• Title/Summary/Keyword: TRS-398 프로토콜

Search Result 15, Processing Time 0.027 seconds

Application of IAEA TRS-398 Protocol to Gamma Knife Model C (감마나이프 C모델에 대한 IAEA TRS-398 프로토콜의 적용)

  • Chung, Hyun-Tai
    • Progress in Medical Physics
    • /
    • v.18 no.4
    • /
    • pp.194-201
    • /
    • 2007
  • Although Gamma Knife irradiates much more radiation in a single session than conventional radiotherapy, there were only a few studies to measure absolute dose of a Gamma Knife. Especially, there is no report of application of International Atomic Energy Agency (IAEA) TRS-398 which requires to use a water phantom in radiation measurement to Gamma Knife. In this article, the authors reported results of the experiments to measure the absorbed dose to water of a Gamma Knife Model C using the IAEA TRS-398 protocol. The absorbed dose to water of a Gamma Knife model C was measured using a water phantom under conditions as close as possible to the IAEA TRS-398 protocol. The obtained results were compared with values measured using the plastic phantom provided by the Gamma Knife manufacturer. Two Capintec PR-05P mini-chambers and a PTW UNIDOS electrometer were used in measurements. The absorbed dose to water of a Gamma Knife model C inside the water phantom was 1.38% larger than that of the plastic phantom. The current protocol provided by the manufacturer has an intrinsic error stems from the fact that a plastic phantom is used instead of a water phantom. In conclusion, it is not possible to fully apply IAEA TRS-398 to measurement of absorbed dose of a Gamma Knife. Instead, it can be a practical choice to build a new protocol for Gamma Knife or to provide a conversion factor from a water phantom to the plastic phantom. The conversion factor can be obtained in one or two standard laboratories.

  • PDF

Direct Calculation of TRS-398 Quality Correction Factors for High Energy Photons (고에너지 광자선에 대한 TRS-398 선질보정인자의 직접 계산)

  • Shin Kyo-Chul;Oh Young-Kee;Kim Jeung-Kee;Kim Jhin-Kee;Kim Ki-Hwan;Jeong Dong-Hyeok
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.54-60
    • /
    • 2006
  • In order to apply the TRS-398 dosimetry protocol developed by IAEA we directly calculated the quality correction factors for high energy photons. The calculations were peformed for seven commercial cylindrical chambers (A12, IC70, N23333, N30001, N30006, NE2571, PR06C/G). In comparison with quality correction factors given by TRS-398 our results were in good agreement within ${\pm}0.3%$ (maximum ${\pm}0.3%$) for all chambers and photon qualities.

  • PDF

Determination of TRS-398 Quality Factors for Cs-137 Gamma Rays in Reference Dosimetry (Cs-137 감마선의 선량측정을 위한 TRS-398 선질인자 결정에 관한 연구)

  • Kang, Sang Koo;Rhee, Dong Joo;Kang, Yeong Rok;Kim, Jeung Kee;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.123-127
    • /
    • 2014
  • The Cs-137 irradiator is widely used to irradiate biological samples for radiobiological research. To obtain the accurate outcomes, correct measurements of the delivered absorbed dose to a sample is important. The IAEA protocols such as TRS-277 and TRS-398 were recommended for the Cs-137 reference dosimetry. However in TRS-398 protocol, currently known as the most practical dosimetry protocol, the quality factor ($k_{Q,Q_0}$) for Cs-137 gamma rays is not suggested. Therefore, the use of TRS-398 protocol is currently unavailable for the Cs-137 dosimetry directly. The calculation method previously introduced for high energy photon beams in radiotherapy was used for deriving the Cs-137 beam qualities ($k_{Q,Q_0}$) for the 15 commercially available farmer type ionization chambers in this study. In conclusion, $k_{Q,Q_0}$ values were ranged from 0.998 to 1.002 for Cs-137 gamma rays. These results can be used as the reference and dosimeter calibrations for Cs-137 gamma rays in the future radiobiological researches.

