• Title/Summary/Keyword: TR-25

Search Result 207, Processing Time 0.033 seconds

Reliability and validity of a personal computer based muscle viewer for measuring upper trapezius and transverses abdominis muscle thickness

  • Jeong, Ju-Ri;Han, Ju Hee;Cho, Ji-Eun;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.3
    • /
    • pp.155-161
    • /
    • 2016
  • Objective: This study aimed to investigate the reliability and validity of a personal computer-based muscle viewer (PC-BMW) compared with that of a portable ultrasound (P-US) for measuring upper trapezius (UT) and transversus abdominis (TrA) muscle thickness at rest and during contraction. Design: Observational inter-rater reliability study. Methods: Fifty-five healthy participants (25 men, 30 women) participated in this study. PC-BMW and P-US were randomly measured at the UT and TrA muscles. Two examiners randomly obtained the images of all participants in 3 test sessions lasting 2 days. Intra-class correlation coefficients (ICCs), standard error of measurement, contraction ratio, and correlation were used to estimate reliability and validity. Pearson's correlation coefficients were used to analyze the relationship between muscle thickness measures taken from PC-BMW and P-US. Results: The intra-rater reliability ICCs of UT and TrA muscle thickness for the PC-BMW were >0.995, indicating excellent reliability. Inter-rater reliability ICCs for the PC-BMW ranged from 0.963 to 0.987. The P-US also exhibited high reliability. A high correlation was found between the measurements of the two muscles in PC-BMW and P-US (p<0.01). Conclusions: PC-BMW provides clear and excellent images, is pocket-sized and less expensive than a conventional ultrasound imaging system. PC-BMW can be utilized variously and has the advantage of rehabilitative ultrasound imaging. More research is needed to evaluate the utility of PC-BMW for rehabilitation.

Clinical experience of open heart surgery -70 cases- (개심술 70예의 임상경험)

  • 조광현
    • Journal of Chest Surgery
    • /
    • v.19 no.4
    • /
    • pp.644-662
    • /
    • 1986
  • Seventy cases of open heart surgery were performed in the department of Thoracic and Cardiovascular Surgery, Pusan Paik Hospital, Inje College, from Oct. 1985 to Oct. 1986. And the results were summarized as follows. 1. Among the 70 cases, there were 48 cases of congenital heart anomalies and 22 cases of acquired rheumatic valvular heart diseases. Age range of the congenital patients was 7 months to 31 years with the mean age of 10 years, and the acquired patients was 18 to 62 years with the mean age of 40 years. 2. The heart-lung machine used for cardiopulmonary bypass was Sarns 7000, 5-head roller pump, and the number and type of oxygenators were 5 of membrane type and 65 of bubble type. For all cases GIK [glucose-insulin-potassium] solution was used as cardioplegic solution for myocardial protection during operation. 3. Among the 48 congenital anomalies, there were 12 cases of ASD group, 29 of VSD group, 3 of ECD, 3 of TOF and one of PDA + MR, and to all of which the appropriate radical operations were applied. 4. Among the 22 acquired valvular diseases, there were 11 cases of mitral valve diseases [MS; 4, MSr; 3, MRs; 4], 3 cases of aortic valve diseases [AR:1, ARs;1, ASr;1], 4 cases of double valve diseases [MRs+TR; 3, MRs+ARs; 1] and 4 cases of triple valve diseases [MSr+ASr+TR; 3, MSr+Ar+TR; 1]. To all the diseased mitral and aortic valves, artificial valve replacement was applied except one [As], in which valve plication was applied. And to all the diseased tricuspid valve, DeVega annuloplasty was applied. 5. The number of replaced artificial valves were 29 in 25 patients [congenital; 3, acquire; 22]. In MVR, 6 of mechanical valves [St. Jude Medical valve; 6] and 15 of tissue valves [Carpentier-Edward valve; 11, lonescu-Shiley valve; 4] were used. In AVR, 6 of mechanical valves [St. Jude Medical valve; 6] and 2 of tissue valves [Carpentier-Edward valve; 2] were used. 6. Postoperative complications were occurred in 12 cases. Among them 11 cases were recovered with intensive cares, but one patient [VSD + Fistula of Valsalva sinus] was expired with low cardiac out put syndrome.

