• Title/Summary/Keyword: TRIGGER

Search Result 1,474, Processing Time 0.022 seconds

Analysis of the Operational Characteristic of a High-Tc Superconducting Power Supply for Charging of the Superconducting Magnet (초전도자석 충전용 고온초전도전원장치의 특성해석)

  • Yun, Yong-Su;Kim, Ho-Min;An, Min-Cheol;Bae, Deok-Gwon;Go, Tae-Guk
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.4
    • /
    • pp.159-164
    • /
    • 2002
  • This paper presents the design and fabrication of a high-Tc superconducting (HTS) power supply for charging of the HTS magnet load, and its characteristics have been analyzed through experiments. HTS power supply consists of two heaters, an electromagnet, a Bi-2223 solenoid and a Bi-2223 pancake magnet load. In this experiment, 331 mH electromagnet and 0.8 A dc heater current were used, and 8.5 sec and 17 sec were used for pumping period. Mechanism of the superconducting switch is used for heater-trigger. In order to measure the pumping-current with respect to the magnet flux changes, hall sensor was installed at the center of the Bi-2223 pancake load. The experimental observations have been compared with the theoretical predictions. In this experiment, the pumping-current has reached about 1.2 A. In computer simulation, the maximum pumping-current of the system has been predicted to be about 2.7 A.

Development of the Crowbar System Using a Vacuum Switch (진공 스위치를 이용한 Crowbar 시스템의 개발)

  • 이태호;허창수;이홍식
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.12
    • /
    • pp.584-590
    • /
    • 2002
  • Crowbar system is usually applied to a pulsed power system in which a capacitor bank is discharged into a load. This provides a free wheeling path for the load current and prevents the capacitor from recharging due to a reverse voltage. Usually diodes have been used as a crowbar switch, but it is not a practical system because the cost of the diodes goes up enormously with increasing the system voltage and current. This paper presents a novel protection scheme of a charging and discharging system of a 300 kJ capacitor bank using a low-cost crowbar system which consists of a crowbar switch and resistors. Triggered vacuum switch(TVS) was used for a crowbar switch, and Rogowski coil was used to determine a trigger time of TVS. When this crowbar system is applied to our pulsed power system which consists of capacitor bank($123muF$), inductor() for forming a pulse, load resistor$(100 m\Omega)$, and a closing switch, instantaneous reversal voltage of capacitor bank could be limited less than 1.8 ㎸ until capacitor bank was charred to 17 ㎸.

A Study on SCR-Based ESD Protection Circuit with PMOS (PMOS가 삽입된 SCR 기반의 ESD 보호 회로에 관한 연구)

  • Kwak, Jae-Chang
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1309-1313
    • /
    • 2019
  • In this paper, the electrical characteristics of Gate grounded NMOS(GGNMOS), Lateral insulated gate bipolar transistor(LIGBT), Silicon Controlled Rectifier(SCR), and Proposed ESD protection device were compared and analyzed. First, the trigger voltage and holding voltage were verified by simulating the I-V characteristic curve for each device. After that, the robustness was confirmed by HBM 4k simulation for each device. As a result of HBM 4k simulation, the maximum temperature of the proposed ESD protection device is lower than that of GGNMOS and GGLIGBT and SCR, which means that the robustness is improved, which means that the ESD protection device is excellent in terms of reliability.

Impact Collapse Characteristics of CF/Epoxy Composite Tubes for Light-Weights

  • Kim, Young-Nam;Hwang, Jae-Jung;Baek, Kyung-Yun;Cha, Cheon-Seok;Yang, In-Young
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.48-56
    • /
    • 2003
  • This paper investigates the collapse characteristics of CF/Epoxy composite tubes subjected to axial loads as changing interlaminar number and outer ply orientation angle. The tubes are aften used for automobiles, aerospace vehicles, trains, ships, and elevators. We have performed static and dynamic impact collapse tests by a way of building impact test machine with vertical air compression. It is fanad that CF/Epoxy tube of the 6 interlaminar number (C-type) with 90$^{\circ}$ outer orientation angle and trigger absorbed more energy than the other tubes (A. B and D-types). Also collapse mode depended upon outer orientation angle of CF/Epoxy tubes and loading type as well; typical collapse modes of CF/Epoxy tubes are wedged, splayed and fragmentcl.

Influence of Stacking Sequence Conditions on the Characteristics of Impact Collapse using CFRP Thin-Wall Structures (CFRP 박육부재의 적층조건이 충격압궤특성에 미치는 영향)

  • Kim, Yeong-Nam;Choe, Hyo-Seok;Cha, Cheon-Seok;Im, Gwang-Hui;Jeong, Jong-An;Yang, In-Yeong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.12
    • /
    • pp.2945-2951
    • /
    • 2000
  • Because of the inherent flexibility in their design for improved material properties, composites have wide applications in aerospace vehicles and automobiles. The purpose of this study is to investigate the energy absorption characteristics of CFRP( Carbon Fiber Reinforced Plastics); tubes on static and impact tests. Static compression tests have been carried out using the static testing machine(Shin-gang buckling testing machine)and impact compression tests have been carried out using the vertival crushing testing machine. When such tubes were subjected to crushing loads, the response is complex and depends on the interaction between the different mechanisms that control the crushing process. The collapse characteristics and energy absorption were examined. Trigger and interlaminar number affect energy absorption capability of CFRP tubes.

