• 제목/요약/키워드: TV-CM

검색결과 90건 처리시간 0.027초

TVS법을 이용한 강유전체 박막내에서의 mobile charge밀도 산출 (Calculation of mobile charge density in ferroelectric films using TVS(Triangular Voltage)

  • 김용성;정순원;김채규;김진규;이남열;김광호;유병곤;이원재;유인규
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.433-436
    • /
    • 1999
  • In this paper we applied TVS(Triangular Voltage Sweep) method to calculate the mobile ionic charge densities in some ferroelectric thin films. During the measurement, the temperature of specimens were maintained at 20$0^{\circ}C$. By this method, the amount of mobile ionic charge Q$_{m}$ and mobile ionic charge density N$_{m}$ of a MFIS structure were calculated 3.5 [pC] and about 4.3$\times$10$^{11}$ [ions/cm$^2$], respectively. In order to successful TVS measurement, the gate leakage current density of films must be low 10$^{-9}$ (A/cm$^2$) order.der.

  • PDF

1인 가구를 위한 TV자동 제어 시스템 (TV Automatic Control System for Single-person Households)

  • 김은서;임재윤;김선희
    • 반도체디스플레이기술학회지
    • /
    • 제21권1호
    • /
    • pp.44-49
    • /
    • 2022
  • The number of single-person households is increasing worldwide, and among them, the proportion of elderly single-person households is increasing. In the case of elderly single-person households, a significant portion of their leisure time is devoted to watching TV. However, if they fall asleep while watching TV without turning it off, it may be difficult to sleep well due to lights and sounds of TV, which can cause health problems such as depression and reduced immunity. Therefore, in this paper, we propose a system that automatically turns off the TV when a person watching TV falls asleep. Images are collected using the camera installed in front of the TV. Since the posture of a person watching TV varies from a sitting posture to a lying posture, the system is designed to determine whether or not to fall asleep regardless of the posture. In addition, since it becomes difficult to judge eye movements as a person moves away from the TV, a method for extending the judgmentable distance is proposed. The system model was implemented and tested using a Raspberry Pi, a monitor, an infrared sensor, and a camera. Eye movements were judged regardless of sitting or lying position, and the distance between a user and a TV was extended by about 200 cm.

삼각전압소인법을 이용한 강유전체 박막내에서의 분극 및 유동이온에 대한 평가 (Evaluation of polarization and mobile charge in ferroelectric films using TVS(Triangular Voltage Sweep) method)

  • 김용성;이남열;정순원;김진규;정상현;김광호;유병곤;이원재;유인구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.86-89
    • /
    • 2000
  • The detection technique both the polarization and the mobile charge density at the same time in ferroelectric films on Si using TVS method have been proposed. This method yields a polarizable and an ionic displacement current peaks whose areas are proportional to the total polarization reversal charge and the total moble ionic space charge, respectively. The calculated polarization and the mobile charge density were 0.42 [$\mu$C/$\textrm{cm}^2$] and 5.5$\times$10$^{11}$ (ions/$\textrm{cm}^2$) in the SBT film of MFIS structure measured at 25$0^{\circ}C$, and 1.4 [$\mu$C/$\textrm{cm}^2$] in the LiNbO$_3$ film of MFS structure measured at 30$0^{\circ}C$, respectively.

  • PDF

3차원 TV 기술의 현재와 미래

  • 손정영
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1995년도 광학 및 양자전자학 워크샵 논문집
    • /
    • pp.121-125
    • /
    • 1995
  • 3차원 영상 기술에는 여러 가지 종류가 있다. 지금까지 알려진 방법중 가장 뛰어난 3차원 영상기술은 홀로그래피이다. 그러나 헐러그래피를 이용하여 3차원 TV를 구현하는 데는 많은 문제점이 있다. 그 문제점 중의 하나가 홀로그램이 가지고 있는 많은 데이터 량이다. 홀로 그램의 1cm2당에 포함된 데이터 량은 1Gbits이상이다. 그 외에도 천연색 재생, 자연 광경의 찰영 문제 등 여러 가지가 있다. 기술적 어려움을 제외하고도 기존 기술에의 적용 가능성도 문제가 있다. 이러한 문제점을 고려할 때 그래픽 방식의 3차원 TV의 개발은 장기적 측면에서 추진해야 한다.