  • PDF

Focal Lesion Detection of SPIO-specific agent Compared with Optimized Pulse Sequences in the Hepatic Metastases: Case Review (간 전이환자에서 최적의 펄스시퀀스에 따른 SPIO 특이성 조영제의 국소병변검출: Case review)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.57-61
    • /
    • 2012
  • To compare the accuracy of breath-hold magnetic resonance imaging sequences to establish the most effective superparamagnetic iron oxide-enhanced sequence for detection of hepatic metastases. A total of 100 patients(50men and 50women, mean age: 60years) with liver disease(including malignant and benign liver lesions) were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) with 8Ch body coil. Pulse sequence for MR imaging decided to the FS-T2-FSE-RT(TR/TE/Thick./Freq./Phase=12857ms/100ms/7mm/512/384), MGRE(TR/TE/Thick./Freq./Phase=100ms/9.7ms/7mm/384/288), in-out of phase echo(TR/$TE_1$, $TE_2$/Thick./Freq./Phase=140ms/2.4, 5.8ms/7mm/352/300), Images obtained before the injection of SPIO. Six sequences were optimized for lesion detection: FS-T2-FSE-RT, multigradient recalled echo data image(MGRE), T2-weighted MGRE with an 9.7msec echo time. Images were reviewed independently by five blinded observers. The accuracy of each sequence was measured by using picture archiving communication system analysis. All results were correlated with findings at multidectator computed tomography examination. Differences between the mean results of the six observers were measured by using paired student t-test analysis. Postcontrast T2-weighted MGRE sequences were the most accurate and were significantly superior to postcontrast FS-T2-FSE-RT, T2-weighted MGRE, in-out of phase MR sequences(p < .05). For all lesions that were malignant or smaller than 1 cm, respectively, contrast to noise ratio of pre and postcontrast sequences were -1and -0.3 for T2-weighted FSE, 0.53 and 4.5 in-out of phase, 7, 7.08, 5.08, 3.32, 1.7, 1.16, 0.79, 0.68 for GRE with 2.9, 7.5, 12.1, 16.6, 21.2, 25.8, 30.4, 35.0 TE values. Breath-hold various TE precontrast sequences offer improvement in sensitivity compared with fixed multigradient recalled echo sequences alone.

  • PDF

The Study on Camparison Problem Behaviors with Self-conception & Mental Health in Adolescence (청소년의 문제행동과 자아개념$\cdot$정신건강 비교분석 - 서울시내 일부 주$\cdot$야간고등학교를 중심으로)

  • Kim Y.H.;Cho K.J.;Cho M.Y.
    • The Korean Nurse
    • /
    • v.25 no.1 s.134
    • /
    • pp.57-84
    • /
    • 1986
  • On the assumption that nurses must take part actively in realizing ''Bright Society'' and ''Welfare Societ:'', I examined and made a Study of the youth''s self-conception and their state of mental health to offer the basic materials to early detection, tr

  • PDF

Quantitative trait loci controlling the amino acid content in rice (Oryza sativa L.)

