• 제목/요약/키워드: TRV

검색결과 61건 처리시간 0.03초

EMTP/RV를 이용한 22.9kV GIS 모델링과 과도회복전압 해석 (22.9kV GIS Modeling and Transient Recovery Voltage Analysis Using EMTP/RV)

  • 정태영;백영식;정기석;박지호;서규석
    • 전기학회논문지
    • /
    • 제59권7호
    • /
    • pp.1199-1205
    • /
    • 2010
  • The recent power system is required to a large size of facilities and high power technology according to increasing power demand. However, it could lead to spoiling the beauty of city and environment problem. The miniaturized facilities with large capacity such as GIS have been required in recent power system. The GIS(Gas Insulated Substation) using the SF6 insulation gas enables to miniaturize facilities with large capacity with high insulation performance. However, the substation installed GIS has required to new design model which is different from the conventional substation. The TRV(Transient Recovery Voltage) analysis on simple circuit may applied by differential equation. However, in case of relatively complicated system, EMTP(Electro Magnetic Transients Program) mainly has been used to design and simulate for transient analysis. This paper mainly design the 22.9 kV GIS system and analyze the transient recovery voltage of main circuit breaker using EMTP/RV. It also enables to easily design the other substation installed GIS with same maker and voltage level because the proposed GIS model consists of separated modules such as busbar, circuit breaker, bushing, CT, PT etc. Eventually, it contributes to comfortably compare the interrupting performance of circuit breaker and system TRV corresponding to the substation system configuration.

2점절 차단기 균압용 콘덴서 절연파괴 고장 메커니즘 및 성능검증 방법에 관한 연구 (Study on the Performance Verification Method and Failure Mechanism of Grading Capacitor of a Two-break Circuit-breaker)

  • 오승열;한기선;김태균
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권1호
    • /
    • pp.11-15
    • /
    • 2019
  • 최근 송전전압 격상으로 인해 차단기 또한 정격이 높아지고 있다. 이에 차단부의 전압 정격을 높이기 위한 방법으로 차단부 2개 이상을 직렬로 구성하는 다점절 차단기가 설치되어 운용되고 있다. 다점절 차단기에서 차단부 극간에 설치되는 균압용 콘덴서는 점절간 균등한 전압분배와 초기 과도회복전압을 저감하는 기능을 수행한다. 하지만, 세계적으로 실계통 사용에서 균압용 콘덴서는 기계적인 손상, 절연파괴에 의한 폭발 등 다수의 고장이 발생하고 있어, 이에 대한 원인 규명과 새로운 성능 검증방법에 대한 연구 필요성이 제기 되고 있다. 본 논문에서는 한전 계통에서 주로 발생한 균압용 콘덴서의 절연파괴 원인을 규명하고 이에 대한 제품 성능검증 방법을 제안하고자 한다.

Optimal Plan of Partially Accelerated Life Tests under Type I Censoring

  • Moon, Gyoung-Ae
    • Journal of the Korean Data and Information Science Society
    • /
    • 제5권2호
    • /
    • pp.87-94
    • /
    • 1994
  • In this paper, we consider optimum plan to determine stress change times under the three-step stress PALTs, assuming that each test units follows an exponential distribution. The tampered random variable(TRV) model for the three-step stress PALTs setup are introduced, and maximum likelihood estimators(MLEs) of the failure rate and the acceleration factors are obtained. The change times to minimize the generalized asymptotic variance(GAVR) of MLEs of the failure rate and the acceleration factors are proposed for the three-step stress PALTs.

  • PDF

Can oliceridine (TRV130), an ideal novel µ receptor G protein pathway selective (µ-GPS) modulator, provide analgesia without opioid-related adverse reactions?

  • Ok, Hwoe Gyeong;Kim, Su Young;Lee, Su Jung;Kim, Tae Kyun;Huh, Billy K;Kim, Kyung Hoon
    • The Korean Journal of Pain
    • /
    • 제31권2호
    • /
    • pp.73-79
    • /
    • 2018
  • All drugs have both favorable therapeutic and untoward adverse effects. Conventional opioid analgesics possess both analgesia and adverse reactions, such as nausea, vomiting, and respiratory depression. The opioid ligand binds to ${\mu}$ opioid receptor and non-selectively activates two intracellular signaling pathways: the G protein pathway induce analgesia, while the ${\beta}$-arrestin pathway is responsible for the opioid-related adverse reactions. An ideal opioid should activate the G protein pathway while deactivating the ${\beta}$-arrestin pathway. Oliceridine (TRV130) has a novel characteristic mechanism on the action of the ${\mu}$ receptor G protein pathway selective (${\mu}$-GPS) modulation. Even though adverse reactions (ADRs) are significantly attenuated, while the analgesic effect is augmented, the some residual ADRs persist. Consequently, a G protein biased ${\mu}$ opioid ligand, oliceridine, improves the therapeutic index owing to increased analgesia with decreased adverse events. This review article provides a brief history, mechanism of action, pharmacokinetics, pharmacodynamics, and ADRs of oliceridine.

