• Title/Summary/Keyword: TOF

Search Result 1,075, Processing Time 0.029 seconds

Tetralogy of Fallot associated with Absent Right Pulmonary Artery and Rudimentary Pulmonary Valve A Case Report (우폐동맥 결손과 폐동맥판막 발육부전을 동반한 활로씨 4 징증 1례 치험)

  • No, Jun-Ryang;Kim, Eung-Jung
    • Journal of Chest Surgery
    • /
    • v.18 no.3
    • /
    • pp.428-435
    • /
    • 1985
  • Tetralogy of Fallot associated with a single pulmonary artery is a rare cardiac anomaly. In previously reported cases, left pulmonary arteries were absent except 2 cases. Congenital absence of the pulmonary valve is a rare anomaly too. In the majority of cases, this lesion is associated with TOF. TOF associated with a single pulmonary artery and absent pulmonary valve is a very rare anomaly and only less than 20 cases were reported in the literatures. We have operated on one patient with TOF associated with absent right pulmonary artery and rudimentary pulmonary valve, a variant of absent pulmonary valve, and report this case with review of the literatures.

  • PDF

Development of a TOF LADAR Sensor for Unmanned Vehicle Systems (무인수송체 시스템용 TOF 방식 이차원 라이다 센서 개발)

  • Kim, MinGyu;Park, YongWoon;Won, Mooncheol
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.415-423
    • /
    • 2016
  • A TOF type LADAR is utilized for unmanned systems(UGV, UAV, USV, etc.), precision digital elevation maps, and electronic fences. Electronical and optical signal processing techniques are melted in LADAR sensor systems. In this study important factors are examined for high reliability sensor development. By considering those factors, hardwares and softwares of a test LADAR is developed and tested, We report the practical design tips, test results, and future works for better LADAR system development.

Optimization in Detecting Multiply-charged Protein Ions using MALDI TOF-MS

  • Lee, Jihyeon;Hong, Jangmi;Kim, Taehee;Kim, Jeongkwon
    • Mass Spectrometry Letters
    • /
    • v.4 no.1
    • /
    • pp.21-23
    • /
    • 2013
  • The effects of trifluoroacetic acid (TFA) were evaluated on the generation of multiply charged ions of cytochrome c in a 2-nitrophloroglucinol (2-NPG) matrix in high-vacuum, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). The presence of 1% TFA in the 2-NPG matrix solution was more effective in generating multiply charged protein ions than matrix solutions containing 0.1% or 0% TFA. Regarding the matrix itself, with 1% TFA, 2-NPG was significantly more effective in generating multiply charged ions than 2,5-dihydroxybenzoic acid (2,5-DHB). The maximum charge state of cytochrome c was +8 when using a 2-NPG matrix containing 1% TFA.

Postharvest Biological Control of Colletotrichum acutatum on Apple by Bacillus subtilis HM1 and the Structural Identification of Antagonists

  • Kim, Hae-Min;Lee, Kui-Jae;Chae, Jong-Chan
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.11
    • /
    • pp.1954-1959
    • /
    • 2015
  • Bacillus subtilis HM1 was isolated from the rhizosphere region of halophytes for its antifungal activity against Colletotrichum acutatum, the causative agent of anthracnose. Treatment of postharvest apples with the cell culture or with a cell-free culture supernatant reduced disease severity 80.7% and 69.4%, respectively. Both treatments also exhibited antifungal activity against various phytopathogenic fungi in vitro. The antifungal substances were purified and analyzed by acid precipitation, gel filtration, high-performance liquid chromatography, and matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). Three compounds were identified as fengycin, iturin, and surfactin. The MALDI-TOF/TOF mass spectrum revealed the presence of cyclized fengycin homologs A and B, which were distinguishable on the basis of the presence of either alanine or valine, respectively, at position 6 of the peptide sequence. In addition, the cyclized structure of fengycin was shown to play a critical role in antifungal activity.

Analysis of Branched PEG-Conjugated Interferon Alpha by Capillary Electrophoresis and MALDI- TOF Mass Spectrometry

  • Na, Dong-Hee;Park, Eun-Ji;Lee, Snag-Deuk;Jo, Young-Woo;Lee, Sung-Hee;Kim, Won-Bae;Lee, Kang-Choon
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.406.3-407
    • /
    • 2002
  • Analysis of interferon alpha (IFN) modified with high molecular weight branched PEG was performed by capillary electrophoresis (CE) and MALDI-TOF mass spectrometry (MALDI-TOF MS). IFN was modified by the reaction of amine residues with an active ester of monomethoxy polyethylene glycol at various molar ratios. As a CE method. capilary electrophoresis sodium dodecyl sulfate nongel sieving (CE-SDS NGS) was performed using an uncoated capilary filled with a hydrophilic replaceable polymer network matrix. (omitted)

  • PDF

Precise Measurement of Beam Energy and Range with TOF and Counter Telescope System

  • Nanbu, Shuya;Kanai, Tatsuaki;Kohno, Toshiyuki;Ohno, Yumiko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.225-227
    • /
    • 2002
  • In order to improve the accuracy of charged-particle radiation therapy, the beam energy was measured precisely using a TOF-system, and the range using a counter telescope system. A Si detector and a Ge detector were used to estimate the range straggling as a $\Delta$E and an E detector, respectively, because they have good energy resolution and the output pulse heights don't depend on the atomic number of detected particles. The results were compared with the theoretical values by a calculation code.

