• Title/Summary/Keyword: TURN

Search Result 6,946, Processing Time 0.032 seconds

Warrants of Permissive Left-Turn Signal Systems Based on a Cross Road Volumes (교차도로 교통량을 고려한 비보호좌회전 신호체계의 적용기준)

  • 김동녕;최종윤
    • Journal of Korean Society of Transportation
    • /
    • v.21 no.4
    • /
    • pp.67-77
    • /
    • 2003
  • The purpose of this study is to provide the criteria for implementing unprotected left turn at intersections with variation of traffic volume on a cross road approach. Using Transyt-7F model, the delays calculated from permissive and protected left turn signal system were compared by gradually increasing the left turn volume for a certain opposing through volume up to the volume limits to which permissive left turn is more effective, Average stopped delay of the intersection was used as the measure of effectiveness in this study. The major conclusions are (1) the lighter the traffic gets in a cross road, the more the allowable left turn volume increases. The allowable left turn volume when the ratio of cross traffic to the concerned approach traffic is 0.6 appears about 50% more than the volume when the ratio is 1.0. (2) Comparing to the criteria of the manual of traffic safety facility, the results when the traffic ratio is 0.6 seem to be most similar the criteria of manual and the results when the traffic ratio are 0.8 and 1.0 appears to be lower than the criteria of manual. (3) The possible amount of making a left turn that is inversely proportional to the opposing through traffic, decreases as the number of opposing through lanes increases. The products of volume need to be used as the criteria of permissive left turn with considerable cautions because of its low consistency.

Traffic Signal Timing at Semi-Protected Left-Turn Intersections for Energy Saving (에너지절약을 위한 반보호 좌회전 교차로의 신호시간설계)

  • 김경환
    • Journal of Korean Society of Transportation
    • /
    • v.5 no.2
    • /
    • pp.19-35
    • /
    • 1987
  • Transportation energy saving is a national concern because all national petroleum energy is imported. A number of intersections are operating as semi-protected intersections, which have left-turn signal but not exclusive left-turn lanes, because of limited roadways in urban areas. Since the traffic signal methods for the intersections having left-turn signal/lanes cannot be applied to the semi-protected intersection, it is needed to develop a new technique. The purpose of this study was to develop a traffic signal timing method at semi-protected intersections for energy saving and to computerize the method for the practical use. A probability model which could estimate left-turn utilization factors of through traffic during green signal was developed based on field studies. Employing the factors, macro-models to estimate vehicular average delay and proportions of vehicles stopped at the semiprotected intersections were developed. The calculated values of the delay model agreed well with the simulated values of a simulation model using SLAM Ⅱ, a simulation language. Using the two models and the idling fuel consumption rate and the excess fuel consumption per stop-go speed change of vehicles. a traffic signal timing method at semi-protected intersections for energy saving was developed and computerized. The method can be used for other measures of effectiveness such as minimum delay, minimum stop ratio, etc.

  • PDF

High Frequency Soft Switching Forward DC/DC Converter (고주파 소프트 스위칭 Forward DC/DC 컨버터)

  • 김은수;최해영;조기연;김윤호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.19-25
    • /
    • 1999
  • To achieve high efficiency in high power and high frequency applications, reduction of switching losses and noise is very important. In this paper, an improved zero voltage switching forward dc/dc converter is proposed. The proposed converter is constructed by using energy recovery snubbers in parallel with the main switches and output diodes of the conventional forward dc/dc converter. Due to the use of the energy recovery snubbers in the primary and secondary side, the proposed converter achieves zero-voltage-switching turn-off without switching losses for switching devices and output rectification diodes. The complete operating principles and experimental results will be presented.

