• Title/Summary/Keyword: Tapping

Search Result 353, Processing Time 0.023 seconds

Development of a Product Oriented Group for Mathematics Teachers Professional Growth

  • Liu, Chun-Yi;Cheo, Shu-Tin
    • Research in Mathematical Education
    • /
    • v.15 no.4
    • /
    • pp.341-355
    • /
    • 2011
  • A research group consisting of some mathematics education scholars and school teachers has been formed to build a website which intended to combine both theories and practices of mathematical teaching since 2002. There were three working stages: video-tapping realistic math teaching, developing video discs of different themes, and designing e-Learning. The group members learned knowledge of teaching by actual participating. On the other hand, the products enabled the audience to get professional development in knowledge of both mathematics and teaching. Management process of this group and effects upon the participants and users will be presented and discussed in this paper. A research group consisting of some mathematics education scholars and school teachers has been formed to build a website which intended to combine both theories and practices of mathematical teaching since 2002. There were three working stages: video-tapping realistic math teaching, developing video discs of different themes, and designing e-Learning. The group members learned knowledge of teaching by actual participating. On the other hand, the products enabled the audience to get professional development in knowledge of both mathematics and teaching. Management process of this group and effects upon the participants and users will be presented and discussed in this paper.

Stability measurements on the implants of mandibular molar area using OsstellTM (OsstellTM을 이용한 하악구치부 임플랜트의 안정성 측정)

  • Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.3
    • /
    • pp.205-211
    • /
    • 2001
  • The aim of this investigation was to evaluate successfully functioning implants stability in the partially edentulous mandibular molar sites by resonance frequency measurements. Resonance frequency measurement is more objective and clinically non-invasive method than any other methods had been used. In this study, $Osstell^{TM}$ (Integration Diagnostics, Sweden) was used. 15 patients ( 7 males, 8 females ) were received each 2 implants in their mandibular unilaterally partial edentulous molar sites. Total 30 implants were installed, 28 implants were $Br{\aa}nemark^{(R)}$ self-tapping fixtures(MK II, Nobel Biocare, Sweden) and 2 were $3i^{(R)}$(USA) self-tapping fixtures. Minimum of functional loading durations was 12 months and there were no significant marginal bone resorptions and peri-implant problems. From this test, the following results were drawn: 1. Mean ISQ values of implants in the first and second mandibular molar area were $73.66{\pm}4.45$, $71.93{\pm}3.41$, respectively. There was no significant difference between two groups(p>0.05). Also mean ISQ value of total sum was 72.8. 2. Mean ISQ values of implants in males and females group were $71.64{\pm}4.06$, $73.81{\pm}3.76$, respectively. And there was no significant difference between two group(p>0.05). 3. Correlation between implant lengths and ISQ values was weak(r=0.128).

  • PDF

Investigation of receiving position in the measurement method for floor impact sound in a testing building (표준시험동 바닥충격음 측정위치에 대한 고찰)

  • Lee, Sin-Young;Yoo, Seung-Yup;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.964-968
    • /
    • 2007
  • The measurement of floor impact sound have been standardized in KS 2810-1 and 2. The height of receiving microphones position is specified in the standard as 1.2m which is almost half height of apartment rooms as a listening position. In this study, receiving positions are investigated by measuring the distribution of sound pressure levels at 792 receiving microphone positions in the standard testing building. Standard impact sources, tapping machine and impact ball, are driven on the center position in the source room where is located at the above floor. It was found that the distribution of sound pressure levels in the receiving room indicates significant deviation at different frequencies there is more than 5dB drop at 63Hz but 2dB rise at 125Hz at a height of 1.2m when the impact ball is driven, in the other case of a generating tapping machine there is more than 2dB rise at 125Hz at a height of 1.2m due to room modes.

  • PDF

Host Finding, Mating Behavior and Their Reproduction Model of Anagrus incarnatus Haliday (Anagrus incarnatus Haliday의 기주선택 및 교미행동과 이의 생식방법에 관한 연구)

  • 장영덕;여윤수;김용헌
    • Korean journal of applied entomology
    • /
    • v.30 no.2
    • /
    • pp.101-105
    • /
    • 1991
  • The host finding, ovipostition of Anagrus incarnafus Haliday and the sex ratio of its offsprings was determined. Both male and female mate immediately after emergence and the female parasitoid search for host eggs by drumming with antenna immediately after release on the rice seedings. Time required for the host searching, drumming with antenna, tapping and inserting with ovipositor, and ovipositing of A. incarnaws takes 188.5, 17.5, 72.4 and 206.7 seconds, respectively. The time required for mating takes 16-21 seconds. The sex ratio of offsprings between female and male was about 3: 1 in mated females and all the offsprings emerged from the eggs of unmated females were males. So, A. incarnafus can reproduce zygogenetically and parthenogenetically and the mode of parthenogenetic reproduction was an arrhenotokous parasitoid.

