황사가 서울시 대기 중 PAHs 농도에 미치는 영향 (The Influence of Yellow Sand Phenomena on the Concentration Variation of Polycyclic Aromatic Hydrocarbons in Ambient Air of Seoul)

  • 박찬구;어수미;기원주;김기현;모세영
    • 한국대기환경학회지
    • /
    • 제17권2호
    • /
    • pp.179-192
    • /
    • 2001
  • In order to characterize the distribution patterns of PAHs between Yellow Sand (YS) and non-Yellow Sand(NYS) periods, we collected and analyzed aerosol samples for PAHs for the periods covering 28 March through 24 April 2000. The concentrations of TSP measured during the YS periods were approximately two times higher than the NYS periods. By contrast, the concentrations of PAHs during YS were higher than those of NYS by 140%. In ad-dition, their concentrations in PM 10 were larger than those TSP by 120% . Detailed inspections of our data indi-catd that three species including chrysene. benzo(b)fluoranthene, and benzo(k)fluoranthene were effeciently ad-sorbed by particles less than 10${\mu}{\textrm}{m}$ diameter and that there were dominating the distribution characterstics of PAHs during the YS periods. Results of correlation analysis also indicated that PAHs exhibited strong correlations with those pollutants originating from combustion sources. It is thus concluded that pollutants such as toxic PAHs that originate from diverse anthropogenic sources of China should be contributing to the degradation of the ambient air quality in Seoul.

  • PDF

무창 비육돈사에서 습식공기정화기의 여름철 공기정화효율 분석 (An Air Cleaning Efficiencies of Wet Air Cleaner in the Windowless Swine Fattening Stall in Summer)

  • 오인환;이종현;이경훈;이정훈;이동섭;어성만;이미림
    • 한국축산시설환경학회지
    • /
    • 제12권3호
    • /
    • pp.133-140
    • /
    • 2006
  • The climate of stall significantly influences on animal production ability. High concentration of ammonia gas, $CO_2$ and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and farmer health, and production ability. Therefore, it is necessary to keep clean the inside air of stall to increase the productivity. An air cleaner of wet type, consisting of a fan, a motor, rotating discs, a dust collector, a water bowl, an ozone generator etc, has been developed to clean the stall air. The work principle is that the inside air is sucked through the fan, and the rotating discs make water into fineness spray and blow into the stall. The rest water flows down to the dust collector. In the present study, we measured the dust, ammonia gas, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with On-mode and Off-mode of wet air cleaners. The dust measure was divided into 3 categories, TSP, $PM_{10}$, and $PM_{2.5}$. In summer, the TSP in on-mode were maximum $0.259mg/m^3$ and minimum $0.128mg/m^3$, and the average was $0.195mg/m^3$. These are comparable to the data from Off-mode stall that maximum $0.308mg/m^3$, minimum $0.139mg/m^3$, and average $0.277mg/m^3$. However, $PM_{10}$ and $PM_{2.5}$ showed any significant differences between the tests. The concentrations of ammonia gas in Off-mode stall were maximum 13.8 ppm and minimum 5.9 ppm, and the average was 8.47 ppm. However in On-mode stall the ammonia gas concentrations were maximum 10.5 ppm and minimum 5.5 ppm, and the average was 7.63 ppm. The concentration of ammonia gas in On-mode was 10% in average lower than off-mode stall. Odor was measured by olfactometer. In the Off-mode stall, the odor unit were maximum 420 $Ou/m^3$ and minimum $300\;OU/m^3$, and the average was $367\;OU/m^3$, but in the On-mode stall the odor unit were maximum $330\;OU/m^3$ and minimum $210\;OU/m^3$, and the average was $253\;OU/m^3$. Odor removal efficiency was about 31% in On-mode stall.

  • PDF

제주도 고산지역 TSP, PM2.5 대기에어로졸의 조성 및 오염 특성 (Composition and pollution characteristics of TSP, PM2.5 atmospheric aerosols at Gosan site, Jeju Island)

