• 제목/요약/키워드: Table height

검색결과 290건 처리시간 0.022초

Table Detection from Document Image using Vertical Arrangement of Text Blocks

  • Tran, Dieu Ni;Tran, Tuan Anh;Oh, Aran;Kim, Soo Hyung;Na, In Seop
    • International Journal of Contents
    • /
    • 제11권4호
    • /
    • pp.77-85
    • /
    • 2015
  • Table detection is a challenging problem and plays an important role in document layout analysis. In this paper, we propose an effective method to identify the table region from document images. First, the regions of interest (ROIs) are recognized as the table candidates. In each ROI, we locate text components and extract text blocks. After that, we check all text blocks to determine if they are arranged horizontally or vertically and compare the height of each text block with the average height. If the text blocks satisfy a series of rules, the ROI is regarded as a table. Experiments on the ICDAR 2013 dataset show that the results obtained are very encouraging. This proves the effectiveness and superiority of our proposed method.

CT 테이블 높이에 따른 방사선 선량 및 화질 평가 (Evaluation of Radiation Dose and Image Quality according to CT Table Height)

  • 이종웅;정홍문
    • 한국방사선학회논문지
    • /
    • 제11권6호
    • /
    • pp.453-458
    • /
    • 2017
  • 컴퓨터단층촬영 (CT:Computed Tomography)은 환자의 정확한 진단을 위해 진단참고준위인 전산화 단층촬영 선량지표 (CTDI: Computed Tomography Dose Index)와 (DLP:Dose Length Product)의 정보를 제공한다. 그러나 CT 장비가 제공하는 진단참고준위는 테이블 높이에 따른 선량의 변화를 제공하지 않는다. 이번 연구는 컴퓨터단층촬영 검사 시 최적화된 이미지와 최소선량을 찾기 위하여 컴퓨터단층촬영 테이블 높이 변화에 따른 이미지와 선량을 팬텀(PMMA: Polymethyl Methacrylate)을 사용하여 비교 평가하였다. 성인의 복부와 같은 두께인 32 cm PMMA 팬텀을 촬영할 경우 테이블 높이에 따른 선량 변화는 거의 없었다. 그러나 이미지의 노이즈(Noise) 평가에서는 테이블 높이에 따라 노이즈 변동 폭이 크게 발생되었다. 그리고 16 cm PMMA 팬텀인 경우는 노이즈의 변화는 작지만 선량변화는 약 30 % 발생하였다. 결론적으로 컴퓨터단층촬영 (CT:Computed Tomography)의 검사 시에는 환자의 두께에 중심에 정확하게 일치시켜야 한다. 또한 최적화된 이미지와 최소선량으로 검사하기 위해서는 테이블 높이 설정이 중요할 것으로 사료된다.

현행(現行) 이변수재적표(二變數材積表)의 적합성(適合性)에 대(對)하여 (On the Suitability of the volume table based upon D.B.H. and Height now in use)

  • 김동춘
    • 한국산림과학회지
    • /
    • 제5권1호
    • /
    • pp.1-3
    • /
    • 1966
  • According to the test of suitability on the acting volume table based upon D.B.H. and Height, the volume by the standing volume table of soft woods produced in Kangwon Province is larger than the true volume and the volume by the standing volume table prepared in form factor 0.45 is smaller than the true volume on the all species obviously. But the volume by the standing volume table of the red pine produced in Kangwon Province and that of Korean white pine prepared in Forest Expriment Station equal to the true volume well.

