /
    • 2004
  • The aim of this work was the validation of a rapid real-time PCR assay based on TaqMan technology for the unequivocal identification of infectious canine hepatitis (ICH) virus, to be used directly on DNA purified from blood specimens. A real-time PCR system targeting at the E3 ORFA gene sequence of canine adenovirus type 1 was optimized and validated through comparative analysis of samples using conventional PCR system. The real-time PCR assay based on TaqMan technology could disclose 23 (37.7%) out of 61 samples as PCR positive. In contrast, 18 (29.5%) samples were found PCR positive when conventional PCR was applied on these samples. The use of the ABI Prism 7700 sequence detection system allowed the efficient determination of the amplified product accumulation through a fluorogenic probe. The entire real-time TaqMan PCR assay, including DNA extraction, amplification, and detection could be completed within 3 hours. The detection method of real-time TaqMan PCR assay was 1,000 times more sensitive than conventional PCR. Real-time TaqMan probe and primer set developed and optimized in this study is a sensitive, rapid and accurate method for detection of ICH virus and can be effective screening tool for the detection of ICH in a diagnostic laboratory routines.

Development of Real-time Quantitative PCR Assay based on SYBR Green I and TaqMan Probe for Detection of Apple Viruses (사과 바이러스 검정을 위한 SYBR Green I 및 TaqMan probe 기반의 real-time PCR 검사법 개발)

  • Heo, Seong;Chung, Yong Suk
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.65 no.4
    • /
    • pp.496-507
    • /
    • 2020
  • Virus infections of apples result in lowered commercial qualities such as low sugar content, weakened tree vigor, and malformed fruits. An effective way to control viruses is to produce virus-free plants based on the development of an accurate and sensitive diagnostic method. In this study, real-time PCR assays based on SYBR Green I and TaqMan probes were developed for detecting ASGV, ASPV, and ApMV viruses. These methods can detect and quantify 103 to 1011 RNA copies/μL of each virus separately. Compared with methods with two different dyes, the SYBR Green I-based method was efficient for virus detection as well as for assay using the TaqMan probe. Field tests demonstrated that real-time PCR methods developed in this study were applicable to high-throughput diagnoses for virus research and plant quarantine.

Evaluation of a novel TaqMan probe-based real-time polymerase chain reaction (PCR) assay for detection and quantitation of red sea bream iridovirus

  • Kim, Guk Hyun;Kim, Min Jae;Choi, Hee Ju;Koo, Min Ji;Kim, Min Jeong;Min, Joon Gyu;Kim, Kwang Il
    • Fisheries and Aquatic Sciences
    • /
    • v.24 no.11
    • /
    • pp.351-359
    • /
    • 2021
  • The red sea bream iridovirus (RSIV) belonging to genus Megalocytivirus is responsible for red sea bream iridoviral disease (RSIVD) in marine and freshwater fishes. Although several diagnostic assays for RSIV have been developed, diagnostic sensitivity (DSe) and specificity (DSp) of real-time polymerase chain reaction (PCR) assays are not yet evaluated. In this study, we developed a TaqMan probe-based real-time PCR method and evaluated its DSe and DSp. To detect RSIV, the probe and primers were designed based on consensus sequences of the major capsid protein (MCP) genes from megalocytiviruses including RSIV, infectious spleen and kidney necrosis virus (ISKNV), and turbot reddish body iridovirus (TRBIV). The probe and primers were shown to be specific for RSIV, ISKNV, and TRBIV-types megalocytiviruses. A 95% limit of detection (LOD95%) was determined to be 5.3 viral genome copies/µL of plasmid DNA containing the MCP gene from RSIV. The DSe and DSp of the developed real-time PCR assay for field samples (n = 112) were compared with those of conventional PCR assays and found to be 100% and 95.2%, respectively. The quantitative results for SYBR Green and TaqMan probe-based real-time PCR were not significantly different. The TaqMan probe-based real-time PCR assay for RSIV may be used as an appropriate diagnostic tool for qualitative and quantitative analysis.

