• Title/Summary/Keyword: Tapered

Search Result 905, Processing Time 0.023 seconds

Oral bisphosphonates induced osteonecrosis of the mandible : A case report

  • Son, Hyo-Jeong;Jang, Ho-Yeol;Keum, Yun-Seon;Lee, Jang-Yeol;Kim, Hyoun-Chull;Lee, Sang-Chull
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.2
    • /
    • pp.106-111
    • /
    • 2009
  • Bisphosphonates have been approved for Paget's disease, cancer-related hypercalcemia, bone involvement in multiple myeloma or solid tumors and osteoporosis. Although, underlying pathophysiological mechanisms remain unclear, it seems that bisphosphonates inhibit osteoclast precursor cells, modulate migratory and adhesive characteristics and induce apoptosis of osteoclasts. Furthermore impacts on angiogenesis, microenvironment and signal transduction between osteoclasts and osteoblasts. In this report, we present a case of oral bisphosphonates induced osteonecrosis of the mandible in a 84-year-old patient who received for two years. Two tapered screw vent implants(Zimmer, USA) were placed in the area of first and second molar. Two weeks later after crowns restored, some inflammatory signs and symptoms were observed on the second molar area. Sequestrum was formed and the sequestrum was removed with the implant. Frequent follow-up checks and oral hygiene maintenances were done and the first molar implant was restored. There is insufficient evidence suggests that duration of oral bisphosphonate therapy correlates with the development and severity of osteonecrosis. Therefore, dentists should not overlook the possibility of development of bisphosphonate induced osteonecrosis in patients who have taken oral forms of medication for less than three years.

Lateral approach for maxillary sinus membrane elevation without bone materials in maxillary mucous retention cyst with immediate or delayed implant rehabilitation: case reports

  • Han, Ji-Deuk;Cho, Seong-Ho;Jang, Kuk-Won;Kim, Seong-Gwang;Kim, Jung-Han;Kim, Bok-Joo;Kim, Chul-Hun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.4
    • /
    • pp.276-281
    • /
    • 2017
  • This case series study demonstrates the possibility of successful implant rehabilitation without bone augmentation in the atrophic posterior maxilla with cystic lesion in the sinus. Sinus lift without bone graft using the lateral approach was performed. In one patient, the cyst was aspirated and simultaneous implantation under local anesthesia was performed, whereas the other cyst was removed under general anesthesia, and the sinus membrane was elevated in a second process, followed by implantation. In both cases, tapered 11.5-mm-long implants were utilized. With all of the implants, good stability and appropriate bone height were achieved. The mean bone level gain was 5.73 mm; adequate bone augmentation around the implants was shown, the sinus floor was moved apically, and the cyst was no longer radiologically detected. Completion of all of the treatments required an average of 12.5 months. The present study showed that sufficient bone formation and stable implantation in a maxilla of insufficient bone volume are possible through sinus lift without bone materials. The results serve to demonstrate, moreover, that surgical treatment of mucous retention cyst can facilitate rehabilitation. These techniques can reduce the risk of complications related to bone grafts, save money, and successfully treat antral cyst.

A Study on the Fabrication and the Impedance Matching of SPUDT Type SAW Filter (단상 단방향 형태의 표면탄성파 필터 제작 및 임피던스 정합)

  • You Il-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.3
    • /
    • pp.602-608
    • /
    • 2005
  • We have studied to obtain the SAW filter for the Single Phase Unidirectional Transduce. (SPUDT), was formed on the Langasite substrate and was evaporated by Aluminum-Copper alloy and then we performed computer-simulated by simulator. We can fabricate that the block weighted type IDT as an input transducer of the filter and the withdrawal weighted type IDT as an output transducer of the filter from the results of our computer-simulations. Also, we have performed to obtain the properly conditions about impedance matching of the SAW filter for SPUDT. We have employed that the number of pairs of the input and output IDT are 50 pairs and the thickness and the width of reflector are 5000A and $3.6{\mu}m$, respectively. And the width of IDT' fingers is $2.4{\mu}m$, and the space between IDT' finger and reflector is $2.0{\mu}m$. Frequency response of the fabricated SAW filter has the property that the center frequency is about 190MHz and bandwidth at the 3dB is probably 7.7MHz after when we have matched impedance. Also, we could obtain that ripple characteristics is less than 0.4dB and standing wave ratio is probably 1.5 after when we have matched impedance.

