소규모 다중이용시설의 실내공기질 실태조사 및 건강위해성평가: 민감군 이용시설을 중심으로 (Indoor Air Quality and Human Health Risk Assessment for Un-regulated Small-sized Sensitive Population Facilities)

  • 신혜진;박우상;김보경;지경희;김기태
    • 한국환경보건학회지
    • /
    • 제44권4호
    • /
    • pp.397-407
    • /
    • 2018
  • Objectives: The purpose of this study is to investigate human health risk assessment of indoor air pollutants at small-sized public-use facilities (e.g., daycare centers, hospital and elderly care facilities) that the susceptible population is mainly used. Methods: To assess indoor air quality (IAQ), the concentrations of indoor air contaminants such as HCHO, benzene, toluene, ethylbenzene, xylene, styrene, PM-10, CO, $NO_2$ and $O_3$ in air samples were measured according to the Indoor Air Quality Standard Method. By conducting the questionnaire survey, the major factors influencing IAQ were identified. Human health risk assessment was carried out in the consideration of type of use (user and worker) at 75 daycare centers, 34 hospitals and 40 elderly care facilities. Results: As a result of measurement of indoor air contaminants, the average concentration of HCHO and TVOCs in hospitals was higher than daycare centers and elderly care facilities, about 8.8 and 23.5% of hospitals were exceeded by IAQ standard. In human health risk assessment, for the user of daycare centers and elderly care facilities, the mean carcinogenic risk of HCHO inhalation was higher than acceptable value. Except for HCHO, other values were determined under acceptable risk. Similarly, for the worker of hospitals, the mean carcinogenic risk of HCHO inhalation was higher than acceptable value and other values were evaluated under acceptable risk. In contrast, the risk levels of other contaminants measured in elderly care facilities were acceptable. In the determination of factors influencing IAQ, the construction year, building type, ventilation time, and the use of air cleaner were identified. Conclusions: This study provides the information for establishing the plans of public health management of IAQ at small-sized public-use facilities that have not yet been placed under the regulation. The findings suggest the consideration of human health risk assessment results for the IAQ standards.

시험편 제작방법 변경에 따른 페인트, 퍼티의 TVOCs의 방출 특성 비교 (Comparison of TVOCs emission characterization of paint and putty according to the amendment of test specimen preparation method)

  • 박준만;유지호;김만구
    • 분석과학
    • /
    • 제23권2호
    • /
    • pp.109-118
    • /
    • 2010
  • 이 연구에서는 2008년에 개정된 "다중이용시설 등의 실내 공기 질 관리법"의 시행규칙 중에서 페인트와 퍼티의 시험방법과 개정된 시험방법을 비교하고 변경된 관리기준의 변화 방향에 대해서 알아보았다. 페인트의 경우 개정된 시험방법은 시험기간의 변경으로 인하여 원래 시험방법에 의한 방출강도 보다 약 45% 감소하였으며, 건조시간의 변화에 따른 방출강도의 영향은 없었다. 또한 도포량의 변화에 따른 방출강도의 변화는 $5\;mg/m^2h$ 이상의 높은 방출 강도를 가지는 제품은 방출강도의 변화가 크나 그 이외의 제품들에서는 방출강도의 변화가 없었다. 퍼티의 경우 개정된 시험방법은 시험기간의 변경으로 원래 시험방법에 의한 방출강도 보다 평균 61% 감소하였고, 건조시간의 변화에 따른 방출강도의 영향은 없었다. 그러나 퍼티의 도포량의 변화로 인하여 원 시험방법에 의한 방출강도보다 약 164% 증가 하였다. 개정된 시험방법에 따른 변경된 TVOCs의 관리기준은 페인트와 퍼티 모두 원래 시험방법에 의한 과거의 관리기준 보다 각각 1.8배 및 5.8배 완화된 것으로 나타났다.

