• Title/Summary/Keyword: TMS data

Search Result 195, Processing Time 0.026 seconds

Efficiency Study of Measurement Method by Flow Duration (유황별 유속측정 방법에 따른 유효성 연구)

  • Ham, Sang In;Lee, Jeong Hwan;Kim, Dae Young;Ha, Don Woo;Kim, Yoon Soo;Jung, Kang-Young;Lee, Yeong Jae;Kim, Gyeong Hyeon;Kim, Young Suk
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.5
    • /
    • pp.462-469
    • /
    • 2018
  • There are differences in method and cycle of flow rate survey depending on purpose of the operating department. To verify and use results of flow data according to the purpose, flow data of the directly measured and tele monitoring system were compared to verify validity. Flow measurement in the Ministry of Environment is aimed at setting up a standard flow of target water quality for water quality management and securing flow data of low and normal water level seasons for water quality evaluation. In this study, correlation analysis result ($R^2$) of same time zone data by direct measurement and tele monitoring system (TMS) at Seombon D point, a unit watershed of Seomjin river, for six years ('10 ~ '15) according to implementation of Total Daily Maximum Load (TDML) was wading 0.716, boating 0.962 and on bridge 0.943, and effectiveness of measurement method was verified by characteristics of flow duration as a season of dry and low-water; normal and high water are appropriate for wading, boating, and on bridge respectively. Results revealed it is reasonable to use directly measured results using the wading and boating method for low water level and dry seasons, and TMS data for rainy seasons. It can be used important data for future policy decisions.

Implementation of Tilting Management System of TTX (틸팅 차량의 열차 관리 시스템의 구현)

  • Kim Hyung-Chul;Choi Jae-Ho
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.157-162
    • /
    • 2005
  • This paper describes the system implementation of TMS(Train Management System) to be applied to a TTX(Korea Tilting eXpress). For better safety and reliability of vehicle, increased quantity and fast transmission of data between TC(Train Computer) and CC(Car Computer) and control equipment of train is required. To satisfy these requirements, this system uses RTOS(Real Time OS) so that do realtime data management, And it is implemented to minimize the noise inflow and a signal level reduction of the communication line. Also it is designed to suitable interface of a TTX vehicle and is verified by laboratory test.

  • PDF

DSP Implementation of Speech Enhancement System Using Microphone Array with Adaptive Post-processing (적응 후처리 과정을 갖는 마이크로폰 배열을 이용한 잡음제거기의 DSP 구현)

  • 권홍석;김시호;배건성
    • Proceedings of the IEEK Conference
    • /
    • 2002.06d
    • /
    • pp.413-416
    • /
    • 2002
  • In this paper, a speech enhancement system using microphone array with adaptive Post-Processing is implemented in real-lime with TMS320C6201 DSP. It consists of delay-and-sum beamformer and adaptive post-processing filters with NLMS (Normalized Least Mean Square) algorithm. THS1206 ADC is used for collection of 4-channel microphone signals. Sizes of program memory, data ROM and data RAM of the implemented system are 15,744, 748 and 47,540 bytes, respectively. Finally 21.839${\times}$106 clocks per second is required for real-time operation.

  • PDF

Development of NORSOK T-100-based telecom management system for off-shore installation (NORSOK T-100 기반의 해양플랜트용 TMS 응용 소프트웨어 개발)

  • Mun, Seong-Mi;Jang, Won-Seok;Park, Su-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.210-216
    • /
    • 2016
  • Malfunctioning of telecom systems can have serious implications on the safe navigation and operation of vessels and off-shore plants. Most safety-related accidents incur significant monetary damages and pollution due to complicated arrangements of the working environments and facilities. Therefore, an automated monitoring system that can collect data from configured telecom equipment connected to a network based on IP is required to ensure safe navigation and operation of such crucial institutions. This paper reports a list of such system requirements, system functions, and user-centered requirements based on the NORSOK T-100 (a standard of telecom management system). These findings were made through research with the newly designed and developed telecom management system (TMS). The TMS was tested by a testbed configured with CCTV, PA/GA, and other network equipment.

Development of Automatic Water Sampler with Sensor for Practical Measurement (현장측정용 센서부착 자동채수기 개발)

  • Kim, Jin-Hyok;Han, Seong-Kuk;Lee, Jin-Pill;Kim, Jae-Yong
    • Applied Chemistry for Engineering
    • /
    • v.21 no.6
    • /
    • pp.632-637
    • /
    • 2010
  • Considering the water quality regulation of total emission system which is enforced with hydro TMS and so on operating currently, automatic water sampler must be necessary in the viewpoint of national interest for conservation of water resources. This study aimed to develope automatic water sampler for the purpose of decreasing spends on foreign currency which is relied on import from abroad and upgrading the functional efficiency simultaneously. We have made an effort for developing results as follows with some cases. First, flow meter with a sensor equiped into automatic water sampler for field measurement which can perform linkage operation was developed. Second, remote-D/L system was developed which was able to monitor and store some transmitted data from practical measurement sensor. Also, automatic water sampler was developed in this research that operates in a sewage treatment plant, and finally, we confirmed that our system is able to apply to the field well.

