• 제목/요약/키워드: Tandem reaction

검색결과 175건 처리시간 0.022초

Pentafluorophenylprophyl Ligand-based Liquid Chromatography-Tandem Mass Spectrometric Method for Rapid and Reproducible Determination of Metformin in Human Plasma

  • Yang, Jeong Soo;Oh, Hyeon Ju;Jung, Jin Ah;Kim, Jung-Ryul;Kim, Tae-Eun;Ko, Jae-Wook;Lee, Soo-Youn;Huh, Wooseong
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권11호
    • /
    • pp.3284-3288
    • /
    • 2013
  • This paper describes first development and validation of pentafluorophenylprophyl ligand-based liquid chromatography coupled to tandem mass spectrometry (PFPLC-MS/MS) method to determine metformin, a highly polar compound, in human plasma. Metformin and Phenformin (internal standard) were extracted from human plasma 50 ${\mu}L$ with a single-step protein precipitation. The chromatographic separation was performed using a linear gradient elution of mobile phase involving 5.0 mM ammonium formate solution with 0.1% formic acid (A) and acetonitrile (B) over 3.0 min of run time on a Phenomenex Luna PFP column. The detection was performed using a triple-quadrupole tandem mass spectrometer (Waters Quattro micro) with electrospray ionization in the mode of positive ionization and multiple-reaction monitoring (MRM). The developed method was validated with 5.0 ng/mL of lower limit of quantification (LLOQ). The calibration curve was linear over 5-3000 ng/mL of the concentration range ($R^2$ > 0.99). The specificity, selectivity, carry-over effect, precision, accuracy and stability of the method met the acceptance criteria. The method developed in this study had had rapidness, simplicity and ruggedness. The reliable method was successfully applied to high throughput analysis of real samples for a practical purpose of a pharmacokinetic study.

Treadmill에서의 보행 및 주행 시의 수직 지면반발력 (Vertical ground reaction force in the treadmill walking and running)

  • 양길태;김영호;임송학
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.339-342
    • /
    • 1996
  • Vertical ground reaction forces on a treadmill were measured at different walking speeds using two tandem force plates. Comparing vertical ground reaction forces in treadmill walking with those in ground free walking, treadmill walking overestimated the first and second peak forces. With the increase of the walking speed, this phenomenon becomes more significant. In treadmill running, the first peak force reached 210-280% of the body weight. However, the instrumented treadmill showed a great potential to investigate the kinetics for multiple foot-strike measurements.

  • PDF

An Efficient Synthesis of Substituted Quinolines via Indium(III) Chloride Catalyzed Reaction of Imines with Alkynes

  • Zhu, Mei;Fu, Weijun;Xun, Chen;Zou, Guanglong
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권1호
    • /
    • pp.43-47
    • /
    • 2012
  • An efficient synthetic method for the preparation of quinolines through indium(III) chloride-catalyzed tandem addition-cyclization-oxidation reactions of imines with alkynes was developed. The processes can provide a diverse range of quinoline derivatives in good yields from simple imines and alkynes.

Gas Chromatography/Mass Spectrometry and Gas Chromatography/Tandem Mass Spectrometry of some s-Triazine Pesticides

  • Kim, Yoo-Joong;Kim, Myung-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • 제10권2호
    • /
    • pp.196-200
    • /
    • 1989
  • Some s-triazine herbicides, namely simazine, atrazine, and propazine present as trace components in a complex mixture were analyzed by GC/MS and GC/MS/MS methods. Even though monitoring the molecular ions was the best in terms of sensitivity, adequate analysis could not be done when interfering species were present. When doubly charged ions which appeared at characteristic m/z values were monitored, chromatograms were rather free from interference. More importantly, selected reaction monitoring was found to provide a selective means of detection with general applicability.

중합효소연쇄반응을 이용한 닭 종양성 질병의 감별진단에 관한 연구 (Differential diagnosis among Marek's disease, reticuloendotheliosis and avian leukosis by polymeras chain reaction)

