• Title/Summary/Keyword: TanDEM-X

Search Result 13, Processing Time 0.114 seconds

Mangrove Height Estimates from TanDEM-X Data (TanDEM-X 자료를 활용한 망그로브 식생 높이 측정)

  • Lee, Seung-Kuk
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_2
    • /
    • pp.325-335
    • /
    • 2020
  • Forest canopy height can be used for estimate of above-ground forest biomass (AGB) by means of the allometric equation. The remote locations and harsh conditions of mangrove forests limit the number of field inventory data stations needed for large-scale modeling of carbon and biomass dynamics. Although active and passive spaceborne sensors have proven successful in mapping mangroves globally, the sensors generally have coarse spatial resolution and overlook small-scale features. Here we generate a 12 m spatial resolution mangrove canopy height map from TanDEM-X data acquired over the world largest intact mangrove forest located in the Sundarbans. With single-pol. TanDEM-X data from 2011 to 2013, the proposed technique makes use of the fact that the double-bounce scattering that occurs between the water and mangrove trees yields water surface level elevation over mangrove forest areas, thus allowing us to estimate forest height with the assumption of an underlying flat topography. Our observations have led to a large-scale mangrove canopy height map over the entire Sundarbans region at a 12 m spatial resolution. Our canopy height estimates were validated with ground measurements acquired in 2015, a correlation coefficient of 0.83 and a RMSE of 0.84 m. With globally available TanDEM-X data, the technique described here will potentially provide accurate global maps of mangrove canopy height at 12 m spatial resolution and provide crucial information for understanding biomass and carbon dynamics in the mangrove ecosystems.

Improvement of 2-pass DInSAR-based DEM Generation Method from TanDEM-X bistatic SAR Images (TanDEM-X bistatic SAR 영상의 2-pass 위성영상레이더 차분간섭기법 기반 수치표고모델 생성 방법 개선)

  • Chae, Sung-Ho
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_1
    • /
    • pp.847-860
    • /
    • 2020
  • The 2-pass DInSAR (Differential Interferometric SAR) processing steps for DEM generation consist of the co-registration of SAR image pair, interferogram generation, phase unwrapping, calculation of DEM errors, and geocoding, etc. It requires complicated steps, and the accuracy of data processing at each step affects the performance of the finally generated DEM. In this study, we developed an improved method for enhancing the performance of the DEM generation method based on the 2-pass DInSAR technique of TanDEM-X bistatic SAR images was developed. The developed DEM generation method is a method that can significantly reduce both the DEM error in the unwrapped phase image and that may occur during geocoding step. The performance analysis of the developed algorithm was performed by comparing the vertical accuracy (Root Mean Square Error, RMSE) between the existing method and the newly proposed method using the ground control point (GCP) generated from GPS survey. The vertical accuracy of the DInSAR-based DEM generated without correction for the unwrapped phase error and geocoding error is 39.617 m. However, the vertical accuracy of the DEM generated through the proposed method is 2.346 m. It was confirmed that the DEM accuracy was improved through the proposed correction method. Through the proposed 2-pass DInSAR-based DEM generation method, the SRTM DEM error observed by DInSAR was compensated for the SRTM 30 m DEM (vertical accuracy 5.567 m) used as a reference. Through this, it was possible to finally create a DEM with improved spatial resolution of about 5 times and vertical accuracy of about 2.4 times. In addition, the spatial resolution of the DEM generated through the proposed method was matched with the SRTM 30 m DEM and the TanDEM-X 90m DEM, and the vertical accuracy was compared. As a result, it was confirmed that the vertical accuracy was improved by about 1.7 and 1.6 times, respectively, and more accurate DEM generation was possible with the proposed method. If the method derived in this study is used to continuously update the DEM for regions with frequent morphological changes, it will be possible to update the DEM effectively in a short time at low cost.

