• 제목/요약/키워드: TNO

검색결과 48건 처리시간 0.027초

Explosive loading of multi storey RC buildings: Dynamic response and progressive collapse

  • Weerheijm, J.;Mediavilla, J.;van Doormaal, J.C.A.M.
    • Structural Engineering and Mechanics
    • /
    • 제32권2호
    • /
    • pp.193-212
    • /
    • 2009
  • The resilience of a city confronted with a terrorist bomb attack is the background of the paper. The resilience strongly depends on vital infrastructure and the physical protection of people. The protection buildings provide in case of an external explosion is one of the important elements in safety assessment. Besides the aspect of protection, buildings facilitate and enable many functions, e.g., offices, data storage, -handling and -transfer, energy supply, banks, shopping malls etc. When a building is damaged, the loss of functions is directly related to the location, amount of damage and the damage level. At TNO Defence, Security and Safety methods are developed to quantify the resilience of city infrastructure systems (Weerheijm et al. 2007b). In this framework, the dynamic response, damage levels and residual bearing capacity of multi-storey RC buildings is studied. The current paper addresses the aspects of dynamic response and progressive collapse, as well as the proposed method to relate the structural damage to a volume-damage parameter, which can be linked to the loss of functionality. After a general introduction to the research programme and progressive collapse, the study of the dynamic response and damage due to blast loading for a single RC element is described. Shock tube experiments on plates are used as a reference to study the possibilities of engineering methods and an explicit finite element code to quantify the response and residual bearing capacity. Next the dynamic response and progressive collapse of a multi storey RC building is studied numerically, using a number of models. Conclusions are drawn on the ability to predict initial blast damage and progressive collapse. Finally the link between the structural damage of a building and its loss of functionality is described, which is essential input for the envisaged method to quantify the resilience of city infrastructure.

Nano-scale PMOSFET에서 Plasma Nitrided Oixde에 대한 소자 특성의 의존성 (Dependency of the Device Characteristics on Plasma Nitrided Oxide for Nano-scale PMOSFET)

  • 한인식;지희환;구태규;유욱상;최원호;박성형;이희승;강영석;김대병;이희덕
    • 한국전기전자재료학회논문지
    • /
    • 제20권7호
    • /
    • pp.569-574
    • /
    • 2007
  • In this paper, the reliability (NBTI degradation: ${\Delta}V_{th}$) and device characteristic of nano-scale PMOSFET with plasma nitrided oxide (PNO) is characterized in depth by comparing those with thermally nitrided oxide (TNO). PNO case shows the reduction of gate leakage current and interface state density compared to TNO with no change of the $I_{D.sat}\;vs.\;I_{OFF}$ characteristics. Gate oxide capacitance (Cox) of PNO is larger than TNO and it increases as the N concentration increases in PNO. PNO also shows the improvement of NBTI characteristics because the nitrogen peak layer is located near the $Poly/SiO_2$ interface. However, if the nitrogen concentration in PNO oxide increases, threshold voltage degradation $({\Delta}V_{th})$ becomes more degraded by NBT stress due to the enhanced generation of the fixed oxide charges.

Wind loads on T-shaped and inclined free-standing walls

  • Geurts, Chris;van Bentum, Carine
    • Wind and Structures
    • /
    • 제13권1호
    • /
    • pp.83-94
    • /
    • 2010
  • Wind tunnel measurements on T-shaped free-standing walls and inclined free-standing walls have been carried out. Mean net pressure coefficients have been derived and compared with previous research. It was observed that the high loads at the free ends are differently distributed than those derived from the pressure coefficients for free-standing walls in EN 1991-1-4. In addition net pressure coefficients based on extreme value analysis have been obtained. The lack of correlation of the wind induced pressures at windward and leeward side result in lower values for the net pressure coefficients when based on extreme value analysis. The results of this wind tunnel study have been included in Dutch guidelines for noise barriers.

