• Title/Summary/Keyword: Tap-Power Estimation

Search Result 16, Processing Time 0.042 seconds

A Study on Individual Tap-Power Estimation for Improvement of Adaptive Equalizer Performance

  • Kim, Nam-Yong
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.1
    • /
    • pp.23-29
    • /
    • 2004
  • In this paper we analyze convergence constraints and time constant of IT-LMS algorithm and derive a method of making it's time constant independent of signal power by using input variance estimation. The method for estimating the input variance is to use a single-pole low-pass filter(LPF) with common smoothing parameter value, θ. The estimator is with narrow bandwidth for large θ but with wide bandwidth for small θ. This small θ gives long term average estimation(low frequency) of the fluctuating input variance well as short term variations (high frequency) of the input power. In our simulations of multipath communication channel equalization environments, the method with large θ has shown not as much improved convergence speed as the speed of the original IT-LMS algorithm. The proposed method with small θ=0.01 reach its minimum MSE in 100 samples whereas the IT-LMS converges in 200 samples. This shows the proposed, tap-power normalized IT-LMS algorithm can be applied more effectively to digital wireless communication systems.

Optimum Selection of Equalizer Taps Losing Noise Power Estimation (잡음 전력 추정을 이용한 등화기 탭의 최적 선택 방법)

  • 성원진;신동준
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.12A
    • /
    • pp.1971-1977
    • /
    • 2001
  • Multipath Rayleigh fading channels for mobile radio transmission can be represented by the linear filter model, and depending on the delay path characteristics, only a selected number of taps may have significance in the receiver structure design. By using tap-selective equalization, reduction in both processing complexity and power consumption can be obtained. In this paper, we present an optimal tap selection method for a given channel model, and demonstrate the performance improvement over an existing method. We show the method performs the CFAR (Constant False Alarm Rate) detection when the noise power information is available, and derive exact expressions of the error probability for the case of noise power estimation. Using the derived formulas and simulation results, it is demonstrated that the error probability quickly approaches to the optimal performance as the number samples used for the noise power estimation increases.

  • PDF

Real-Time Identification and Estimation of Transformer Tap Ratios Containing Errors

  • Kim, Hongrae;Kwon, Hyung-Seok
    • KIEE International Transactions on Power Engineering
    • /
    • v.2A no.3
    • /
    • pp.109-113
    • /
    • 2002
  • This paper addresses the issue of parameter error identification and estimation in electric power systems. Parameter error identification and estimation is carried out as a part of the state estimation. A two stage estimation procedure is used to detect and identify parameter errors. Suspected parameters are identified by the WLAV state estimator in the first stage. A new WLAV state estimator adding suspected system parameters in the state vector is used to estimate the exact values of parameters. Supporting examples are given by using the IEEE 14 bus system.

An Algorithm for Transformer Tap Estimation by WLAV State Estimator (가중최소절대값을 이용한 변압기 텝 추정 알고리즘)

  • Kim, Hong-Rae;Kwon, Hyung-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.279-281
    • /
    • 1999
  • This paper addresses the issues of the parameter error detection and identification in power system. The parameter error identification is carried out as part of the state estimation procedure. The weighted least absolute value(WLAV) estimation method is used for this procedure. The standard formulation of the state estimation problem is modified to include the effects of the parameter errors as well. A two step procedure for the detection and identification of faulted parameters is proposed. Supporting examples are given using IEEE 14 bus system.

  • PDF

Integrated Voltage/Var control based on Distributed Load Modeling with Distributed Generation in Distribution System (분산전원이 설치 된 배전 계통의 분포부하를 이용한 IVVC알고리즘)

  • Kim, Young-In;Lim, Il-Hyung;Choe, Myeon-Song;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.95_96
    • /
    • 2009
  • In this paper, a new algorithm of Integrated Volt/Var Control (IVVC) is proposed using Volt/Var control for the Distribution Automation System (DAS) based on the modeling of the distributed load and the distributed current. In the proposed, the load flow based on the modeling of the distributed load with Distributed Generation and the distributed current are estimated from constants of four terminals using the measurement of the current and power factor from a Feeder Remote Terminal Unit (FRTU). For Integrated Volt/Var Control (IVVC), the gradient method is applied to find optimal solution for tap and capacity control of OLTC (On-Load Tap Changers), SVR (Step Voltage Regulator), and SC (Shunt Condenser). What is more Volt/Var control method is proposed using moving the tie switch as well as IVVC algorithm using power utility control. In the case studies, the estimation and simulation network have been testified in Matlab Simulink.