Implementation of a Dynamic High-performance Notch Filter applying CIC Filter Scheme (CIC Filter 기법을 적용한 동적 고성능 Notch Filter 구현)

  • Shin, Seong-Kyun;Jeong, Won-Ho;Jang, Dong-Won;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.6
    • /
    • pp.1-8
    • /
    • 2011
  • Power Line Communication (PLC: Power Line Communication) to propagate the current power lines are in every household of the existing infrastructure is the most extensive network configuration. In addition, the cost required for network configuration, the advantage of almost zero for the investors and is sufficient to attract the attention of operators. The PLC is supply power to power lines used the voice and data communication technologies put it on KHz ~ tens of hundreds of high-frequency signal MHz. But because uses power lines as existing wireless communications systems will occurs interference. The notch filters of a common way to eliminate the interference are used. In this paper, a dynamic high-performance notch filter applying CIC filter performance was verified through MATLAB and was implemented using a TI's TMS320C6416T DSP board.

Real-time Implementation of MPEG-4 HVXC Encoder and Decoder on Floating Point DSP (부동 소수점 DSP를 이용한 MPEG-4 HVXC 인코더 및 디코더의 실시간 구현)

  • Kang, Kyeong-ok;Na, Hoon;Hong, Jin-Woo;Jeong, Dae-Gwon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.37-44
    • /
    • 2000
  • In this paper, we described the real-time implementation effort of MPEG-4 audio HVXC (Harmonic Vector eXcitation Coding) algorithm for very low bitrates, which has target applications from mobile communications to Internet telephony, on current high performance floating point TMS320C6701 DSP. We adopted a hardware structure for real-time operation. In order for software optimization, we used C- and assembly-language level optimizations for time-critical functional codes. Utilizing the internal program memory of the DSP as the program cache, the internal data memory overlap technique and DMA functionality, we could get a goal of realtime operation of HVXC codec both at 2 kbit/s and at 4 kbit/s. For an encoder at 2 kbit/s, the optimization ratio to original code is about 96 %. Finally, we got the subjective quality of MOS 2.45 at 2 kbit/s from an informal quality test.

  • PDF

A DSP-based Controller for a Small Humanoid Robot (DSP를 사용한 소형 인간형 로봇의 제어기)

  • Cho Jeong-San;Sung Young-Whee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.6 no.4
    • /
    • pp.191-197
    • /
    • 2005
  • Biped walking is the main feature of a humanoid robot. In a biped walking robot, there are many actuators to be controlled and many sensors to be interfaced. In this paper, we propose a DSP-based controller for a miniature biped walking robot with 21 RC servo motors. The proposed controller has a hierarchical structure; a host PC, a DSP-based main controller, and an auxiliary controller with an FPGA chip. The host PC generates and transmits the robot walking data for given walking parameters such as stride, walking period, etc. The main controller implemented with a TMS320LF2407A controls 21 RC servo motors via the auxiliary controller. We also perform some experiments for balancing motion and walking on a slope terrain with interfacing a 2-axis acceleration sensor and a TMS320LF2407A.

  • PDF

A Fault Detecting Scheme for Short-Circuited Turn in a Permanent Magnet Synchronous Motor through a Current Harmonic Monitoring (전류 고조파 관찰을 통한 영구자석 동기전동기의 권선 단락 고장 진단 기법)

  • Kim, Kyeong-Hwa;Gu, Bon-Gwan;Jung, In-Soung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.167-178
    • /
    • 2010
  • To diagnose a stator winding fault caused by a short-circuited turn in a permanent magnet synchronous motor (PMSM), an on-line based fault detecting scheme during motor operation is presented. The proposed scheme is based on monitoring the second-order harmonic components in q-axis current obtained through the harmonic analysis and a winding fault is detected by comparing these components with those in normal conditions. The linear interpolation method is employed to determine harmonic data in arbitrary normal operating conditions. To verify the effectiveness of the proposed fault detecting scheme, a test motor to allow inter-turn short in the stator winding has been built. The entire control system including harmonic analysis algorithm and fault detecting algorithm is implemented using DSP TMS320F28335. The proposed scheme does not require any additional hardware and can effectively detect a fault during motor operation so long as the steady-state condition is satisfied.

The Customer Premise Platform for Processing Multimedia Data on the ATM network (ATM망의 멀티미디어 데이터 처리를 위한 가입자단 플랫폼)

  • Kim Yunhong;Son Yoonsik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.2 s.332
    • /
    • pp.89-96
    • /
    • 2005
  • In this paper, we propose a customer premise platform for processing multimedia data service on the ATM network. The proposed platform has a specific AAL2 processor that includes AAL2 protocol and scheduler algorithm so as to off-load large potion of burden from host processor and make it easy to process multimedia data from the ATM network in real time compared with conventional platform in which AAL/ATM tasks are processed by software. The ATS scheduler that is implemented based on 2-level time slot ring provides a simple and efficient method for scheduling data of VBR-rt, UBR and CBR traffics. TMS320C5402 DSP is used to process voice-related tasks such as voice compression and voice packet manupulation and AAL2 processor is implemented on $0.35\;{\mu}m$ process line. We implemented the customer premise equipment for VoDSL service and tested the proposed platform on a test bed network. The experimental results show that the proposed equipment has the call success rate of $97\%$ at least and provides voice service of toll-qualify.