• Title/Summary/Keyword: Tap

Search Result 1,809, Processing Time 0.024 seconds

A Study on the Electrical Discharge Blind Hole Tap Machining of STD11 with Copper Electrode (구리전극봉을 이용한 합금공구강재(STD11)의 비관통 방전 탭 가공에 관한 연구)

  • Park, In-Soo;Wang, Duck-Hyun;Kim, Gi-Tae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.3
    • /
    • pp.38-44
    • /
    • 2017
  • The technology of electrical discharge tap machining may be appropriate for making thread out of highly brittle material. Especially, it is very difficult to machine tap with the traditional method if the brittle material has been hardened by quenching. In this study, the shape of electrical discharge blind hole tap machining was analyzed by discharge time, discharge current, and the flushing hole condition after quenched the tool steel of STD11 has discharged the tap shape with a screw-shaped copper(Cu) electrode. An experimental design was planned and analyzed by Taguchi robust experimental design. The result showed that the shape of the blind hole discharge tap was influenced by the flushing hole, discharge time, and discharge current. The most important factor of the processing conditions was found to be the discharge current. When blind hole EDM with a copper electrode with a flushing hole was conducted, the discharged shape was found to be smooth and the angle of the discharged tapped thread was also found to be close to the thread angle of $60^{\circ}$. As the values of discharge time and discharge current increased, the EDMed surface coarsened due to the increase of the single discharge energy and the shape of the thread collapsing.

Mutagenic Activity of Organic Pollutans in Drinking Water in Seoul (수도권 상수중 유기오염물질의 돌연변이원성)

  • Shin, Dong-Chun;Jang, Jae-Yeon;Jo, Seong-Joon;Chung, Yong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.2 s.24
    • /
    • pp.284-294
    • /
    • 1988
  • To measure the mutagenic activity of micro-organic pollutants in drinking water, mutagenicity test was conducted using Salmnella typhimurium TA 98 strain on the water sample taken from three water supply stations and six tap water in Seoul in July and November 1987. The results were as follows : 1. The average amounts of organic matters in raw, treated, and tap water sampled in July were 0.38mg/l, 0.28mg/l, and 0.45mg/l. respectively, and sampled in November were 0.34mg/l, 0.24mg/l, and 0.22mg/l, respectively. The amount of organic matters of tap water sampled in November did not increase while that of tap water sampled in July increased compare to those of raw or treated water. 2. The amount of organic matters is the highest in neutral fraction compare to acidic and basic fractions. 3. In the five out of six tap water and raw water of Paldang and Kuui station sampled in July, the mutagenicity ratios were greater then two (both direct and indirect mutagenicity). 4. In the three out of six tap water and raw and treated water of Kuui station sampled in November, the mutagenicity ratios were greater than two. 5. While mutagenic activities were low in acidic and basic fraction, they were high in neutral fraction. The samples which had high mutagenic acitivity in the total amount also showed high mutagenic activity in neutral fraction. 6. While mutagenic acitivity was decreased after the treatement of water, it was increased in tap water as the distance from the water supply station increases.

  • PDF

Photosynthetic Responses and Photoprotection in Korean Hot Pepper (Capsicum annuum L.) against High Light Stress (광 스트레스에 대한 고추 잎의 광합성 반응과 광 보호 메커니즘)