지하매설 도시가스배관의 누출시나리오에 따른 사고피해영향분석 (Consequence Analysis for Release Scenario of Buried High Pressure Natural Gas Pipeline)

  • 김진형;고병석;양재모;고상욱;고재욱
    • 한국가스학회지
    • /
    • 제18권3호
    • /
    • pp.67-74
    • /
    • 2014
  • 인구가 밀집되어 있는 도심지역에 매설된 천연가스 공급배관은 외부 또는 내부 결함으로 인한 가스의 누출, 확산, 화재, 폭발로 발생되는 재산과 인명피해의 큰 잠재위험을 지니고 있다. 사고를 미연에 방지하기 위해 정량적 평가에 기초한 위험관리를 실시하고 있으며, 매설배관의 정량적 위험성을 평가하기 위해서는 우선적으로 사고피해영향 분석을 통한 화학물질의 누출량 계산, 확산 분석, 화재 및 폭발로 인한 복사열과 압력파 계산이 필요하다. 본 논문에서는 CCPS, TNO에서 제안하는 model 들을 통하여 실제 San Bruno 매설배관 폭발 사고 시나리오를 기반으로 천연가스의 누출량, Fireball의 복사열 계산을 수행하고 결과 값을 실제 피해결과와 비교분석 하였다.

국내 소음기준을 이용한 성가심(annoyance) 변환에 관한 연구 (A Study on the Conversion of Annoyance using the Noise Standard in Korea)

  • 김득성;장서일;이기정;이연수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.754-758
    • /
    • 2006
  • The purpose of this study is to propose calculation and application method of a common factor from different noise source unit such as $L_{eq}$ and WECPNL, A calculation was conducted by method that propose TNO-PG. Also, An applied example is a noise environmental standard of Korea and Japan. After %HA of two country are calculated, noise standards of two countries were compared by using %HA. The result by a equation of %HA is to convert a noise level($L_{dn}$) into a %HA. To calculate a %HA, First $L_{eq}$ is converted into $L_{dn}$. Then, $L_{dn}$, has inputted into and %HA has deduced from a %HA equation of TNO-PG. If the same area is applied the same %HA value according to area categories, it can be applied the same %HA to different noise sources. As a results. a noise levels have computed different values because responses of human change in accordance with a noise sources. This results can be applied to the noise environmental assessment for a domestic railway and aircraft noise.

  • PDF

Creep behaviour of flexible adhesives

  • van Straalen, Ijsbrand J.;Botter, Erik;van den Berg, Arnold;van Beers, Peter
    • 접착 및 계면
    • /
    • 제5권2호
    • /
    • pp.5-14
    • /
    • 2004
  • Since flexible adhesives are used more and more in structural applications, designers should have a better understanding of its behaviour under various conditions as ultimate load, fatigue load, long-term load and environmental conditions. This paper focuses on long-term load conditions and its effect on flexible adhesives. The creep properties of both PU (PolyUrethane) and SMP (Silyl Modified Polymers) adhesives used for identical applications are considered. To investigate the creep behaviour tests under various conditions were done. The results of those tests are presented and compared. To evaluate these results an empirical method is proposed and discussed. An example illustrates the potential of this method. It is also shown that with use of a probabilistic calibration technique this method results into a simple rule, which can be used to calculate the creep for practical applications. For the studied adhesives, the creep performance of the SMP adhesive is shown to be of the same level or slightly better than of the two PU adhesives. In addition to this empirical method, the principles of a more complex theoretical based method are introduced. The potential of this method is illustrated and future research activities are drawn.

  • PDF

HTML5 웹 기반 가연성 물질 누출 피해영향평가 시스템 개발 (A Development of Consequence Analysis System for Combustible Materials Release Events Based on HTML5 Web)