  • PDF

피보험체계측치(被保險體計測値)의 평가(評價)에 관한 연구(硏究) 제1보(第1報) 체격(體格) (A Study on the Rating of the Insureds' Anthropometric Data I. Build)

  • 임영훈
    • 보험의학회지
    • /
    • 제3권1호
    • /
    • pp.103-141
    • /
    • 1986
  • The present study was undertaken to establish the decision standard of builds for the insured by using the ratio of weight-for-height as build index. Materials being examined were the ratio of weight-for-height being calculated from the actually measured heights and weights of a total of 15,838 insured persons who were examined medically at Honam Medical Department of Dong Bang Life Insurance Company, Ltd. from June, 1979 to September, 1985. The ratio of weight-for-height is calculated by the following formula. The ratio of weight-for-height(%)=$\frac{weight(kg){\times}100}{\{height(cm)-100\}{\times}0.9(kg)$ The results were as follows: 1. The distribution of the ratio of weight. for-height of the 15,838 insureds follows Log normal distribution being skewed to the left(the direction of underweight). 2. The ratio of weight-for-height were Log transformed to lead to a sym metrical pattern of distribution in which statistical rules are known to be applied more exactly. Thereafter, the establishment of dicision standard of builds was undertaken by using the log of the ratio of weight-for-height as build index. Through all ages in male, the ratio of weight-for-height indicating the range of standard lives including slight overweighted and underweighted lives besides normal lives is 80-130%, and corresponds to $"M-2{\delta}"-"M+1.5{\delta}"$ and to $M{\pm}20%$ ; in female, 85-135%, and corresponds to $"M-2{\delta}"-"M+1.5{\delta}"$ and to $M{\pm}20%$. Through all ages in male, the ratio of weight-for-height indicating the initial level of super-overweighted and super-underweighted lives is 130-150% and 75-80%,and corresponds to $M+3{\delta}\;and\;M-3{\delta}$ and to M+40% and M-25% respectively;in female, 140-160% and 75-80%, and corresponds to $M+3{\delta}\;and\;M-3{\delta}$ and to M+40%-+50% and M-25% respectively. 3. Author's rating table model for builds(a table of weight per height) is proposed. On the table, the ratings for builds, i. e. standard, super-weighted and super-underweighted lives, are listed.

  • PDF

Reduction of Radiation Dose to Eye Lens in Cerebral 3D Rotational Angiography Using Head Off-Centering by Table Height Adjustment: A Prospective Study

  • Jae-Chan Ryu;Jong-Tae Yoon;Byung Jun Kim;Mi Hyeon Kim;Eun Ji Moon;Pae Sun Suh;Yun Hwa Roh;Hye Hyeon Moon;Boseong Kwon;Deok Hee Lee;Yunsun Song
    • Korean Journal of Radiology
    • /
    • 제24권7호
    • /
    • pp.681-689
    • /
    • 2023
  • Objective: Three-dimensional rotational angiography (3D-RA) is increasingly used for the evaluation of intracranial aneurysms (IAs); however, radiation exposure to the lens is a concern. We investigated the effect of head off-centering by adjusting table height on the lens dose during 3D-RA and its feasibility in patient examination. Materials and Methods: The effect of head off-centering during 3D-RA on the lens radiation dose at various table heights was investigated using a RANDO head phantom (Alderson Research Labs). We prospectively enrolled 20 patients (58.0 ± 9.4 years) with IAs who were scheduled to undergo bilateral 3D-RA. In all patients' 3D-RA, the lens dose-reduction protocol involving elevation of the examination table was applied to one internal carotid artery, and the conventional protocol was applied to the other. The lens dose was measured using photoluminescent glass dosimeters (GD-352M, AGC Techno Glass Co., LTD), and radiation dose metrics were compared between the two protocols. Image quality was quantitatively analyzed using source images for image noise, signal-to-noise ratio, and contrast-to-noise ratio. Additionally, three reviewers qualitatively assessed the image quality using a five-point Likert scale. Results: The phantom study showed that the lens dose was reduced by an average of 38% per 1 cm increase in table height. In the patient study, the dose-reduction protocol (elevating the table height by an average of 2.3 cm) led to an 83% reduction in the median dose from 4.65 mGy to 0.79 mGy (P < 0.001). There were no significant differences between dose-reduction and conventional protocols in the kerma area product (7.34 vs. 7.40 Gy·cm2, P = 0.892), air kerma (75.7 vs. 75.1 mGy, P = 0.872), and image quality. Conclusion: The lens radiation dose was significantly affected by table height adjustment during 3D-RA. Intentional head off-centering by elevation of the table is a simple and effective way to reduce the lens dose in clinical practice.