  • Lee, Hae-Youn;Park, Youn-Il;Kim, Chang-Gi;Hong, Young-Nam
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.2
    • /
    • pp.109-117
    • /
    • 2006
  • Photoinhibition and photoprotection of PSII in the leaves of hot pepper (Capsicum annuum L.) grown in Hoagland solution and Tap water were compared. Though changes in the rates of $O_2$ evolution as a function of photon fluence rate (PFR) were comparable, the rates of respiration in the dark was 3 times higher in the Hoagland solution grown leaves than in the Tap-water grown ones. Compared to Hoagland solution grown plane, PSIIs of Tap water grown pepper leaves were more susceptible to photoinhibitory light treatment. In order to inactivate functional PSII to the same extents, Hoagland solution grown plants required almost 2-fold high light $(1600{\mu}molm^{-2}s^-)$ treatment than those of Tap water $(900{\mu}molm^{-2}s^-)$. Interestingly, the remaining fraction of PSII in Hoagland grown pepper was able to survive under prolonged illumination in the presence of lincomycin, which probably means that the growth condition of plant seemed to have an effect on the recovery of PSII from light stress. When PSII was severly photoinactivated at a chilling temperature, recovery was observed only if the residual functional PSII were not inhibited with DCMU, Nigericin and MV during recovery. In conclusion, PSIIs grown in the Hoagland solution was more resistant to excess light than in the Tap water grown one and the recovery of PSII from photodamage was more efficient in Hoagland grown pepper leaves than Tap water grown one, which means that the increased dark respiration may play a important role in the protection of PSII from photoinhibition by helping repair photosynthetic proteins (in particular, the D1 protein of PSII) degraded by photoinhibition.

A Study on Heavy Metals at the Consumer s Tap in Seoul (서울市 一部 水道栓水中 重金屬에 관한 調査硏究)

  • Lee, Byung Mu
    • Journal of Environmental Health Sciences
    • /
    • v.10 no.2
    • /
    • pp.41-51
    • /
    • 1984
  • This study was performed using samples collected at Myungryundong and at Reservoirs. The purpose of this study was to investigate the differences of water quality between tap and raw water, and to analyse drinking water quality by Fe, Zn from corroded galvanized steel pipe. Results were as follows 1. The older the pipe was, the higher the concentration of Ferrum and Zinc was (t-test : p<0.05). Ferrum and Zinc also exceeded the limits in the older galvanized steel pipe. I think that this comes from the corrosion of pipe. 2. Mercury, Arsenic, Cadmium, Lead, Chomium, Argentum and Aurum not detected in raw water were not detected in tap water. Cobalt, Bismuth and Molybudenum detected in raw water were not detected in tap water. I think that this comes from the quality of raw water, the result of water treatment and the improbability of detection of above metals in water delivery system. 3. Silicon measured 2.4698ppm in raw water, but it ranged from 0.4769ppm to 1.982 ppm in tap water. Manganese measured 0.0638ppm in raw water, but it ranged from 0.0026ppm to 0.0198ppm in 17cases(31%) out of 55samples in tap water. I think that this comes from the water treatment. 4. Aluminium not detected in raw water was found in 17 cases (31%) out of the samples (55cases). It may be considered as the use of coagulants $Al_2(SO_4)_3$. $18H_2O$ and PAC (Poly Aluminium Chloride). The concentration of copper in tap water was much higher in 2 cases(3.6%) out of the samples(55) than that of copper in raw water. I think that this may come from the use of ${CuSO}_4$, the preventive of algae growth, and the result of chlorination, but further study must be necoessary to support the proof.

  • PDF

Study on the Chlorine-Resistant Bacteria Isolated from Water Pipe Network (상수도관망에서 분리한 잔류염소 내성균에 관한 연구)

  • Hyun, Jae-Yeoul;Yoon, Jong-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.3
    • /
    • pp.334-341
    • /
    • 2011
  • The free residual chlorine of tap water samples, collected from 266 faucets on the water pipe network in Daegu City, was between 0.1 and 0.79 mg/L. On microorganic tests, general bacteria and the coliform goup were not detected and thus the tap water was turned out to be fit to drink. In particular, samples of which free residual chlorine was 0.1 mg/L and over were cultured in R2A agar media at $25^{\circ}C$ for 7 days, and as a result heterotrophic bacteria were detected in 65.9% of samples; (1). The closer tap water got to the faucet from the stilling basin, the lower residual chlorine concentration became but the more the bacterial count became. And, more bacteria were detected in the R2A agar medium than in the PCA medium. (2). In the case of separated strains, most colonies were reddish or yellowish. 16S rRNA sequence was identified as Methylobacterium sp. and Williamsia sp., and yellow strain was identified as Sphingomonas sp., Sphingobium sp., Novosphingobium sp., Blastomonas sp., Rhodococcus sp. and Microbacterium sp. White strain was identified as Staphylococcus sp. (3). Sterilized tap water in polyethylene bottles was inoculated with separated strain and was left as it was for 2 months. As a result, bio-film was observed in tap water inoculated with Methylobacterium sp. and Sphingomonas sp. It was found that heterotrophic bacteria increased when free residual chlorine was removed from tap water in the water pipe network. Thus, there is a need to determine a base value for heterotrophic bacteria in order to check the cleanliness of tap water in the water pipe network.