Current Limiting and Voltage Sag Suppressing Characteristics of Flux-lock Type SFCL According to Variations of Turn Number's Ratio (자속구속형 초전도전류제한기의 권선비 변화에 따른 전류제한 및 전압강하 보상 특성)

  • Han, Tae-Hee;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.5
    • /
    • pp.410-415
    • /
    • 2011
  • In this paper, we investigated the fault current limiting and the load voltage sag suppressing characteristics of the flux-lock type SFCL, designed with the additive polarity winding, according to the variations of turn number's ratio and the comparative analysis between the resistive type and the flux-lock type SFCLs were performed as well. From the analysis for the short-circuit tests, the flux-lock type SFCL designed with the larger turn number's ratio was shown to perform more effective fault current limiting and load voltage sag suppressing operations compared to the flux-lock type SFCL designed with the lower turn number's ratio through the fast quench occurrence of the high-$T_C$ superconducting (HTSC) element comprising the flux-lock type SFCL. In addition, the recovery time of the flux-lock type SFCL after the fault removed could be confirmed to be shorter in case of the flux-lock type SFCL designed with the lower turn number ratio.

Development of Gap Acceptance Models for Permitted Left Turn Intersections (비보호좌회전에서의 간격수락 행태모형 개발)

  • Lee, Chung Won;Lee, Dong Min;Hwang, Soon Cheon
    • International Journal of Highway Engineering
    • /
    • v.18 no.5
    • /
    • pp.95-103
    • /
    • 2016
  • PURPOSES : Permitted left turn is a turning maneuver in which a vehicle turns left using a gap between oncoming vehicles, called gap acceptance, and it enables for more efficient traffic operation at intersections. In Korea, the permitted left turn has not been a common maneuver at signalized or un-signalized intersections. However, many experts and the Police Agency tried to apply this effective turning maneuver at intersections in Korea since 2010. Though the investigation of gap acceptance is significantly important in understanding a driver's behavior at intersections, there have not been many studies about this topic, specifically a study to develop probability models of gap acceptance behavior. METHODS : In this study, the probability model of gap acceptance behavior for a permitted left turn was developed based on observational field studies. To develop the model, seven variables were analyzed including gap, waiting time, traffic volume, conflict-flow vehicle type, left-turning vehicle type, the number of lane, and time. RESULTS : In the final model, gap and left-turning vehicle type were found to be significant influencing factors. CONCLUSIONS : Through this model development, it was concluded that as the gap size increased, the probability of gap acceptance was higher. Moreover, when a left-turning vehicle was a passenger car, the probability of gap acceptance was higher than compared to large size buses or freight cars.

A study on the characteristics of heat transfer and pressure drop in plate type evaporator with U-turn for automotive air conditioner (유턴 흐름을 갖는 차량공조용 플레이트형 증발기의 전열특성에 관한 연구)

  • 강정길;김종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.472-483
    • /
    • 1999
  • The evaporation heat transfer and pressure drop characteristics for HFC-l34a in flat plate type heat exchangers with enhanced beads were experimentally investigated. Three plate type evaporators with different geometric condition of U-turn area were tested. Mass fluxes were tested over the range of 83kg/$m^2$s to 166kg/$m^2$s, and heat fluxes were varied from 4㎾/$m^2$ to 12㎾/$m^2$. Evaporation temperature was 5$^{\circ}C$ with inlet qualities of 0.1 to 1.0. There was no notable difference in the heat transfer coefficient by geometric variation of U-turn area, but the third plate with cross-ribbed channel at U-turn area was better than others in the evaluation using volume goodness factor comparison. Also, the mixtures of HFC-l34a and PAG oil was tested to determine oil effects on heat transfer and pressure drop. As oil concentration was increased, heat transfer coefficient was increased by 22~48% up to the 3wt.%, but decreased by 14~22% at the 4wt.%. The pressure drop was increased by the maximum of 100% as oil concentration was increased.

  • PDF

Comparative Analysis of Biomechanical Factors in Performing Techniques of 1/1Turn, Stretched, and Tucked on the Old Vaulting Horse and the New Vaulting Table (신.구형도마에서 1/1Turn, Stretched, Tucked 기술수행 시 운동역학적 분석)

  • Kim, Ji-Tae;Heo, Seong-Gyu
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.4
    • /
    • pp.135-145
    • /
    • 2006
  • The aim of this study was to find out the differences of biomechanical factors from touching down the vaulting board to landing when techniques of 1/1Turn, stretched, and Tucked were performed on the old vaulting horse and on the new vaulting table. Three national representative men gymnasts were sampled for this study. Three dimension motion analyses by means of six Sony PD-150 video cameras with the velocity of 60 fps were used. As a result of analyzing the kinetic data from two kind of vaulting table, the following conclusions were made. 1. There was not significant differences of angular momentum between the old and the new vaulting table in all three techniques except the phase of stepping on the vaulting board and contacting the vaulting horse in the Tucked technique. IN the two phases above, the angular momentum in the new vaulting table was greater than that of the old vaulting horse. 2. There were few significant differences between the old and the new vaulting horses in the horizontal and vertical reaction force according to techniques when stepping was performed. However, it appeared tendency that the horizontal and vertical reaction force in the new vaulting table was a little greater than that of the old vaulting horse when the 1/1Turn, the Stretched and the Tucked were performed.

