• Title/Summary/Keyword: TOT

Search Result 139, Processing Time 0.025 seconds

Exact third-order static and free vibration analyses of functionally graded porous curved beam

  • Beg, Mirza S.;Khalid, Hasan M.;Yasin, Mohd Y.;Hadji, L.
    • Steel and Composite Structures
    • /
    • v.39 no.1
    • /
    • pp.1-20
    • /
    • 2021
  • An exact solution based on refined third-order theory (TOT) has been presented for functionally graded porous curved beams having deep curvature. The displacement field of the refined TOT is derived by imposing the shear free conditions at the outer and inner surfaces of curved beams. The properties of the two phase composite are tailored according the power law rule and the effective properties are computed using Mori-Tanaka homogenization scheme. The equations of motion as well as consistent boundary conditions are derived using the Hamilton's principle. The curved beam stiffness coefficients (A, B, D) are obtained numerically using six-point Gauss integration scheme without compromising the accuracy due to deepness (1 + z/R) terms. The porosity has been modeled assuming symmetric (even) as well as asymmetric (uneven) distributions across the cross section of curved beam. The programming has been performed in MATLAB and is validated with the results available in the literature as well as 2D finite element model developed in ABAQUS. The effect of inclusion of 1 + z/R terms is studied for deflection, stresses and natural frequencies for FG curved beams of different radii of curvature. Results presented in this work will be useful for comparison of future studies.

Recirculating Integrated System for the Treatment of Authentic Integrated-textile-dyeing Wastewater from Dyeing Industrial Complex (염색산업단지 종합폐수처리용 재순환 통합시스템)

  • Lee, Eun Ju;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.55 no.6
    • /
    • pp.837-845
    • /
    • 2017
  • A recirculating integrated system composed of a fluidized biofilter filled with waste-tire crumb media fixed with return sludge from wastewater treatment facility of D dyeing industrial center, and a UV/photocatalytic reactor packed with calcined $TiO_2$ coated-glass beads as photocatalyst-support, was constructed and was run to treat authentic textile-dyeing wastewater from D-dyeing industrial center, which was mixed with an alkaline polyester-weight-reducing wastewater and a wastewater from sizing process. As a result, its total removal efficiency(RE(tot)) of $COD_{cr}$ and colors were ca. 81% and 55%, respectively. The synergy effect of the recirculating integrated system to enhance total removal efficiency(RE(tot)) of $COD_{cr}$ and colors were evaluated at most ca. 7% and 3%, respectively. The fluidized biofilter and the UV/photocatalytic reactor were responsible for ca. 94% and 6% of the total $COD_{cr}$ removal efficiency, respectively, and were also responsible for ca. 86% and 14% of the total color-removal efficiency, respectively. Thus, the degree of the UV/photocatalytic reactor-unit process's contribution to RE(tot) of color, was about 2.4 times of that to RE(tot) of $COD_{cr}$. Therefore, the UV/photocatalytic reactor facilitated the more effective elimination of colors by breaking down the chemical bonds oriented from colors of dyes such as azo-bond, than $COD_{cr}$. In addition, the effect of the removal efficiency of each unit process(i.e., the fluidized biofilter or the UV/photocatalytic reactor) of the recirculating integrated system on RE(tot) of $COD_{cr}$ and colors, was analysed by establishing its model equation with an analytic correlation.

The Effect of Pressure Support on Respiratory Mechanics in CPAP and SIMV (CPAP 및 SIMV Mode하에서 Pressure Support 사용이 호흡역학에 미치는 효과)

