• 제목/요약/키워드: TSP and PM10 concentration

검색결과 64건 처리시간 0.024초

익산지역에서 황사발생시 PM2.5, PM10 TSP의 농도 특성 (Concentration Characteristics of Atmospheric PM2.5, PM10 and TSP during the Asian Dust Storm in Iksan Area)

  • 강공언;김남송;김경숙;김미경;이현주
    • 한국환경보건학회지
    • /
    • 제33권5호
    • /
    • pp.408-421
    • /
    • 2007
  • The concentration characteristics of atmospheric particle matters (PM) including $PM_{2.5},\;PM_{10}$, and TSP were evaluated through the measurement data of PM_{2.5}$ (fine particulate), PM_{10-2.5}$ (coarse particulate), and PM_{over-10}$ collected using a MCI (multi-nozzle cascade impactor) sampler of a three-stage filter pack in spring of 2006 in Iksan area. During the sampling period of 10-15 March and 24 days from 8 April to 2 May, 32 samples for PM of each size fractions were collected, and then measured for PM mass concentrations and water-soluble inorganic ion species. Average concentrations of $PM_{2.5},\;PM_{10}$, TSP were $57.9{\pm}44.1mg/m^3$, $96.6{\pm}89.1mg/m^3$, and $114.8{\pm}99.7mg/m^3$, respectively. Water-soluble inorganic ion fractions to PM mass were found to be 36.5%, 18.0%, and 11.1% for $PM_{2.5}$, $PM_{10-2.5}$ and $PM_{over-10}$, respectively. By showing the high concentrations of PM samples during Asian dust events, those three fractions of PM were distinguished between the samples of Asian dust event and the samples of no event. However, the increase of PM concentrations observed during Asian dust events showed a different pattern for some Asian dust events. The differences of those three fractions in the size distribution may depend on differences on place of occurrence of Asian dust storm and course of transport from China continent to Iksan area in Korea. However, the extent of PM mass contribution during Asian dust events was generally dominated by the coarse particles rather than the fine fraction of PM. The variations of water-soluble inorganic ion species concentration in those three PM fractions between the samples of Asian dust event and the samples of no event were also discussed in this study.

대구 안심연료단지 환경오염물질 노출 평가(II) - TSP, PM10, PM2.5 및 중금속 농도분포 및 노출특성 - (Exposure Assessments of Environmental Contaminants in Ansim Briquette Fuel Complex, Daegu(II) - Concentration distribution and exposure characteristics of TSP, PM10, PM2.5, and heavy metals -)

