• Title/Summary/Keyword: TM9

Search Result 637, Processing Time 0.027 seconds

Formation of Al3Ti From Mechanically Alloyed Hyper-Peritectic Al-Ti Powder (기계적 합금화법으로 제조된 과포정 Al-Ti 합금에서 Al3Ti 형성에 관한 연구)

  • Kim, Hye-Sung;Suhr, Dong-Soo;Kim, Gyeung-Ho;Kum, Dong-Wha
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.9 no.1
    • /
    • pp.1-11
    • /
    • 1996
  • Mechanical alloying is an effective process to finely distribute inert dispersoids in an Al-TM(TM is a transition metal) system. It has been considered that high melting point aluminides are formed by precipitation from supersaturated Al(Ti) powder. This analysis is based on the fact that much higher content of TM than the solubioity can be dissolved in alpha aluminum during the high energy ball milling. Thus, decomposition behavior of Ti in the Al(Ti) was considered very important. But it is confirmed that the higher portion of Ti than Al(Ti) solid solution is existed as nano-sized Ti particles in the MA powders by high energy ball nilling from the XRD spectrum and TEM analysis in this study. Therefore, the role of undissolved TM particles affect the formation of aluminides should be suitably considered. In this study, we present experimental observation on the formation of $Al_3Ti$ fron mechanical alloyed Al-Ti alloys in the hyperperitectic region. This study showed that, in the mechanically alloyed Al-20wt%Ti specimen, intermediate phase of cubic $Al_3Ti$ and tetragonal $Al_{24}Ti_8$ formed at $300{\sim}400^{\circ}C$ and $400{\sim}500^{\circ}C$, respectively, before the MA state reaches to equilibrium at higher temperatures. The formation behavior of $Ll_2-Al_3Ti$ is interpreted by interdiffusion of Al and Ti in solid state based on the fact that large amount of nano-sized Ti particles exist in the milled powder. Present analysis indicated undissolved Ti particles of nanosize should have played an important role initiation the formation of $Al_3Ti$ phase during annealing.

  • PDF

Novel Robust High Dynamic Range Image Watermarking Algorithm Against Tone Mapping

  • Bai, Yongqiang;Jiang, Gangyi;Jiang, Hao;Yu, Mei;Chen, Fen;Zhu, Zhongjie
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.9
    • /
    • pp.4389-4411
    • /
    • 2018
  • High dynamic range (HDR) images are becoming pervasive due to capturing or rendering of a wider range of luminance, but their special display equipment is difficult to be popularized because of high cost and technological problem. Thus, HDR images must be adapted to the conventional display devices by applying tone mapping (TM) operation, which puts forward higher requirements for intellectual property protection of HDR images. As the robustness presents regional diversity in the low dynamic range (LDR) watermarked image after TM, which is different from the traditional watermarking technologies, a concept of watermarking activity is defined and used to distinguish the essential distinction of watermarking between LDR image and HDR image in this paper. Then, a novel robust HDR image watermarking algorithm is proposed against TM operations. Firstly, based on the hybrid processing of redundant discrete wavelet transform and singular value decomposition, the watermark is embedded by modifying the structure information of the HDR image. Distinguished from LDR image watermarking, the high embedding strength can cause more obvious distortion in the high brightness regions of HDR image than the low brightness regions. Thus, a perceptual brightness mask with low complexity is designed to improve the imperceptibility further. Experimental results show that the proposed algorithm is robust to the existing TM operations, with taking into account the imperceptibility and embedded capacity, which is superior to the current state-of-art HDR image watermarking algorithms.

Bioequivalence of LG Clarithromycin Tablet to Klaricid Tablet (Clarithromycin 250 mg) (클래리시드 정(클래리스로마이신 250mg)에 대한 LG클래리스로마이신 정의 생물학적 동등성)