  • PDF

기생 커패시턴스 저감형 공통모드초크의 특성해석에 관한 연구 (A Study on Characteristics Analysis of Common-Mode Choke with Reduced Parasitic Capacitance)

  • 원재선;김희승;김종해
    • 전력전자학회논문지
    • /
    • 제20권2호
    • /
    • pp.137-143
    • /
    • 2015
  • This paper presents the intra capacitance modeling based on the winding method and section bobbin for CM choke capable of EMI attenuation of broad bands from lower to higher frequency bands and high frequency type common-mode choke capable of EMI attenuation of high frequency band used in the EMI Block of LED-TV SMPS. The case of high frequency type CM choke can be explained by the parasitic capacitance of three types of CM choke. The winding method of section bobbin type is smaller than the others. The first resonant frequency of the proposed CM choke tends to increase as the parasitic capacitance becomes small and its impedance characteristics improved performance as the first resonant frequency increases. The CM chokes of the proposed section bobbin type shows that in the future, the method may have practical use in LED/LCD-TV SMPS and in several applications, such as LED lighting, adapters, and so on.

TV-CM디자인에서의 수묵화적 표현에 관한연구 (A study on the expression of Indian Ink in television commercial)

  • 번강강;김맹호
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2009년도 춘계 종합학술대회 논문집
    • /
    • pp.229-234
    • /
    • 2009
  • 현대사회는 산업의 다양화로 디자인 영역은 다각화로 확장되어 가고 있으며 여러 학문들과 통합과 통섭 등 을 통하여 여러 가지 새로운 기능성을 제시하고 있다. 사람들의 사고방식, 감성의 변화, 그리고 행동양식에도 큰 변화가 일어나 새로운 표현방식과 미적 가치를 추구하다. 그러함 속에서 전통에 대한 새로운 인식 혹은 새로운 소재로서 수묵화 표현이 늘어나고 있다. 본 고 에서는 수묵이 나타나게 된 역사적, 사회적 배경을 기초하여 그 표현방식과 분석을 중심으로 고찰하였고 동양적 전통미와 정서적 감성에 부합되는 미적 가치로서 수묵화적 표현을 제시하였다. TV-CM디자인에 나타난 수묵표현의 활용에 대해 연구하는 것으로 수묵의 개념, 특징, 분류, 표현방식을 분석하고 새로운 수묵기법 혹은 동양적 표현을 통하여 디자인 영역을 확대하고자 한다.

  • PDF

디지털 위성방송 시스템 (Digital DBS System)

  • 장규상
    • 방송공학회논문지
    • /
    • 제1권1호
    • /
    • pp.1-6
    • /
    • 1996
  • 무궁화 위성을 이용한 디지털 위성방송(DBS) 서비스가 한국통신 용인 송신소에서 실시된다. 위성방송 시스템은 방송국, 송신소, 위성 중계기 및 수신기로 구성된다. 송신소에는 6개의 위성중계기 수만큼의 송신기가 필요하며, 각 송신기는 MPEG-2 압축기술을 이용하여 4개의 TV프로그램을 압축하고 데이터 서비스와 다중화한 후 RF 신호로 변환하여 송출한다. 위성중계기의 수신된 신호를 주파수 변환 및 증폭하여 지상으로 재 송출하고, 수신기는 45cm 안테나를 이용하여 수신한 후 역 다중화를 통해 원하는 프로그램을 선택한 후 디코딩을 하여 원 신호를 복원한다. FEC 부호화와 QPSK 변조를 사용하여 전송 BER 10E-11을 구현하였다. 유료 채널 관리를 위해 한정 수신 시스템, 스마트카드와 모델을 사용하였다.

  • PDF

3D TV 근거리 시청에 따른 사위도와 조절성폭주비 평가 (The Evaluations of Phoria and AC/A Ratio by Watching 3D TV at Near)