한국에서의 감자 바이러스병 발생과 그 연구에 대한 고찰 (Review on the Occurrence and Studies of Potato Viral Diseases in Korea)

  • 함영일
    • 식물병연구
    • /
    • 제9권1호
    • /
    • pp.1-9
    • /
    • 2003
  • The occurrence of potato(Sotanum tuberosum) viral diseases caused by Potato virus X(PVX), Potato virus Y (PVY), Potato leafroll virus(PLRV), Potato vims S(PVS), Potato virus M(PVM), Potato virus A(PVA), Potato virus T(PVT), Alfalfa mosic virus(AIMV), Tobacco mosic virus(TMV), Potato mop top virus(PMTV) Tobacco rattle virus(TRV) and Potato spindle tuber viroid(PSTVd), potato witches' broom phytoplasma, have been identified so far in Korea. Major viral diseases such as PVX, PVY and PLRV had been studied more deeply, however, the others are just identified and only partially characterized since the first study on the relation between PVX nucleic acid and virus protein by Kim in 1961. The most studies on potato viral diseases are mainly focused on the problems of seed potato production. The National Alpine Agricultural Experiment Station(NAAES), since it began its activities in 1961, has given special attention to this problem by doing studies to identify, characterize and control potato virus diseases. This effort resulted in the development of new potato virus detection methods as a basis for elaborating new method of control, such as the production of seed potato free of virus and the selection of new virus-resistant transgenic potatoes. The further studies of potato viral diseases required would be fallowings: the continuous monitoring for the occurrence of identified or not identified potato viruses in Korea, the isolation of resistant viral genes, the development of control method for the non-persistently transmitted viruses like PVY, special vectors such as nematode and fungus transmitted viruses, TRV and PMTV and the development of control methods against potato viral diseases by viral cross protection, therapy, transgenic plant, and the use of the agents or molecules, such as virus inhibitors and antiviral proteins, etc., blocking viral replication.

한양대학교 간이차단 합성시험설비구축 (HY Simplified Synthetic Test Facility)

  • 장용무;황률;김철호;이방욱;구자윤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.220-220
    • /
    • 2009
  • We are developing of the evaluation technique and system for testing the performance of circuit breaker using Simplified Synthetic circuit. This facility specification is up to 90[kApeak] and up to 300[kVpeak]. It is possible to verify the interrupting capability by using low-energy and reduce the development period and the cost.

  • PDF

계단충격가속수명시험에서의 지수분포에 대한 적합도검정 (Goodness of Fit Testing for Exponential Distribution in Step-Stress Accelerated Life Testing)

  • 조건호
    • Journal of the Korean Data and Information Science Society
    • /
    • 제5권2호
    • /
    • pp.75-85
    • /
    • 1994
  • 계단 충격 가속수명시험에서 통계적 추론을 위해 가정하는 수명분포에 대한 적합도검정을 Kolmogorov-Smirnov, Kuiper, Watson, Cramer-von Mises, Anderson-Darling과 같은 비모수적 검정통계량에 대하여 몬테칼로 방법을 이용한 기각치를 구하고, 검정력 측면에서 비교, 연구한다.

  • PDF

대규모 수용가의 차단기 과도회복전압 해석 (Transient Recovery Voltage Analysis of industrial customer)

  • 신병윤;이한상;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.320-321
    • /
    • 2011
  • As the scale of industries expands, the facilities of the industrial customer become larger and more complex. When a fault occurs in the system, the circuit breakers play an important role in minimizing causalitites by quickly tripping the faulted line. Since the capacity of the receiving-end has increased in size, an examination is needed to be performed between the industrial customers and the conventional circuit breakers. The transient recovery voltage, which is the initial transient characteristics of the voltage across the breaker when tripped, is an important factor in determining the circuit breaker's performance. In this paper, a TRV analysis on the large-scale industrial customer is being performed utilizing PSCAD/EMTDC.

  • PDF

345kV 포스코파워~서인천S/S간 한류리액터 설치에 따른 차단기 과도회복전압 검토 (The Influence of Current Limit Reactor installed in 345kV power systems on Transient Recovery Voltage)

  • 유희영;허연;박순규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.222-223
    • /
    • 2011
  • 본 논문은 인천지역 345kV 계통고장전류 저감을 위한 한류리액터 설치에 따른 362kV 50kA 차단기의 과도회복 전압 정격 초과 여부를 EMTP을 활용하여 검토하였다. 과도회복전압(TRV : Transient Recovery Voltage)은 크게 두가지, 최대전압(Vp)과 초기과도회복전압상승율(RRRV:Rate of Rise of Recovery Voltage)로 구분하며, 리액턴스 성분이 증가하며 RRRV가 상승하여 차단기가 고장전류을 차단시 절연파괴(열파괴)로 이어질 수 있다. IEC 62271-100 규정에는 RRRV를 정격차단전류의 100% 크기(T100%) 차단시 2kV/us이내로 규정하고 있으며 이 보다 작은 전류의 T90, T75 차단시의 규정치는 계산식에 의해 정해진다.

  • PDF