Regional Background Levels of Carbon Monoxide Observed in East Asia during 1991~2004 (1991~2004년 동아시아에서 관측한 일산화탄소의 지역적 배경 농도)

  • Kim, Hak-Sung;Chung, Yong-Seung
    • Journal of the Korean earth science society
    • /
    • v.27 no.6
    • /
    • pp.643-652
    • /
    • 2006
  • Data of the carbon monoxide concentration observed in Mt. Waliguan in China (WLG), Ulaan Uul in Mongolia (UUM), Tae-ahn Peninsula in Korea (TAP), and Ryori in Japan (RYO) were analyzed for a long period between 1991 and 2004. The annual average concentration of carbon monoxide was the highest at TAP $(233{\pm}41ppb)$ followed by $RYO(171{\pm}36ppb),\;UUM(155{\pm}26ppb),\;and\;WLG(135{\pm}22ppb)$. The seasonal variations being high in spring and low in summer were observed in other areas of Eastern Asia except WLG. TAP was high in carbon monoxide concentration in all seasons compared to WLG, UUM and RYO and shows wide distribution of concentration in the histogram, which is caused by the influence of large-scale air pollution due to its downwind location close to the East Asian continent, China in particular. Also, our data was compared with data measured at Mauna Loa (MLO) in Hawaii. According to the origin of the isentropic backward trajectory and its transport passage, carbon monoxide concentration observed in TAP was analyzed as follows: continental background airflows (CBG) were $216{\pm}47ppb$; regionally polluted continental airflows (RPC) were $316{\pm}56ppb$; Oceanic background airflows (OBG) were $108{\pm}41ppb$; and Partly perturbed oceanic airflows (PPO) were $161{\pm}6ppb$. The high concentration of carbon monoxide in TAP is due to the airflow from East Asian continent origin rather than that from the North Pacific origin. Especially, RPC which passes through the eastern China appeared to be the highest in concentration in spring, fall, and winter. However, OBG was affected by the North Pacific air mass with a low carbon monoxide concentration in summer. The NOAA satellite images and GEOS-CHEM model simulation confirmed a large-scale air pollution event that was in the course of expansion from southeastern China bound to the Korean Peninsula and the Korea East Sea by way of the Yellow Sea.

Galvanic Corrosion Behavior between Carbon Steel Bolted GECM(Graphite Epoxy Composite Material)/Al plates (탄소강 볼트 체결된 GECM(Graphite Epoxy Composite Material)/Al 판재 간의 갈바닉 부식 거동)

  • Kim, Youngsik;Park, Sujin;Yoo, Youngran
    • Corrosion Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.12-26
    • /
    • 2013
  • This work focused on galvanic corrosion of carbon steel bolted GECM/Al plates by long-term test in tap water and NaCl solutions. Test product was carbon steel bolted between cross packed GECM and painted aluminium. Tests for the product and coupled parts determined corrosion rate in tap water and NaCl solutions. Also, using a potentiostat and salt water sprayer, galvanic test was done. In galvanic test on carbon steel bolted GECM/Al plates, corrosion of carbon steel bolt was faster in series of tap water>1% NaCl solution>3.5% NaCl solution. In galvanic couple between aluminium and carbon steel bolt, their corrosion rates were higher than those of single specimen. In galvanic couple between GECM, aluminium, and carbon steel bolt, corrosion behaviors of carbon steel bolt and aluminium were changed due to different corrosion mechanism in tap water and chloride solution.