Precise Topographic Change Study Using Multi-Platform Remote Sensing at Gomso Bay Tidal Flat (다중 원격탐사 플랫폼 기반 곰소만 갯벌 정밀 지형변화 연구)

  • Hwang, Deuk Jae;Kim, Bum-Jun;Choi, Jong-Kuk;Ryu, Joo Hyung
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_2
    • /
    • pp.263-275
    • /
    • 2020
  • In this study, DEMs (Digital elevation model) based on LIDAR, TanDEM-X and UAV (Unmanned Aerial Vehicle) are used to analyze topographic change of Gomso tidal flat during a few years. DEM from LIDAR data was observed at 2011 by KHOA (Korean hydrographic and oceanographic agency) and DEM based on TanDEM-X data was generated at Lee and Ryu (2017). UAV data was observed at KM and KH area of Gomso tidal flat. KM area was surveyed at MAY and AUG 2019, and KH area was surveyed at APR 2018 and MAY 2019. During research period, 2011 to AUG 2019, elevation of KM area is decreased 0.24 m in average, and Chenier is retreat to landward about 130 m. In KH area, elevation is increased 0.16 m in average during research period, 2011 to MAY 2019. It is expected that multi-platform remotely sensed data can help to study accurate topographic change of tidal flat.

Grounding Line of Campbell Glacier in Ross Sea Derived from High-Resolution Digital Elevation Model (고해상도 DEM을 활용한 로스해 Campbell 빙하의 지반접지선 추정)

  • Kim, Seung Hee;Kim, Duk-jin;Kim, Hyun-Cheol
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.545-552
    • /
    • 2018
  • Grounding line is used as evidence of the mass balance showing the vulnerability of Antarctic glaciers and ice shelves. In this research, we utilized a high resolution digital elevation model of glacier surface derived by recently launched satellites to estimate the position of grounding line of Campbell Glacier in East Antarctica. TanDEM-X and TerraSAR-X data in single-pass interferometry mode were acquired on June 21, 2013 and September 10, 2016 and CryoSat-2 radar altimeter data were acquired within 15 days from the acquisition date of TanDEM-X. The datasets were combined to generate a high resolution digital elevation model which was used to estimate the grounding line position. During the 3 years of observation, there weren't any significant changes in grounding line position. Since the average density of ice used in estimating grounding line is not accurately known, the variations of the grounding line was analyzed with respect to the density of ice. There was a spatial difference from the grounding line estimated by DDInSAR whereas the estimated grounding line using the characteristics of the surface of the optical satellite images agreed well when the ice column density was about $880kg/m^3$. Although the reliability of the results depends on the vertical accuracy of the bathymetry in this study, the hydrostatic ice thickness has greater influence on the grounding line estimation.

Extraction and Analysis of Ganghwa Tidal Flat Channels Using TanDEM-X DEM (TanDEM-X DEM을 이용한 강화도 갯벌 조류로 추출과 분석)

  • Yun, Ga-Ram;Kim, Lyn;Kim, Nam-Yeong;Kim, Na-Gyeong;Jang, Yun-Yeong;Choi, Yeong-Jin;Lee, Seung-Kuk
    • The Journal of Engineering Geology
    • /
    • v.32 no.3
    • /
    • pp.411-420
    • /
    • 2022
  • Recently, research using remote sensing has been active in various fields such as environment, science, and society. The results of research using remote sensing are not only numerical results, but also play an important role in solving and preventing social and scientific problems. The purpose of this thesis is to tell the correlation between the data provided and each data by using remote sensing technology for the tidal flat environment. The purpose of this study is to obtain high-resolution data using artificial satellites during remote sensing to find out information on tidal flat currents. Tidal flats created by erosion, sedimentation, low tide, and high tide contain information about the tidal flat slope and information about the ecosystem. Therefore, it can be considered as one of the very important studies to analyze the overall tidal flow channel. This paper creates a DEM (Digital Elevation Model) through TanDEM-X, and DEM is used as the most basic data to create a tidal channel. The research area is a tidal flat located in the middle of the west coast of Ganghwado tidal flat. By analyzing the tidal channel created, various information such as the slope direction of Ganghwado tidal flat and the shape of the tidal channel can be grasped. It is expected that the results of this study will increase the importance and necessity of using DEM data for tidal flat research in the future, and that high-quality results can be obtained.