랜지후드의 설치 높이에 따른 오염물질의 배출성능에 관한 연구 (A Study on the Exhaust Performance of Contaminant by Establishment Height of Hood)

  • 송필동;박명길;함진식
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2001년도 학술발표대회논문집
    • /
    • pp.99-104
    • /
    • 2001
  • This paper is contents that experiment exhaust performance of contaminant by establishment height gas table and hood establishment height. Hood made to control from gas table to 10 centimeters space from 30 centimeters to 70 centimeters. Exhaust fan operated by 110V, 160V, 220V, and gas used propane gas. Center part appeared highest as result that measure wind velocity and temperature from hood lower part. Wind velocity from hood lower part was proved that dominate contaminant exhaust performance. Exhaust performance of carbon dioxide and heat showed that 30 centimeters case overmatches because establishment height of hood compares 80 centimeters. Case of carbon dioxide of exhaust performance by establishment height of hood overmatched more than heat.

  • PDF

치과기공사의 체형에 적합한 작업대의 분석 (A analysis of Proper Workbench for Body Type of Dental Technician)

  • 한민수;최에스더;오선미
    • 한국산학기술학회논문지
    • /
    • 제14권1호
    • /
    • pp.328-335
    • /
    • 2013
  • 본 연구는 치과기공사의 체형에 적합한 인간공학적인 작업 자세를 위한 작업대의 높이를 연구하고 개선방안을 제시하는 것이 목적이다. 이를 위해 경기지역과 충청도에 소재한 대학의 치기공과 3학년 학생 77명을 대상으로 학생의 신장과 몸무게 및 신체치수를 측정하였고 임상실습 시 가장 힘들었던 작업 자세에 대해 조사하였다. 또한 이를 실제작업환경과 비교 분석을 위해 수도권에 위치한 종합병원 치과기공실 2곳과 치과기공소 15곳을 직접 방문하여 의자를 포함한 책상 및 작업대 높이를 측정하여 측정값을 통계학적으로 분석 하였다. 특히 가장 많은 불편을 초래하는 원인 인자에 대해 세부적인 분석을 하였으며 이러한 분석 자료를 검토한 결과 다음과 같은 결론을 얻었다. 임상실습 시 가장 불편을 느끼는 작업대는 샌드작업대의 높이로 조사되었고 3학년 학생들의 성별과 불편한 작업대의 선택 항목간과 상관관계는 없는 것으로 분석되었다. 또한 샌드작업대가 불편했던 원인은 권장수치보다 낮은 샌드작업대의 높이 때문인 것으로 추정하였으며, 3학년 학생에게 적합한 샌드작업대의 최적의 높이는 권장치보다 다소 높은 것으로 분석되었다. 샌드작업대의 최적의 높이는 치기공과 3학년 학생의 키에 따라 다소 편차가 있었으며 개수대의 높이는 권장안보다 낮은 것으로 분석되었다. 또한 일반적으로 제시되는 권장안은 기본적으로 모든 작업자의 상이한 신장에 균일하게 적용되지 않음을 알 수 있었다.

조간대 저토 환경과 갈대의 생장 특성 (Sediment Properties and Growth of Phragmites australis in Mud Tidal Flat)