Study on the Evaluation of TRS-398 Quality Factors with Central Electrode Corrections for Small Cylindrical Chambers (소형 전리함에 대한 TRS-398 선질인자 계산과 중심전극 보정에 관한 연구)

  • Kang, Yeong-Rok;Lee, Chang-Yeol;Kim, Jin-Ho;Moon, Young-Min;Kwak, Dong-Won;Kang, Sang-Koo;Kim, Jeung-Kee;Yang, Kwang-Mo;Jeong, Dong-Hyeok
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.148-154
    • /
    • 2011
  • The quality factors ($k_{Q,Q_0}$) were evaluated by appling the results recently studied for the effect of central electrode in TRS-398 protocol. The PTW-31010 and IBA-CC13 chambers were used in this study. The quality factors were calculated as a function of beam quality for high energy electron and photon beams and compared with data currently used in TRS-398 protocol. In the PTW-31010 chamber using aluminium electrode, appling the new central electrode collections, the quality factors were 0.4% and 0.9% higher than current TRS-398 data for high energy photon and electron beams respectively. In the IBA-CC13 chamber using C-552 electrode, there are no variations in quality factors compared to TRS-398 data currently used.

Comparison of Air Kerma­based and Absorbed Dose to Water­based Protocols in the Dosimetry of High Energy Electron Beams (고 에너지 전자선에 대한 공기커마와 물 흡수선량에 기반한 프로토콜간의 비교)

  • 박창현;신동오;박성용
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.249-258
    • /
    • 2003
  • A few years ago, a proposal was made to change the dosimetry from the air kerma-based reference dosimetry to the absorbed dose-based reference dosimetry for all radiotherapy beams of ionizing radiation to improve the accuracy of dosimetry. Here, we present a dosimetry study in which the two most widespread absorbed dose­based protocols (IAEA TRS­398 and AAPM TG­51) were compared with an air kerma­based protocol (IAEA TRS-277) by measuring the absorbed dose in the same reference depth. Measurements were performed in three clinical electron beam energies using a PTW 30002 cylindrical chamber, and Markus and Roos plane­parallel chambers. $^{60}$ Co calibration factors were obtained from the KFDA. The absorbed dose differences between the air kerma­based and absorbed dose­based protocols were within 2.0% for all chambers in all beams. The results thus show that the obtained absolute dose values will be not significantly altered by changing from the air kerma­based dosimetry to the absorbed dose­based dosimetry. It was also shown that absorbed dose values between the absorbed dose­based protocols agreed by deviations of less than 0.5% for a cylindrical chamber and less than 0.7% for plane­parallel chambers using cross­calibration factors. Although the use of a cylindrical chamber and plane­parallel chambers resulted in a difference of less than 2% for all situations investigated here, to reduce errors, the plane­parallel chambers are recommended for electron energies in which the use of cylindrical chamber is not permitted in each protocol.

  • PDF

Determination of Quality Correction Factors for a Plane-Parallel Chamber in High Energy Electron Beams using Monte Carlo Calculation (몬테칼로 계산을 이용한 평판형 전리함의 고에너지 전자선에 대한 선질보정인자 결정)

  • Jeong, Dong-Hyeok;Lee, Jeong-Ok
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.89-95
    • /
    • 2008
  • The quality correction factor for used beam and qualities is strongly required for clinical dosimetry by TRS-398 protocol of IAEA. In this study the quality correction factors for a commercial plane-parallel ionization chamber in high energy electron beams were calculated by Monte Carlo code(DOSRZnrc/EGSnrc). In comparison of quality correction factor, the difference between this study and TRS-398 were within 1% in 5-20 MeV. In case of 4MeV the difference was 1.9%. As an independent method of determination of quality correction factor this study can be applied to evaluate values in the protocol or calculate the factor for a new chamber.

  • PDF

Determination of Beam Quality Correction Factors for the PTW-Markus Chamber for Electron Beam Qualities R50=1.0 and 1.4 g/cm2 (전자선 선질 R50=1.0과 1.4 g/cm2에 대한 PTW-Markus 전리함의 선질보정인자 결정에 관한 연구)

  • Kim, Me Young;Rhee, Dong Joo;Moon, Young Min;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.178-184
    • /
    • 2015
  • The Markus ionization chamber(R) is a small plane parallel ionization chamber widely used in clinical electron beam dosimetry. Plane parallel chambers were recommended for low energy electron dosimetry with the beam quality at $R_{50}<4.0g/cm^2$ (${\bar{E}}{\approx}10MeV$) according to TRS-398 protocol. However, the quality correction factors ($k_{Q,Q_0}$) of the Markus chamber was not presented in TRS-398 protocol for electron beam quality at $R_{50}<2.0g/cm^2$ (${\bar{E}}{\approx}4MeV$). In this study, the $k_{Q,Q_0}$ factors of the Markus chambers (PTW-34045) for beam qualities at $R_{50}=1.0$, 1.4, 2.0, 2.5, 3.0, and $5.0g/cm^2$ were determined by Monte Carlo calculations (DOSRZnrc/EGSnrc) and the dosimetric formalism of quality correction factor. The derived $k_{Q,Q_0}$ values were evaluated using the produced data based on TRS-398 and TG-51 protocols and known values for the Markus chamber.