학원시설 실내공기질과 이용자의 자각증상에 관한 연구 (The Association of Subjective Symptoms of Students and Indoor Air Quality in Private Academic Facilities)

  • 정경식;김남수;이종대;황보영;손부순;이병국
    • 한국환경보건학회지
    • /
    • 제35권6호
    • /
    • pp.468-477
    • /
    • 2009
  • To evaluate the current indoor air quality condition of private academic facilities in Korea and investigate its association with subjective symptoms of student residing at the same academic facilities, air quality monitoring was carried out in total of 20 academic facilities located in Seoul, Daejon and Chungnam from the beginning of January to the end of April, 2009. To assess the air quality condition of academic facilities, 6 air pollutants with temperature and humidity were measured simultaneously inside and outside of academic facilities. The rate of exceeding the Indoor Air Quality (IAQ) guideline concentrations in 6 air pollutants were 5%, 85%, 15%, 5%, 10% and 30% for CO, $CO_2$, PM10, HCHO, TVOCs and TBC, respectively. A questionnaire on 16 subjective symptoms related to indoor air quality was given to 342 students who studied at the 20 academic facilities. The most frequent symptom of students was 'I feel easily tired or sleepy', and this was followed by 'I feel muscular pain or stiffness on shoulder, back and neck'. The association of net difference (subjective symptoms at the academic facility - subjective symptoms of the usual situation) with air pollutants was analyzed using spearman rank correlation. In logistic analysis using proportional odds method, the students whose indoor air concentration of HCHO was ${\geq}60{\mu}g/m^3$ hadsignificant odds of having more subjective symptoms of 'My eyes are dry or feel irritated or itching' (OR=5.026: CI=1.587-15.911), 'I feel easily tired or sleepy' (OR=2.956: CI=1.072-8.152), 'I lose my concentration and I feel my memory is falling' (OR=7.745: CI=1.938-30.955) and 'I feel dizzy' (OR=4.424: CI=1.292-15.149) than those of <$60{\mu}g/m^3$.

건축용 바닥재로부터의 휘발성유기화합물 방출특성 (Emission Characteristics of Volatile Organic Compounds from Building Flooring Materials)

  • 윤중섭;이명화;엄석원;김민영;김종호;김신도
    • 대한환경공학회지
    • /
    • 제32권10호
    • /
    • pp.973-978
    • /
    • 2010
  • 에너지절감에 대한 인식이 높아짐에 따라 점차 건물이 밀폐화되고 있으며, 이로 인하여 실내공기질에 영향을 미치는 건축자재로부터의 휘발성유기화합물 방출에 대한 관심이 높아지고 있다. 그러므로 실내공기질을 개선하는데 있어 건축자재로부터의 VOCs 방출특성을 파악하는 것이 무엇보다 중요하다. 본 연구에서는 우리나라가 온돌문화인 점을 고려하여 대표적인 건축자재인 온돌마루와 접착제를 대상으로, 방출챔버시험을 통하여 온도 및 시간경과에 따른 헥산, 톨루엔 및 TVOCs 방출특성을 살펴보았다. VOCs의 방출속도는 온도와 비례관계를 나타내었으며, 바닥재에 존재하는 VOCs 발생원이 어느 위치에, 어떠한 형태로 존재하느냐가 시간의 경과에 따른 방출특성에 크게 영향을 미친다는 것을 알 수 있었다. 즉, 건축자재로부터의 헥산, 톨루엔의 방출은 전반적으로 초기에 방출속도가 높고 시간이 지남에 따라 점차 줄어드는 경향을 보이고 있으나, 온돌마루로부터의 톨루엔 방출은 다른 양상을 보이는데 시간이 지남에 따라 방출속도가 오히려 증가하여 6시간 경과 후 최대값을 보인 뒤 점차 감소하는 경향을 나타내었다. 이는 온돌마루에 함유되어 있는 톨루엔 발생원이 자재의 내부에 많이 존재하고 있기 때문에 시간이 경과함에 따라 방출속도가 증가했다가 다시 감소하는 경향을 보인 것으로 추정된다. 바닥재로부터의 VOCs 방출특성 실험결과를 종합하여 살펴보면, 온돌시스템에서 방출되는 고농도의 VOCs에 인체노출을 줄이기 위해서는 이사하기 전에 적어도 72시간 이상의 Bake-out 시간이 필요할 것이라 사료된다.