  • PDF

Preliminary study of time-of-flight measurement for 3D position sensing system based on acoustic signals

  • Kim, Heung-Gi;Park, Youngjin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.79.4-79
    • /
    • 2002
  • Our goal is the development of a system that estimates the location of interested point in a room with accuracy and low cost. Non-contacting position estimating method is widely used in various areas. Among these methods, acoustic signal-based method is the cheapest and provides reasonably accurate estimation as a result of many research efforts. Most of the acoustic-signal-based three-dimensional location estimators such as 3D sonic digitizer are using the ultrasound, and are organized with two procedures; time-of-flight (TOF) estimation and localization estimation. Since the errors in estimating the TOF could be accumulated with that of localization estimate, accuracy of TOF estimate is as...

  • PDF

Diagnosis of Subclavian Steal: Contrast Enhanced 3D MR Angiography vs 2D TOF

  • 이호규;김건언;최중곤;서대철
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.136-136
    • /
    • 2001
  • Purpose: Subclavian steal refers to the retrograde flow of blood in a vertebral artery that supplies t ipsilateral shoulder and arm caused by proximal subclavian artery stenosis or occlusion. T purpose of this exhibit is to demonstrate MR findings of subclavian steal on contrast-enhanc 3D (CE 3DMRA) and 2D TOF MR angiography. Method: Four patients(men 3 and women 1, age: 28-78years) with subclavian steal obtained both CE 3DMRA and digital subtraction angiography(DSA) including subclavian arterie Sequential imaging was undertaken during first pass after double dose of Gd-DTPA (0 mM/kg) Injected by a power injector. Coronal source images were obtained with coronal D-fast low angle shot sequence(TR/TE/flip angle=3.8/l.3/35, acquisition time= 10sec/one measurement). Precontrast imaging was subtracted from enhanced images and maximu intensity projection was done. 2D time-of-flight MR angiography(2D TOF) of the carot bifurcation was added in all cases with post-saturation. All studies were review retrospectively.

  • PDF

Metabolomics Approach for Classification of Medicinal Plants

  • Lee, Dong-Ho
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.5-5
    • /
    • 2010
  • Selection of specific medicinal sources as well as bioactive compounds is important for the preparation of medicine and related products with good quality. It is necessary to pay close attention for choosing correct medicinal sources, particularly in case of medicinal plants, because of their diversity, which can affect the quality and efficacy of medicine. Discrimination of plants based on morphological or genetic characteristics has been used as a conventional classification method of pharmaceutical sources so far; however, more need demands more general methods for accurate quality assessment of medicinal plants. In this study, ultra performance liquid chromatography/quadrupole time-of-flight mass spectrometry (UPLC/Q-TOF MS) technique applied to this metabolic profiling is a powerful tool due to its higher sensitivity, resolution, and speed compared to conventional HPLC technique. The metabolite profiling of several medicinal plants including Panax ginseng was carried out using UPLC/Q-TOF MS and total metabolites were then subsequently applied to various statistical tools to compare the patterns. The developed metabolomics tool with UPLC/Q-TOF MS successfully identified and classified the samples tested according to their origins.

  • PDF

Comparative evaluation of intracranial aneurysms between 3D-TOF MRA with 3.0T MR and CTA with 16-slices MDCT

  • 정태섭;이재훈;정우석;조은석
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.23-23
    • /
    • 2003
  • To evaluate clinical visualization of intracranial aneurysms between 3D-TOF MRA with 3.0T MR and CTA with 16-slices MDCT. In a prospective series, 12 patients with 16 aneurysms were studies with 3D-TOF MRA and CTA. MRA were performed on a GE Signa 3.0 T system (Signa VH/i, GE) with 25/3/20 (TR/TE/FA). CTA were peformed on a 16 slice MDCT (Sensation 16, Somatom, Siemens) with IV shooting of 80 ml iodinated contrast mediumat antecubital vein at a rate of 3.5 ml/sec. Four among 12 patients underwent DSA for surgery. Size, shape, neck and parent vessel of aneurysms were evaluated for comparison of visualization and detectability of aneurysms.

  • PDF