Development of TaqMan Quantitative PCR Assays for Duplex Detection of Dirofilaria immitis COI and Dog GAPDH from Infected Dog Blood (심장사상충에 감염된 개 혈액에서 Dirofilaria immitis의 COI와 개의 GAPDH를 이중 검출하기 위한 정량적 TaqMan PCR 분석법의 개발)

  • Oh, In Young;Kim, Kyung Tae;Gwon, Sun-Yeong;Sung, Ho Joong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.1
    • /
    • pp.64-70
    • /
    • 2019
  • Dirofilaria immitis (D. immitis) is a filarial nematode that causes cardiopulmonary dirofilariasis in dogs. In the late stages of infection, infected dogs show one or more symptoms and advanced heart disorder with perivascular inflammation. To detect D. immitis specifically and efficiently in the early stages of infection, a duplex TaqMan qPCR assay was developed based on previous studies using primers and probes specialized to detect D. immitis cytochrome c oxidase subunit I (COI) and dog glyceraldehyde-3-phosphate dehydrogenase (GAPDH). As positive controls, plasmid DNAs were constructed from D. immitis COI or dog GAPDH and a TA-cloning vector. Simplex and duplex TaqMan qPCR assays were performed using the specific primers, probes, and genomic or plasmid DNA. The duplex reaction developed could detect D. immitis COI and dog GAPDH in the same sample simultaneously after optimization of the primer concentrations. The limit of detection was 25 copies for the simplex and duplex assays, and both showed good linearity, high sensitivity, and excellent PCR efficiency. The duplex assays for pathogen detection reduce the costs, labor, and time compared to simplex reactions. Therefore, the duplex TaqMan qPCR assay developed herein will allow efficient D. immitis detection and quantification from a large number of samples simultaneously.

Rapid Detection of Enterobacter sakazakii Using TaqMan Real-Time PCR Assay

  • Kang, Eun-Sil;Nam, Yong-Suk;Hong, Kwang-Won
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.516-519
    • /
    • 2007
  • Enterobacter sakazakii is an emerging food pathogen, which induces severe meningitis and sepsis in neonates and infants, with a high fatality rate. The disease is generally associated with the ingestion of contaminated infant formula. In this study, we describe the development of a real-time PCR protocol to identify E. sakazakii using a TaqMan probe, predicated on the nucleotide sequence data of the 168 rRNA gene obtained from a variety of pathogens. To detect E. sakazakii, four primer sets and one probe were designed. Five strains of E. sakazakii and 28 non-E. sakazakii bacterial strains were used in order to ensure the accuracy of detection. The PCR protocol successfully identified all of the E. sakazakii strains, whereas the 28 non-E. sakazakii strains were not detected by this method. The detection limits of this method for E. sakazakii cells and purified genomic DNA were 2.3 CFU/ assay and 100 fg/assay, respectively. These findings suggest that our newly developed TaqMan real-time PCR method should prove to be a rapid, sensitive, and quantitative method for the detection of E. sakazakii.

Lack of Association between Chlamydia trachomatis Infection and Cervical Cancer - Taq Man Realtime PCR Assay Findings

  • Farivar, Taghi Naserpour;Johari, Pouran
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.3701-3704
    • /
    • 2012
  • Background: Cervical cancer is one of the most common cancers in developing countries and the second most common type of cancer in women globally. Several recent studies suggested a co factor role for Chlamydia trachomatis in pathogenesis of cervical cancer. This study aimed to evaluate existence of C. trachomatis DNA in pathologic blocks of patients with cervical cancer. Materials and methods: Seventy-six formaldehyde fixed paraffin embedded tissue specimens from patients with histologically proven history of cervical cancer as well as 150 blocks from healthy peoples were included in the present study. Thin slices were prepared from selected blocks followed by deparaffinization and DNA extraction; the presence of C. trachomatis DNA was examined by Taq Man real-time PCR. Results: Our TaqMan real time PCR assay with cervical specimens of patients with cervical cancer showed that there was no C. trachomatis DNA. Also, we found three positive specimens among our control group. Conclusion: It seems that based on results obtained from the specimens examined in the present study, there is no association between the presence of C. trachomatis DNA in cervical specimens and cervical cancer.