열탈착/저온농축-GC/MS에 의한 실내공기 중 휘발성 유기화합물 정량용 기체상 및 액체상 표준물질 첨가한 고체 흡착관의 비교 분석 (A comparative analysis of gas and liquid phase standard spiked solid sorbent tubes for the determination of volatile organic compounds in indoor air by TD-GC/MS)

  • 임현우;정성운;강철호;박진숙;박병무;최용욱
    • 분석과학
    • /
    • 제26권4호
    • /
    • pp.287-297
    • /
    • 2013
  • 본 연구는 고체 흡착관과 TD-GC/MS를 이용하여 7종의 휘발성 유기화합물에 대한 열탈착 분석조건을 최적화하였고, 기체상 및 액상 표준물질 첨가한 고체 흡착관을 사용하여 얻어진 검정곡선으로부터 휘발성 유기화합물을 비교 정량하였다. 대응표본 t-검정 결과, 스타일렌을 제외하고 벤젠, 톨루엔, 에틸벤젠, o-, m- 및 p-자일렌을 포함한 6종의 휘발성 유기화합물에 대해서는 액상 표준물질에 의한 표준 흡착관법이 기체상에 의해 제작된 표준 흡착관법이 유의수준 (${\alpha}=0.01$)에서 일치한 반면, 스타일렌에 대해서는 기체상 및 액체상으로 작성된 검정곡선에서 감응인자가 15.6% 차이가 발생하였는데 이것은 두방법 간에 유의한 차이가 있다는 것을 의미하였다. 따라서 BTEX를 포함한 스타일렌을 정량하는데 오차를 감소시키기 위해 액상 표준물질을 이용한 고체상 흡착관법을 사용하였다. 바로 그 점이 이 논문의 핵심내용임. 즉, 고가의 표준가스 대신에 저가의 액상 표준물질을 사용하여 정량하더라도 스타일렌 이외에 거의 동일한 값을 나타내기 때문임. 액체상 표준물법 조건에서 7종의 VOCs의 회수율은 $100{\pm}5%$, 재현성은 0.3~7.7%, 검출한계는 o-자일렌의 $0.01{\mu}g/m^3$에서부터 톨루엔의 $0.27{\mu}g/m^3$까지 범위를 나타내었다. 이러한 최적화된 분석방법을 신축 기숙사, 원룸 아파트 및 신차의 실내공기 중 휘발성 유기화합물을 정량하는데 적용하였다.

가습 주기에 따른 벽면형 식물바이오필터의 토양 수분 안정화 및 실내공기질 정화 (Stabilizing Soil Moisture and Indoor Air Quality Purification in a Wall-typed Botanical Biofiltration System Controlled by Humidifying Cycle)

  • 이창희;최봄;천만영
    • 원예과학기술지
    • /
    • 제33권4호
    • /
    • pp.605-617
    • /
    • 2015
  • 본 연구의 최종 목표는 실내의 공간과 식물바이오필터의 규모에 따라 실내공기 오염물질을 정화할 수 있는 식물 녹화와 자동관수 그리고 생물학적 여과 기능을 통합한 식물바이오필터 시스템의 개발이다. 본 연구는 가습 주기에 따른 벽면형(수직형) 식물바이오필터내 공기 흐름의 특성에 대한 안정성과 미세먼지 제거율을 비교하고, 이 식물바이오필터에 의한 휘발성 유기화합물의 제거율을 조사하기 위해 수행하였다. 본 실험에 사용된 식물바이오필터는 실내 공간 활용에 적합하도록 물펌프, 물탱크, 송풍기, 가습장치, 그리고 다층구조의 식물 식재 공간을 일체형으로 설계하였다. 실험 결과, 물펌프에 의해 작동하는 세 가지 다른 가습 주기 처리에 관계없이 식물바이오필터의 상대습도, 온도, 그리고 토양 수분 함량은 안정된 값을 나타내었다. 토양 수분 함량은 모든 가습 주기 처리에서 27.1-29.7%의 범위에서 안정적으로 유지하였으며, 특히 15분 작동 45분 작동 중지의 가습 주기를 120시간 동안 처리하여 $29.0{\pm}0.2%$의 평균 토양 수분 함량을 유지하면서 가장 수평적인 일차회귀식(y = 0.0008x + 29.09)을 보여주었다. 가습 주기에 따라 식물바이오필터를 통과한 미세먼지(PM10)와 초미세먼지(PM2.5) 입자 수에 대한 제거율(RE)은 각각 82.7-89.7%와 65.4-73.0% 범위에 있었고, PM10의 무게에 대한 RE는 58.1-78.9%의 범위에 있었다. 식물바이오필터를 통과한 자일렌, 에틸벤젠, 총 휘발성 유기화합물, 톨루엔의 RE는 71.3-75.5%의 범위에 있었으나, 벤젠과 포름알데히드의 RE는 각각 39.7%와 44.9%로 나타났다. 따라서 실내식물을 식재할 수 있는 본 벽면형 식물바이오필터는 실내 공기 정화에 매우 효과가 있는 것으로 확인하였다.