• 제목/요약/키워드: TR ratio

검색결과 180건 처리시간 0.028초

Improvement of OPW-TR Algorithm for Compressing GPS Trajectory Data

  • Meng, Qingbin;Yu, Xiaoqiang;Yao, Chunlong;Li, Xu;Li, Peng;Zhao, Xin
    • Journal of Information Processing Systems
    • /
    • 제13권3호
    • /
    • pp.533-545
    • /
    • 2017
  • Massive volumes of GPS trajectory data bring challenges to storage and processing. These issues can be addressed by compression algorithm which can reduce the size of the trajectory data. A key requirement for GPS trajectory compression algorithm is to reduce the size of the trajectory data while minimizing the loss of information. Synchronized Euclidean distance (SED) as an important error measure is adopted by most of the existing algorithms. In order to further reduce the SED error, an improved algorithm for open window time ratio (OPW-TR) called local optimum open window time ratio (LO-OPW-TR) is proposed. In order to make SED error smaller, the anchor points are selected by calculating point's accumulated synchronized Euclidean distance (ASED). A variety of error metrics are used for the algorithm evaluation. The experimental results show that the errors of our algorithm are smaller than the existing algorithms in terms of SED and speed errors under the same compression ratio.

Effects of Lumbar Stabilization Exercise Program with Proprioceptive Stimulation in 20s Female Low Back Pain Patient

  • Baek, Gye-Seong;Park, Sam-Ho;Shin, Won-Seob
    • Physical Therapy Rehabilitation Science
    • /
    • 제11권2호
    • /
    • pp.198-206
    • /
    • 2022
  • Objective: This study was to investigate the effect of a lumbar stabilization exercise program accompanied by proprioceptive stimulation in women in their 20s with low back pain. Design: A randomized controlled trial Methods: A total of 30 women in their 20s with low back pain were selected and randomly assigned to an experimental group and a control group. Both groups performed a lumbar stabilization exercise program, and only the experimental group applied for a stabilization exercise program with proprioceptive stimulation. The exercise program lasted 60 minutes at a time, 3 times a week, for 4 weeks. The measurement tools used were the Numeric Rating Scale (NRS), the Korean version of the Oswestry Disability Index (K-ODI), the lumbar alignment, and the transverse abdominis(TrA) muscle thickness and contraction ratio. Results: Both groups showed statistically significant differences in NRS, K-ODI, and muscle thickness before and after the experiment (p<0.05). The lumbar alignment and contraction ratio at the time of contraction of TrA in the experimental group was statistically significantly increased, and there was also a significant difference in the difference between the two groups (p<0.05). Conclusions: The lumbar stabilization exercise program with proprioceptive stimulation reduced pain, improved low back pain induced dysfunction, and increased TrA muscle thickness and contraction ratio. Therefore, it can be an effective therapeutic exercise program for women in their 20s with LBP.

Effect of Phenyl Vinyl Methyl Silicone (PVMQ) on Low Temperature Sealing Performance of Fluorosilicone Composites

  • Lee, Jin Hyok;Bae, Jong Woo;Choi, Myoung Chan;Yun, Yu-Mi;Jo, Nam-Ju
    • Elastomers and Composites
    • /
    • 제56권4호
    • /
    • pp.209-216
    • /
    • 2021
  • In this study, we observed the mechanical properties, thermal stability, and low temperature sealing performance of fluorosilicone elastic composites. When the blend ratio of Phenyl vinyl methyl silicone (PVMQ) was increased, the tensile strength, modulus at 100%, and compression set were decreased. The thermal stability of fluorosilicone elastic composites showed a similar tendency. These were caused by poorer green strength of PVMQ than Fluorosilicone rubber (FVMQ). The change in the tensile strength and elongation at -40℃ showed a decreasing tendency with increasing PVMQ blend ratio. By increasing the PVMQ blend ratio, low-temperature performance was improved. The Dynamic mechanical analysis (DMA) results showed that Tg was decreased and low-temperature performance was improved with increasing PVMQ blend ratio. However tanδ was decreased becaused of the poor green strength and elasticity of PVMQ. From a hysteresis loss at -40℃, the hysteresis loss value was increased and fluorosilicone elastic composites showed the decreasing tendency of elasticity with increasing PVMQ blend ratio. From the TR test, TR10 was decreased with increasing PVMQ blend ratio. FS-4 (45% PVMQ blended composites) showed a TR10 of -68.0℃ that was 5℃ lower than that of FS-1 (100% FVMQ). The gas leakage temperature was decreased with increasing PVMQ blend ratio. The gas leakage temperature of FS-4 was -69.2℃ that was 5℃ lower than that of FS-1. Caused by the polymer chain started to transfer from a glassy state to a rubbery state and had a mobility of chain under Tg, the gas leakage temperature showed a lower value than Tg. The sealing performance at low temperature was dominated by Tg that directly affected the mobility of the polymer chain.