Improvement of Turn-off Switching Characteristics of the PT-IGBT by Proton Irradiation (양성자 조사법에 의한 PT-IGBT의 Turn-off 스위칭 특성 개선)

  • Choi, Sung-Hwan;Lee, Yong-Hyun;Kwon, Young-Kyu;Bae, Young-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.12
    • /
    • pp.1073-1077
    • /
    • 2006
  • Proton irradiation technology was used for improvement of switching characteristics of the PT-IGBT. Proton irradiation was carried out at 5.56 MeV energy with $1{\times}10^{12}/cm^2$ doze from the back side of the wafer. The I-V, breakdown voltage, and turn-off delay time of the device were analyzed and compared with those of un-irradiated device and e-beam irradiated device which was conventional method for minority carrier lifetime reduction. For proton irradiated device, the breakdown voltage and the on-state voltage were 733 V and 1.85 V which were originally 749 V and 1.25 V, respectively. The turn-off time has been reduced to 170 ns, which was originally $6{\mu}s$ for the un-irradiated device. The proton irradiated device was superior to e-beam irradiated device for the breakdown voltage and the on-state voltage which were 698 V and 1.95 V, respectively, nevertheless turn-off time of proton irradiated device was reduced to about 60 % compared to that of the e-beam irradiated device.

The Differences in the Ski Carving Turn Motion According to Level of Exper tise (스키 카빙턴 동작 시 기술 수준에 따른 동작의 차이 연구)

  • Eun, Seon-Deok;Hyun, Moo-Sung
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.3
    • /
    • pp.319-325
    • /
    • 2010
  • The purpose of this research was to investigate the differences in the ski carving turn motion according to level of expertise. The posture and movement of 6 skiers nearby the fall-line was evaluated with a biomechanical approach focusing the rotational mechanics. The slope was at an angle of $9^{\circ}$ and the following variables were measured and calculated: tangential velocity, change of COM height after passing fall-line, width between feet, angle between upper body and thigh, trunk angle, average radius of curvature and average centripetal force. The expert skiers minimized their center of mass height movement and maintained the width of between their feet after the passing the fall-line in comparison with the beginners and intermediate skiers. The experts restrained themselves from pushing their upper body downward after the turn to maximize the centripetal force. The experts in comparison with the beginners and intermediate skiers during the turn didn't have to reduce their radius of curvature to maintain a high centripetal force. It was concluded, that the most important factor affecting the centripetal force, was for the beginners and intermediate skiers, to minimize their movement while using the appropriate amount of edging.

An Analytical Study on the Thermal-Structure Stability Evaluation of Mill-Turn Spindle with Curvic Coupling (커빅 커플링을 적용한 밀-턴 스핀들의 열-구조 안정성 평가에 관한 해석적 연구)

  • Lee, Choon-Man;Jeong, Ho-In
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.1
    • /
    • pp.100-107
    • /
    • 2020
  • As demand for high value-added products with hard materials increases, the line center is used for producing high value-added products in many industries such as aerospace, automobile fields. The line center is a key device for smart factory automation that can improve the production efficiency and the productivity. Therefore, the development of a mill-turn line center is necessary to produce high value-added products with complex shapes flexibly. In the mill-turn process, a milling process and a turning process are combined. In particular, the turning process needs to increase the rigidity of the spindle. The purpose of this study is to analyze the thermal-structural stability through thermo-structural coupled analysis for a mill-turn spindle with a curvic coupling. The maximum temperature and thermal stability of the spindle were analyzed by thermal distribution. In addition, the thermal deformation and thermal-structural stability of the spindle were analyzed through thermo-structural coupled analysis.