• Title/Summary/Keyword: TWA

Search Result 123, Processing Time 0.025 seconds

An Assessment of Notice Exposure by Job and Dosimeter Parameters Setting in Automobile Press Factory (자동차 프레스 공정에 있어서 직무 및 누적소음기 설정치 차이에 따른 작업자의 소음노출 평가)

  • Jeong, Jee Yeon;Park, Seunghyun;Yi, GwangYong;Lee, Naroo;You, Ki Ho;Park, Junsun;Chung, Ho Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.190-197
    • /
    • 2001
  • Noise-induced hearing loss(NIHL) was the highest rate (43.5%~58.5% from 1996 to 1998) of positive findings through specific medical program in Korea. There were much more NIHL at workers of automobile manufacturing factories than other manufacturing factories. The specific aim of the present study was to determine the noise exposure of automobile press lines, according to their job titles, press line types(auto, semiauto), dosimeter parameters setting. There were a total 11 press lines sampled at a automobile manufacturing company. Among those press lines, 10 press lines were autolines with acoustic enclosure, one semiauto press line was no aucostic enclosure Noise exposure data were sampled for an work shift using noise dosimeter, which recorded both time-weighted average(TWA) and 1-min average. The mean OSHA TWA(Korea TWA with threshold 90) was $80.7dB(A){\pm}4.7dB(A)$ for leader, $82.8dB(A{\pm}4.5dB(A)$ for pallette man, $76.7dB(A){\pm}4.3dB(A)$ for press operators, $76.6dB(A){\pm}5.6dB(A)$ for crane operators, $77.1dB(A){\pm}2.8dB(A)$ for forklift drivers, whereas the mean NIOSH TWA was $88.9dB(A){\pm}1.7dB(A)$ for leader, $89.6dB(A){\pm}2.1dB(A)$ for pallette man, $86.7dB(A){\pm}1.8dB(A)$ for press operators, $88.5dB(A){\pm}2.0dB(A)$ for crane operators, $87.7dB(A){\pm}1.0dB(A)$ for forklift drivers. While L10 for NIOSH TWA samples was 84.8 dB(A) ~ 87.3 dB(A), L10 for OSHA TWA samples was 69.5 dB(A) ~ 77.4 dB(A). L10 means that the TWA for 90% of the samples exceeded L10. Among OSHA TWA(Korea TWA with threshold 90) samples for pallette man, 7.7 % exceeded 90 dB(A), the OSHA permissible exposure level, but OSHA TWA samples for the other job titles didn't. Among NIOSH TWA samples, the samples over 85 dB(A), the NIOSH recommended exposure limit, was 100% (leaders), 83.3 %(operators), 97.4%(palletteman), 100%(forklift drivers), 91.7 %(crane operator). The results of One-way random effects analysis of variance models shows that the difference between job titles was significant by OSHA TWA(p<0.05), but not significant by NIOSH TWA(p>0.05). NIOSH TWA samples were significantly higher than OSHA TWA samples(P<0.05). Regression analysis was used to obtain relationships between OSHA TWA samples and NIOSH TWA samples. In this case the coefficient of determination = 0.90, which shows the high degree association between two methods. Regression equation, NIOSH TWA = 0.552 * OSHA TWA + 42.13 dB(A), shows that if OSHA TWA is known, NIOSH TWA can be predicted by the equation. The mean TWA difference between threshold 80 dBA and 90 dBA was significant(p<0.01). While the TWA noise exposures were 7.7% above the Korea(OSHA) PEL, they were more than 83.3% over NIOSH REL. Automobile workers were exposed to noise level that could be potentially damaging to their hearing. It found that there is approximately 25% excess risk of hearing loss even if a worker is protected to the PEL in according to NIOSH study.

  • PDF

A New TWA-Based Efficient Signal Integrity Verification Technique for Complicated Multi-Layer RLC Interconnect Lines (복잡한 다층 RLC 배선구조에서의 TWA를 기반으로 한 효율적인 시그널 인테그러티 검증)

  • Jo Chan-Min;Eo Yung-Seon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.7 s.349
    • /
    • pp.20-28
    • /
    • 2006
  • A new TWA(Traveling-wave-based Waveform Approximation)-based signal integrity verification method for practical interconnect layout structures which are composed of non-uniform RLC lines with various discontinuities is presented. Transforming the non-uniform lines into virtual uniform lines, signal integrity of the practical layout structures can be very efficiently estimated by using the TWA-technique. It is shown that the proposed technique can estimate the signal integrity much more efficiently than generic SPICE circuit model with 5% timing error and 10% crosstalk error.