  • 정종현;피영규;이준정;오인보;손병현;이형돈;윤미라;김근배;유승도;민영선;이관;임현술
    • 한국산업보건학회지
    • /
    • 제25권3호
    • /
    • pp.380-391
    • /
    • 2015
  • Objectives: The objective of this study is to assess airborne particulate matter pollution and its effect on health of residents living near Ansim Briquette Fuel Complex and its vicinities. Also, this study measured and analyzed the concentration of TSP, $PM_{10}$, $PM_{2.5}$, and heavy metals which influences on the environmental and respiratory disease in Ansim Briquette Fuel Complex, Daegu, Korea. Methods: In this study, we analyzed various environmental pollutants such as particulate matter and heavy metals from Ansim Briquette Fuel Complex that adversely affected local residents's health. In particular, we verified the concentration distribution and characteristics of exposure for TSP, $PM_{10}$, and $PM_{2.5}$ among particulate matters, and heavy metals(Cd, Cr, Cu, Mn, Ni, Pb, Fe, Zn, and Mg). In that regard, the official test method on air pollution in Korea for analysis of particulate matter and heavy metal in atmosphere were conducted. The large capacity air sampling method by the official test method on air pollution in Korea were applied for sampling of heavy metals in atmosphere. In addition, we evaluated the concentration of seasonal environmental pollutants for each point of residence in Ansim Briquette Fuel Complex and surrounding area. The sampling measured periods for air pollutants were from August 11, 2013 to February 21, 2014. Furthermore, we measured and analyzed the seasonal concentrations(summer, autumn and winter). Results: The average concentration for TSP, $PM_{10}$, and $PM_{2.5}$ by direct influence area at Ansim Briquette Fuel Complex were 1.7, 1.4 and 1.9 times higher than reference region. In analysis results of seasonal concentrations for particulate matter in four direct influence and reference area, concentration levels for winter were generally somewhat higher than concentrations for summer and autumn. The average concentrations for Cd, Cr, Mn, Ni, Pb, Fe, and Zn in direct influence area at Ansim Briquette Fuel Complex were $0.0008{\pm}0.0004{\mu}g/Sm^3$, $0.0141{\pm}0.0163{\mu}g/Sm^3$, $0.0248{\pm}0.0059{\mu}g/Sm^3$, $0.0026{\pm}0.0011{\mu}g/Sm^3$, $0.0272{\pm}0.0084{\mu}g/Sm^3$, $0.4855{\pm}0.1862{\mu}g/Sm^3$, and $0.3068{\pm}0.0631{\mu}g/Sm^3$, respectively. In particularly, the average concentrations for Cd, Cr, Mn, Ni, Pb, Fe, and Zn in direct influence area at Ansim Briquette Fuel Complex were 1.9, 3.6, 2.1, 1.9, 1.4, 2.6, and 1.2 times higher than reference area, respectively. The continuous monitoring and management were required for some heavy metals such as Cr and Ni. Moreover, the average concentration in winter for particulate matter in direct influence area at Ansim Briquette Fuel Complex were generally higher than concentrations in summer and autumn. Also, average concentrations for TSP, $PM_{10}$, and $PM_{2.5}$ were from 1.5 to 2.0 times, 1.2 to 1.8 times, and 1.1 to 2.3 times higher than reference area, respectively. In results for seasonal atmospheric environment, TSP, $PM_{10}$, $PM_{2.5}$, and heavy metal concentrations in direct influence area were higher than reference area. Especially, the concentrations in C station were a high level in comparison with other area. Conclusions: In the results, some particulate matters and heavy metals were relatively high concentration, in order to understand the environmental pollution level and health effect in surrounding area at Ansim Briquette Fuel Complex. The concentration of some heavy metals emitted from direct influence area at Ansim Briquette Fuel Complex were relatively higher than reference area. In particular, average concentration for heavy metals in this study were higher than average concentrations in air quality monitoring station for heavy metal for 7 years in Deagu metropolitan region. Especially, the residents near Ansim Briquette Fuel Complex may be exposed to the pollutants(TSP, $PM_{10}$, $PM_{2.5}$, and heavy metals, etc) emitted from the factories in Ansim Briquette Fuel Complex.

터널환기 무창육계사의 분진크기별 분포와 배출농도에 관한 연구 (Dust Spatial Distribution and Emission of Tunnel Ventilated Windowless Broiler Building)

  • 최희철;연규영;송준익;강희설;권두중;유용희;양창범;천상석;김용국
    • 한국축산시설환경학회지
    • /
    • 제12권3호
    • /
    • pp.115-122
    • /
    • 2006
  • 본 연구는 터널환기 무창육계사의 계사내부의 위치별 먼지 농도 분포와 배기홴에서 배출된 먼지의 확산범위를 알아보고자 수행하였으며 결과는 다음과 같다. 1. 입기구 방향의 계사 1/4 지점의 먼지농도는 TSP의 경우 $301.0{\sim}1,366.0\;{\mu}g/m^3$으로 입기구의 위치에 따라 차이가 있었다. 2. 터널홴 앞 3m 지점에서는 TSP $2065.8{\sim}3,092.2\;{\mu}g/m^3$, PM 2.5 $27.6{\sim}36.3\;{\mu}g/m^3$, PM 1.0 $8.3{\sim}11.3\;{\mu}g/m^3$으로 입기구에 비하여 증가하였다. 3. 배기홴으로부터 3m의 지점의 먼지 배출량은 TSP $354.8{\sim}574.8\;{\mu}g/m^3$으로 매우 높았으며 PM10 $94.4{\sim}156.2\;{\mu}g/m^3$, PM2.5 $14.6{\sim}18.0\;{\mu}g/m^3$, PM1.0 $6.0{\sim}6.4\;{\mu}g/m^3$ 이었다. 4. 배기홴으로부터 50m 떨어진 지점에서의 분진농도는 TSP $25.1\;{\mu}g/m^3$, PM10 $8.8\;{\mu}g/m^3$, PM2.5 $5.6\;{\mu}g/m^3$, PM1.0 $4.9\;{\mu}g/m^3$으로 매우 낮은 분진농도를 보였다. 5. 입기구와 배기구 간 분진농도의 차이는 TSP의 경우 입기구에서 $317.9\;{\mu}g/m^3$인데 비하여 배기구는 $2,678.5\;{\mu}g/m^3$로 8.42배 높았으며 PM10 7.4배, PM2.5 3.4배, PM1.0 1.6배 높았다. 6. 배기홴으로부터 거리별 분진의 배출농도는 3m 지점에서 $446.6\;{\mu}g/m^3$ 이었으나 20 m 지점에서는 $156.3\;{\mu}g/m^3$로 34.9% 수준이었고 PM10 34.9%, PM2.5 48.7%, PM1.0 86.8% 수준이었다.