Changes of Tap Water from the Preparation of Green Tea Leaves (녹차엽 주입에 따른 수돗물의 수질 변화)

  • Kim Chang Mo;Park Hyeon;Chang Hyun Seong;Kim Hyun Suk
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.1 s.88
    • /
    • pp.53-59
    • /
    • 2006
  • This study was carried out to investigate the physicochemical characteristics with the elapsed time of $1\~10$ minutes after adding green tea leaves in the tap water. The results are summarized as follows: 1. $UV_{254}$ measurement increased sharply in direct opposition to increasing conductivity slowly. It is expected that the water soluble organic matters were better extracted than minerals. 2. Residual chlorine decay coefficients evaluated by assuming first-order reaction was increased in proportion to adding weights of green tea leaves. 3. In DBP formation experiments, residual chlorine decreased when reaction time was elapsed. whereas DBPs such as HAAs and THMs increased with the passing of time. From these results, it was showed that residual chlorine decay was related with the formation of DBPs. Therefore, use of boiled tap water in preparation of green tea is suggested if the residual chlorine in the tap water is high.

Genomic Fingerprinting Patterns of Bifidobacteria Isolated from Healthy Koreans Using ERIC-, TAP-, and BOX-PCR (건강한 한국인으로부터 분리된 비피도박테리아의 ERIC-, TAP-, BOX- 중합효소연쇄반응을 이용한 유전자 지문 분석)

  • Lee, Do-Kyung;Kang, Byung-Yong;Chung, Myung-Jun;Lee, Kang-Oh;Kim, Kyung-Jae;Ha, Nam-Joo
    • Environmental Analysis Health and Toxicology
    • /
    • v.23 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • 유산균인 비피도박테리아는 사람과 동물에서 유익한 프로바이오틱 미생물로 알려져 있다. 본 연구에서는 이러한 비피도박테리아 균주의 분류를 위한 repetitive DNA element PCR fingerprinting (ERIC-또는 TAP-PCR)의 사용을 평가하였다. 사람분변으로부터 분리한 알려지지 않은 비피도박테리움 균주와 한국생명공학연구원 생물자원센터로부터 분양받은 표준균주를 가지고 분류 및 동정에 ERIC-PCR과 TAP-PCR을 이용한 RAPD-fingerprinting을 수행하였다. 그 결과 비피도박테리움 균주에 대한 속과 종단위의 분류가 가능하였으며, 실험에 사용된 모든 비피도박테리움 균주는 RAPD-fingerprinting 분석을 통해 유전적 다양성을 확인하였다. 또한 ERIC2와 TAP1 프라이머를 이용한 실험에서는 Bifidobacterium adolescenits 특이 유전자 단편을 확인하였으며 이는 B. adolescenits 균주의 동정에 유용할 것으로 사료된다.

Vessel Elements of Panax ginseng C.A. Meyer (인삼 (Panax ginseng C.A. Meyer)의 도관요소)

  • 정병갑
    • Journal of Plant Biology
    • /
    • v.31 no.3
    • /
    • pp.169-185
    • /
    • 1988
  • Vessel elements in lateral root, tap root, transition region, stem and mid vein of 1-year old, 3-year old and 5-year old ginseng (Panax ginseng C.A. Meyer) are studied with light microscope to clarify the distribution and differentiation of several kinds of vessel elements. Vessel elements are classified into five types such as ring vessel, spiral vessel, scalariform vessel, reticulate vessel and pitted vessel according to the secondary thickenings of cell wall. All of the five types are not observed in each organ, but diverse kinds of vessels are present in stem and mid vein compared with the underground organs such as tap root and lateral root. The length of vessel elements is longest (680$\mu$m) in stem and shortest (143$\mu$m) in tap root. The diameter of vessel elements is 19.0$\mu$m in tap root and the angle of perforation plate comes under 22$^{\circ}$-60$^{\circ}$. The degree of differentiation of vessel elements according to the length, diameter and angle of perforation plate of vessel elements is highest in tap root regardless of the age of ginseng. Three types of perforation plate such as scalariform, intermediate type of simple and scalariform, and simple perforation plate are observed. The vascular tracheids are characteristically observed in mid vein of 1-year old ginseng, and in transition region of 3 and 5-year old ginseng.

  • PDF