Investigation of Intertidal Zone using TerraSAR-X: A Preliminary Result (TerraSAR-X를 이용한 조간대 관측: 초기결과)

  • Park, Jeong-Won;Lee, Yoon-Kyung;Won, Joong-Sun
    • Proceedings of the KSRS Conference
    • /
    • 2009.03a
    • /
    • pp.46-52
    • /
    • 2009
  • TerraSAR-X 자료를 이용하여 고해상 X-밴드 SAR 시스템을 이용한 조간대 적용 가능성을 시험하였다 연구대상지역은 강화도 남단과 영종도를 잇는 조간대이며, 단일편파자료와 이중편파자료를 이용하였다. 연구내용은 다음과 같은 세 가지로 분류된다. 첫째, X-밴드 영상에서의 연안의 레이더 반사도 특성 연구 및 waterline 추출 정밀도를 평가하였다. 연안지역의 wateline은 HH 편광자료의 레이더 반사도 특성을 통하여 추출하였을 때 가장 신뢰도가 높았으며, TerraSAR-X 시스템의 짧은 파장과 높은 제도정밀도로 인하여 정밀한 지리좌표로의 변환이 가능하였다 연구지역의 조간대 지형 경사도는 평균적으로 수평방향으로 60m당 20cm의 고도변화를 가지므로, TerraSAR-X HH 편광자료를 이용한 waterline 추출은 정밀한 조간대 DEM 추출로 응용될 수 있다. 둘째, 이중편파자료의 편파특성을 이용한 조간대 염생식물의 산란특성 관측하였다. 조간대에서 수륙의 경계부에서 잘 관측되는 칠면초와 같은 염생식물은 해수면변화에 따른 조간대의 육지화를 모니터링 하는데 좋은 표적이 된다. TerraSAR-X 이중편파자료의 산란특성을 이용한 염생식물 관측결과는 2007년에 현장에서 취득된 실측자료와 비교하여 3dB 이내의 정밀도로 일치하였다 셋째, 단일편파 자료의 레이더 간섭기법을 이용한 조간대 DEM 작성 시도하였다. 조간대 내에서 육지화가 진행된 지역은 표면에 염생식물이 발달하였음에도 불구하고 높은 간섭긴밀도를 나타내었다. 레이더 간섭기법을 통한 DEM의 제작은 일반적인 조간대에서는 적용이 제한적이며, TanDEN-X의 적용이 필요하다.

  • PDF

The Contents of SatDSiG and Its Implications for Korea (독일 위성자료보안법의 내용 및 시사점)

  • JUNG, Yungjin
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.2
    • /
    • pp.60-65
    • /
    • 2019
  • TerraSAR-X, launched in June 2007, and TanDEM-X, June 2010, are remote-sensing satellites with 1M resolution that are capable of observing the ground even during the nighttime and poor weather conditions. The two satellites had been developed under a public-private partnership between the German Aerospace Centre and Airbus in the interest of the commercial marketing for German satellite data. However, the data of high-grade earth remote-sensing system, such as those of the satellites, has been produced by a military satellite and thus used under limited circumstances in Germany. Therefore, a legislation to commercialize the German satellite data and to protect its national security is needed. For this, SatDSiG was enacted in December 2007. Thus this article will contain the main contents of SatDSiG and its implication for Korea, which stared to export data of Kompsat 3, 3A and 5 in 2018.

Investigation of Intertidal Zone using TerraSAR-X (TerraSAR-X를 이용한 조간대 관측)