  • PDF

서울시 대기관측망을 중심으로 부유분진 기준농도 초과자료를 이용한 시공간적 경향성 비교 연구 (The Patterns of the PM Air Quality Guidance Level in Seoul during 1990~2000)

  • 최여진;김민영;김기현
    • 한국지구과학회지
    • /
    • 제24권3호
    • /
    • pp.190-204
    • /
    • 2003
  • 본 연구에서는 서울시에 의해 운영되는 서울시내 31개 지역의 대기오염 자동측정망에서 1990년부터 2000년까지 11년 동안 측정한 자료 중, TSP와 PM$_{10}$에 대한 대기환경기준을 초과한 자료만을 선택적으로 분리한 후 여러 가지 통계적인 분석을 수행하였다. 이러한 연구목적에 맞추어, 각 토지 이용 상태별로 환경기준을 초과한 분진농도의 경향성을 비교해 본 결과, TSP의 경우 초과농도의 전반적인 발생분포가 녹지, 주거, 상업, 준공업지역 순서로 증가하는 양상을 보여주었다. 준공업 지역에서 351.0${\pm}$35.9${\mu}$g m$^3$로 가장 높은 초과농도를 보였다. PM$_{10}$의 초과농도는 주거지역에서 182.9${\pm}$42.4${\mu}$g m$^3$의 최고농도를 보이며, 초과농도분포는 준공업, 상업, 녹지, 주거지역 순서로 증가하는 양상을 보인다. 발생빈도수를 각 지점별 측정망수로 나누어 준 결과 주거지역에서 21회로 다른지역에 비해 높은 초과빈도수를 보였다. 이들 초과농도자료들만에 국한시켜 시간적 주기성을 분석한 결과에 따르면, 일반적으로 관측되는 부유분진 자료들과 차별화 된 경향성이 어느 정도 확인되었다. 특히 계절적인 주기로 구분하였을 때, 일반농도자료는 PM$_{10}$과 TSP 모두 겨울철에 가장 큰 농도를 보인데 반해, 초과농도는 다른 양상을 보여주었다. 이러한 연구결과, PM$_{10}$의 연도별 경향성에서 가장 주목할 점은 측정이 시작된 1995년 이후 초과농도의 크기가 지속적으로 감소함에도 불구하고, 그 발생빈도수는 최근에 들어 괄목할 만큼 증가하고 있다는 점을 들 수 있다.

Persulfate Wet Oxidation Method for the Determination of Total Phosphorus in Atmospheric Aerosols and Its Application for a Year-round Observation in Beijing

  • Okuda, Tomoaki;Gunji, Yuma;He, Kebin;Ma, Yongliang
    • Asian Journal of Atmospheric Environment
    • /
    • 제7권3호
    • /
    • pp.169-175
    • /
    • 2013
  • Measurement of the phosphorus concentration in aerosols in Beijing, which was a representative East Asian mega-city, was carried out. The optimum procedure for analyzing phosphorus in aerosols was found in this study. Recovery of phosphorus in environmental samples through the improved method was almost 100%. The concentration of phosphorus in TSP was $145{\pm}47\;ng/m^3$, with a seasonal variation showing high concentrations in winter and low concentrations in summer. The concentrations of phosphorus in $PM_{2.5}$ accounted for $35{\pm}6%$ of those in TSP, with no seasonal variations. The major source of phosphorus in aerosols in Beijing was soil dust, and additional sources of phosphorus in fine particles could be coal combustion and biomass burning.

