• Title/Summary/Keyword: TRV

Search Result 61, Processing Time 0.041 seconds

22.9kV GIS Modeling and Transient Recovery Voltage Analysis Using EMTP/RV (EMTP/RV를 이용한 22.9kV GIS 모델링과 과도회복전압 해석)

  • Jyung, Tae-Young;Baek, Young-Sik;Jeong, Ki-Seok;Park, Ji-Ho;Seo, Gyu-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.7
    • /
    • pp.1199-1205
    • /
    • 2010
  • The recent power system is required to a large size of facilities and high power technology according to increasing power demand. However, it could lead to spoiling the beauty of city and environment problem. The miniaturized facilities with large capacity such as GIS have been required in recent power system. The GIS(Gas Insulated Substation) using the SF6 insulation gas enables to miniaturize facilities with large capacity with high insulation performance. However, the substation installed GIS has required to new design model which is different from the conventional substation. The TRV(Transient Recovery Voltage) analysis on simple circuit may applied by differential equation. However, in case of relatively complicated system, EMTP(Electro Magnetic Transients Program) mainly has been used to design and simulate for transient analysis. This paper mainly design the 22.9 kV GIS system and analyze the transient recovery voltage of main circuit breaker using EMTP/RV. It also enables to easily design the other substation installed GIS with same maker and voltage level because the proposed GIS model consists of separated modules such as busbar, circuit breaker, bushing, CT, PT etc. Eventually, it contributes to comfortably compare the interrupting performance of circuit breaker and system TRV corresponding to the substation system configuration.

Study on the Performance Verification Method and Failure Mechanism of Grading Capacitor of a Two-break Circuit-breaker (2점절 차단기 균압용 콘덴서 절연파괴 고장 메커니즘 및 성능검증 방법에 관한 연구)

  • Oh, SeungRyle;Han, Kisun;Kim, TaeKyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.1
    • /
    • pp.11-15
    • /
    • 2019
  • Recently, the circuit-breaker rated voltage is getting higher as the transmission voltage increases. To increase the circuit-breaker rated voltage, a multi-break circuit-breaker which has two or more breakers in series is adopted. For multi-break circuit-breaker, a grading capacitor is used to mitigate the Transient Recovery Voltage(TRV) and control the voltage distribution across the individual interrupter units. However, all over the world, there are many failures such as mechanical damage, explosion due to insulation breakdown. Therefore, it is necessary to study the causes of failure and the new performance verification method. In this paper, we investigate the causes of dielectric breakdown of the grading capacitors in the KEPCO power system and propose the performance verification method.

Optimal Plan of Partially Accelerated Life Tests under Type I Censoring

  • Moon, Gyoung-Ae
    • Journal of the Korean Data and Information Science Society
    • /
    • v.5 no.2
    • /
    • pp.87-94
    • /
    • 1994
  • In this paper, we consider optimum plan to determine stress change times under the three-step stress PALTs, assuming that each test units follows an exponential distribution. The tampered random variable(TRV) model for the three-step stress PALTs setup are introduced, and maximum likelihood estimators(MLEs) of the failure rate and the acceleration factors are obtained. The change times to minimize the generalized asymptotic variance(GAVR) of MLEs of the failure rate and the acceleration factors are proposed for the three-step stress PALTs.

  • PDF

Can oliceridine (TRV130), an ideal novel µ receptor G protein pathway selective (µ-GPS) modulator, provide analgesia without opioid-related adverse reactions?

  • Ok, Hwoe Gyeong;Kim, Su Young;Lee, Su Jung;Kim, Tae Kyun;Huh, Billy K;Kim, Kyung Hoon
    • The Korean Journal of Pain
    • /
    • v.31 no.2
    • /
    • pp.73-79
    • /
    • 2018
  • All drugs have both favorable therapeutic and untoward adverse effects. Conventional opioid analgesics possess both analgesia and adverse reactions, such as nausea, vomiting, and respiratory depression. The opioid ligand binds to ${\mu}$ opioid receptor and non-selectively activates two intracellular signaling pathways: the G protein pathway induce analgesia, while the ${\beta}$-arrestin pathway is responsible for the opioid-related adverse reactions. An ideal opioid should activate the G protein pathway while deactivating the ${\beta}$-arrestin pathway. Oliceridine (TRV130) has a novel characteristic mechanism on the action of the ${\mu}$ receptor G protein pathway selective (${\mu}$-GPS) modulation. Even though adverse reactions (ADRs) are significantly attenuated, while the analgesic effect is augmented, the some residual ADRs persist. Consequently, a G protein biased ${\mu}$ opioid ligand, oliceridine, improves the therapeutic index owing to increased analgesia with decreased adverse events. This review article provides a brief history, mechanism of action, pharmacokinetics, pharmacodynamics, and ADRs of oliceridine.