  • 이우귀연;지현민;오정석;조완수
    • 한국가스학회지
    • /
    • 제23권6호
    • /
    • pp.39-60
    • /
    • 2019
  • 한국가스안전공사는 진단 기반기술 국산화와 진단 역량 강화를 위해 자체적인 피해영향평가 시스템을 구축하고 있다. 유사 프로그램인 DNV PHAST나 TNO EFFECTS와 달리, API-581 기준을 근간한 ETA 분석을 통해 최종 피해영역 산출 기법을 구현하였으며, HTML5 기반 차세대 웹 기술을 기반으로 편리한 사용자 인터페이스를 구축하였다. 또한, 혼합물질 분석이 가능하도록 3차 상태방정식(Peng-Robinson, SRK, RK)과 퓨게시티를 활용한 상평형 모듈이 구현되었고, 공기보다 무거운 가스에 대한 확산 분석을 위해 SLAB Dispersion 알고리즘을 적용하였다. CCPS와 TNO Yellow Book에서 소개된 피해영향평가 알고리즘을 채용하여 누출분석 모듈, Fireball, Pool Fire, Jet Fire, Flash Fire, Vapor Cloud Explosion 영향 평가 모듈을 개발하였다. 그 외 EIGA 기준, PAC 기준 농도, Bevi Reference Book 등에서 제시된 기준 값들을 활용하여 안전거리 산출 조건을 마련하였다. 현재 전체 계산 모듈의 알고리즘 구현은 완료되었으며, 기본적인 사용자인터페이스 구축까지 완료되었다. 향후, 사용자 인터페이스 보완과 더불어, 모듈 각각에 대한 개별적인 검증과 동일한 사고 시나리오에 대한 유사 프로그램 구동 결과를 비교하여 전체 시스템의 정확도를 보완할 예정이다.

제 4류 위험물 취급소 및 LPG 충전소의 화재$\cdot$폭발 피해 영향분석 (Consequence Analysis of the Fire & Explosion on the Flammable Liquid Handling Facility and LPG Station)

  • 이수경;이창욱
    • 한국가스학회지
    • /
    • 제3권2호
    • /
    • pp.77-84
    • /
    • 1999
  • 본 연구에서는 경기도 부천시 OOO소재의 위험물 판매 취급소인 XX상사를 표준모델로 선정하여 여기서 취급하는 제 4류 위험물에 대한 위험성 평가를 실시하고 아울러 바로 길건너 맞은편의 약 20m 거리에 위치한 LPG 충전소에 대한 위험성 평가도 아울러 실시하였다. 본 연구에서의 위험성평가를 위해서는 PHAST와 Super-Chem 소프트웨어를 이용하였으며 이러한 Simulation 결과를 이용하여 분석한 결과 물질 중 아세톤의 경우 TNO 모델에 의한 복사열 평가에 의해 설비에 손상을 줄 수 있는 $37.5kw/m^2$에 해당하는 거리는 PHAST 모델의 경우 68.51m에 이르렀으며, Super-Chem 모델의 경우는 40.9,3m에 이르렀다. LPG 충전소에 대한 Simulation 결과 Fireball 지름은 125.2m에 이르며 Fireball의 높이는 206.2m에 이른다. 또한, 그 지속시간은 11.28초로 계산되었다.

  • PDF

융합대비에 따른 주시시차와 조절의 변화 (Change of Fixation Disparity and Accommodation when the Fusion Contrast Varied)

  • 서재명
    • 한국안광학회지
    • /
    • 제14권4호
    • /
    • pp.77-81
    • /
    • 2009
  • 목적: 융합대비의 변화에 따른 주시시차를 추적하며 동시에 버전스 체계와 밀접한 조절의 관계를 확인해 보고자 한다. 방법: 양안 교정시력이 1.0이상이며 입체시 지각이 확인된 16명을 대상으로 하였다. 굴절 및 양안시 검사는 Zeiss Polatest Classic을 사용하였으며 입체시차는 TNO를 사용하여 측정하였다. 난점 입체시표와 배열시표는 프로 그램화 된 컴퓨터를 사용하여 대비의 변화와 시간을 정확히 제어하였다. 결과: 주시시차는 융합대비의 감소에 따라 안구는 외전성 경향을 보였다(p=0.0004). 외사위안에서 비교차성 비대응 결상시 융합대비가 감소할수록 외전현상이 더욱 두드러졌다. 융합대비의 변화는 조절에 영향을 주지 않았지만(p=0.803) 배열시표에는 영향을 주는 것으로 밝혀졌다(p=0.0000). 결론: 융합대비가 저하될수록 안구는 외전성 경향을 보이나 조절의 변화는 없다.

  • PDF