포항 지역 대기에서 측정된 에어로졸 입자분포 특성 연구 (A Characteristic Study of the Aerosol Size Distribution in Pohang Province)

  • 서문혁;장혁상
    • 한국입자에어로졸학회지
    • /
    • 제8권4호
    • /
    • pp.151-160
    • /
    • 2012
  • Health effects caused by the ultrafine particles in ambient air are great concern to the public health, and the strict measuring and monitoring of the ambient aerosol are required. In this work, the characteristics of the aerosol size distribution in Pohang province are studied. Optical particle counters (Grimm APS 1108 and 1109) were used to measure the aerosol size distribution in the area. Locations near the national monitoring site located in the industrial and the residence area were selected for the measuring sites of this study, and the locations in border area between the industry and the residence were selected for the reference of the comparison. In the industry site, it is found that the concentration of aerosol particles near the size of 5 ${\mu}m$ appear characteristically and the fluctuations in concentration with respect to time are minimal. The mass concentration of the aerosol above 10 ${\mu}m$ in diameter in the industry area was found to fluctuate significantly. The mass portion of $PM_{10}$ and PM2.5 to TSP in the residence area were 83% and 51% respectively. In the industrial regional, it was found that the mass portion of PM10 and $PM_{2.5}$ to TSP were 76% and 35% respectively. In the boundary area the mass portion of $PM_{10}$ and $PM_{2.5}$ to TSP were 78% and 54% respectively.

중소도시에 위치한 집단 열 공급시설에서 배출되는 대기오염물에 의한 주변 대기질의 영향 조사 및 예측 (The Ivestigation and Estimate of Influence on Air Quality by the Exhaust of Air Pollutant from Facility of the District Heating Located in Small City)

  • 연익준;김광렬
    • 환경위생공학
    • /
    • 제18권3호통권49호
    • /
    • pp.1-10
    • /
    • 2003
  • This study was aimed to investigate the influence on the vicinity by air pollutant generated from facility of the district heating located in local small town. We selected the seven areas arround the surroundings of facility of the district heating, compared the air quality evaluated before and after operations of the facility, and estimated the diffusion of air pollutant exhausted from the facility using a ISC model. The result was that the concentration of TSP before and after operations of the facility was 89${\sim}$94${\mu}$g/m$^3$,and 72${\sim}$81${\mu}$g/m$^3$, respectively and the latter showed a decline in concentration. Also, there was no relationship between straight distance from the facility of the district heating and the concentration of TSP. This result was applicable to cases of PM-10 and SO$_2$. We also investigated the influence on the air around the neighbored area by air pollutant produced from facility of the district heating using ISCLT3 model. The adding-concentrations of TSP, SO$_2$,NO$_2$, and CO were 0.0019${\sim}$0.00183${\mu}$g/m$^3$, 0.0029${\sim}$0.5648ppb, 0.2924${\sim}$l.9837ppb,and 0.0087${\sim}$0.0590ppb, respectively. It is predicted that each concentration is added to pollutant exhausted from facility of the district heating and is about 1/100${\sim}$1/180,000 of present air quality. This has a tiny influence on general air quality. According to this analysis, the concentration of air pollutant is less effected to pollutants expected by the facility of the district heating than other pollutants emitted from mobil source or industrial complex, and etc.