  • Park, Jeong-Won;Lee, Yoon-Kyung;Won, Joong-Sun
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.4
    • /
    • pp.383-389
    • /
    • 2009
  • The main objective of the research is a feasibility study on the intertidal zone using a X-band radar satellite, TerraSAR-X. The TerraSAR-X data have been acquired in the west coast of Korea where large tidal flats, Ganghwa and Yeongjong tidal flats, are developed. Investigations include: 1) waterline and backscattering characteristics of the high resolution X-band images in tidal flats; 2) polarimetric signature of halophytes (or salt marsh plants), specifically Suaeda japonica; and 3) phase and coherence of interferometric pairs. Waterlines from TerraSAR-X data satisfy the requirement of horizontal accuracy of 60 m that corresponds to 20 cm in average height difference while current other spaceborne SAR systems could not meet the requirement. HH-polarization was the best for extraction of waterline, and its geometric position is reliable due to the short wavelength and accurate orbit control of the TerraSAR-X. A halophyte or salt marsh plant, Suaeda japonica, is an indicator of local sea level change. From X-band ground radar measurements, a dual polarization of VV/VH-pol. is anticipated to be the best for detection of the plant with about 9 dB difference at 35 degree incidence angle. However, TerraSAR-X HH/TV dual polarization was turned to be more effective for salt marsh monitoring. The HH-HV value was the maximum of about 7.9 dB at 31.6 degree incidence angle, which is fairly consistent with the results of X-band ground radar measurement. The boundary of salt marsh is effectively traceable specifically by TerraSAR-X cross-polarization data. While interferometric phase is not coherent within normal tidal flat, areas of salt marsh where the landization is preceded show coherent interferometric phases regardless of seasons or tide conditions. Although TerraSAR-X interferometry may not be effective to directly measure height or changes in tidal flat surface, TanDEM-X or other future X-band SAR tandem missions within one-day interval would be useful for mapping tidal flat topography.

A Study on Automated Lineament Extraction with Respect to Spatial Resolution of Digital Elevation Model (수치표고모형 공간해상도에 따른 선구조 자동 추출 연구)

  • Park, Seo-Woo;Kim, Geon-Il;Shin, Jin-Ho;Hong, Sang-Hoon
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.439-450
    • /
    • 2018
  • The lineament is a linear or curved terrain element to discriminate adjacent geological structures in each other. It has been widely used for analysis of geology, mineral exploration, natural disasters, and earthquake, etc. In the past, the lineament has been extracted using cartographic map or field survey. However, it is possible to extract more efficiently the lineament for a very wide area thanks to development of remote sensing technique. Remotely sensed observation by aircraft, satellite, or digital elevation model (DEM) has been used for visual recognition for manual lineament extraction. Automatic approaches using computer science have been proposed to extract lineament more objectively. In this study, we evaluate the characteristics of lineament which is automatically extracted with respect to difference of spatial resolution of DEM. We utilized two types of DEM: one is Shuttle Radar Topography Mission (SRTM) with spatial resolution of about 90 m (3 arc sec), and the other is the latest world DEM of TerraSAR-X add-on for Global DEM with 12 m spatial resolution. In addition, a global DEM was resampled to produce a DEM with a spatial resolution of 30 m (1 arc sec). The shaded relief map was constructed considering various sun elevation and solar azimuth angle. In order to extract lineament automatically, we used the LINE module in PCI Geomatica software. We found that predominant direction of the extracted lineament is about $N15-25^{\circ}E$ (NNE), regardless of spatial resolution of DEM. However, more fine and detailed lineament were extracted using higher spatial resolution of DEM. The result shows that the lineament density is proportional to the spatial resolution of DEM. Thus, the DEM with appropriate spatial resolution should be selected according to the purpose of the study.

Persistent Scatterer Selection and Network Analysis for X-band PSInSAR (X-band PSInSAR를 위한 고정산란체 추출 및 네트워크 분석 기법)

  • Kim, Sang-Wan;Cho, Min-Ji
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.5
    • /
    • pp.521-534
    • /
    • 2011
  • The high-resolution X-band SAR systems such as COSMO-SkyMED and TerraSAR-X have been launched recently. In addition KOMPSAT-5 will be launched in the early of 2012. In this study we developed the new method for persistent scatterer candidate (PSC) selection and network construction, which is more suitable for PSInSAR analysis using multi-temporal X-band SAR data. PSC selection consists in two main steps: first, selection of initial PSCs based on amplitude dispersion index, mean amplitude, mean coherence. second, selection of final PSCs based on temporal coherence directly estimated from network analysis of initial PSCs. To increase the stability of network the Multi- TIN and complex network for non-urban area were addressed as well. The proposed algorithm was applied to twenty-one TerraSAR-X SAR of New Orleans. As a result many PSs were successfully extracted even in non-urban area. This research can be used as the practical application of KOMPSAT-5 for surface displacement monitoring using X-band PSInSAR.