  • Yoo, Soo-Cheul
    • Journal of Plant Biotechnology
    • /
    • v.44 no.4
    • /
    • pp.349-355
    • /
    • 2017
  • The amino acid composition of rice is a major concern of rice breeders because amino acids are among the most important nutrient components in rice. In this study, a genetic map was constructed with a population of 134 recombinant inbred lines (RILs) from a cross between Dasanbyeo (Tongil-type indica) and TR22183 (temperate japonica), as a means to detect the main and epistatic effect quantitative trait loci (QTLs) for the amino acid content (AAC). Using a linkage map which covered a total of 1458 cM based on 239 molecular marker loci, a total of six main-effect QTLs (M-QTLs) was identified for the content of six amino acids that were mapped onto chromosome 3. For all the M-QTLs, the TR22183 allele increased the trait values. The QTL cluster (flanked by id3015453 and id3016090) on chromosome 3 was associated with the content of five amino acids. The phenotypic variation, explained by the individual QTLs located in this cluster, ranged from 10.2 to 12.4%. In addition, 26 epistatic QTLs (Ep-QTLs) were detected and the 25 loci involved in this interaction were distributed on all nine chromosomes. Both the M-QTLs and Ep-QTLs detected in this study will be useful in breeding programs which target the development of rice with improved amino acid composition.

A Research for Assessment Fire Toxic Gas of Construction Material Using FT-IR and FED (FT-IR과 FED를 이용한 건축 재료의 연소독성평가에 관한 연구)

  • Kim, Sung-Soo;Cho, Nam-Wook;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.27-31
    • /
    • 2011
  • In this study, combustion toxicity evaluation for building interior materials and study for toxicity as using FT-IR analysis. this experiment for the calculation of toxicity index, it using a cone calorimeter model in KS F ISO/TR 9122-4 as a fire model. It is following ISO 19702 procedure for assessing fire toxic gas using FT-IR. This experiment used calculation method for toxicity index (FED) among the international standards. $LC_{50}$ is a concentration that it can cause death to 50 % of experimental animal in 30 minutes - exposure gas test. comparison with the three kinds of toxicity fire gas of construction materials using toxicity index.

Hypoxic Microenvironmental Control of Stress Protein and Erythropoietin Gene Expression

  • Beak, Sun-Hee;Han, Mi-Young;Lee, Seung-Hoon;Choi, Eun-Mi;Park, Young-Mee
    • BMB Reports
    • /
    • v.32 no.2
    • /
    • pp.112-118
    • /
    • 1999
  • The presence of hypoxic cells in solid tumors has long been considered a problem in cancer treatment such as in radiation therapy or treatment with some anticancer drugs. It has been suggested that hypoxic cells are involved in the development of a more aggressive phenotype and contribute to metastasis. In this study, as an attempt to understand how tumor cells adapt to hypoxic stress, we investigated the regulation of the hypoxia-induced expression of proteins that control essential processes of tumor cell survival and angiogenesis. We first examined whether hypoxia induces stress protein gene expression of murine solid tumor RIF cells. We also examined hypoxia-induced changes in angiogenic gene expression in these cells. Finally, we investigated the association of the elevated levels of stress proteins with the regulation of hypoxia-induced angiogenic gene expression. Results demonstrated that hypoxia induced the expression of the erythropoietin (EPO) gene and at least two major members of stress proteins, heat shock protein 70 (HSP70) and 25 (HSP25) in RIF tumor cells. Evidence that the expression of EPO gene was greatly potentiated in TR cells suggested that the elevated levels of HSPs may play an important role in the regulation of the hypoxia-induced EPO gene expression. One of the RIF variant cell lines, TR, displays elevated levels of HSPs constitutively. Taken together, our results suggest that a hypoxic tumor microenvironment may promote the survival and malignant progression of the tumor cells by temporarily increasing the level of stress proteins and expressing angiogenic genes. We suspect that stress proteins may be associated with the increase of the angiogenic potential of tumor cells under hypoxia.