High-Voltage Liquid-Electrolyte Microbatteries Inspired from Electric Eels (전기뱀장어의 전기발생을 모사한 고전압 액체 전해질 미소전지)

  • Kim, Mun-Chul;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.5
    • /
    • pp.469-473
    • /
    • 2009
  • We present high-voltage liquid-electrolyte microbatteries, inspired from the high-voltage generation mechanism of electric eels using serially connected multiple-cell arrays. In the microbatteries, we purge air into the electrolyte filled in a channel layer to isolate serially connected multiple cell arrays using three surface-tension valves (cell-front, outlet, and cell-end valves). Compared to the previous multi-cell stack or interconnection, present microbatteries provide a reduced multi-cell charging time. We have designed and characterized four different prototypes C1, C10, C20, and C40 having 1, 10, 20, and 40 cells, respectively. In the experimental study, the threshold pressures of cell-front, outlet, and cell-end valves were measured as $460{\pm}47$, $1,000{\pm}53$, and $2,800{\pm}170$ Pa, respectively. The average charging time for C40 was measured as $26.8{\pm}4.9$ seconds where the electrolyte and air flow-rates are 100 and $10{\mu}l/min$, respectively. Microbatteries showed the maximum voltage of 12 V (C40), the maximum power density of $110{\mu}W/cm^2$ (C40), and the maximum power capacity of $2.1{\mu}Ah/cm^2$ (C40). We also proposed a tapered-channel to remove the reaction gas from the cell chamber using a surface tension effect. The present microbatteries are applicable to high-voltage portable power devices.

A Development of NURBS-Based Pre and Post Processor for Structural Analysis of Free-Shaped Beam (자유형상 보요소 해석을 위한 NURBS기반의 전·후처리 모듈 개발)

  • Jung, Sung-Jin;Park, Se-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6673-6678
    • /
    • 2015
  • Recently, the free form buildings are constructed frequently. Exterior and interior components of these buildings have the free cross-section and a curved shape. So, There are many usages of classical finite element having tapered section and free-style shape. Some general commercial applications like ETABS, SAP2000, MIDAS are usually used for the safety evaluation of the free form structures. However, there are some limits in the accuracy of structural analysis and the length of analysis time because a very complicated finite element mesh have to be used. Therefore, In this study, a pre and post program module was developed to take advantage of general 3-D curved beam element which has a free-style curved shape and mathematical backgrounds. Pre-post processing module has been developed in this study was developed to control the curvature of the curved members by the NURBS control points. As a result, fast geometric modeling than was possible commercial applications. In addition, realistic depiction of the shape and behavior patterns were possible because of the free-form building allows visual check of the free form.

Stability Analysis of Concrete Plugs Using a 3-D Failure Criterion (3차원 파괴조건식을 이용한 콘크리트 플러그의 안전도 평가)

  • Lee, Youn-Kyou;Song, Won-Kyoung;Park, Chul-Whan;Choi, Byung-Hee
    • Tunnel and Underground Space
    • /
    • v.21 no.6
    • /
    • pp.526-535
    • /
    • 2011
  • A new failure criterion for concrete, which takes into account the effect of the intermediate principal stress, is proposed. The new criterion, which takes the advantages from both the Mohr-Coulomb and the Willam-Warnke criteria, is linear in the meridian section, while its octahedral section is always smooth and convex. Fitting the triaxial compression data with the proposed criterion shows the high performance of the new criterion. A new formula for the factor of safety of concrete is defined based on the new failure criterion and it is employed in the stability analysis of the concrete plugs installed in the pilot plant. The new formula for the factor of safety measures the degree of closeness of a stress state to the failure surface in the octahedral plane. Finally, 3-D finite element analyses of pilot plant were carried out to obtain the stress distributions in the plugs. Then, the stress distributions are converted to those of factor of safety by use of the proposed formula. Based on the distribution of factor of safety in the concrete plugs, the stability of the tapered and wedge-shaped plugs is evaluated.