스마트 무인기 TR-S2 형상의 정적 풍동시험 (Static Wind Tunnel Test of Smart Un-manned Aerial Vehicle(SUAV) for TR-S2 Configuration)

  • 최성욱;조태환;정진덕
    • 대한기계학회논문집B
    • /
    • 제29권6호
    • /
    • pp.755-762
    • /
    • 2005
  • To evaluate the aerodynamic efficiency of TR-S2 configuration designed by SUDC, wind tunnel tests of $40\%$ scaled model were done in KARI LSWT. The aerodynamic characteristics of plain and Semi-Slotted Flaperon were compared, and vortex generators were installed to improve flow pattern along the wing surface. Effects of the control surface such as elevator, rudder, aileron, and incidence angle of horizontal tail are measured for various testing conditions. Test results showed that Semi-Slotted Flaperon produced more favorable lift, lift/drag, and stall margins and application of vortex generator would be best choice to enhance wing performance. Longitudinal, lateral and directional characteristics of TR-S2 were found to be stable for the pitch and yaw motions.

Langmuir-Blodgett 법을 이용한 P(VDF-TrFE) 박막 트랜지스터 (P(VDF-TrFE) Thin Film Transistors using Langmuir-Blodgett Method)

  • 김광호
    • 반도체디스플레이기술학회지
    • /
    • 제19권2호
    • /
    • pp.72-76
    • /
    • 2020
  • The author demonstrated organic ferroelectric thin-film transistors with ferroelectric materials of P(VDF-TrFE) and an amorphous oxide semiconducting In-Ga-Zn-O channel on the silicon substrates. The organic ferroelectric layers were deposited on an oxide semiconductor layer by Langmuir-Blodgett method and then annealed at 128℃ for 30min. The carrier mobility and current on/off ratio of the memory transistors showed 9 ㎠V-1s-1 and 6 orders of magnitude, respectively. We can conclude from the obtained results that proposed memory transistors were quite suitable to realize flexible and werable electronic applications.

Quantification of Pediatric Cervical Growth : Anatomical Changes in the Sub-Axial Spine

  • Lee, Ho Jin;Lee, Jung Jae;Hong, Jae Taek;Kim, Jong Tae
    • Journal of Korean Neurosurgical Society
    • /
    • 제57권3호
    • /
    • pp.185-191
    • /
    • 2015
  • Objective : In order to provide normal values of the pediatric sub-axial cervical spinal canal and vertebral body growth pattern using computed tomographic scans, a total of 318 patients less than 10 years old were included. Methods : The growth of the vertebral body and canal space was investigated using four different age groups. The Torg ratio (TR) was calculated and all patients were classified into a low TR group and a high TR group according to a cutoff value of 1.0. To account for spinal curvature, the C3-7 angle was measured. Results : Very little axial expansion and growth in height were observed (2.9 mm and 3.4 mm, respectively), and the spinal canal increments (1.8 mm) were much smaller than the dimensions of the vertebral body. The mean TR values were $1.03{\pm}0.14$ at the C3 vertebral level, $1.02{\pm}0.13$ at C4, $1.05{\pm}0.13$ at C5, $1.04{\pm}0.13$ at C6, and $1.02{\pm}0.12$ at C7 in all patients. The mean sub-axial angle (C3-7) was $7.9{\pm}10.6^{\circ}$ (range: $-17-47^{\circ}$). Conclusion : The upper sub-axial spinal canal continuously increased in size compared to the lower sub-axial spine after 8 years of age. Considerable decrements in the TR was found after late childhood compared to younger ages. Generally, there were no significant differences between boys and girls in vertical length of the cervical vertebrae. However, the axial dimension of the vertebral body and the spinal canal space varied according to gender.

Immediate Effects of Pulsed Magnetic Field in Subjects with Upper Trapezius Trigger Point

  • Kang, Sun-Young;Park, Joo-Hee;Song, Ja-Eik;Jeon, Hye-Seon;Lee, Hyun Sook
    • The Journal of Korean Physical Therapy
    • /
    • 제26권6호
    • /
    • pp.379-385
    • /
    • 2014
  • Purpose: This study was to determine the immediate effects of pulsed magnetic field (PMF) in subjects with upper trapezius (UT) trigger point (TrP). Methods: Fifteen subjects with UT TrP were recruited for the study's PMF group (pain threshold=$2.29kg/cm^2$), and 15 age-, weight-, and gender-matched subjects with UT TrP were recruited for control group (pain threshold=$2.25kg/cm^2$). Pressure algometer was used to measure pressure pain threshold on UT TrP and, cervical range of motion (ROM) inclinometer was used to measure cervical ROM. Surface electromyography was used to record UT, lower trapezius, and serratus anterior muscle activity and relative ratio during scapular plane abduction between pre- and post-treatment. Results: The PMF effectively improved pain threshold and concurrently increased ROM (rotation to the painful side, lateral flexion to the nonpainful side). In addition, the PMF may effectively deactivate UT activity during abduction and the muscle activity ratio between UT and serratus anterior. Conclusion: These findings provided empirical evidence that PMF can be an effective treatment method to reduce pain threshold, to increase cervical ROM, and deactivate UT activity in individuals with TrP.