  • PDF

The Optimal Volt/Var Control Algorithm with Distributed Generation of Distribution System (분산전원이 연계된 배전계통의 최적 전압/무효전력 제어 알고리즘)

  • Kim, Young-In;Lim, Il-Hyung;Choi, Myeon-Song;Lee, Seung-Jae;Lee, Sung-Woo;Ha, Bok-Nam
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.298-305
    • /
    • 2010
  • In this paper, a new algorithm of optimal Volt/Var Control is proposed using Volt/Var control for the Distribution Automation System (DAS) with Distributed Generation (DG) based on the modeling of the distributed load and the distributed current. In the proposed, algorithm based on the modeling of the distributed load and the distributed current are estimated from constants of four terminals using the measurement of the current and power factor from a Feeder Remote Terminal Unit (FRTU) and DG data from RTU for DG. For the optimal Volt/Var Control, the gradient method is applied to find optimal solution for tap, capacity and power control of OLTC (On-Load Tap Changers), SVR (Step Voltage Regulator), PC (Power Condenser) and DG (Distributed Generation). In the case studies, the estimation and control of the voltages have been testified in a radial distribution system with DG using matlab program.

A study on narrowband interference rejection in PN spread spectrum communication system (PN 대역 확장 통신시스템에서 협대역 간섭신호의 제거방식에 관한 연구)

  • 김동길;김원후
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1983.10a
    • /
    • pp.85-87
    • /
    • 1983
  • In this paper, a improved whitening filter for narrowband interference rejetion in PN spread spectrum communication systems is proposed. This whitening filter has the feedback from the output to the input of adaptive transversal filter and is superior to conventional LMS whitening filter in respect to SNR and power spectrum since the calculation of tap weight is based on maximum likelihood estimation

  • PDF

Design of 2-D MA FIR Filters for Channel Estimation in OFDM Systems

  • Park, Ji-Woong;Lee, Seung-Woo;Lee, Yong-Hwan
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.234-237
    • /
    • 2003
  • The accuracy of channel estimation significantly affects the performance of coherent OFDM receiver. It is desirable to employ a good channel estimator while requiring low implementation complexity. In this paper, we propose a channel estimator that employs a simple two-dimensional (2-D) moving average (MA) filter as the channel estimation filter. The optimum tap size of the 2-D MA FIR filter is analytically designed in the time and frequency domain in association with the channel condition and pilot signal to interference power ratio. The analytic results can be applied to the design of adaptive channel estimator. Finally, the performance of the proposed channel estimator is verified by computer simulation.

  • PDF

Integrated Volt/Var Control Algorithm based on the Distributed Load Modeling of Distribution Network (배전계통의 분포 부하 모델링을 통한 최적화 IVVC 알고리즘)

  • Kim, Young-In;Lim, Il-Hyung;Choi, Myeon-Song;Lee, Seung-Jae;Lee, Sung-Woo;Kwon, Sung-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1463-1471
    • /
    • 2009
  • In this paper, a new algorithm of Integrated Volt/Var Control (IVVC) is proposed using Volt/Var control for the Distribution Automation System (DAS) based on the modeling of the distributed load and the distributed current. In the proposed, the load flow based on the modeling of the distributed load and the distributed current are estimated from constants of four terminals using the measurement of the current and power factor from a Feeder Remote Terminal Unit (FRTU). For Integrated Volt/Var Control (IVVC), the gradient method is applied to find optimal solution for tap and capacity control of OLTC (On-Load Tap Changers), SVR (Step Voltage Regulator), and SC (Shunt Condenser). What is more Volt/Var control method is proposed using moving the tie switch as well as IVVC algorithm using power utility control. In the case studies, the estimation and simulation network have been testified in Matlab Simulink.

Analysis of Factors and it's Effectiveness to Maintenance Cost of Public Buildings (공공청사의 운영비용에 영향을 미치는 요인과 요인별 영향력 분석)

  • Ko, Kyujin;Cho, Sangouk;Hwang, Jeongha;Lee, Chansik
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.2
    • /
    • pp.29-37
    • /
    • 2015
  • Multi-household buildings are efficiently maintained from the mid- and long-term viewpoint according to the long-term repair coverage system etc. On the other hand, public buildings are not systematically maintained due to a lack of past maintenance cost data and inefficient budget plans, among other problems. Targeting public buildings in Incheon, this study analyzed operation costs variables. To verify the analysis results, they underwent a correlation analysis and a multi-regression analysis. With regard to public buildings electricity, gas and tap water cost, the influence power of the served life, floor area, and workforce were analyzed, revealing that electricity cost was highly correlated with workforce, while gas and tap water cost were correlated with tap water cost. Also, the correlation analysis results were verified through a multi-regression analysis, and a maintenance cost estimation model was presented using a regression equation.