  • 성환우;김선중
    • 대한수의학회지
    • /
    • 제38권1호
    • /
    • pp.101-106
    • /
    • 1998
  • The present study attempted to apply polymerase chain reaction (PCR) to develop a rapid differential diagnosis among Marek's disease, reticuloendotheliosis and avian leukosis. The primers chosen to detect Marek's disease virus (MDV) flank the 132bp tandem direct repeat of the MDV genome. The primers selected for reticuloendotheliosis virus (REV) and avian leukosis virus (ALV) are based on proviral long terminal repeats of spleen necrosis virus and Rous-associated virus-2 genomes, respectively. The specific PCR products of MDV, REV and ALV were observed with each primer and the reaction was not cross-reacted among the viruses. MDV-specific DNA was also amplified from the MDV-induced lymphoma (MDCC-MSB1) but not from the REV-induced tumor and ALV-induced lymphoma (LSCC-1104B1). In addition, proviral DNA of REV from REV-induced tumor and proviral DNA of ALV from ALV-induced lymphoma were also amplified by REV-specific and ALV-specific PCRs, respectively. Therefore these three PCR methods may be used to rapidly differentiate among MDV, REV and ALV-associated tumors in diagnosis.

  • PDF

Keratanase II Digestion Accompanied with a Liquid Chromatography/Tandem Mass Spectrometry for Urinary Keratan Sulfate Quantitative Analysis

  • Chuang, Chih-Kuang;Lin, Hsiang-Yu;Wang, Tuen-Jen;Huang, Sung-Fa;Lin, Shuan-Pei
    • Journal of mucopolysaccharidosis and rare diseases
    • /
    • 제3권1호
    • /
    • pp.20-27
    • /
    • 2017
  • Purpose: Mucopolysaccharidosis IV (MPS IV) is a disease characterized by deficient activity of N-acetylgalactosamine-6-sulfatase (GALNS) causing excessive lysosomal storage of keratan sulfate (KS). The identification of the relevant disaccharide units of KS after keratanase II digestion followed by liquid chromatography/tandem mass spectrometry detection (LC-MS/MS) is validated and applicable for the preliminary diagnosis of MPS IV. Methods: A total of 67 urine samples were collected and analyzed from 11 MPS IV patients comprising 10 MPS IVA and one MPS IVB patients, and 56 normal controls. Urinary glycosaminoglycan was first precipitated by the Alcian blue method followed by a digestion of keratanase II. The protonated species of the digested disaccharide products were detected by using multiple reaction monitoring experiment. Results: One particular disaccharide of KS was selected. The transition mass-to-charge (m/z) of the parent ion and its daughter ion after collision was $462.0{\rightarrow}97.0$, whereas the chondrosine used as an internal standard in this assay was m/z $353.9{\rightarrow}73.0$. The results corresponded well with the two-dimensional electrophoresis method. The quantities of urinary KS were significantly raised in confirmed MPS IV patients when comparing with those of normal controls ($170.2{\pm}81.1$ vs. $4.06{\pm}1.92{\mu}g/mL$). Conclusion: The LC-MS/MS method for MPS IVA determination is specific, sensitive, validated, and applicable for urinary KS quantification. This method can be used not only as a first-line biochemistry examination of MPS IVA, but also as an outcome survey after enzyme replacement therapy.

Determination of Tiapride in Human Plasma Using Hydrophilic Interaction Liquid Chromatography-Tandem Mass Spectrometry

  • Moon, Ya;Paek, In-Bok;Kim, Hui-Hyun;Ji, Hye-Young;Lee, Hye-Won;Park, Hyoung-Geun;Lee, Hye-Suk
    • Archives of Pharmacal Research
    • /
    • 제27권9호
    • /
    • pp.901-905
    • /
    • 2004
  • A rapid, sensitive and selective hydrophilic interaction liquid chromatography-tandem mass spectrometric(HILIC-MS/MS) method for the determination of tiapride in human plasma was developed. Tiapride and internal standard, metoclopramide were extracted from human plasma with dichloromethane at basic pH and analyzed on an Atlantis HILIC silica column with the mobile phase of acetonitrile-ammonium formate (190 mM, pH 3.0) (94:6, v/v). The ana-Iytes were detected using an electrospray ionization tandem mass spectrometry in the multi-ple-reaction-monitoring mode. The standard curve was linear (r=0.999) over the concentration range of 1.00-200 ng/mL. The coefficient of variation and relative error for intra- and inter-assay at three QC levels were 6.4∼8.8% and -2.0∼3.6%, respectively. The recoveries of tiapride ranged from 96.3 to 97.4%, with that of metoclopramide (internal standard) being 94.2%. The lower limit of quantification for tiapride was 1.00 ng/mL using 1 00 $\mu$L of plasma sample.

