• 제목/요약/키워드: Tandem Mass Spectrometry

검색결과 583건 처리시간 0.028초

Gas Chromatography/Mass Spectrometry and Gas Chromatography/Tandem Mass Spectrometry of some s-Triazine Pesticides

  • Kim, Yoo-Joong;Kim, Myung-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • 제10권2호
    • /
    • pp.196-200
    • /
    • 1989
  • Some s-triazine herbicides, namely simazine, atrazine, and propazine present as trace components in a complex mixture were analyzed by GC/MS and GC/MS/MS methods. Even though monitoring the molecular ions was the best in terms of sensitivity, adequate analysis could not be done when interfering species were present. When doubly charged ions which appeared at characteristic m/z values were monitored, chromatograms were rather free from interference. More importantly, selected reaction monitoring was found to provide a selective means of detection with general applicability.

Simultaneous Quantitative Determination of Nine Hallucinogenic NBOMe Derivatives in Human Plasma Using Liquid Chromatography Tandem Mass Spectrometry

  • Seo, Hyewon;Yoo, Hye Hyun;Kim, Young-Hoon;Hong, Jin;Sheen, Yhun Yhong
    • Mass Spectrometry Letters
    • /
    • 제10권1호
    • /
    • pp.18-26
    • /
    • 2019
  • We developed a bioanalytical method for simultaneous determination of nine NBOMe derivatives (25H-NBOMe, 25B-NBOMe, 25E-NBOMe, 25N-NBOMe, 25C-NBOH, 25I-NBOH, 25B-NBF, 25C-NBF, and 25I-NBF) in human plasma using liquid chromatography tandem mass spectrometry (LC-MS/MS). Human plasma samples were pre-treated using solid-phase extraction. Separation was achieved on a C18 column under gradient elution using a mobile phase containing 0.1% formic acid in acetonitrile and 0.1% formic acid in water at a flow rate of 0.3 mL/min. Mass detection was performed in the positive ion mode using multiple reaction monitoring. The calibration range was 1-100 ng/mL for all quantitative analytes, with a correlation coefficient greater than 0.99. The intra- and inter-day precision and accuracy varied from 0.85 to 6.92% and from 90.19 to 108.69%, respectively. The recovery ranged from 86.36 to 118.52%, and the matrix effects ranged from 27.09 to 99.72%. The stability was acceptable in various conditions. The LC-MS/MS method was validated for linearity, accuracy, precision, matrix effects, recovery and stability in accordance with the FDA guidance. The proposed method is suitable for reliable and robust routine screening and analysis of nine NBOMe derivatives in forensic field.

Pentafluorophenylprophyl Ligand-based Liquid Chromatography-Tandem Mass Spectrometric Method for Rapid and Reproducible Determination of Metformin in Human Plasma

  • Yang, Jeong Soo;Oh, Hyeon Ju;Jung, Jin Ah;Kim, Jung-Ryul;Kim, Tae-Eun;Ko, Jae-Wook;Lee, Soo-Youn;Huh, Wooseong
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권11호
    • /
    • pp.3284-3288
    • /
    • 2013
  • This paper describes first development and validation of pentafluorophenylprophyl ligand-based liquid chromatography coupled to tandem mass spectrometry (PFPLC-MS/MS) method to determine metformin, a highly polar compound, in human plasma. Metformin and Phenformin (internal standard) were extracted from human plasma 50 ${\mu}L$ with a single-step protein precipitation. The chromatographic separation was performed using a linear gradient elution of mobile phase involving 5.0 mM ammonium formate solution with 0.1% formic acid (A) and acetonitrile (B) over 3.0 min of run time on a Phenomenex Luna PFP column. The detection was performed using a triple-quadrupole tandem mass spectrometer (Waters Quattro micro) with electrospray ionization in the mode of positive ionization and multiple-reaction monitoring (MRM). The developed method was validated with 5.0 ng/mL of lower limit of quantification (LLOQ). The calibration curve was linear over 5-3000 ng/mL of the concentration range ($R^2$ > 0.99). The specificity, selectivity, carry-over effect, precision, accuracy and stability of the method met the acceptance criteria. The method developed in this study had had rapidness, simplicity and ruggedness. The reliable method was successfully applied to high throughput analysis of real samples for a practical purpose of a pharmacokinetic study.

Collisional Activation Dissociation Mass Spectrometry Studies of Oligosaccharides Conjugated with Na+-Encapsulated Dibenzo-18-Crown-6 Ether

  • Bae, Jungeun;Song, Hwangbo;Moon, Bongjin;Oh, Han Bin
    • Mass Spectrometry Letters
    • /
    • 제7권4호
    • /
    • pp.96-101
    • /
    • 2016
  • To determine the influence of the cationization agent on the collision activated dissociation (CAD) fragmentation behavior of oligosaccharides, the CAD spectra of the singly protonated, sodiated oligosaccharides and singly sodiated and dibenzo-18-crown-6 ether conjugated oligosaccharides were carefully compared. Each of these three different species showed quite different fragmentation spectra. The comparison of singly protonated and sodiated oligosaccharide CAD spectra revealed that different cationization agents affected the cationization agent adduction sites as well as the fragmentation sites within the oligosaccharides. When the mobility of $Na^+$ was limited by the dibenzo-18-crown-6 ether encapsulation agent, the examined linear oligosaccharides showed fragmentation patterns quite different from the unmodified ones. For the dibenzo-18-crown-6 ether conjugated oligosaccharides, the charge-remote fragmentation pathways were more likely to be activated than the chargedirected pathways. This work demonstrates that dibenzo-18-crown-6 ether conjugation can potentially provide a route to selectively activate the charge-remote fragmentation pathways, albeit to a limited extent, in tandem mass spectrometry studies.

Gas Chromatography-High Resolution Tandem Mass Spectrometry Using a GC-APPI-LIT Orbitrap for Complex Volatile Compounds Analysis

  • Lee, Young-Jin;Smith, Erica A.;Jun, Ji-Hyun
    • Mass Spectrometry Letters
    • /
    • 제3권2호
    • /
    • pp.29-38
    • /
    • 2012
  • A new approach of volatile compounds analysis is proposed using a linear ion trap Orbitrap mass spectrometer coupled with gas chromatography through an atmospheric pressure photoionization interface. In the proposed GC-HRMS/MS approach, direct chemical composition analysis is made for the precursor ions in high resolution MS spectra and the structural identifications were made through the database search of high quality MS/MS spectra. Successful analysis of a complex perfume sample was demonstrated and compared with GC-EI-Q and GC-EI-TOF. The current approach is complementary to conventional GC-EI-MS analysis and can identify low abundance co-eluting compounds. Toluene co-sprayed as a dopant through API probe significantly enhanced ionization of certain compounds and reduced oxidation during the ionization.