• Title/Summary/Keyword: Tapping

Search Result 353, Processing Time 0.032 seconds

Vibration Analysis of the Tapping AFM Microcantilevers Using Proper Orthogonal Decomposition (적합직교분해법을 이용한 AFM 마이크로캔틸레버의 진동해석)

  • Hong, Sang-Hyuk;Lee, Soo-Il
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.4
    • /
    • pp.414-421
    • /
    • 2010
  • The proper orthogonal decomposition(POD) is used to the vibration analysis of microcantilever in tapping mode atomic force microscopy(AFM). The proper orthogonal modes (POM) are extracted from vibrating signals of microcantilever when it resonates and taps the sample. We present recent ideas based on POD and detailed experiments that yield new perspectives into the microscale structures such as the tapping cantilever. The linearized modeling technique based on POD is very useful to show the principal characteristics of the complex dynamic responses of the AFM microcantilever.

Nonlinear Dynamics at the Nanoscale (나노스케일에서의 비선형 동역학)

  • Lee, Soo-Il;Hong, Sang-Hyuk;Park, Jun-Hyung;Lee, Jang-Moo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.125-128
    • /
    • 2004
  • AFM(Atomic Force Microscope) becomes a versatile tool in the nanoscale measurements and processes. Especially the tapping mode is a very useful mode in AFM operation to measure and process at the nanoscale. Although the tapping mode has a great potential for the novel techniques such as phase imaging, however, it is not clearly known the fundamental mechanics affected by complex tip-sample interactions. This paper shows the various nonlinear dynamic features in tapping mode AFM microcantilevers including hysteretic jumps and period doublings of the microcantilevers. Also it is discussed the complex dynamics of CNT(Carbon Nanotube) probes and the opportunities on the nanoscale nonlinear dynamics.

  • PDF

Functional Stroke Methods of Korean Keyboards Using Special Feature of Korean Vowels (한글 모음의 특성을 고려한 자판의 기능성 입력 방법)

  • Kim, Kuk
    • Journal of the Ergonomics Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.167-169
    • /
    • 2009
  • Korean vowels have special feature such that same vowels do not appear sequentially in a syllable. And two vowels appear with consistent rules. Using this feature, functional key stroke methods are available to Korean computer keyboard. Tapping a key makes diphthong easily. This will be used to Korean computer keyboard design.

Fitts' Law for Angular Foot Movement in the Foot Tapping Task

  • Park, Jae-Eun;Myung, Ro-Hae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.5
    • /
    • pp.647-655
    • /
    • 2012
  • Objective: The purpose of this study was to confirm difference between angular foot movement time and existing foot Fitts' law predicting times, and to develop the angular foot Fitts' law in the foot tapping task. Background: Existing studies of foot Fitts' law focused on horizontal movement to predict the movement time. However, when driving a car, humans move their foot from the accelerator to the brake with a fixed heel. Therefore, we examined the experiment to measure angular foot movement time in reciprocal foot tapping task and compared to conventional foot Fitts' law predicting time. And, we developed the angular foot Fitts' law. Method: In this study, we compared the angular foot movement time in foot tapping task and the predicted time of four conventional linear foot Fitts' law models - Drury's foot Fitts' law, Drury's ballistic, Hoffmann's ballistic, Hoffmann's visually-controlled. 11 subjects participated in this experiment to get a movement time and three target degrees of 20, 40, and 60 were used. And, conventional models were calculated for the prediction time. To analyze the movement time, linear and arc distance between targets were used for variables of model. Finally, the angular foot Fitts' law was developed from experimental data. Results: The average movement times for each experiment were 412.2ms, 474.9ms, and 526.6ms for the 89mm, 172mm, and 253mm linear distance conditions. The results also showed significant differences in performance time between different angle level. However, all of conventional linear foot Fitts' laws ranged 135.6ms to 401.2ms. On the other hand, the angular foot Fitts' law predicted the angular movement time well. Conclusion: Conventional linear foot Fitts' laws were underestimated and have a limitation to predict the foot movement time in the real task related angular foot movement. Application: This study is useful when considering the human behavior of angular foot movement such as driving or foot input device.

