• Title/Summary/Keyword: TN-S

Search Result 504, Processing Time 0.038 seconds

The Application Method of a Protection Conductor for the Prevention of Electric Shock in England (감전사고 예방을 위한 영국의 보호도체 적용 방법)

  • Jung, Jin-Soo;Jung, Jong-Wook;Han, Woon-Ki;Lee, Jun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2216-2217
    • /
    • 2008
  • This paper write about earth system for the prevention electric shock and a protection of equipment in england. The IEC60364 and BSI(British Standards Institution) define earthing method(IT, TT, TN-C, TN-S, TN-C-S)-BSI is british standards and in case of england almost use the TN system. TN system can classify TN-S & TN-C-S(PME). The findings on survey in england are used the TN-S system and TN-C-S system about 70% and residue 30% are used TT system and IT system from the exiting state of things.

  • PDF

The Comparison and Analysis about Earth System based on IEC60364 (IEC 60364 기반 접지계통 비교 분석)

  • Jung, Jin-Soo;Han, Woon-Ki;Kim, Oh-Hwan;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.56-62
    • /
    • 2010
  • This paper describes the analysis of loop impedance characteristics by impedance alteration of protective conductors and operating characteristics of electric leakage circuit breaker by each earth systems(TT system, TN-S system and TN-C system) in IEC 60364. As a result, loop Impedance was affected by resistance & inductance. The current& voltage characteristics about earth system were identified that the TN-S system was high fault current & low touch voltage. TN-C system was almost same the TN-S system but TT system was low fault current & high touch voltage.

Hazards and Solutions of Loss of the PEN Conductor in TN-C-S System (TN-C-S계통에서 PEN도체의 단선고장의 위험성 및 보호대책)

  • Lee, Bok-Hee;Lee, Kyu-Sun;Ahn, Chang-Hwan;Kim, Han-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.113-120
    • /
    • 2007
  • This paper presents the electric shock hazards and solutions of loss of the combined protective and neutral (PEN) conductor in TN-C-S system. In order to mitigate the touch voltage on exposed-conductive-parts in a break in the PEN conductor, the touch voltages on exposed-conductive-parts in a break in the PEN conductor were experimentally investigated as a function of the ground resistances of the source grounding electrode and customer's additional grounding electrode. As a result, the equipotential bonding is one of important requirements for installations supplied by TN-C-S system. A solution of mitigating the touch voltages on exposed-conductor-parts caused by a loss of the PEN conductor would be the installation of the additional grounding electrode at the customer's service entrance. The ground resistance of additional grounding electrode necessary to limit the touch voltage to a safety voltage of less than 50[V] depends on the load and circuit parameters. In addition, the undervoltage sensing devices oner affordable solutions to detect a loss of the PEN conductor in TN-C-S system.

Genetic Analysis of Caulobuter crescentus by Using Transposon Tn5 and Reverse Field Electrophoresis (Transposon Tn5 및 Reverse Field Electrophoresis를 이용한 Caulobuter crescentus의 유전자 분석 연구)

  • 구본성;버트일리
    • Microbiology and Biotechnology Letters
    • /
    • v.17 no.3
    • /
    • pp.183-187
    • /
    • 1989
  • The bacteriophage Mu and transposon Tn5 containing plasmid pJB4JI-transferred transposon Tn5 to Caulobuter crescentus. When several thousand of transposon Tn5 insertion mutants were examined, we found auxotrophic and motility mutants at frequencies of 2% and 3%, respectively. Transposition of transposon Tn5 was analyzed by the reverse field electrophoresis and Southern hybridization. The results indicated that transposon Tn5 was randomly inserted to Caulobuter crescentus chromosome but the plasmid vector, pJB4JI, was not maintained.

  • PDF

The Effect of Reject Water on the Water Quality of Effluent from S Sewage Treatment Plant (S 하수처리장 반류수가 방류수 수질에 미치는 영향)

  • Kim, Mi-Ran;Kim, Kyoung-Hee;Park, Hae-Sik;Kang, Dong-Hyo;Lee, Jea-Keun
    • Journal of Environmental Science International
    • /
    • v.19 no.3
    • /
    • pp.323-329
    • /
    • 2010
  • To acquire preliminary data for the control of total nitrogen (TN) in S sewage treatment plant, which processes merging food waste and sewage, the effect of reject water on the total nitrogen in the effluent was examined in this study. Water quality data for the plant during the winter period were applied to calculate the mass balance. It was calculated that at least more than 231 kg/d TN should be removed to control the TN concentration in the effluent. Assuming 18 ppm as the goal TN concentration in the effluent, about 941 kg/d TN should be removed from this plant. Approximately 10% more TN should be removed than at present to achieve this result. It was observed that dewatering the filtrate had a considerably greater effect on the total nitrogen in the effluent than the reject waters. The dewatered filtrate contained 1,399kg/d TN. The contribution of the dewatered filtrate to the TN concentration in the effluent was 0.183, which was 7 to 23 times greater than the other reject waters. In addition, the amount of total nitrogen from the reject water, with the exception of the dewatering filtrate, was lower than the amount of TN that should be removed from S sewage treatment plant. Therefore, it was concluded that one of the most effective methods for controlling the TN concentration in effluent was the removal of the TN contained in the dewatering filtrate.