  • Lim, Chae-Man;Jang, Jae-Won;Choi, Kang-Hyun;Lee, Sang-Do;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Park, Pyung-Whan;Choi, Jong-Moo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.3
    • /
    • pp.351-360
    • /
    • 1995
  • Background: Pressure support(PS) is becomimg a widely accepted method of mechanical ventilation either for total unloading or for partial unloading of respiratory muscle. The aim of the study was to find out if PS exert different effects on respiratory mechanics in synchronized intermittent mandatory ventilation(SIMV) and continuous positive airway pressure (CPAP) modes. Methods: 5, 10 and 15 cm $H_2O$ of PS were sequentially applied in 14 patients($69{\pm}12$ yrs, M:F=9:5) and respiratory rate (RR), tidal volume($V_T$), work of breathing(WOB), pressure time product(PTP), $P_{0.1}$, and $T_1/T_{TOT}$ were measured using the CP-100 pulmonary monitor(Bicore, USA) in SIMV and CPAP modes respectively. Results: 1) Common effects of PS on respiratory mechanics in both CPAP and SIMV modes As the level of PS was increased(0, 5, 10, 15 cm $H_2O$), $V_T$ was increased in CPAP mode($0.28{\pm}0.09$, $0.29{\pm}0.09$, $0.31{\pm}0.11$, $0.34{\pm}0.12\;L$, respectively, p=0.001), and also in SIMV mode($0.31{\pm}0.15$, $0.32{\pm}0.09$, $0.34{\pm}0.16$, $0.36{\pm}0.15\;L$, respectively, p=0.0215). WOB was decreased in CPAP mode($1.40{\pm}1.02$, $1.01{\pm}0.80$, $0.80{\pm}0.85$, $0.68{\pm}0.76$ joule/L, respectively, p=0.0001), and in SIMV mode($0.97{\pm}0.77$, $0.76{\pm}0.64$, $0.57{\pm}0.55$, $0.49{\pm}0.49$ joule/L, respectively, p=0.0001). PTP was also decreased in CPAP mode($300{\pm}216$, $217{\pm}165$, $179{\pm}187$, $122{\pm}114cm$ $H_2O{\cdot}sec/min$, respectively, p=0.0001), and in SIMV mode($218{\pm}181$, $178{\pm}157$, $130{\pm}147$, $108{\pm}129cm$ $H_2O{\cdot}sec/min$, respectively, p=0.0017). 2) Different effects of PS on respiratory mechanics in CP AP and SIMV modes By application of PS (0, 5, 10, 15 cm $H_2O$), RR was not changed in CPAP mode($27.9{\pm}6.7$, $30.0{\pm}6.6$, $26.1{\pm}9.1$, $27.5{\pm}5.7/min$, respectively, p=0.505), but it was decreased in SIMV mode ($27.4{\pm}5.1$, $27.8{\pm}6.5$, $27.6{\pm}6.2$, $25.1{\pm}5.4/min$, respectively, p=0.0001). $P_{0.1}$ was reduced in CPAP mode($6.2{\pm}3.5$, $4.8{\pm}2.8$, $4.8{\pm}3.8$, $3.9{\pm}2.5\;cm$ $H_2O$, respectively, p=0.0061), but not in SIMV mode($4.3{\pm}2.1$, $4.0{\pm}1.8$, $3.5{\pm}1.6$, $3.5{\pm}1.9\;cm$ $H_2O$, respectively, p=0.054). $T_1/T_{TOT}$ was decreased in CPAP mode($0.40{\pm}0.05$, $0.39{\pm}0.04$, $0.37{\pm}0.04$, $0.35{\pm}0.04$, respectively, p=0.0004), but not in SIMV mode($0.40{\pm}0.08$, $0.35{\pm}0.07$, $0.38{\pm}0.10$, $0.37{\pm}0.10$, respectively, p=0.287). 3) Comparison of respiratory mechanics between CPAP+PS and SIMV alone at same tidal volume. The tidal volume in CPAP+PS 10 cm $H_2O$ was comparable to that of SIMV alone. Under this condition, the RR($26.1{\pm}9.1$, $27.4{\pm}5.1/min$, respectively, p=0.516), WOB($0.80{\pm}0.85$, 0.97+0.77 joule/L, respectively, p=0.485), $P_{0.1}$($3.9{\pm}2.5$, $4.3{\pm}2.1\;cm$ $H_2O$, respectively, p=0.481) were not different between the two methods, but PTP($179{\pm}187$, $218{\pm}181 cmH_2O{\cdot}sec/min$, respectively, p=0.042) and $T_1/T_{TOT}$($0.37{\pm}0.04$, $0.40{\pm}0.08$, respectively, p=0.026) were significantly lower in CPAP+PS than in SIMV alone. Conclusion: PS up to 15 cm $H_2O$ increased tidal volume, decreased work of breathing and pressure time product in both SIMV and CPAP modes. PS decreased respiration rate in SIMV mode but not in CPAP mode, while it reduced central respiratory drive($P_{0.1}$) and shortened duty cycle ($T_1/T_{TOT}$) in CPAP mode but not in SIMV mode. By 10 em $H_2O$ of PS in CPAP mode, same tidal volume was obtained as in SIMV mode, and both methods were comparable in respect to RR, WOB, $P_{0.1}$, but CPAP+PS was superior in respect to the efficiency of the respiratory muscle work (PTP) and duty cycle($T_1/T_{TOT}$).

  • PDF

Comparison of Computation Complexity for Digital Pulse Compressor (디지털 펄스압축기의 연산 양 비교)

  • 신현익;김상규;조태훈;김환우
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.2196-2199
    • /
    • 2003
  • With the development of digital signal processor(DSP), digital pulse compressor (DPC) is commonly used in radar systems. A DPC is implemented by using finite impulse response(FIR) filter algorithm in time domain or fast Fourier transform(FFT) algorithm in frequency domain. This paper compares the computation complexity tot these two methods and calculates boundary Fm filter taps that determine which of the two methods is better based on computation amount. Also, it shows that the boundary FIR filter taps for DSP, ADSP21060, and those for computation complexity have similar characteristic.