Effects of Head Posture and Occlusal Splint on Swallowing Movement (두부자세 및 교합장치에 따른 연하운동의 변화)

  • Sung-Jin Moon;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.1
    • /
    • pp.55-65
    • /
    • 1996
  • This study was performed to investigate the effects of head posture and occlusal splint on the vertical dimension in mandibular rest position and swallowing. Thirty health dental students ware selected lot this study and BioEGNⓡ(Bioresearch Inc., USA) was used for measuring interocclusal distance during rest - swallowing - rest - tapping movement. This swallowing movements were observed in both normal head posture(NHP) and forward head posture (FHP). Thickness of occlusal splint was about 2mm at posterior molar area and even tooth contact were achieved on light biting. The four mandibular positions at which interocclusal distance measured were swallowing position, after swallowing position in which interocclusal distance was maximum, rest position follows swallowing, and tapping position after rest. Changes of distance in each position were measured for three mandibular planes, that is, sagittal, frontal, and horizontal plane, respectively. The results obtained were as follows : 1. In normal head posture, the mandible was raised 1.03mm without splint, and 0.77mm with splint on swallowing, and there was no significant difference between the two. In horizontal plane, however, mandible was displaced more anteriorly in both swallowing position and tapping position with splint. 2. In forward head posture, the mandible was less raised with splint on swallowing, but features in horizontal plane were almost same as those in normal head posture. 3. In natural dentition, significant difference between NHP and FHP were observed in horizontal plane trajectory for swallowing and tapping position. But the difference for same positions were observed in frontal trajectory with splint. 4. Total amount of mandibular movement of two groups classified with sagittal interocclusal distance of swallowing position generally showed significant difference between the higher and the lower height group in head posture without splint. 5. Correlationship among total amount of mandibular movement for three mandibular planes were observed between sagittal plane and horizontal plane, and between sagittal plane and frontal plane in head posture without splint.

  • PDF

Measurement and Comparison of Finger Tapping Movement in Patients with Idiopathic Parkinson's Disease and Normal Subjects using Gyrosensor (자이로센서를 이용한 특발성 파킨슨병 환자와 정상인의 손가락 벌렸다 오므리기 동작의 측정과 비교)

  • Kim, Ji-Won;Kwon, Yu-Ri;Lee, Jae-Ho;Eom, Gwang-Moon;Kwon, Do-Young;Koh, Seong-Beom;Park, Byung-Kyu;Hong, Jung-Hwa
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.3
    • /
    • pp.240-244
    • /
    • 2010
  • The purpose of this study is to compare finger tapping (FT) movement of patients with Parkinson's disease (PD) with normal subjects. A gyrosensor system was used for the measurement of FT movement, because it provides angular velocity free from the gravitational artifact and it can be used during clinical FT test listed in unified PD rating scale (UPDRS). Forty PD patients (age: 65.7 ${\pm}$ 11.1 yrs, H&Y stage:2.3 ${\pm}$ 0.5), 14 age-matched elderly subjects (65${\pm}$3.9 yrs) and 17 healthy young subjects (24${\pm}$2.1yrs) participated in this study. Angular velocity of finger tapping movement was measured in both right and left index finger. As quantitative measures, root-mean-squared (RMS) angular velocity, RMS angle, peak power and total power were used. ANOVA showed that all measures were significantly different among three groups (p<0.001) in all quantitative measures. Post-hoc test revealed that all quantitative measures except peak power in patients with PD were significantly smaller than in both healthy elderly and young subjects (p<0.01). This suggests that the measures developed in this study can distinguish patients with PD from normal subjects.

Analysis on sEMG Signals of Contents Using Finger Tapping Device (Finger Tapping 기기를 활용한 콘텐츠의 sEMG 신호 분석)

  • Han, Sang-bae;Byeon, Sang-kyu;Kim, Jae-hoon;Shin, Sung-Wook;Chung, Sung-taek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.153-160
    • /
    • 2019
  • In this paper, we would like to support anyone who can rehabilitate conveniently and happily by implementing rehabilitation device and game contents that can improve the motor ability of fingers. So we developed a Finger Tapping Device that can measure finger-regulation ability, accuracy, and agility and implemented tracking, visual response, finger-regulation on game contents by utilizing this device. The verification of usability was confirmed by analyzing sEMG signals during the execution of three types of game contents after attaching sEMG to the flexor digitorum poundus, which is most involved in finger movement. As a result of the experiment, activation of the flexor digitorum poundus was performed during execution of every game contents. Furthermore, we confirmed that there is a difference in agility by measuring the reaction time for each finger according to the visual response.