  • 민병미
    • 한국환경복원기술학회지
    • /
    • 제14권3호
    • /
    • pp.57-69
    • /
    • 2011
  • This study examined the relationship between Phragmites australis' growth and sediment properties at mud tidal flat of Donggum-ri, Gilsang-myeon, Gangwha-gun, Incheon city. Field survey was carried out from May, 2010 to October, 2010. Water content, soil texture, electric conductivity and water table depth for sediment, density, height, dry weight and flowering for P. australis were examined at several plots from the starting point (the coastal embankment) to the end point of the two populations. The result was as follows. Firstly, the water table increased along distance from the embankment at one line (N-line) but was similar at the other line (S-line) in a P. asustralis population. Water tables were higher out of than within a P. australis population at two populations. Secondary, in N-line, the height and dry weight of P. australis decreased along the distance from embankment but, in S-line, those were similar in its population. P. australis' growth was dependent on electric conductivity at lower layer (water table level) rather than upper one (the surface). Thirdly, density of P. australis changed during growing season and was similar in a population, except for the end point of patch. In summary, the growth and distribution of P. australis were dependent on salt content of tidal flat's sediment (water table level) and this was affected by fresh water of the inland.

진동대시험을 이용한 콘크리트 표면 차수벽형 석괴댐의 내진성능 평가 (Evaluation of Resistance of Concrete-Face Rockfill Dam to Seismic Loading Using Shaking Table Test)

  • 하익수;김용성;서민우;박동순
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1118-1125
    • /
    • 2005
  • In this study, seismic safety of CFRD(Concrete-Face Rockfill Dam) type "D" dam in operation is evaluated from the results of 1-g shaking table test using similitude laws. Model dam is made by similitude law considering the grain size of prototype dam component. After the model dam is impounded to the normal water level(N.W.L), it is excited by artificial earthquake wave corresponding to standard design respond spectrum of the "D" dam site. Displacement response behavior of the dam is examined through the measurement of vertical and horizontal displacement of dam crest. Also, amplification characteristics of acceleration with dam height is examined through the measurement of acceleration with dam height. Finally, the purpose of this study is to evaluate seismic safety of "D" dam in operation. From the results of acceleration measurement, it was found that acceleration of dam crest was amplified about 1.52 times compared to the acceleration of dam bottom and amplification phenomenon is outstanding at three quarters of dam height from the bottom of dam. From the analysis of displacement behavior, it was estimated that vertical displacement of prototype dam is 6.8cm (0.1% of dam height) and horizontal displacement 12.3cm(0.2% of dam height). These percentages is much lower than 1% of dam height(general stability criteria). Therefore, it was concluded that seismic stability of "D" dam against an estimated earthquake is guaranteed.

  • PDF

경추 고정 마네킹에게 직접 후두경(Macintosh laryngoscope), 부지(Gum elastic bougie), 비디오 후두경(Pentax AirWay Scope)을 사용한 기관내삽관 비교 (A Comparison of Endotracheal Intubation using the Macintosh Laryngoscope, the Gum Elastic Bougie and the Pentax AirWay Scope in Neck-Stabilized Manikin)

  • 최욱진;조근자
    • 한국응급구조학회지
    • /
    • 제15권3호
    • /
    • pp.71-80
    • /
    • 2011
  • Purpose : This research was designed to provide basic data for advanced pre-hospital airway management by comparing the ease of intubation, the success rate and the time for intubation performed with Macintosh Laryngoscope, Gum Elastic Bougie and Pentax AirWay Scope on the floor and table. Methods : Intubation was performed 30 times in total, including 5 times for each of intubation using Macintosh Laryngoscope, Gum Elastic Bougie and Pentax Airway Scope on the table and floor, only on subjects who passed the practice test of the national exam for paramedics. Data were collected by measuring the ease of intubation, the success rate and the time for intubation, and then analyzed by descriptive analysis, paired t-test, ANOVA using SPSS 18.0. Results : 1. There was a significant difference in the ease of intubation according to intubation devices. 2. There was a significant difference in the ease of intubation according to table height for intubation. 3. There was a significant difference in the success rate according to intubation devices. 4. There was no significant difference in the success rate according to table height for intubation. 5. There was a significant difference in the intubation time according to intubation devices. 6. There was a partially significant difference in the intubation time according to table height for intubation. Conclusion : Sufficient training not only with Macintosh Laryngoscope but also with Gum Elastic Bougie and Pentax Airway Scope could improve the survival rate by intubation in patients with difficult airway.