Performance Improvement of IP Handover by Data Link Trigger (데이터링크 트리거에 의한 IP 핸드오버 성능 개선)

  • Ki, Jang-Geun;Lee, Kyu-Tae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.55-60
    • /
    • 2016
  • In the traditional wireless LAN model, scan procedure to search a new AP starts when the predefined number of Rx failure of beacon frames are occurred. In this case, lots of data packet loss occur during MN's handover because loss of the relatively longer data packet starts before the small-sized beacon loss. Newly developed scanning mechanism in this paper has the beacon counter that increases when the Rx power level of beacon frame is less than the threshold and the previous rx power level. New scan procedure starts when the counter exceeds the predefined number. Beacon Rx power threshold is verified and performance of the new WLAN model is evaluated under UDP and TCP traffic environment.

A Study on ESD Protection Circuit for 2-Stack Structure Design Based on LVTSCR (LVTSCR 기반의 2-Stack 구조 설계를 위한 ESD 보호회로에 관한 연구)

  • Seo, Jeong-Yun;Do, Kyoung-Il;Chae, Hee-Guk;Seo, Jeong-Ju;Koo, Yong-Seo
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.836-841
    • /
    • 2018
  • In this paper, This paper is based on the conventional ESD protection circuits SCR and LVTSCR. Also, the SCR-based ESD protection circuit, which is different from the conventional structure, is presented and tested for variations in the trigger voltage and holding voltage. Due to the insertion of additional N +, P + regions, the newly added SCR-based protection circuit have improved electrical characteristics. To discuss the electrical characteristics of the proposed circuit, Synopsys T-CAD simulation data was shown.

Manufacture of a Small RTE for Real-Time Extraction of Radar Signal (레이더 신호의 실시간 추출을 위한 소형 레이더 목표 추출기 개발)

  • Sung Tae-Kyung;Kim Dong-Seek;Cho Hyung-Rae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.9
    • /
    • pp.835-840
    • /
    • 2004
  • Using of small Radar device can not supply the real exercise information of ellipse circumference or CPA, TCPA and the changing of surroundings fur various target information. Therefore, for the above problem, we develop RTE that is able to and of for each information from ARPA Radar which supply analog video signal, trigger bearing and heading pulse from low-cost small Radar device is equiped with general small fishing boat. The small fishing is equipped with small Radar device, so it is able to collect and apply sailing information such as real exercise information and TCPA.

Analysis on the Quench Characteristics According to Magnetic Field of the Matrix-Type SFCL with $1{\times}3$ Matrix Structure ($1{\times}3$ 행렬구조를 갖는 매트릭스형 초전도 한류기의 자장유무에 따른 퀜치특성 분석)

  • Oh, Kum-Gom;Cho, Yong-Sun;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.343-348
    • /
    • 2008
  • We investigated the quench characteristics accordance with increase of turns and applied voltage of matrix-type superconducting fault current limiter (SFCL) with $1{\times}3$ matrixes. The matrix-type SFCL consists of the trigger part to apply magnetic field and the current-limiting part to limit fault current. The fault current limiting characteristics according to the increase of magnetic field and applied voltage were nearly same. This is because the application of magnetic field has not an affect on total impedance of SFCL. When number of turns of reactor increased, the voltage difference between two superconducting units in the current-limiting part according was decreased. The resistance difference generated in two superconducting units also was decreased. Therefore, we confirmed that the differences of critical behaviors between superconducting units by application of magnetic field were decreased. By this results, we could be decided the optimum number of turns of reactor to apply magnetic field.

Agent based real-time fault diagnosis simulation (에이젼트기반 실시간 고장진단 시뮬레이션기법)

  • 배용환;이석희;배태용;이형국
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.670-675
    • /
    • 1994
  • Yhis paper describes a fault diagnosis simulation of the Real-Time Multiple Fault Dignosis System (RTMFDS) for forcasting faults in a system and deciding current machine state from signal information. Comparing with other diagnosis system for single fault,the system developed deals with multiple fault diagnosis,comprising two main parts. One is a remotesignal generating and transimission terminal and the other is a host system for fault diagnosis. Signal generator generate the random fault signal and the image information, and send this information to host. Host consists of various modules and agents such as Signal Processing Module(SPM) for sinal preprocessing, Performence Monotoring Module(PMM) for subsystem performance monitoring, Trigger Module(TM) for multi-triggering subsystem fault diagnosis, Subsystem Fault Diagnosis Agent(SFDA) for receiving trigger signal, formulating subsystem fault D\ulcornerB and initiating diagnosis, Fault Diagnosis Module(FDM) for simulating component fault with Hierarchical Artificial Neural Network (HANN), numerical models and Hofield network,Result Agent(RA) for receiving simulation result and sending to Treatment solver and Graphic Agent(GA). Each agent represents a separate process in UNIX operating system, information exchange and cooperation between agents was doen by IPC(Inter Process Communication : message queue, semaphore, signal, pipe). Numerical models are used to deseribe structure, function and behavior of total system, subsystems and their components. Hierarchical data structure for diagnosing the fault system is implemented by HANN. Signal generation and transmittion was performed on PC. As a host, SUN workstation with X-Windows(Motif)is used for graphic representation.

  • PDF