  • 손정식;김동수;김정호;김재도;앨러릭 하마커;유동식
    • 한국안광학회지
    • /
    • 제20권3호
    • /
    • pp.319-324
    • /
    • 2015
  • 목적: 3D TV의 근거리 시청에 따른 사위와 조절성폭주비의 변화와 회복 시점을 평가하고자 하였다. 방법: 3D TV 시청이 가능한 20~40대의 50명(남 30명, 여 20명)을 대상으로 하웰(Howell) 사위 카드를 사용하여 원거리(3 m)와 근거리(40 cm)에서 사위도를 측정하였다. 시청 거리는 1 m이며 시청 전, 시청 시간 30분 동안 10분 간격으로, 시청 이후 30분 동안 5분 간격으로 사위도를 측정하였다. 결과: 3D 영상 시청의 원거리 사위도 변화는 3D영상 시청 전 $-0.80{\pm}1.12{\Delta}$과 비교하여 10분, 30분 후 각각 $-0.98{\pm}1.37{\Delta}$(p=0.063), $-1.00{\pm}1.28{\Delta}$(p=0.024)로 외사위 경향으로 증가하였으며, 영상 시청 종료 후에는 외사위도가 감소하기 시작하여 20분 이후에는 $-0.78{\pm}1.11{\Delta}$로 시청 전 사위도 수준으로 회복되었다(p=0.322). 근거리 사위도 역시 영상 시청 전 $-4.36{\pm}3.66{\Delta}$과 비교하여 10분, 30분 후 각각 $-5.71{\pm}4.45{\Delta}$(p=0.000)과 $-6.58{\pm}4.63{\Delta}$(p=0.000)으로 외사위 방향으로 증가하였으며, 영상 시청 종료 후에는 외사위도가 감소하기 시작하여 25분 이후에는 $-4.34{\pm}3.67{\Delta}$로 시청 전 사위도 수준으로 회복되었다(p=0.322). 조절성폭주비는 영상 시청 전 $4.92{\pm}1.17{\Delta}/D$과 비교하여 영상시청 30분 후 $4.11{\pm}1.50{\Delta}/D$로 낮아졌으며(p=0.000), 영상 시청 종료 후에는 증가하기 시작하여 25분 후 $4.93{\pm}1.18{\Delta}/D$으로 시청 전으로 회복되었다(p=0.598). 결론: 근거리 3D TV 시청 시에 원거리보다 근거리의 외사위도가 더 크게 증가하였으며, 이로 인해 조절성폭주비는 낮아져 폭주부족의 경향을 보였다. 그러나 시청 후 25분 후에는 증가된 원거리와 근거리의 외사위도 모두 시청 전의 상태로 회복되었다. 따라서 3D TV 시청에 관한 합리적인 시청 권고안을 제시할 필요가 있는 것으로 본다.

CT조영제가 방사선치료계획(두경부, 전립선)에 미치는 영향 (Effect of CT Contrast Media on Radiation Therapy Planning (Head & Neck Cancer and Prostate Cancer))

  • 장재욱;한만석;김민정;강현수
    • 한국자기학회지
    • /
    • 제26권5호
    • /
    • pp.173-178
    • /
    • 2016
  • 두경부와 전립선 암 환자에서 CT조영제가 방사선치료계획에 미치는 영향을 확인하고 선량계산 정확성 향상을 위하여 본 연구를 실시하였다. 30명의 환자에 대하여 Pinnacle 8.0 시스템을 이용하여 조영제에 의한 조직의 전자밀도 변화를 측정하였으며 각각의 방사선치료계획을 통한 선량계산을 실시하였다. Pinnacle과 Tomotherapy planning 시스템을 이용하여 각각의 전자밀도와 3D 입체조형방사선치료(3D CRT)와 세기변조방사선치료(IMRT)계획을 수립하였다. 조영제에 의한 전자밀도의 변화는 4%이하로 두경부: 표적용적 2.1%, 이하선 1.9%, 하악선 3.6%, 혀 0.9%, 척수 0.3%, 식도 2.6%, 하악골 0.1%, 전립선: 표적용적 0.7%, 림프절 1.1%, 방광 1.2%, 직장 1.5%, 소장 1.2%, 대장 0.6%, penile bulb 0.8%, 대퇴골두 -0.2%로 나타났다. 선량계산의 차이는 2.5% 이하의 선량 증가가 발생하였다(3D CRT: 두경부 0.69~2.51%, 전립선 0.04~1.14%, IMRT: 두경부 0.58~1.31%, 전립선 0.36~1.04%). 이러한 오차는 임상에서 허용 가능한 오차 이내이지만 영상융합(조영증강 영상과 조영증강 하지않은 영상)이나 ROI import 기능을 활용하여 조영 증강하지 않은 영상에서 선량계산을 실시한다면 1~3%의 방사선치료계획 선량 오차를 줄일 수 있을 것으로 기대된다.