비육돈사 작업 종사자의 호흡기 관련 공기 중 분진 농도 측정 및 분석 (Measurement and Analysis of Dust Concentration in a Fattening Pig House Considering Respiratory Welfare of Pig Farmers)

  • 권경석;이인복;황현섭;하태환;하정수;박세준;조예슬
    • 한국농공학회논문집
    • /
    • 제55권5호
    • /
    • pp.25-35
    • /
    • 2013
  • In swine house, dust generation comes from various sources and is known to be harmful both for the animals and the farmers because the dust contains biological and gaseous matters. When farmers are constantly exposed to the dusts, they can suffer chronic or acute respiratory symptoms and have high probability of manifesting various diseases. To address this problem, understanding of the mechanism of dust generation is very important. In this paper, the dust concentration of inhalable, respirable, TSP and $PM_{10}$ were monitored and analyzed according to the pig-activity level, ventilation quantity and feeding method in fattening pig house. From the measured results, in case of the concentration of TSP, an inverse-linear relation with ventilation rate ($R^2=0.88$) and linear relation with the installation height of feed supply pipe ($R^2=0.73$) were determined. However in case of the concentration of $PM_{10}$, no particular relationship with the variables was observed. Using the concentration of inhalable and respirable dust based on the pig-activity level, multi-variate regression analysis was conducted and results have shown that the movement of pigs can contribute to the dust generation (p<0.05, $R^2=0.71$, 0.61). The relationship determined between dust generation and environmental variables investigated in this study is very significant and useful in conducting dust-reduction researches.

집단 에너지 시설에 의한 주변 대기질 영향 (The influence on air quality of the surroundings by the facility of the district heating)

  • 연익준;주소영;이민희;손종렬;김광렬
    • 환경위생공학
    • /
    • 제17권2호
    • /
    • pp.18-25
    • /
    • 2002
  • The comparison of the air quality with the evaluation of the environmental assessment before and after operations of the heat source and of the flue-gas desulfurization facilities were studied. First of all, several sites were selected for the representative sample points, and then they were examined air quality of the surroundings. The results were that TSP(total suspended particulate) analysis after an operation of the heat source facility was $74~81{\mu}g/m^3$, PM-10 was $31~94{\mu}g/m^3$, and $SO_2$concentration was 0.002~0.009ppm, respectively. As the result of examination to the concentrations of diffused pollutants, there was no relations between TSP concentration of sample points and the effect of air quality according to the heating source. When we compared the neighbored area of the heating source with the other area, the concentration of air pollutants after an operation of the facility of the heating source was similar to the heating source, the neighbored area, and the other area. So we concluded that there was no the effect of the air pollution by producted pollutants from the heating source.

2011년 동아시아에서 기류의 이동 경로에 따른 청원에서 측정한 에어로졸 질량 농도 및 원소 성분 분석 (An Analysis of Aerosol Mass Concentrations and Elemental Constituents Measured at Cheongwon depending on the Backward Trajectories of Air Parcel in East Asia in 2011)

  • 김학성;변광태;정용승;최현정;김민정
    • 한국환경과학회지
    • /
    • 제21권7호
    • /
    • pp.855-863
    • /
    • 2012
  • This study analyzed mass concentrations of TSP, PM10 and PM2.5 and elemental constituents according to the isentropic backward trajectories of air parcel from Cheongwonin East Asia during the period January - October, 2011. Mass concentrations of the continental polluted airflow (CP) showed levels of TSP and PM10 mass concentrations higher than the continental background airflow (CB). Also, PM2.5 mass concentrations of anthropogenic fine particles ran higher in CP than in CB. The elemental constituents and elemental constituent ratio ended up varying depending on the origin of atmospheric aerosols generated. The average absolute content of elemental constituents reached its height in CB, the ratio of anthropogenically originating elements (PE) among the all elements (AE) analyzed marked a high in CP, and Mg+Na/AE reached its height in the oceanic airflow (OA). At the same time, TSP, PM10 and PM2.5 mass concentrations, the ratio of PM2.5/TSP and PE/AE element ratio ran higher in CP than CB. Episodes of large-scale transport of atmospheric pollutants as observed at Cheongwon were 8 cases and 22 days. The ratios of PM10, PM2.5 among TSP mass concentrations showed different results and the ratios of PM2.5 showed an increasing trend in the episodes of anthropogenic air pollution transport. Overall, dustfall episodes show a level of elemental constituents higher than those of anthropogenic air pollution.Dustfall episodes were observed to contain more of Fe, Al and Ca originating from continental soils and those of air pollution were observed to contain more of Zn, Mn, Cu and Pb. By difference in contents of absolute elemental constituents, episodes of anthropogenic air pollution showed a high PE/AE rate, and dustfall episodes a high SE/AE rate.