  • 이순봉;강창희;정덕상;고희정;김행범;오용수;강혜림
    • 분석과학
    • /
    • 제23권4호
    • /
    • pp.371-382
    • /
    • 2010
  • 제주도 고산지역에서 TSP (total suspended particulate), PM2.5 (particulate matter, below $2.5\;{\mu}m$ particle size) 대기에어로졸을 채취, 분석하여 에어로졸의 조성과 오염 특성을 조사하였다. 고산지역 대기에어로졸에서 nss(non-sea salt)-$SO_4^{2-}$$NH_4^+$은 다른 국내 청정지역 및 도시지역에 비해 높은 조성비를보이고 $NO_3^-$는 상대적으로 낮은 조성비를 나타내었다. 에어로졸 성분의 입경별 분포를 비교해 본 결과, 인위적 기원의 nss-$SO_4^{2-}$, $NO3_^-$, $NH_4^+$ 성분들은 대체적으로 미세입자에, 토양기원의 nss-$Ca^{2+}$과 해염기원의 $Na^+$, $Cl^-$, $Mg^{2+}$은 상대적으로 조대입자에 많이 분포하고 있는 것으로 확인되었다. 계절별로는 봄철에 nss-$Ca^{2+}$, Al, Fe, Ca, $NO_3^-$ 성분의 농도가 크게 상승하고, nss-$SO_4^{2-}$은 여름과 봄철에 높은 농도를 나타내었다. 인자분석 결과, 에어로졸은 대체적으로 인위적 발생원의 영향을 많이 받고, 다음으로 해양 및 토양 영향을 많이 받았다. 또한 역궤적 분석법으로 에어로졸 성분의 유입경로를 조사해 본 결과, nss-$SO_4^{2-}$, $NO_3^-$, Pb, nss-$Ca^{2+}$ 성분들은 대체적으로 기류가 중국대륙으로부터 제주지역으로 이동할 때 훨씬 더 높은 농도를 나타낸 반면, 북태평양에서 제주지역으로 이동할 때 상대적으로 낮은 농도를 나타내었다.

통계적 기법을 활용한 서해안 화력발전소 오염물질 배출에 따른 수도권 지표면 대기오염농도 영향의 분석 (Statistically Analyzed Effects of Coal-Fired Power Plants in West Coast on the Surface Air Pollutants over Seoul Metropolitan Area)

  • 주재민;윤대옥
    • 한국지구과학회지
    • /
    • 제40권6호
    • /
    • pp.549-560
    • /
    • 2019
  • 본 연구는 화력발전소 배출로 인한 지표면 오염물질 농도의 시·공간적 영향을 실측 자료를 바탕으로 정량적으로 분석하려는 목적으로 수행되었다. 배출과 농도 관계의 정량적 분석을 위해 우선 기상 조건과 주변 배출원의 영향을 고려하였다. 이를 위해 자료의 선택과 관측지점 선정 과정을 제안하였고, 선정된 지표면 시·공간 자료에 K-Z 필터와 경험직교함수(EOF) 분석 기법을 적용하였다. 사용된 자료는 2014-2017년 4년의 기간 동안 당진과 태안 화력발전소 굴뚝 자동측정기기의 농도값을 이용하여 산출한 한 시간 평균 배출량 자료와 지표면 대기오염농도 측정망 자료이다. 기상 자료로는 최근 배포 중인 ERA5 재분석자료와 기상청 종관기상관측소 한 시간 평균 자료가 사용되었다. 발전소만의 영향이 최대한 보이도록 기상 효과와 지리적인 요인을 고려하여 선택한 시간대의 선정된 관측소 자료만을 이용하여 분석한 결과, 지표면 대기오염물질의 EOF 첫 번째 모드는 SO2, NO2, PM10 모두에 대해 97% 이상의 변동성을 설명하였다. 또한 지표면 농도장의 EOF 첫 번째 모드의 시계열은 화력발전소 배출과 유의미한 상관성을 보였다. 결과적으로 당진화력발전소 SO2, NO2, TSP 시간 당 배출량이 각각 10%가 감소하면, 남서풍 계열의 바람에 의해 직접 영향을 받는 서울 수도권 지표면 평균 SO2 농도는 0.468 ppb (R=0.384), NO2는 1.050 ppb (R=0.572), PM10은 2.045 ㎍ m-3 (R=0.343) 정도가 감소한다고 판단할 수 있다. 태안화력발전소의 경우, SO2, NO2, TSP 배출량을 각각 시간당 10% 씩 감축하면, SO2는 0.284 ppb (R=0.648), NO2는 0.842 ppb (R=0.683), PM10은 1.230 ㎍ m-3 (R=0.575) 정도가 감소될 수 있음을 확인하였다. 태안화력발전소는 당진화력발전소에 비해 수도권지역 농도에 미치는 영향은 작았으나, 상관관계는 더 높았다.

Physicochemical Properties of Indoor Particulate Matter Collected on Subway Platforms in Japan