  • PDF

An Optical Threshold Generator for the Stream Cipher Systems (스트림 암호 시스템을 위한 광 Threshold 발생기)

  • 한종욱;강창구;김대호;김은수
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.11
    • /
    • pp.90-100
    • /
    • 1997
  • In this paper, we propose a new optical thresold generator as a key-stream genrator for stream cipher systems. The random key-bit stream is generated by a digital generator that is composed of LFSRs and nonlinear ligics. Digital implementatin of a key-stream generator requires large memory to implement programmable tapping points. This memory problem may be overcome easily by using the proposed optical system which has the proberty of 2D parallel processing.To implement hte threshold generator optically, we use conventional twisted nematic type SLMs (LCDs). This proposed system is based on the shadow casting technique for the AND operation between taps and sregister stages. It is also based on the proposed PMRS method for modulo 2 addition. The proposed PMRS method uses the property of light's polarization on LCD and can be implemented optically using one LCD and some mirrors. One of the major advantages of the proosed system is that there is no limitation of the number of the progarmmable tapping points. Therefore, the proposed system can be applied for the 2D encryption system which processes large amounts of data such as 2D images. We verify the proposed system with some simulation.

  • PDF

A Study About Tool Wear Characteristic on Geometry of Tap (탭 형상에 따른 공구마모 특성에 관한 연구)

  • 최만성;윤홍기
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.892-897
    • /
    • 2000
  • In this study, tap wear was analyzed not only to predict the tap life time but also to propose an improved tap design. Because rake angle and thread relief of tap are the significant factors in geometry of tap, these two factors were picked as the experiment variables. The experiment was conducted with six types of tap which have 6$^{\circ}$ , 8$^{\circ}$ and 12$^{\circ}$ of rake angles with 0,08mm and 0.14 mm of thread relief. From the measured cutting force, it could be known that cutting torque was low at the large the rake thread relief and tool life was long as rake angle became large. Eventually, tool life is longest when rake angle is 12$^{\circ}$ and the with 0.08mm thread relief. Aand the width of crater wear and that of flank wear were measured when a tapping torque was 20 [$kg_f$-mm] . Most of the measured values were above the width of tool wear[$V_B$=O.O3m], which means that tool life is over.

  • PDF

Development of Split Tees for Gas Steel Pipelines (강재 가스배관용 분기티의 개발 연구)

  • Kim Young Gyu;Noh Ou Sun;Kim Ji Yoon
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.4 s.12
    • /
    • pp.6-12
    • /
    • 2000
  • We have developed a new split tee which can be used to effectively branch into a main gas steel pipelines without losing any gas pressure or having to shut down a line. The split tee has been designed considering the locations of branch connection to the pipelines. Therefore, we could keep the depth of buried pipelines which used to be the problem of the conventional split tees. Test results of the developed split tee showed that the performance of the tightness, hydraulic strength, sealing, welding, bending, and compatibility were excellent. The application of the split tee can provide the advantage of eliminating cost and time, and easy field pipeline coatings.

  • PDF

Performance Evaluation Method of a Swing Check Valve (스윙형 역지밸브 성능 평가 방법)

  • Kim, Y.S.;Lee, D.W.;Kim, D.W.;Park, S.K.;Hong, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.881-886
    • /
    • 2003
  • In spite of its simple design, structure and operating mechanism, swing check valves are one of the critical components which adversely affect the safety of the nuclear power plants if they fail to function properly. Therefore, it is important to evaluate the performance condition of the swing check valves in safety-related systems. The performance characteristics of swing check valves include opening characteristics, the minimum required flow velocity, the pressure drop at design flow, the disc stability, and the effect of the upstream disturbances. Among factors to identify the performance of a swing check valve, a method to evaluate the opening characteristics and the minimum required flow velocity, which guarantees to fully open the disc and hold the disc without motion, are presented to determine the operating region of the swing check valve, such as stable, tapping, or oscillation. Based on the determined operating region and opening characteristics, the simple methods of wear and fatigue analyses of the specific parts of the valve are also described.

  • PDF

Difference of total activation depends on stimulation paradigm at motor and visual cortices and cerebellum (운동과 시각 피질, 소뇌에서 자극변화에 따른 총활성화의 차이)

  • Chung, S.C.;Song, I.C.;Chang, K.H.;Yu, B.K.;Mun, C.W.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.289-290
    • /
    • 1998
  • Purpose To investigate the difference of total activation in visual area, motor area, and cerebellum according to the stimulation paradigm. Materials and Methods Functional MR imaging was performed in 5 healthy volunteers with visual and motor activity using EPI technique. LED and Checker-Board stimulation were performed for visual activity. Thumb motion and Finger tapping were performed for motor and cerebellum activity. Time course data was obtained by calculating the total activation which was defined as the number of activated pixels x averaged pixel intensity. Results In the case of visual activity with LED stimulation, we found increased total activity of more than 100% compared with Checker-Board stimulation. In the case of motor area and cerebellum with Finger tapping stimulation, we found increased total activity of more than 100% and 150%, respectively compared with Thumb motion stimulation.

  • PDF