평행평판형이온함을 이용한 전자선 흡수선량결정에 대한 연구

  • Ra, Jeong-Eun;Seo, Tae-Seok;Sin, Dong-O
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.149-152
    • /
    • 2004
  • 물 흡수선량 표준에 토대를 두고 있는 프로토콜에서는 저에너지 전자선의 경우 평행평판형이온함의 사용과 기준 선질 $^{60}$CO 감마선의 물 흡수선량 교정정수를 받은 원통형이온함을 사용하여 고에너지 전자선에서 평행평판형이온함을 교차교정하도록 권고하고 있다. 따라서 본 연구에서는 국제원자력기구의 프로토콜(IAEA TRS-398)에서 권고하고 있는 절차에 따라 저에너지 전자선에 대한 원통형이온함의 선질보정정수를 계산하고, 원통형이온함과 평행평판형이온함의 교정방법에 따른 흡수선량을 상호 비교하였다. 그 결과 전자선에너지 10 MeV 이상에서는 두 이온함간의 선량이 잘 일치하였으나 전자선에너지 6, 9 MeV에서 최대 3.3%까지 선량 차이를 보여 저에너지 전자선에서는 반드시 평형판판형이온함의 사용하여 선량측정 할 것을 권고한다. 교정방법 차이에 의한 평행평판형이온함의 선량은 서로 잘 일치하는 것으로 나타나 표준기관에서 직접 교정받은 $^{60}$Co 감마선의 물 흡수선량교정정수를 사용하여 전자선 물 흡수선량을 결정해도 큰 영향은 없을 듯하다. 또한 평행평판형이온함을 교차 교정하기 위한 전자선 에너지에 따른 흡수선량을 상호 비교한 결과 20MeV이외 12, 16 MeV의 전자선 에너지에서도 잘 일치하여 교차교정을 위한 전자선의 기준 선질에 대한 연구가 더 진행되어야 한다고 사료된다.

  • PDF

Measurement of Electron Beam Output for the Prototype Compact Linac (콤팩트 전자 선형가속기 시작품의 출력측정에 관한 연구)

  • Kim, Sung-Woo;Kang, Sang Koo;Rhee, Dong Joo;Lim, Heuijin;Lee, Manwoo;Yi, Jungyu;Lee, Mujin;Yang, Kwangmo;Ro, Tae Ik;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.1-5
    • /
    • 2015
  • The C-band compact linear accelerator (linac) is being developed at Dongnam Institute of radiological & Medical Sciences (DIRAMS) for medical and industrial applications. This paper was focused on the output measurement of the electron beam generated from the prototype electron linac. The dose rate was measured in unit of cGy/min per unit pulse frequency according to the IAEA TRS-398 protocol. Exradin-A10 Markus type plane parallel chamber used for the measurement was calibrated in terms of dose to water at the reference depth in water. The beam quality index ($R_{50}$) was determined by the radiochromic film with a solid water phantom approximately due to low energy electrons. As a result, the determined electron beam output was $17.0cGy/(min{\cdot}Hz$. The results were used to monitor the accelerator performance during the development procedure.

A Study on the absorbed dose to water for high energy electron beams using Water equivalency of plastic phantom (고 에너지 전자선에서 물등가 고체팬톰을 이용한 물 흡수선량 측정에 관한 연구)

  • Sin, Dong-Ho;Sin, Dong-Oh;Kim, Sung-Hoon;Park, Sung-Yong;Ji, Young-Hoon;Ahn, Hee-Kyung;Kang, Jin-Oh;Hong, Seong-Eon
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.166-169
    • /
    • 2004
  • In the International Code of Practice for dosimetry TRS-398 published by International Atomic Energy Agency(IAEA), water equivalency plastic phantom may be used under certain circumstances for electron beam dosimetry for beam quality E0${\leq}$ 10 MeV. In this study, Palstic Water$^{TM}$ and Virtual Water$^{TM}$ were evaluated in order to determine fluence scaling factor hpl. Plastic phantom was evaluated for five electron energy from 6 MeV to 20 MeV. From the measured data of Palstic Water$^{TM}$, the fluence scaling factor hpl was found to be average 0.9964 and Virtual Water$^{TM}$ fluence scaling factor was 1.0156.

  • PDF