초음파 영상을 통한 뇌졸중 환자의 외측복부근 근수축의 비대칭성 연구 (The Study of Asymmetrical Contraction of the Lateral Abdominal Muscles in Stroke Patients Using Ultrasound Imaging)

  • 박현주;오덕원;신원섭
    • 대한물리의학회지
    • /
    • 제7권3호
    • /
    • pp.319-327
    • /
    • 2012
  • Purpose : This study aimed to identify the asymmetry observed in the rehabilitative ultrasound imaging of lateral abdominal muscle thickness and performance between the affected and unaffected side during the abdominal drawing-in maneuver (ADIM), an exercise used to facilitate activation of selectively TrA to stabilize the trunk prior to limb movement. Methods : The Participants were twenty one patients with post-stroke hemiplegia in this study. Ultrasound imaging was used to measure amount of changes in thickness of the external oblique (EO), internal oblique (IO), transversus abdominis (TrA). A Paired t-test was used to compare relaxed muscle thickness to contracted muscle thickness of all 3 muscles between the affected and unaffected sides. Results : The outcome measures included side to side differences of absolute thickness, contraction ratio among the lateral abdominal muscles. There was no significantly difference in between the affected and unaffected side at rest. But, there was a significantly difference in absolute muscle thickness between the affected and unaffected side of only TrA muscle. Also contraction ratio was a significantly difference between the affected and unaffected TrA muscle. Conclusion : These findings support the asymmetrical activation of TrA muscle during abdominal muscle contraction in patients with post-stroke hemiplegia. Further studies are warranted for confirming this outcome.

유역특성 변화에 따른 도시유출모형의 매개변수 민감도분석(I) -민감도분석방법의 개발- (The Sensitivity Analysis of Parameters of Urban Runoff Models due to Variations of Basin Characteristics (I) - Development of Sensitivity Analysis Method -)

  • 서규우;조원철
    • 한국수자원학회논문집
    • /
    • 제31권3호
    • /
    • pp.243-252
    • /
    • 1998
  • 본 연구에서는 새로운 무차원값을 제시하여 도시유출모형의 매개변수결정을 위한 상대적인 민감도분석을 실시하여 매개변수별 민감도특성을 구명하였다. 민감도분석을 위한 무차원값으로 총유출량비,첨두유출량비, 유출민감도비, 민감도비율을 다음과 같이 개발하였다. $$ 유역면적의 크기와 강우분포형과 강우지속기간별로 각 적용단계별 총유출량비, 첨두유출량비, 유출민감도를 산정하기 위해 ILLUDAS모형과 SWMM모형의 매개변수를 선저하고 적정 적용범위를 결정하였다.

  • PDF

요추 자기공명영상에서 발생하는 Cross-talk Artifact 저감화 연구: 분할 TR 중심으로 (A Study on the Reduction of Cross-talk Artifact in Lumbar Magnetic Resonance Imaging : Focused on Concatenation Time Repetition)

  • 이재흔;이효영
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.715-723
    • /
    • 2020
  • 요추 자기공명 검사 시 병변 호발 부위인 Lumbar 4-5번, Sacrum 1번의 축상 영상 검사에서 인접한 두 그룹의 슬라이스 겹침으로 Cross-Talk 인공물이 발생한다. 이로 인해 병변 판독 시 문제점이 발생한다. 본 연구에서는 최적의 분할 TR의 적용을 통해서 Cross-Talk 인공물을 완벽히 제거하고자 한다. 관심 영역은 지방(ROI 1), 척추 기립근 바깥쪽(ROI 2), 척추 기립근 안쪽(ROI 3), 가시돌기(ROI 4)로 나눠 평균화하여 계측하였다. 신호 강도(SI)는 ROI 1의 경우 C4에서 163.43 ± 25.08, ROI 2, ROI 3은 C6에서 각각 67.89 ± 11.75, 69.99 ± 10.91, ROI 4는 C5에서 70.65 ± 27.21을 나타내었다(p<0.000). 신호 대 잡음 비(SNR)는 분할 TR 6에서 SNR 1, 2, 3, 4 값이 각각 135.45 ± 35.90, 56.92 ± 15.90, 58.77 ± 15.59, 54.91 ± 118.95로 나타났다(p<0.000). 대조도 대 잡음비(CNR)는 분할TR 6에서 CNR1, CNR2, CNR3, 값이 각각 78.52 ± 24.11, 76.67 ± 24.38, 80.54 ± 26.33로 나타났다(p<0.000). 시간 대비 최적의 분할 TR 값은 6이며, 이를 T1 축상면 영상에 적용한다면 인공물 저감화에 도움이 되리라고 판단된다.