The Current Work Environment Monitoring Status and Concentration Level of Substances with Short-Term Exposure Limits among Special Management Substances (특별관리물질 중 단시간노출기준 설정 물질의 작업환경측정 현황 및 농도 수준)

  • Hyunhee Park;Jihoon Jo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.3
    • /
    • pp.262-278
    • /
    • 2024
  • Objectives: To investigate the work environment measurement (WEM) status and concentration levels of substances with short-term exposure limits (STEL) among special management substances. Methods: Data from the past 5 years of WEM for 6 substances (1,2-dichloropropane (1,2-DCP), 1,3-butadiene, benzene, trichloroethylene (TCE), perchloroethylene (PCE) and sulfuric acid) were analyzed. The number of samples and concentration level of STEL and 8-hour TWA (time weighted average) were compared. Results: The number of STEL measurement for 1,3-butadiene, benzene, and sulfuric acid was less than 1% of the number of TWA measurement samples, while TCE, 1,2-DCP, and PCE, which are mainly used for cleaning metals, were relatively high, at 16.1%, 5.6%, and 2.2%, respectively. When comparing the concentrations of STEL with TWA on the same STEL measured workers (STEL-matched TWA), STEL concentrations were 2.8, 3.1, 2.6, 2.6 and 40.5 times higher than TWA as 1,2-DCP, benzene, TCE, PCE, and sulfuric acid. When comparing the concentration of STEL-matched TWA with the total TWA, STEL-matched TWA was 3.4, 8, 1.4, 2.0, 8.6 and 0.7 times higher for 1,2-DCP, benzene, 1,3-butadiene, TCE, PCE, and sulfuric acid, respectively. Conclusions: This study found that the workers performing irregular tasks may be exposed to higher concentrations of hazardous substances than regular workers. It is necessary to strengthen short-term exposure measurement, even for substances which STEL have not been set.

Reengineering Template-Based Web Applications to Single Page AJAX Applications (단일 페이지 AJAX 애플리케이션을 위한 템플릿 기반 웹 애플리케이션 재공학 기법)

  • Oh, Jaewon;Choi, Hyeon Cheol;Lim, Seung Ho;Ahn, Woo Hyun
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.1 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • Web pages in a template-based web application (TWA) are automatically populated using a template shared by the pages with contents specific to the pages. So users can easily obtain information guided by a consistent structure of the template. Reduced duplicated code helps to increase the level of maintainability as well. However, TWA still has the interaction problem of classic web applications that each time a user clicks a hyperlink a new page is loaded, although a partial update of the page is desirable. This paper proposes a reengineering technique to transform the multi-page structure of legacy Java-based TWA to a single page one with partial page refresh. In this approach, hyperlinks in HTML code are refactored to AJAX-enabled event handlers to achieve the single page structure. In addition, JSP and Servlet code is transformed in order not to send data unnecessary for the partial update. The new single page consists of individual components that are updateable independently when interacting with a user. Therefore, our approach can improve interactivity and responsiveness towards a user while reducing CPU and network usage. The measurement of our technique applied to a typical TWA shows that our technique improves the response time of user requests over the TWA in the range from 1 to 87%.

TWA가 베르니케실어증 환자의 재청각화에 미치는 효과

  • 서인효;정필상;이상준
    • Proceedings of the KSLP Conference
    • /
    • 2003.11a
    • /
    • pp.148-148
    • /
    • 2003
  • 목적 : 베르니케실어증환자의 치료에 있어서 전통적 기법은 청각적 이해력을 높이기 위해 청각변별력을 직접적으로 치료한다. 그에 반해 Helm-estabrooks 등(1991)에 의해 개발된 TWA(Treatment for Wernicke's Aphasia)는 읽고 이해하기(reading comprehension), 구두읽기(oral reading), 따라 말하기(repetition)등의 과정을 통해 재청각화(reauditorization)를 유발하여 청각이해력(auditory comprehension)을 향상시키는 언어치료 프로그램이다. 본 연구자들은 TWA가 베르니케실어증을 가진 한국인의 재청각화에도 효과적인지를 알아보고자 하였다. (중략)

  • PDF

작업환경을 위한 TLV의 근거 - PERCHLOROMETHYL MERCAPTAN(l)

  • Kim, Chi-Nyeon
    • 월간산업보건
    • /
    • s.273
    • /
    • pp.40-43
    • /
    • 2011
  • Perchloromethyl mercaptan에 대한 직업적 노출기준으로 TLV-TWA 0.1 ppm(0.76 mg/$m^3$)으로 권고한다. TLV-TWA 0.1 ppm(0.76 mg/$m^3$) 은 눈과 코의 자극 그리고 불쾌한 냄새로 인한 불편함의 가능성을 최소화하는 수준이다. Perchloromethyl mercaptan에 대한 동물 노출 실험연구와 근로자들의 노출연구 자료는 매우 제한적이다. 사고로 확인되지 않은 농도에 근로자들이 노출된 경우, 발견된 증상과 징후는 눈, 목, 가슴에 심한 자극과 기침, 눈물, 호흡곤란, 메스꺼움, 구토, 빈맥, 청색증, 경련 그리고 폐부종에 의한 사망이다. Perchloromethyl mercaptan을 활용하는 생산설비에서 TLV-TWA 0.1 ppm 이하 농도의 증기에 노출되었을 때 질병을 유발하였다는 보고는 없었다. 피부흡수, 발암성 그리고 TLV-STEL을 권고하기 위한 유용한 자료는 충분하지 않다.