A Design of Encryption Method for Strong Security about Tapping/Interception of VoIP Media Information between Different Private Networks (이종 사설망간에 VoIP 미디어의 도.감청 보안 강화를 위한 암호화 기법 설계)

  • Oh, Hyung-Jun;Won, Yoo-Hun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.3
    • /
    • pp.113-120
    • /
    • 2012
  • VoIP provides voice data service using existing IP networks and has received much attention recently. VoIP service has a variety of security vulnerabilities. Types of main attacks on VoIP service are tapping/interception, DoS attacks, spam, misuse of service attacks and the like. Of these, confidential information leak because of tapping/interception has been considered as a critical problem. Encryption techniques, such as SRTP and ZRTP, are mostly used to prevent tap and intercept on VoIP media information. In general, VoIP service has two service scenarios. First, VoIP service operates within a single private network. Second, VoIP service operates between different private networks. Both SRTP and ZRTP for VoIP media information within a single private network can perform encryption. But they can not perform encryption between different private networks. In order to solve this problem, in this paper, we modify SRTP protocol. And then, we propose an encryption method that can perform encryption of VoIP media information between the different private networks.

OPTIMUM MANDIBULAR POSITION GUIDE BY USE OF EMG ACTIVITY AND INTRA-ORAL TRACER

  • Lee Seung-Ho;Kang Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.6
    • /
    • pp.560-571
    • /
    • 2002
  • Jaw relations and the recording methods have been controversial aspects of dentistry. The purpose of this study was to quantify the relative muscle activity of the masseter and temporal muscles in relation to different intermaxillary relations recorded by intra-oral tracer during maximal clenching and to decide the optimal mandibular position. Ten volunteers with healthy TMJ were studied. Intra-oral tracer was assembled and bite block was fabricated in the articulator. Intra-oral tracer was placed in the mouth, and four mandibular positions were recorded. EMG activity was recorded on a BIO-PAK system (Bio-Research Associates, Inc. USA.) in masseter and temporal muscle and compared in each mandibular positions. The results were as follows: 1. In comparison with maximum intercuspation, the chewing position was the most similar followed by tapping position, myocentric position and posterior border position. However the differences were not statistically significant. 2. In comparison of bilateral symmetry of masseter muscle, tapping position was the most symmetrical followed by chewing position and maximum intercuspation. Myocentric position and posterior border position were not symmetrical. (P<.05). 3. In comparison of bilateral symmetry of anterior temporal muscle, chewing position was the most symmetrical followed by posterior border position, maximum intercuspation, myocentric position and tapping position. However the differences were not statistically significant. 4. In comparison of proportionality of anterior temporal muscle to masseter muscle activity on left side, posterior border position was the greatest followed by myocentric position, taping position, chewing position and maximum intercuspation. And the proportionality of posterior border position was greater than that of maximum intercuspation. (P<.05). 5. In comparison of proportionality of anterior temporal muscle to masseter muscle activity on right side, myocentric position was the greatest followed by posterior border position, tapping position, maximum intercuspation and chewing position. However the differences were not statistically significant.

Analysis of Angular Velocity during Toe Tapping for the Quantification of the Lower Limb Bradykinesia in Patients with Idiopathic Parkinson's Disease (특발성 파킨슨병 환자의 하지 완서증 정량화를 위한 발 두드리기 동작의 각속도 분석)

  • Kim, Ji-Won;Kwon, Yu-Ri;Eom, Gwang-Moon;Kim, Hyung-Sik;Yi, Jeong-Han;Kwon, Do-Young;Koh, Seong-Beom;Park, Byung Kyu;Kwon, Tae-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.2114-2118
    • /
    • 2010
  • The purpose of this study was to analyze bradykinesia of toe tapping movement in patients with Parkinson's disease (PD) as compared to those of normal subjects. 39 PD patients (age: $65.5{\pm}11.2$ yrs, H&Y stage:$2.3{\pm}0.5$), 14 eldelry subjects with comparable mean age ($65.0{\pm}3.9$ yrs) and 17 healthy young subjects ($24.1{\pm}2.1$ yrs) participated in this study. Angular velocity during repetitive toe tapping movement was measured in both feet using a gyro sensor system. Suggested quantitative measures of bradykinesia were root-mean-squared (RMS) angular velocity, RMS angle, peak power and total power which were derived from the angular velocity signal. ANOVA showed that all measures were significantly different among three groups (p<0.001). Subsequent post-hoc test revealed that all measures in PD patients were significantly smaller than in healthy elderly and healthy young subjects (p<0.02). All measures were significantly correlated with UPDRS scores(r=-0.689~-0.825). These results suggest that the developed system can be used as quantitative measures of the lower limb bradykinesia in PD patients.