Forehead Augmentation with a Methyl Methacrylate Onlay Implant Using an Injection-Molding Technique

  • Park, Dong Kwon;Song, Ingook;Lee, Jin Hyo;You, Young June
    • Archives of Plastic Surgery
    • /
    • v.40 no.5
    • /
    • pp.597-602
    • /
    • 2013
  • Background The forehead, which occupies about one third of the face, is one of the major determinants of a feminine or masculine look. Various methods have been used for the augmentation of the forehead using autologous fat grafts or alloplastic materials. Methylmethacrylate (MMA) is the most appropriate material for augmentation of the forehead, and we have used an injection-molding technique with MMA to achieve satisfactory results. Methods Under local anesthesia with intravenous (IV) sedation, an incision was made on the scalp and a meticulous and delicate subperiosteal dissection was then performed. MMA monomers and polymers were mixed, the dough was injected into the space created, and manual molding was performed along with direct inspection. This surgery was indicated for patients who wanted to correct an unattractive appearance by forehead augmentation. Every patient in this study visited our clinics 3 months after surgery to evaluate the results. We judged the postoperative results in terms of re-operation rates caused by the dissatisfaction of the patients and complications. Results During a 13-year period, 516 patients underwent forehead augmentation with MMA. With the injection-molding technique, the inner surface of the MMA implant is positioned close to the underlying frontal bone, which minimizes the gap between the implant and bone. The borders of the implant should be tapered sufficiently until no longer palpable or visible. Only 28 patients (5.4%) underwent a re-operation due to an undesirable postoperative appearance. Conclusions The injection-molding technique using MMA is a simple, safe, and ideal method for the augmentation of the forehead.

Endurance Life of Taper Roller Bearing for Wheel Loader Axles (휠 로더 차축 테이퍼 롤러 베어링의 내구수명)

  • Yoo, Dae Won;Lee, Jai Hak
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.11
    • /
    • pp.1323-1330
    • /
    • 2013
  • A wheel loader is a type of construction machinery that is capable of performing a variety of tasks, and demands on its functional diversity and structural reliability are growing. A wheel bearing is one of the core components that determine the life of the loader; taper roller bearings are commonly used for this purpose. The lifetime of a bearing is typically calculated based only on its load and revolution speed. The initial preload of a taper roller bearing is a critical factor that directly affects its endurance life. In this study, the relations between the endurance life and preload characteristics including the amount of preload according to the weight, rotational speed, and thermal modification applied to tapered roller bearings are presented. When the temperature is $100^{\circ}C$, an excessive preload condition is expected compared with that at room temperature, and the durable life decreases by 20.3 %.

Study on the Aerodynamic Analysis for Wings with Various Shapes Using Lifting-line Methods (양력선 방법을 이용한 다양한 형상의 날개 공력해석에 관한 연구)

  • Lee, Chang Ho;Kang, Hyung Min;Kim, Cheolwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.12
    • /
    • pp.931-939
    • /
    • 2013
  • In this paper, we try to find the lifting-line method which is applicable to the conceptual design of aircraft wings, and analyze the accuracy and coverage of the method. Two methods that are extended from the lifting-line theory of Prandtl are selected. One of the methods is Weissinger's method which imposes the velocity boundary condition at the control points located at the quarter chord, and the other is Phillips's method which combines the three-dimensional vortex lifting law. Calculations are performed for an elliptic wing, a swept back wing, and a tapered unswept wing with dihedral angle and geometric twist. The aerodynamic data of the potential flow such as spanwise distributions of circulation and downwash, lift and induced drag are obtained through calculations, and these data are compared with theoretical results and wind tunnel test data. As a result, Weissinger's method showed good accuracy and reliability regardless of wing shapes, but Phillips's method revealed inaccurate results for a swept back wing.

Single use Automatic Lancet to Minimize Pain During Skin Puncture (피부관통시 통증을 최소화하는 일회용 자동 모세혈액 채취기구)

  • 김현식;김경아;전명희;김태임;정용현;이태수;차은종
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.323-327
    • /
    • 2002
  • Chronic diabetic patients need to sample capillary blood for monitoring and controlling the blood sugar level. Frequent sampling requires to minimize pain during skin puncture. The present study developed mechanisms to minimize pain with effective sampling procedure. which consisted of tapered spring, guiding tunnel, and 30G needle Penetration depth was limited to within 2mm for pain reduction as well as for safety. Simple no-reuse mechanism also prevented the cross-patient and secondary infection possibility. Clinical experiments demonstrated the best convenience and safety with minimal pain in the diabetes, normal, and nursing students groups. Sing1e blood sampling was enough for successful blood sugar test by portable analyzer. The present sing1e use auto-lancet should be of great convenience in frequent capillary blood sampling for the diabetes.