• Title/Summary/Keyword: TPSM

Search Result 8, Processing Time 0.02 seconds

Analysis of the image composition speed of RT and TPSM algorithms (RT과 TPSM 알고리즘의 영상구성 속도 분석)

  • Jin-Seob Shin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.6
    • /
    • pp.139-143
    • /
    • 2023
  • In this paper, compared to the RT algorithm that constitutes CT images, the TPSM algorithm available in the conical CB-CT system was applied to enable 3D CT image configuration faster than the existing RT, and the image speeds of the two algorithms were compared and analyzed. To this end, the TPSM algorithm available in the conical CB-CT system was applied to enable real-time processing in 3D CT image composition. As a result of the experiment, it was found that the cross-sectional image constructed using TPSM decreases the quality of the image slightly by empty pixels as the distance from the center point increases, but in the case of TPSM rotation-based methods, the image composition speed is far superior to that of the RT algorithm.

Effects of Multi-stepwise TPSM on Improving the Behavior of H-beam bridge (H형강 교량의 성능개선을 위한 다단계 온도프리스트레싱 효과 분석)

  • Ahn, Jin Hee;Kim, Jun Hwan;Jung, Chi Young;Kim, Sang Hyo
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.5
    • /
    • pp.527-537
    • /
    • 2007
  • The main girders and cross-beams of an H-beam bridge consisted of factory-made H-beams, providing better conditions for quality control. Also, on-site fabrication works can be minimized and most of the stiffeners can be omitted, enabling simple and economic construction. In this study, the effect of the Multi-Stepwise TPSM (M-TPSM) on improving the maximum span length and section efficiency is analyzed. Compared to a 30-m-long, five-girder conventional plate girder bridge, structural analysis results showed that 50.7~55.1% of the girder height and 24.1~26.2% of the self-weight may be reduced by the application of M-TPSM to a five-girder H-beam bridge constructed with H-$900{\times}300$beams. In case of conventional H-beam bridges without M-TPSM, it was found that seven girders are required for a similar level of load-carrying capacity. Therefore, it is concluded that by the application of the M-TPSM, the H-beam bridge would become one of most cost-competitive options for short- and medium-span bridges.

Experimental Study on Application of Multi-Stepwise TPSM (다단계 온도프리스트레싱 공법의 현장적용을 위한 실험적 연구)

  • Ahn, Jin-Hee;Kim, Jun-Hwan;Kim, Sang-Hyo;Lee, Sang-Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.1
    • /
    • pp.91-100
    • /
    • 2008
  • Multi-stepwise Thermal Prestressing Method(TPSM) is a newly proposed prestressing method, which is combined the external prestressing method and the external bonding method. Multi-stepwise thermal prestressing force is induced by cooling process of cover-plate in the multi-stepwise temperature distribution after the cover-plate being bolted to the girder. In this study, the heating capacity test of the developed heating system for applying the multi-stepwise TPSM effectively and multi-stepwise TPSM inducing test of H-beam is performed. Also, a field test of the rhamen type temporary bridge is carried out to evaluate the effect and application of the multi-stepwise TPSM. Truck load was loaded and compared with the structure analysis results.

Experimental study on Static Behavior of H-beam prestressed with Multi-Stepwise TPSM (다단계 온도프리스트레싱 도입 강재보의 정적거동평가를 위한 실험적 연구)

  • An, Jin Hee;Jung, Chi Young;Kim, Jun Hwan;Kim, Sang Hyo
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.247-258
    • /
    • 2008
  • In this study, static loading tests were performed on H-beam specimens to assess the static behavior of H-beam prestressed with multi-stepwise thermal prestressing method (TPSM). The amount of induced thermal prestress and connection type were differentiated among the 400-mm-high and 6,000-mm-long H-beam specimens to evaluate their effect on the behavior of the beams. From the experimental results, it between the H-beam and the cover-plate increased in yielding load by 13~18%, whereas stiffness increased by 27~34%. In case of specimens with both bolting and welding connection, yie lding load increased by 18~29% and stiffness increased by 43~51%. Multi-stepwise initial stress distribution was also observed from the prestressed specimens, verifying the effectiveness of the multi-stepwise TPSM. By application of the multi-stepwise TPSM, a significant increase in yielding load and stiffness can be achieved, hence increasing sectional and prestressing efficiencies.

Load-Carrying Capacity Evaluation of the Composite Beam Strengthened by Multi-Stepwise Thermal Prestressing Method Using Cover-Plate (커버플레이트를 이용한 다단계 온도프리스트레싱으로 보강된 합성보의 하중-저항성능 분석)

  • Ahn, Jin-Hee;Jung, Chi-young;Choi, Kyu-Tae;Kim, Sang-Hyo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.4 s.56
    • /
    • pp.159-169
    • /
    • 2009
  • In this study, static loading tests and numerical analyses of the composite beam strengthened by multi-stepwise thermal prestressing method were carried out to evaluate the prestressing effect of the thermal prestressing prestress and the sectional effect of the installed cover-plate on the increase in the load-carrying capacity of composit beam. From this study, the strengthening method using multi-stepwise thermal prestressing method (TPSM) can be applied to reduce the deflection of the composite beam as well as to strengthening the composite beam by inducing the prestress in case of the occurrence in the large deflection by the insufficiency of the section properties of the composite beam. because of the expectation of the increase in the yield load and the sectional properties of the composite beam.