  • Ma, Chang-Jin;Matuyama, Sigeo;Sera, Koichiro;Kim, Shin-Do
    • Asian Journal of Atmospheric Environment
    • /
    • 제6권2호
    • /
    • pp.73-82
    • /
    • 2012
  • This study was aimed to thoroughly estimate the characteristics of indoor particulate matter (PM) collected on subway platforms by the cooperative approach of semi-bulk and single particle analyses. The size-resolved PM and its number concentration were measured on the platform in a heavily traveled subway station in Fukuoka, Japan. Particle Induced X-ray Emission (PIXE) and micro-PIXE techniques were applied to the chemical analyses of semi-bulk and single particle, respectively. There was the close resemblance of timely fluctuation between PM number concentration and train service on the third basement floor (B3F) platform compared to the second basement floor (B2F) and its maximum level was marked in rush hour. Higher number counts in large particles ($>1{\mu}m$) and lower number counts in fine particles ($<1{\mu}m$) were shown on the platform compared to an above ground. PM2.5 accounted for 58.2% and 38.2 % of TSP on B3F and on B2F, respectively. The elements that were ranked at high concentration in size-resolved semi-bulk PM were Fe, Si, Ca, S, and Na. The major elements tending to have more elevated levels on B3F than B2F were Fe (4.4 times), Ca (17.3 times), and Si (46.4 times). Although concentrations were very low, Cr ($11.9ng\;m^{-3}$ on B3F, $2.4ng\;m^{-3}$ on B2F), Mn ($3.4ng\;m^{-3}$ on B3F, $0.9ng\;m^{-3}$ on B2F), and Pb ($0.6ng\;m^{-3}$ on B3F, $1.6ng\;m^{-3}$ on B2F) were detected from PM2.5. Individual PM was nearly all enriched in Fe with Si and Ca. Classifying and source profiling of the individual particles by elemental maps and particle morphology were tried and particles were presumably divided into four groups (i.e., train/rail friction, train-rail sparking, ballast/abrasive, and cement).

서울시 용산구 지역에 이산화황 농도의 시계열 변동과 영향인자 분석 (The Analysis of Time Series of SO2 Concentration and the Control Factor in An Urban Area of Yongsan-gu, Seoul)

  • 김보원;김기현
    • 한국지구과학회지
    • /
    • 제35권7호
    • /
    • pp.543-553
    • /
    • 2014
  • 서울특별시 용산구의 측정망에서 2004년부터 2013년간 관측한 대기질 자료를 중심으로 $SO_2$의 환경거동을 시간적 기준으로 다양한 관점에서 분석하였다. 이와 동시에 관측한 기타 대기오염물질들($PM_{2.5}$, $PM_{10}$, TSP, $CH_4$, CO, NO, $NO_2$, NOx, $O_3$, THC, NMHC)의 농도자료와 기상자료들과의 관계를 해석하는 방식으로 $SO_2$의 거동을 조사하였다. 10년간 측정한 용산구 지역에서 측정한 $SO_2$의 연간 평균농도는 대기환경기준치인 $20nmole\;mole^{-1}$보다 5배 정도 낮은 4.36-5.86(최저-최고) $nmole\;mole^{-1}$ 수준으로 나타났다. 이는 연간 평균농도가 관리기준치를 초과하는 성분들과 뚜렷하게 대조적인 양상을 보였다. 여러 가지 통계적 기법을 적용하여 $SO_2$의 배출량에 영향을 미치는 요인들을 파악하였다. 그리고 용산구에서 측정한 $SO_2$와 기타대기오염물질, 기상자료들의 경향성을 비교해보았다. $SO_2$은 온도 및 기타물질들에 대한 상관성이 있는 것으로 나타났다. 또한 본 연구의 결과에 의하면, $SO_2$은 다른 대기오염물질들에 비해 상대적으로 관리가 잘 이루어지고 있다는 것을 확인할 수 있다.

서울지역의 시정 장애 요인에 관한 연구 (On the Origin of Visibility Degradation in Seoul)

  • 윤순창;이강웅
    • 한국대기환경학회지
    • /
    • 제14권3호
    • /
    • pp.229-236
    • /
    • 1998
  • Visibility is a good indicator of comprehensive alto quality. The prevailing visibility in Seoul is no better than the past although the average concentration of SO2 and TSP (total suspended particulate) has decreased quite significantly in the past decade, owing to the government efforts to reduce the emission. Then, a question arises why visibility has not been improved. In order to answer this question we have investigated which components of air pollutants are most responsible for the visibility degradation in Seoul. Analysis on the visibility vs the aerosol sixte distribution measured by an optical particle counter shows that the particles of the size interval between 0.5mm and 2.5mm are most responsible for the visibility degradation. Among the criteria air Pollutants, NOB concentration is found to be moot responsible, rather than PM10. ton analysis of the particulate collected by a high volume sampler shows that the nitrate component increases more significantly than other ions when visibility becomes very poor. Therefore, we conclude that the major causes of visibility degradation in Seoul are the increase of NOB, nitrates and the particles of the size range between 0.5mm and 2.5mm.