  • PDF

Fault Tolerant Control Design Using IMM Filter with an Application to a Flight Control System (IMM 필터를 이용한 고장허용 제어기법 및 비행 제어시스템에의 응용)

  • 김주호;황태현;최재원
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.87-87
    • /
    • 2000
  • In this paper, an integrated design of fault detection, diagnosis and reconfigurable control tot multi-input and multi-output system is proposed. It is based on the interacting multiple model estimation algorithm, which is one of the most cost-effective adaptive estimation techniques for systems involving structural and/or parametric changes. This research focuses on the method to recover the performance of a system with failed actuators by switching plant models and controllers appropriately. The proposed scheme is applied to a fault tolerant control design for flight control system.

  • PDF

Runoff Characteristics of Nutrients from Agroforest Culture Field (산림농업지대에서 식물영양물질의 유출특성)

  • Kim, Eun-Hyeok;Cho, Jae-Young
    • Journal of Applied Biological Chemistry
    • /
    • v.57 no.4
    • /
    • pp.331-336
    • /
    • 2014
  • Sediment and nutrient loading caused by the forest to conversion of agricultural lands have led to the deterioration in near water ecosystem. This study was carried out to examine the effects of agroforest culture field and open field culture field on water quality and runoff loading of nutrient. The runoff loading of Tot-N and Tot-P in agroforest culture field were similar to open field culture field. The runoff loading of total suspended solids (TSS) in agroforest culture field and open field culture field were $2,721kg{\pm}196/10a$ and $420{\pm}29kg/10a$ in 2011 and $696kg{\pm}59/10a$ and $463{\pm}36kg/10a$ in 2012, respectively. Our investigation showed that the runoff loading of TSS from agroforest culture field decreased when soil cover and soil stabilization increased. Therefore, protect facility of soil erosion for early alteration of agricultural lands are needed to minimize the soil erosion from agroforest culture field.

An Experimental Study on the Thermal Characteristics of Ice Storage Tank - Focusing on the Adiabatic Effects of Ice Storage Tank - (직접접촉식 빙축열조의 전열특성에 관한 연구 - 빙축열조의 단열영향을 중심으로 -)

  • Lee, Chae-Moon;Park, Jung-Won;Cho, Nam-Chul;Park, Sang-Rok;Kim, Il-Gyoum;Kim, Dong-Chun;Kim, Young-Ki;Yim, Chang-Soon
    • Solar Energy
    • /
    • v.17 no.2
    • /
    • pp.75-89
    • /
    • 1997
  • In this paper, the operating thermal characterictics of liquid-ice was expeimentally investigated in an adiabatic and a non-adiabatic direct contact liquid-ice heat exchanger. Experiments were carried out varing inlet temperature, Ice Packing Factor, and the flow rate of heat transfer fluid. The higher inlet temperature and the more much inlet flow rate, thermal stratification in liquid-ice heat exchanger was established faster. In the case of adiabatic ice storage tank, temperature distribution was a little higher at all conditions than that of non-adiabatic one. The ratio of latent energy to total discharge energy($E_{\lambda}/E_[tot}$) was about 80%, and the discharge of latent heat energy was appeared rapidly as inlet temperature and flow rate were higher.

  • PDF

Deposition Characteristic of InNx Films by Reactive DC Magnetron Sputtering (반응성 직류 스퍼터법에 의한 질화 인듐 박막의 제막 특성)

  • 송풍근;류봉기;김광호
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.8
    • /
    • pp.739-745
    • /
    • 2003
  • In $N_{x}$ films were deposited on soda-lime glass without substrate heating by reactive dc magnetron sputtering using indium (In) metal target. Depositions were carried out under various total gas pressures ( $P_{tot}$) of mixture gases (Ar+$N_2$ or He+$N_2$). He gas was introduced to $N_2$ gas in order to enhance the reactivity of nitrogen on film surface by the "penning ionization". Plasma impedance decreased greatly when 20% or more introduced the $N_2$ gas. This is due to the In $N_{x}$ layers formed on target surface because a secondary electron emission rate of InN is small compared with In metal. XRD patterns of the films revealed that <001> preferred oriented polycrystalline In $N_{x}$ films, where the crystallinity of the films was improved with decrease of $P_{tot}$ and with increase of $N_2$ flow ratio. The improvement of the crystallinity and stoichimetry of the In $N_{x}$ films were considered to be caused by an increase in the activated nitrogen radicals and also by an increase in the kinetic energy of sputtered In atoms arriving at growing film surface, which should enhance the chemical reaction and surface migration on the growing film surface, respectively. Furthermore, the films deposited using mixture gases of He+$N_2$ showed higher crystallinity compared with the film deposited by the mixture gases of Ar+$N_2$.$.EX>.