  • PDF

Studies on the Ability to Detect Lesions According to the Changes in the MR Diffusion Weighted Images

  • Kim, Chang-Bok;Cho, Jae-Hwan;Dong, Kyung-Rae;Chung, Woon-Kwan
    • Journal of Magnetics
    • /
    • v.17 no.2
    • /
    • pp.153-157
    • /
    • 2012
  • This study evaluated the ability of Diffusion-Weight Image (DWI), which is one of pulse sequences used in MRI based on the T2 weighted images, to detect samples placed within phantoms according to their size. Two identically sized phantoms, which could be inserted into the breast coil bilaterally, were prepared. Five samples with different sizes were placed in the phantoms, and the T2 weighted images and DWI were obtained. The Breast 2 channel coil of SIEMENS MAGNETOM Avanto 1.5 Tesla equipment was used for the experiments. 2D T2 weighted images were obtained using the following parameters: TR/TE = 6700/74 msec, Thickness/gap = 5/1 mm, Inversion Time (TI) = 130 ms, and matrix = $224{\times}448$. The parameters of DWI were that TR/TE = 8100/90 msec, Thickness/gap = 5/1 mm, matrix = $128{\times}128$, Inversion Time = 185 ms, and b-value = 0, 100, 300, 600, 1000 s/mm. The ratio of the sample volume on DWI compared to the T2 weighted images, which show excellent ability to detect lesions on MR images, was presented as the mean b-value. The measured b-value of the samples was obtained: 0.5${\times}$0.5 cm=0.33/0.34 square ${\times}$ cm (103%), 1${\times}$1 cm=1.28/1.25 square ${\times}$ cm (102.4%), 1.5${\times}$1.5 cm = 2.28/2.67 square ${\times}$ cm (85.39%), 2${\times}$2 cm=3.56/4.08 square ${\times}$ cm (87.25%), and 2.5${\times}$2.5 cm=7.53/8.77 square ${\times}$ cm (85.86%). In conclusion, the detection ability by the size of a sample was measured to be over 85% compared to T2 weighted image, but the detection ability of DWI was relatively lower than that of T2 weighted image.

Interference Investigation between WCDMA TDD System and cdma2000 System by Link-level Simulation and System-level Simulation (링크 레벨 시뮬레이션과 시스템 레벨 시뮬레이션에 의한 WCDMA TDD시스템과 cdma2000시스템 간의 상호간섭분석)

  • 차인석;장경희;김성진;최용석
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.7
    • /
    • pp.21-30
    • /
    • 2004
  • The capacity of WCDMA TDD system is limited mainly by the interference. So, to achieve the expected performance of WCDMA TDD system and to minimize the interference to cdma2000 system interferences, such as interference within WCDMA TDD system inter-cell interference, and interferences between cdma2000 systems, should be considered carefully. In this paper, by using System-level Simulation, we analyzed the interferences between WCDMA TDD system and cdma2000 system in practical situation based on the exact parameters of 3GPP TR 25.942 and by using System-level Simulation considering Link-level we analyze the interferences between WCDMA TDD system and cdam2000 system. From Simulation Results, we propose the condition for optimizing system capacity considering the interferences between WCDMA TDD system & cdam2000 system

Effect of Pressure on Solids Flow Characteristics in Recycle System of a Circulating Fluidized Bed (순환유동층 재순환부 내 고체흐름 특성에 대한 시스템 압력의 영향)

  • Kim, Sung Won;Kim, Sang Done
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.198-204
    • /
    • 2010
  • Solids flow characteristics have been determined in a pressurized solids recycle systems of silica sand particles for the application in a pressurized CFB(PCFB). The solids recycle system is composed of a downcomer(0.10 m i.d. 2.25 m high) and a loop-seal(0.10 m i.d.). The silica sand($d_p=240{\mu}m$, ${\rho}_s=2582kg/m^3$) particles were transported at room temperature and system pressure($P_{sys}$) up to 0.71 MPa using air. Solids mass flux($G_s$) increases with increasing system pressure at constant aeration rate. Pressure gradient, solids velocity and actual gas velocity increase with increasing $P_{sys}$ at constant aeration rate. The Pressure drop number($\Phi$) on pressure gradient in downcomer has been correlated with Transportation number(Tr). Pressure drop across the loop-seal increases with increasing of $G_s$ irrespective of variation of $P_{sys}$. The obtained $G_s$ and Transportation number(Tr) have been correlated with the experimental variables.