• Title/Summary/Keyword: TN-C system

Search Result 82, Processing Time 0.03 seconds

The Application Method of a Protection Conductor for the Prevention of Electric Shock in England (감전사고 예방을 위한 영국의 보호도체 적용 방법)

  • Jung, Jin-Soo;Jung, Jong-Wook;Han, Woon-Ki;Lee, Jun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2216-2217
    • /
    • 2008
  • This paper write about earth system for the prevention electric shock and a protection of equipment in england. The IEC60364 and BSI(British Standards Institution) define earthing method(IT, TT, TN-C, TN-S, TN-C-S)-BSI is british standards and in case of england almost use the TN system. TN system can classify TN-S & TN-C-S(PME). The findings on survey in england are used the TN-S system and TN-C-S system about 70% and residue 30% are used TT system and IT system from the exiting state of things.

  • PDF

The Comparison and Analysis about Earth System based on IEC60364 (IEC 60364 기반 접지계통 비교 분석)

  • Jung, Jin-Soo;Han, Woon-Ki;Kim, Oh-Hwan;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.56-62
    • /
    • 2010
  • This paper describes the analysis of loop impedance characteristics by impedance alteration of protective conductors and operating characteristics of electric leakage circuit breaker by each earth systems(TT system, TN-S system and TN-C system) in IEC 60364. As a result, loop Impedance was affected by resistance & inductance. The current& voltage characteristics about earth system were identified that the TN-S system was high fault current & low touch voltage. TN-C system was almost same the TN-S system but TT system was low fault current & high touch voltage.

Hazards and Solutions of Loss of the PEN Conductor in TN-C-S System (TN-C-S계통에서 PEN도체의 단선고장의 위험성 및 보호대책)

  • Lee, Bok-Hee;Lee, Kyu-Sun;Ahn, Chang-Hwan;Kim, Han-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.113-120
    • /
    • 2007
  • This paper presents the electric shock hazards and solutions of loss of the combined protective and neutral (PEN) conductor in TN-C-S system. In order to mitigate the touch voltage on exposed-conductive-parts in a break in the PEN conductor, the touch voltages on exposed-conductive-parts in a break in the PEN conductor were experimentally investigated as a function of the ground resistances of the source grounding electrode and customer's additional grounding electrode. As a result, the equipotential bonding is one of important requirements for installations supplied by TN-C-S system. A solution of mitigating the touch voltages on exposed-conductor-parts caused by a loss of the PEN conductor would be the installation of the additional grounding electrode at the customer's service entrance. The ground resistance of additional grounding electrode necessary to limit the touch voltage to a safety voltage of less than 50[V] depends on the load and circuit parameters. In addition, the undervoltage sensing devices oner affordable solutions to detect a loss of the PEN conductor in TN-C-S system.

Personnel Safety Related to Disconnection of PEN Conductor in TN-C-S System (TN-C-S계통에서 PEN도체 단선이 인체안전에 미치는 영향)

  • Kim, Jung-Cheol;Lee, Kyu-Sun;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.5
    • /
    • pp.58-64
    • /
    • 2012
  • In electric power supply systems, an earthing system determines the electric potential of the conductors related to that of the Earth's surface. The choice of earthing system has implications for the safety of the power supply systems. There are considerably different regulations for earthing (grounding) systems in each country. A protective earth(PE) conductor ensures that all exposed conductive surfaces are at the same electric potential as the earth surface. This paper deals with that when PEN conductor of TN-C-S system is disconnected, dangerous touch voltage causes personnel body to be harmed and human being's property to be damaged seriously. For this reason, this paper explains how serious problems can occur when the fault current flows. As a consequence, we can understand how we can design earthing system properly to ensure the personnel safety against earth faults. The result shows the way that TN-C-S system can be applied safely in Korea.

Personnel safety related to a loss of PEN conductor in TN-C-S system (TN-C-S계통에서 PEN도체 단선이 인체안전에 미치는 영향)

  • Kim, Jung-Cheol;Lee, Bok-Hee;Lee, Kyu-Sun;Joe, Jung-Hyun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.59-62
    • /
    • 2009
  • In electrical power supply systems, an earthing system determines the electrical potential of the conductors relative to that of the Earth's conductive surface. The choice of earthing system has implications for the safety of the power supply. Note that regulations for earthing (grounding) systems vary considerably among different countries. A protective earth(PE) connection ensures that all exposed conductive surfaces are at the same electrical potential as the surface of the Earth, This paper investigates that when PEN conductor of TN-C-S system is disconnected, dangerous touch voltage is caused at personnel body. According to this paper, we can understand that when TN-C-S system is applied in Korea, what we should set up to ensure the personnel safety from fault current.