Review on the Occurrence and Studies of Potato Viral Diseases in Korea (한국에서의 감자 바이러스병 발생과 그 연구에 대한 고찰)

  • Hahm, Young-Il
    • Research in Plant Disease
    • /
    • v.9 no.1
    • /
    • pp.1-9
    • /
    • 2003
  • The occurrence of potato(Sotanum tuberosum) viral diseases caused by Potato virus X(PVX), Potato virus Y (PVY), Potato leafroll virus(PLRV), Potato vims S(PVS), Potato virus M(PVM), Potato virus A(PVA), Potato virus T(PVT), Alfalfa mosic virus(AIMV), Tobacco mosic virus(TMV), Potato mop top virus(PMTV) Tobacco rattle virus(TRV) and Potato spindle tuber viroid(PSTVd), potato witches' broom phytoplasma, have been identified so far in Korea. Major viral diseases such as PVX, PVY and PLRV had been studied more deeply, however, the others are just identified and only partially characterized since the first study on the relation between PVX nucleic acid and virus protein by Kim in 1961. The most studies on potato viral diseases are mainly focused on the problems of seed potato production. The National Alpine Agricultural Experiment Station(NAAES), since it began its activities in 1961, has given special attention to this problem by doing studies to identify, characterize and control potato virus diseases. This effort resulted in the development of new potato virus detection methods as a basis for elaborating new method of control, such as the production of seed potato free of virus and the selection of new virus-resistant transgenic potatoes. The further studies of potato viral diseases required would be fallowings: the continuous monitoring for the occurrence of identified or not identified potato viruses in Korea, the isolation of resistant viral genes, the development of control method for the non-persistently transmitted viruses like PVY, special vectors such as nematode and fungus transmitted viruses, TRV and PMTV and the development of control methods against potato viral diseases by viral cross protection, therapy, transgenic plant, and the use of the agents or molecules, such as virus inhibitors and antiviral proteins, etc., blocking viral replication.

HY Simplified Synthetic Test Facility (한양대학교 간이차단 합성시험설비구축)

  • Chang, Yong-Moo;Hwang, Ryul;Kim, Cheol-Ho;Lee, Bang-Wook;Koo, Ja-Yoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.220-220
    • /
    • 2009
  • We are developing of the evaluation technique and system for testing the performance of circuit breaker using Simplified Synthetic circuit. This facility specification is up to 90[kApeak] and up to 300[kVpeak]. It is possible to verify the interrupting capability by using low-energy and reduce the development period and the cost.

  • PDF

Goodness of Fit Testing for Exponential Distribution in Step-Stress Accelerated Life Testing (계단충격가속수명시험에서의 지수분포에 대한 적합도검정)

  • Jo, Geon-Ho
    • Journal of the Korean Data and Information Science Society
    • /
    • v.5 no.2
    • /
    • pp.75-85
    • /
    • 1994
  • In this paper, I introduce the goodness-of-fit test statistics for exponential distribution using accelerated life test data. The ALT lifetime data were obtained by assuming step-stress ALT model, specially TRV model introduced by DeGroot and Goel(1979). The critical values are obtained for proposed test statistics, Kolmogorov-Smirnov, Kuiper, Watson, Cramer-von Mises, Anderson-Darling type, under various sample sizes and significance levels. The powers of the five test statistic are compared through Monte-Cairo simulation technique.

  • PDF

Transient Recovery Voltage Analysis of industrial customer (대규모 수용가의 차단기 과도회복전압 해석)

  • Shin, Byoung-Yoon;Lee, Han-Sang;Jang, Gil-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.320-321
    • /
    • 2011
  • As the scale of industries expands, the facilities of the industrial customer become larger and more complex. When a fault occurs in the system, the circuit breakers play an important role in minimizing causalitites by quickly tripping the faulted line. Since the capacity of the receiving-end has increased in size, an examination is needed to be performed between the industrial customers and the conventional circuit breakers. The transient recovery voltage, which is the initial transient characteristics of the voltage across the breaker when tripped, is an important factor in determining the circuit breaker's performance. In this paper, a TRV analysis on the large-scale industrial customer is being performed utilizing PSCAD/EMTDC.

  • PDF

The Influence of Current Limit Reactor installed in 345kV power systems on Transient Recovery Voltage (345kV 포스코파워~서인천S/S간 한류리액터 설치에 따른 차단기 과도회복전압 검토)

  • Ryu, Hee-Young;Hur, Youn;Park, Soon-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.222-223
    • /
    • 2011
  • 본 논문은 인천지역 345kV 계통고장전류 저감을 위한 한류리액터 설치에 따른 362kV 50kA 차단기의 과도회복 전압 정격 초과 여부를 EMTP을 활용하여 검토하였다. 과도회복전압(TRV : Transient Recovery Voltage)은 크게 두가지, 최대전압(Vp)과 초기과도회복전압상승율(RRRV:Rate of Rise of Recovery Voltage)로 구분하며, 리액턴스 성분이 증가하며 RRRV가 상승하여 차단기가 고장전류을 차단시 절연파괴(열파괴)로 이어질 수 있다. IEC 62271-100 규정에는 RRRV를 정격차단전류의 100% 크기(T100%) 차단시 2kV/us이내로 규정하고 있으며 이 보다 작은 전류의 T90, T75 차단시의 규정치는 계산식에 의해 정해진다.

  • PDF