Load-carrying Capacity of Thermal Prestressed Steel Beam with Eccentric Bracket (편심 브라켓 설치 온도프리스트레싱 강재보의 하중저항 성능)

  • Kim, Sang-Hyo;Jung, Chi-Young;Choi, Kyu-Tae;Ahn, Jin-Hee
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.6
    • /
    • pp.563-572
    • /
    • 2010
  • This study evaluates the load-carrying capacity of a thermal prestressed steel beam with an eccentric bracket. The steel beam that is proposed in this study has an eccentrically installed cover plate through application of the eccentric bracket. The eccentric bracket helps the steel beam achieve greater sectional stiffness and more efficiently induces prestress. A material non-linear characteristic applied finite element analysis was also conducted to check the validity of the experiments. The results of this study showed that the structural stiffness, yield load, and ultimate strength of the TPSM-applied steel beam with the eccentric bracket increased due to the eccentricity of the cover plate.

The Algorithm Improved the Speed for the 3-Dimensional CT Video Composition (3D CT 동영상 구성을 위한 속도 개선 알고리즘)

  • Jeong, Chan-Woong;Park, Jin-Woo;Jun, Kyu-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.141-147
    • /
    • 2009
  • This paper presents a new fast algorithm, rotation-based method (RBM), for the reconstruction of 3 dimensional image for cone beam computerized tomography (CB CT) system. The system used cone beam has less exposure time of radioactivity than fan beam. The Three-Pass Shear Matrices (TPSM) is applied, that has less transcendental functions than the one-pass shear method to decrease a time of calculations in the computer. To evaluate the quality of the 3-D images and the time for the reconstruction of the 3-D images, another 3-D images were reconstructed by the radon transform under the same condition. For the quality of the 3-D images, the images by radon transform was shown little good quality than REM. But for the time for the reconstruction of the 3-D images REM algorithm was 35 times faster than radon transform. This algorithm offered $4{\sim}5$ frames a second. It meant that it will be possible to reconstruct the 3-D dynamic images in real time.

Comparative analysis of Glomerular Filtration Rate measurement and estimated glomerular filtration rate using 99mTc-DTPA in kidney transplant donors. (신장이식 공여자에서 99mTc-DTPA를 이용한 Glomerular Filtration Rate 측정과 추정사구체여과율의 비교분석)

  • Cheon, Jun Hong;Yoo, Nam Ho;Lee, Sun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.35-40
    • /
    • 2021
  • Purpose Glomerular filtration rate(GFR) is an important indicator for the diagnosis, treatment, and follow-up of kidney disease and is also used by healthy individuals for drug use and evaluating kidney function in donors. The gold standard method of the GFR test is to measure by continuously injecting the inulin which is extrinsic marker, but it takes a long time and the test method is complicated. so, the method of measuring the serum concentration of creatinine is used. Estimated glomerular filtration rate (eGFR) is used instead. However, creatinine is known to be affected by age, gender, muscle mass, etc. eGFR formulas that are currently used include the Cockroft-Gault formula, the modification of diet in renal disease (MDRD) formula, and the chronic kidney disease epidemilogy collaboration (CKD-EPI) formula for adults. For children, the Schwartz formula is used. Measurement of GFR using 51Cr-EDTA (diethylenetriamine tetraacetic acid), 99mTc-DTPA (diethylenetriamine pentaacetic acid) can replace inulin and is currently in use. Therefore, We compared the GFR measured using 99mTc-DTPA with the eGFR using CKD-EPI formula. Materials and Methods For 200 kidney transplant donors who visited Asan medical center.(96 males, 104 females, 47.3 years ± 12.7 years old) GFR was measured using plasma(Two-plasma-sample-method, TPSM) obtained by intravenous administration of 99mTc-DTPA(0.5mCi, 18.5 MBq). eGFR was derived using CKD-EPI formula based on serum creatinine concentration. Results GFR average measured using 99mTc-DTPA for 200 kidney transplant donors is 97.27±19.46(ml/min/1.73m2), and the eGFR average value using the CKD-EPI formula is 96.84±17.74(ml/min/1.73m2), The concentration of serum creatinine is 0.84±0.39(mg/dL). Regression formula of 99mTc-DTPA GFR for serum creatinine-based eGFR was Y = 0.5073X + 48.186, and the correlation coefficient was 0.698 (P<0.01). Difference (%) was 1.52±18.28. Conclusion The correlation coefficient between the 99mTc-DTPA and the eGFR derived on serum creatinine concentration was confirmed to be moderate. This is estimated that eGFR is affected by external factors such as age, gender, and muscle mass and use of formulas made for kidney disease patients. By using 99mTc-DTPA, we can provide reliable GFR results, which is used for diagnosis, treatment and observation of kidney disease, and kidney evaluation of kidney transplant patients.