  • PDF

Evaluation of the Protection Performance of TT and TN Systems for Low-Voltage Consumers Against Lightning Surges (저압수용가에 공급하는 TT, TN계통의 뇌서지에 대한 보호성능의 평가)

  • Lee, Kyu-Sun;Choi, Jong-Hyuk;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.67-74
    • /
    • 2010
  • Most of domestic low-voltage consumers are supplied from the TN-C system of KEPCO, but their load installations have established according to the national statutory standard for electrical installations based on the TT system. In this work, to propose the proper system earthing arrangements of ensuring the protection of information-technology equipment against lightning surges, the protection performance of TT and TN systems against lightning surges was investigated. As a result, when lightning surge was injected to the neutral line of distribution system, the potential difference between the equipment earth terminal and neutral point of low-voltage mains in a TT system was significantly raised. The TT system is not advised due to the risk of damage to the sensitive computer equipment. Main equipotential bonding is an important requirement for protection of low-voltage installations against lightning surges. The TN system provides the best means to reduce the incoming lightning surges through the neutral line of low-voltage service systems. In addition, It is highly recommended to install the additional earthing at the service position of low-voltage consumers.

A Study on the Measurement and Determination of External Loop Impedance on TN-C-S System (TN-C-S 접지계통에서 외부 루프 임피던스의 실측 및 기준값 설정에 관한 연구)

  • Yi, Geon-Ho;Jung, Jin-Soo;Moon, Hyun-Wook;Kim, Sun-Gu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.8
    • /
    • pp.1163-1168
    • /
    • 2013
  • The maximum allowable value of loop impedance($Z_s$) to secure the operation of overcurrent protective devices and the safety for indirect contact is a very important in TN-C-S system. The loop impedance is divided into inner loop impedance which consumer can adjust and external loop impedance($Z_e$) which only electric operator can adjust. Thus, an external loop impedance which limits to less than a certain value is a very important factor for human body protection against electric shock in TN-C-S system. The concept of loop impedance($Z_s$) is recently introduced to the domestic, the study about external loop impedance is yet insufficient. However, the study about the reference impedance as specified by the IEC 60725 standard to improve the quality and reliability of the power supply is being made. In this paper, reference value of external loop impedance($Z_e$) to meet domestic environment will be proposed by the nationwide measurement and statistical analysis.

EO Performances of the Ion Beam Aligned TN-LCD on a Diamond-like-Carbon Thin Film Surface

  • Hwang, Jeoung-Yeon;Jo, Yong-Min;Seo, Dae-Shik;Rho, Soon-Joon;Baik, Hong-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.497-499
    • /
    • 2003
  • Electro-optical (EO) performances of the ion beam aligned twisted nematic (TN)-liquid crystal display (LCD) with oblique ion beam exposure on the DLC thin film surface were studied. An excellent voltage-transmittance (VT) curve of the ion beam aligned TN-LCD was observed with oblique ion beam exposure on the DLC thin film surface for 1 min. Also, a faster response time for the ion beam aligned TN-LCD can be achieved with oblique ion beam exposure on the DLC thin film surface for 1 min can be achieved.

  • PDF

Assessment Method and Calculations for Protective Conductor of TN-S System and IEC 60364 Application (IEC 60364 적용 및 TN-S 시스템에서 보호 도체 산정 및 적정성에 관한 연구)

  • Kim, Gi-Hyun;Lee, Ju-Chul;Choi, Young-Kyu;Kim, Han-Su;Lee, Young-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.86-91
    • /
    • 2012
  • A conductor has been produced according to IEC standard and low voltage electrical facility has been installed according to IEC 60364. So we must comply with international standard for design, construction and inspection. But because of many related and varied standards, it is difficult to apply to design and inspect for electrical equipment. We researched the necessity of design guide which is detailed and systematization from survey. For detailed design guide, we suggest calculation method of protective conductor cross-sectional area at TN-S system according to BS 7671 regulation and KS C IEC 60364 standard.

Problems and Improvement Method of Grounding System in Electrical Facilities (건축전기설비에 적용되는 접지시스템 문제점과 개선방안)

  • Chung, Young-Ki;Kwak, Hee-Ro;Shin, Hyo-Sub;Chung, Chun-Byoung;Nam, Taik-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.47-50
    • /
    • 2001
  • Presently the Korean grounding system uses TN system, multi-grounding method with TT independent grounding method. Nevertheless TN system can't exist with TT system in the technological terms. If they coexist, it causes ground-fault circuit not to operate, and brings about different electrical potential rise by customer system. It brings about serious problems for safety. This paper aims for improving method of grounding system based on the technical analysis on instances in foreign countries and Korea. Almost standards and construction manner were apt to be internationalized after WTO/TBT agreement was concluded. The internal grounding systems should meet the international criteria and reliability for safety, and be provided with technologically impeccable standards.

  • PDF