  • PDF

TCE Exposure Assessment of Cleaning Workers (세척공정의 트리클로로에틸렌 TWA 및 STEL 평가 사례)

  • Hyun Soo Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.1
    • /
    • pp.3-5
    • /
    • 2023
  • Objective: This study introduces exposure concentrations of time-weighted average standard (TWA) evaluation and short-time exposure standard (STEL) evaluation for trichloroethylene in the cleaning process. Methods: Trichloroethylene measurement was conducted according to the KOSHA Guide (A-24-2019) method. It was carried out twice. Results: As a result of the first measurement, TWA concentration exceeded 4 times the exposure standard and STEL concentration exceeded 16 times, but the inaccuracy and breakthrough of the collection time could not be considered, so the second measurement was conducted. The second measurement result was lower than the first measurement result, but exceeded the exposure standards (TWA, STEL). Conclusions: We were able to confirm that the exposure level of workers in the cleaning process using trichloroethylene exceeded the exposure standard. And it is also considered necessary to grasp the approximate concentration using a detector tube in the preliminary survey.

직업환경을 위한 TLV의 근거 - PHENOTHIAZINE

  • Kim, Chi-Nyeon
    • 월간산업보건
    • /
    • s.295
    • /
    • pp.11-14
    • /
    • 2012
  • Phenothiazine의 직업적 노출기준(TLV-TWA)은 $5mg/m^3$으로 권고되었다. TLV-TWA의 수준은 피부자극과 변색, 각막염 그리고 태양광에 직접 노출되었을 때 나타나는 광감작반응의 가능성을 최소화하기 위해 설정되었다. 고용량의 phenothiazine을 경구 투여하면 간과 신장이 손상되며 용혈성의 빈혈이 발생한다. Phenothiazine의 피부흡수에 의한 전신 독성이 증명되어 피부흡수 "Skin" 경고주석을 권고하였다. 감작제(SEN)와 발암성 경고주석 그리고 TLV-STEL을 설정하기에는 유용한 자료가 부족하다.

  • PDF

Design consideration for protecting fuel tank explosion (항공기 연료탱크 폭발 방지를 위한 설계 방안 연구)

  • Kim, Seung-kyem
    • Journal of Aerospace System Engineering
    • /
    • v.6 no.1
    • /
    • pp.7-12
    • /
    • 2012
  • Fuel tank design requires special care because tank explosion can cause catastrophic event with high possibility as shown in accident of TWA 800. In this study, cause of fuel tank explosion was reviewed and several design considerations to minimize explosion possibility were introduced.

A Study on Worker-Exposure to Formaldehyde in Some Histological Laboratories of Hospitals (일부 종합병원 조직검사실에서의 포름알데히드 노출에 관한 연구)

  • Park, Jiyoung;Zong, Moonshik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.1
    • /
    • pp.95-104
    • /
    • 1998
  • This Study was conducted at nine Histological Laboratories in the hospitals located in Seoul from August 20 to October 10, 1996. The main purpose of this study was to assess the TWA & STEL exposure to formaldehyde and to evaluate factors affecting formaldehyde concentration in Histological Laboratory. With evaluated factors, proper improvement strategy to minimize exposure was suggested. The results are summarized as follows ; 1. The TWA concentrations of the personal samples ranged from 0.02 to 3.86 ppm and that of one laboratory out of nine was exceeding 0.75 ppm, USA OSHA standard. The TWA concentrations of the area samples ranged from 0.08 ppm to 1.49 ppm and those of three laboratories out of nine were exceeding OSHA standard. 2. When measurement was conducted on the working tables. around Formaldehyde vessel, fixation container and storage cabinet, the geometric means of TWA concentrations were 0.62 ppm, 0.64 ppm. 0.58 ppm and 0.37 ppm respectively. 3. When overnight fixed specimens were examined, the STEL concentrations of personal samples ranged from 0.59 ppm to 5.01 ppm, those of three laboratories out of nine were exceeding 2 ppm, OSHA standard and the STEL concentrations of area samples ranged from 0.31 ppm to 3.08 ppm, those of four laboratories from nine were exceeding OSHA standard. 4. Factors affecting Formaldehyde exposure level were sanitation state of laboratory, volume of the room and opening state of fixation container & formaldehyde vessel(p<0.05).

  • PDF