HPLC-tandem Mass Spectrometric Analysis of the Marker Compounds in Forsythiae Fructus and Multivariate Analysis

  • Cho, Hwang-Eui;Ahn, Su-Youn;Son, In-Seop;Hwang, Gyung-Hwa;Kim, Sun-Chun;Woo, Mi-Hee;Lee, Seung-Ho;Son, Jong-Keun;Hong, Jin-Tae;Moon, Dong-Cheul
    • Natural Product Sciences
    • /
    • 제17권2호
    • /
    • pp.147-159
    • /
    • 2011
  • A high-performance liquid chromatography-electrospray ionization-tandem mass spectrometric method was developed to determine simultaneously eight marker constituents of Forsythiae fructus, and subsequently applied it to classify its two botanical origins. The marker compounds of Forsythia suspensa were phillyrin, pinoresinol, phillygenin, lariciresinol and forsythiaside; those of F.viridissima were arctiin, arctigenin and matairesinol. Separation of the eight analytes was achieved on a phenyl-hexyl column (150${\times}$2.0 mm i.d., 3 ${\mu}M$) using gradient elution with the mobile phase: (A) 10% acetonitrile in 0.5% acetic acid, (B) 40% aqueous acetonitrile. A few fragment ions specific to the types of lignans, among the product ions generated by collisonally induced dissociation (CID) of molecular ion clusters, such as [M-H]$^-$ or [M+OAc]$^-$ were used not only for fingerprinting analysis but for the quantification of each epimer by using multiple-reaction monitoring mode. It was shown good linearity ($r^2{\geq}$ 0.9998) over the wide range of all analytes; intra- and inter-day precisions (RSD, %) were within 9.14% and the accuracy ranged from 84.3 to 115.1%. The analytical results of 40 drug samples, combined with multivariate statistical analyses - principal component analysis (PCA) and hierarchical cluster analysis (HCA) - clearly demonstrated the classification of the test samples according to their botanical origins. This method would provide a practical strategy for assessing the authenticity or quality of the herbal drug.

Rapid Determination of Imatinib in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study

  • Yang, Jeong Soo;Cho, Eun Gi;Huh, Wooseong;Ko, Jae-Wook;Jung, Jin Ah;Lee, Soo-Youn
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권8호
    • /
    • pp.2425-2430
    • /
    • 2013
  • A simple, fast and robust analytical method was developed to determine imatinib in human plasma using liquid chromatography-tandem mass spectrometry with electrospray ionization in the positive ion mode. Imatinib and labeled internal standard were extracted from plasma with a simple protein precipitation. The chromatographic separation was performed using an isocratic elution of mobile phase involving 5.0 mM ammonium formate in water-5.0 mM ammonium formate in methanol (30:70, v/v) over 3.0 min on reversed-stationary phase. The detection was performed using a triple-quadrupole tandem mass spectrometer in multiple-reaction monitoring mode. The developed method was validated with lower limit of quantification of 10 ng/mL. The calibration curve was linear over 10-2000 ng/mL ($R^2$ > 0.99). The method validation parameters met the acceptance criteria. The spiked samples and standard solutions were stable under conditions for storage and handling. The reliable method was successfully applied to real sample analyses and thus a pharmacokinetic study in 27 healthy Korean male volunteers.

Determination of Glimepiride in Human Plasma by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry

  • Kim, Ho-Hyun;Chang, Kyu-Young;Lee, Hee-Joo;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권1호
    • /
    • pp.109-114
    • /
    • 2004
  • A sensitive method for quantitation of glimepiride in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Glipizide was used as an internal standard. Glimepiride and internal standard in plasma sample was extracted using diethyl etherethyl acetate (1 : 1). A centrifuged upper layer was then evaporated and reconstituted with the mobile phase of acetonitrile-5 mM ammonium acetate (60:40, pH 3.0). The reconstituted samples were injected into a $C_{18}$ reversed-phase column. Using MS/MS in the multiple reaction monitoring (MRM) mode, glimepiride and glipizide were detected without severe interference from human plasma matrix. Glimepiride produced a protonated precursor ion ([M+H]$^+$) at m/z 491 and a corresponding product ion at m/z 352. And the internal standard produced a protonated precursor ion ([M+H]]$^+$) at m/z 446 and a corresponding product ion at m/z 321. Detection of glimepiride in human plasma by the LC-ESI/MS/MS method was accurate and precise with a quantitation limit of 0.1 ng/mL. The validation, reproducibility, stability, and recovery of the method were evaluated. The method has been successfully applied to pharmacokinetic studies of glimepiride in human plasma.