  • PDF

공사장 먼지피해 예방을 위한 먼지피해 배상액 산정 현실화 방안 연구 (A Study on the Realization of Dust Damage Compensation Calculation for the Prevention of Dust Damage in Construction Site)

  • 김진호
    • 한국재난정보학회 논문집
    • /
    • 제18권2호
    • /
    • pp.374-385
    • /
    • 2022
  • 연구목적: 1급 발암물질이 포함된 공사장 먼지로 인해 피해 발생 시 피해 배상 신청을 해도 기각되거나 소음피해 배상금액의 5~30%정도만 지급하고 있다. 그런 허점 때문에 일부 건설사들은 공사장 먼지관리를 소홀히 하고 있어서 공사장 내 작업자들과 인근 주민들의 피해가 지속되고 있다. 그에 대한 해결방안을 제시코자 한다. 연구방법: 공사장 먼지의 피해배상액 산정기준 문제점, 먼지 농도 측정, 측정자료(광산란법에 의한 전광판 측정기 자료) 분석, 모델링 등 예측, 평가 방법의 문제점을 고찰하고, 개선방안을 제시코자 한다. 연구결과:현재의 공사장 먼지 피해 배상액산정기준과 먼지농도 모델링 및 측정으로는 공사장 먼지피해 배상액 산정이 불가한 것으로 드러나 개선이 시급한 것으로 나타났다. 결론:공사장피해가 예상되는 지점 내(부지경계선과 직선거리100m 내외)에서 피해배상 신청을 받고, 먼지관련 법적 기준인 비산먼지 억제조치기준들의 준수여부와 먼지관리 정도로 먼지피해를 차등 평가하는 배상액 산정방안을 제시한다.

한우사 내부 위치 및 TMR 배합 작업에 따른 분진 모니터링 (Dust Concentration Monitoring in Korean Native Cattle Farm according to Sampling Location and TMR Process)

  • 박관용;권경석;이인복;여욱현;이상연;김준규
    • 한국농공학회논문집
    • /
    • 제59권4호
    • /
    • pp.75-83
    • /
    • 2017
  • Many parts of problems in livestock industry today are associated with organic dust. Endotoxin and toxic gasses on the surface of dust and dust itself can cause aesthetic displeasure and respiratory disease. It also reduces livestock productivity by suppressing immunity of animals and carrying microbes causing animal disease. However, dust level of cattle farm was rarely reported in Korea, and regulation for cattle farm worker does not exist. In this paper, dust concentration and environmental condition were regularly monitored in a commercial Korean native cattle farm. The measurement was conducted according to location and working activities. From the measurement, distribution of dust concentration was affected by wind environment, as the result of natural ventilation. TMR mixer was a major source of dust in target cattle house. The maximum inhalable dust concentration was 637.8 times higher than exposure limit as feed dropped into the TMR mixer. It was expected that dust generation could be affected by particle size and drop height of feed. This study suggests potential risk of dust in cattle farm, and necessity for latter study. Effect of aerodynamic condition and TMR processing should be investigated for dust reduction study.

고형연료제품 사용시설에서 배출되는 미세먼지 입경분율 분석 (Analysis of the Fine Particulate Matter Particle Size Fraction Emitted from Facilities Using Solid Refuse Fuel)

  • 유한조;정연훈;김진길;신형순;임윤정;이상수;손해준;임삼화;김종수
    • 한국환경보건학회지
    • /
    • 제46권6호
    • /
    • pp.719-725
    • /
    • 2020
  • Objectives: With the growth of national interest in fine particulate matter, many complaints about pollutants emitted from air pollution emitting facilities have arisen in recent years. In particular, it is thought that a large volume of particulate pollutants are discharged from workplaces that use Solid Refuse Fuel (SRF). Therefore, particulate contaminants generated from SRF were measured and analyzed in this study in terms of respective particle sizes. Methods: In this study, particulate matter in exhaust gas was measured by applying US EPA method 201a using a cyclone. This method measures Filterable Particulate Matter (FPM), and does not consider the Condensable Particulate Matter (CPM) that forms particles in the atmosphere after being discharged as a gas in the exhaust gas. Results: The mass concentration of Total Suspended Particles (TSP) in the four SRF-using facilities was 1.16 to 11.21 mg/Sm3, indicating a very large concentration deviation of about 10 times. When the fuel input method was the continuous injection type, particulate matter larger than 10 ㎛ diameter showed the highest particle size fraction, followed by particulate matter smaller than 10 ㎛ and larger than 2.5 ㎛, and particulate matter of 2.5 ㎛ or less. Contrary to the continuous injection type, the batch injection type had the smallest particle size fraction of particulate matter larger than 10 ㎛. The overall particulate matter decreased as the operating load factor decreased from 100% to 60% at the batch input type D plant. In addition, as incomplete combustion significantly decreased, the particle size fraction also changed significantly. Both TSP and heavy metals (six items) satisfied the emissions standards. The measured value of the emission factor was 38-99% smaller than the existing emissions factor. Conclusions: In the batch injection facility, the particulate matter decreased as the operating load factor decreased, as did the particle size fraction of the particulate matter. These results will help the selection of effective methods such as reducing the operating load factor instead of adjusting the operating time during emergency reduction measures.