Increased Expression of aac(3)II by Tn3 in Gentamicin - Resistant Bacteria Isolated from Hospital Sewage (병원하수로부터 분리한 Gentamicin 저항성 세균에서 Tn3에 의한 aac(3)II의 발현 증가)

  • 한효심;이문숙;정재성
    • Korean Journal of Microbiology
    • /
    • v.40 no.1
    • /
    • pp.60-64
    • /
    • 2004
  • We tested gentamicin - resistant bacteria isolated from hospital sewage to confirm the presence of aac(3)II encoding aminoglycoside- (3)-N- acetyltransferase by dot-blot hybridization. A probe from the internal fragment of aac(3)II was hybridized to DNA from 41 % (39/95) of gentamicin resistant isolates. PCR was performed with primers from aac(3)II and Tn3. Of 39 strains, 13 strains had Tn3-aac(3)II structure. Minimal inhibitory concentration (MIC) test demonstrated that 18 strains containing Tn3-aac(3)II showed higher resistance to gentamicin than those of other strains. Thirteen strains were identified as 5 Escherichia coli, 3 Acinetobacter johnsonii, 2 Enterobacter agglomerans, 2 Micrococcus luteus, and 1 Pseudomonas facilis. These results suggest that gentamicin-resistant determinant of Tn3-aac(3)II structure was widely distributed in the gentamicin-resistant bacteria.

Integration and Expression of BaciZlus thun'ngiensis Crystal Protein Gene in Chromosomal DNA of Pseudomonas Strains Using Transposon Tn5 (Transposon Tn5에 의한 Bacillus thuringiensis 독소단백질 유전자의 Pseudomonas 내로의 도입 및 발현)

  • 신병식;구본탁;박승환;김정일
    • Microbiology and Biotechnology Letters
    • /
    • v.19 no.1
    • /
    • pp.25-30
    • /
    • 1991
  • The crystal protein gene (cp) of Bacillus tizuringienszs subsp. liuvstaki (B.t.k.) HI173 was subcloned into HanzHI site of central region (Tn5-cp) or BglII site of IS50L region (IS50L-cp) in Tn5, and transposed into the chromosomal DNA of five strains of root-colonizing Pseudomonas. The expression of cp gene in Acwiomoncrs transconjugants was demonstrated by immunoblot analysis and bioassay against larvae of the Hyphantria cunea.

  • PDF

A Study on the Measurement and Determination of External Loop Impedance on TN-C-S System (TN-C-S 접지계통에서 외부 루프 임피던스의 실측 및 기준값 설정에 관한 연구)

  • Yi, Geon-Ho;Jung, Jin-Soo;Moon, Hyun-Wook;Kim, Sun-Gu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.8
    • /
    • pp.1163-1168
    • /
    • 2013
  • The maximum allowable value of loop impedance($Z_s$) to secure the operation of overcurrent protective devices and the safety for indirect contact is a very important in TN-C-S system. The loop impedance is divided into inner loop impedance which consumer can adjust and external loop impedance($Z_e$) which only electric operator can adjust. Thus, an external loop impedance which limits to less than a certain value is a very important factor for human body protection against electric shock in TN-C-S system. The concept of loop impedance($Z_s$) is recently introduced to the domestic, the study about external loop impedance is yet insufficient. However, the study about the reference impedance as specified by the IEC 60725 standard to improve the quality and reliability of the power supply is being made. In this paper, reference value of external loop impedance($Z_e$) to meet domestic environment will be proposed by the nationwide measurement and statistical analysis.

Personnel Safety Related to Disconnection of PEN Conductor in TN-C-S System (TN-C-S계통에서 PEN도체 단선이 인체안전에 미치는 영향)

  • Kim, Jung-Cheol;Lee, Kyu-Sun;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.5
    • /
    • pp.58-64
    • /
    • 2012
  • In electric power supply systems, an earthing system determines the electric potential of the conductors related to that of the Earth's surface. The choice of earthing system has implications for the safety of the power supply systems. There are considerably different regulations for earthing (grounding) systems in each country. A protective earth(PE) conductor ensures that all exposed conductive surfaces are at the same electric potential as the earth surface. This paper deals with that when PEN conductor of TN-C-S system is disconnected, dangerous touch voltage causes personnel body to be harmed and human being's property to be damaged seriously. For this reason, this paper explains how serious problems can occur when the fault current flows. As a consequence, we can understand how we can design earthing system properly to ensure the personnel safety against earth faults. The result shows the way that TN-C-S system can be applied safely in Korea.

Isolation and Characterization of Tn5 Insertion Mutants of Pseudomonas fluorescens Antagonistic to Rhizoctonia solani (Rhizoctonia solani 길항세균 Pseudomonas fluorescens의 Tn5 삽입 돌연변이주 분리 및 특성)

  • 박서기;박기범;김기청
    • Korean Journal Plant Pathology
    • /
    • v.10 no.1
    • /
    • pp.39-46
    • /
    • 1994
  • Pseudomonas fluorescens Biovar III strains S-2 antagonistic to Rhizoctonia solani was subjected to Tn5 mutagenesis by the transposon vector pGS9. Ampicillin and kanamycin resistant (Ampr, Kmr) transconjugants were recovered at a frequency of 1.3$\times$10-7 per initial recipient cell, when recipient cells were washed twice in TE buffer before conjugation. Of the ca. 3000 transconjugants, a frequency of noninhibitory (Inh-), nonfluorescent (Flu-) and auxotorphic (Pro-) mutants were 0.27%, 0.47% and 0.40%, respectively. In these mutants, all Inh- mutants showed the same colony morphology as wild type, whereas all Flu- and Pro- mutants inhibited the growth of R. solani. These mutants were also susceptible to chloramphenicol, indicating only the Tn5 element, except for parts of pGS9, was integrated into the recipient genome. In a Southern blot analysis, the Tn5 element inserted into one site on the chromosome for each of the chosen mutants. However, Tn5 insertion sites of Inh-, and Pro- mutants were differed in each other. These indicate that the genes essential for R. solani inhibition, fluorescent production and auxotrophic are chromosomally located, but not linked to each other.

  • PDF