Analysis of Spatial-temporal Variability and Trends of Extreme Precipitation Indices over Chungcheong Province, South Korea (충청지역 극한강우지수의 시공간적 경향과 변동성 분석)

  • Bashir, Adelodun;Golden, Odey;Seulgi, Lee;Kyung Sook, Choi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.6
    • /
    • pp.101-112
    • /
    • 2022
  • Extreme precipitation events have recently become a leading cause of disasters. Thus, investigating the variability and trends of extreme precipitation is crucial to mitigate the increasing impact of such events. Spatial distribution and temporal trends in annual precipitation and four extreme precipitation indices of duration (CWD), frequency (R10 mm), intensity (Rx1day), and percentile-based threshold (R95pTOT) were analyzed using the daily precipitation data of 10 observation stations in Chungcheong province during 1974-2020. The precipitation at all observation stations, except the Boryeong station, showed nonsignificant increasing trends at 95% confidence level (CL) and increasing magnitudes from the west to east regions. The high variability in mean annual precipitation was more pronounced around the northeast and northwest regions. Similarly, there were moderate to high patterns in extreme precipitation indices around the northeast region. However, the precipitation indices of duration and frequency consistently increased from the west to east regions, while those of intensity and percentile-based threshold increased from the south to east regions. Nonsignificant increasing trends dominated in CWD, R10 mm, and Rx1day at all stations, except for R10 mm at Boeun station and Rx1day at Cheongju and Jecheon stations, which showed a significantly increasing trend. The spatial distribution of trend magnitude shows that R10 mm increased from the west to east regions. Furthermore, variations in precipitation were very strongly correlated (99% CL) with R10 mm, Rx1day, and R95pTOT at all stations, except with wR10 mm at Cheongju station, which was strongly correlated with a 95% CL.

Projections on climate internal variability and climatological mean using hourly time series (시단위 시계열을 이용한 기후 내적 변동성 및 기후학적 평균에 대한 예측)

  • Kim, Jongho;Doi, Manh Van
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.198-198
    • /
    • 2020
  • 기후 내적 변동성(Climate Internal Variability, CIV)은 기후를 이해하는 데 중요한 역할을 하며 기후예측에 있어 주요 불확실성 원인들 중 하나이다. 본 연구는 다양한 이산화탄소 배출 시나리오에 대해 CIV와 기후학적 평균(Climatological Mean, CM)을 추정하는 것을 목표로 한다. 확률론적 날씨생성기(Stochastic Weather Generator)를 이용하여 국내 40개 기상 관측소에 대해, 30년에 해당하는 시단위 시계열 100개 앙상블을 생성하였다. CIV는 Detrend 방법과 Differenced 방법을 이용하여 추정되었으며, noise 계산값과 비교하였다. 그 결과, CIV 값과 noise 값들 사이의 correlation이 매우 높았으며, 제시된 방법론이 신뢰할 수 있음을 검증하였다. 국내 40개 지역에 적용하여 계산된 CIV와 CM의 주요 결과는 다음과 같다. (1) 국내의 대부분의 지역에 있어 평균적으로 CM과 CIV는 미래에 증가할 것이며, 그 증가 정도는 RCP 8.5의 경우와 먼 미래END(2071-2100년) 기간에서 더 커질 것이다; (2) CM과 CIV의 미래 변화의 특성은 강수의 특성 지수에 따라 다르다. 강수량의 양을 나타내는 3개의 지수(총 강수량, totPr, 일 최대 강수량, maxDa 및 시간당 최대 강수량, maxHr)와 강수량의 발생일수를 나타내는 지수(무강우 일수, nonPr)의 특성은 크게 다르다. (3) CIV와 CM의 변화 요인들 사이의 관계를 조사하면 maxDa와 maxHr에 대해서는 그들 사이에 높은 상관관계가 있지만 다른 지수에는 그렇지 않다. (4) 국내에서 CIV 값이 공간적으로 변동성이 큰 경우는 계절적으로 여름이며, 이는 totPr 및 maxDa에서만 유효하다. 시단위 시계열 앙상블을 생성하여 추정된 기후내적변동성 정보는 기후 변화의 영향을 평가하고 적절한 적응 및 대응 전략을 개발하는 데 도움이 될 것이다.

  • PDF