  • Kim, Soo-Jin;Sim, Young-Sun;Lim, Dong-Koo;Oh, In-Joon;Shin, Sang-Chul;Suh, Soon-Pal;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.29 no.3
    • /
    • pp.235-240
    • /
    • 1999
  • Bioequivalence of two clarithromycin tablets, the $Klaricid^{TM}$ (Ciba-Geigy Korea Ltd., Seoul, Korea) and the LG clarithromycin (LG Chemical Co., Ltd., Seoul, Korea), was evaluated according to the Korean Guidelines for Bioequivalence Test (KGBT 1998). Sixteen normal male volunteers $(20{\sim}26\;years\;old)$ were randomly divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After one tablet containing 250 mg of clarithromycin was orally administered, blood sample was taken at predetennined time intervals, and the concentrations of clarithromycin in serum were detennined using HPLC method with electrochemical detector. The pharmacokinetic parameters $(AUC_t,\;C_{max}\;and\; T_{max})$ were calculated and ANOVA was utilized for the statistical analysis of parameters. The results showed that the differences in $AUC_t$, $C_{max}$, and $T_{max}$ between two tablets based on $Klaricid^{TM}$ tablet were 4.06%,2.67% and -9.70%, respectively. The powers $(1-{\beta})$ for $AUC_t$, $C_{max}$ and $T_{max}$ were 83.53%, 92.34% and 96.64%, respectively. Detectable differences $({\Delta})$ and 90 % confidence intervals $(a=0.05) $were all less than ${\pm}20%$. All the parameters above met the criteria of KGBT 1998, indicating that LG clarithromycin tablet is bioequivalent to $Klaricid^{TM}$ tablet.

  • PDF

An Efficient Motion Search Algorithm for a Media Processor (미디어 프로세서에 적합한 효율적인 움직임 탐색 알고리즘)

  • Noh Dae-Young;Kim Seang-Hoon;Sohn Chae-Bong;Oh Seoung-Jun;Ahn Chang-Beam
    • Journal of Broadcast Engineering
    • /
    • v.9 no.4 s.25
    • /
    • pp.434-445
    • /
    • 2004
  • Motion Estimation is an essential module in video encoders based on international standards such as H.263 and MPEG. Many fast motion estimation algorithms have been proposed in order to reduce the computational complexity of a well-known full search algorithms(FS). However, these fast algorithms can not work efficiently in DSP processors recently developed for video processing. To solve for this. we propose an efficient motion estimation scheme optimized in the DSP processor like Philips TM1300. A motion vector predictor is pre-estimated and a small search range is chosen in the proposed scheme using strong motion vector correlation between a current macro block (MB) and its neighboring MB's to reduce computation time. An MPEG-4 SP@L3(Simple Profile at Level 3) encoding system is implemented in Philips TM1300 to verify the effectiveness of the proposed method. In that processor, we can achieve better performance using our method than other conventional ones while keeping visual quality as good as that of the FS.

Efficacy and Safety of ClearCutTM Knife H-type in Endoscopic Submucosal Dissection for Gastric Neoplasms: A Multicenter, Randomized Trial

  • Eun Jeong Gong;Hyun Lim;Sang Jin Lee;Do Hoon Kim
    • Journal of Gastric Cancer
    • /
    • v.23 no.3
    • /
    • pp.451-461
    • /
    • 2023
  • Purpose: Endoscopic submucosal dissection (ESD) is an effective treatment for early gastrointestinal neoplasms. However, this is a time-consuming procedure requiring various devices. This study aimed to evaluate the efficacy and safety of the ClearCutTM Knife H-type, which is an integrated needle-tipped and insulated-tipped (IT) knife. Materials and Methods: Between July 2020 and September 2021, 99 patients with gastric epithelial neoplasms scheduled for ESD at three tertiary care hospitals were randomly assigned to H-knife (ClearCutTM Knife H-type) or IT-knife (conventional IT knife) groups. Procedure times, therapeutic outcomes, and adverse events were analyzed. Results: A total of 98 patients (50 in the H-knife group and 48 in the IT-knife group) were analyzed. The median total procedure time was 11.9 minutes (range, 4.4-47.2 minutes) in the H-knife group and 12.7 minutes (range, 5.2-137.7 minutes) in the IT-knife group (P=0.209). Unlike the IT-knife group, which required additional devices in all cases, no additional devices were used in the H-knife group (P<0.001). En-bloc resection was performed for all lesions in both groups. The incidence of adverse events was not significantly different between groups (4.0% in the H-knife group vs. 8.3% in the IT-knife group; P=0.431). Conclusions: The newly developed hybrid device, the ClearCutTM Knife H-type, had comparable efficacy to the conventional IT knife for gastric ESD.

Evaluation of Real-time Measurement Liver Tumor's Movement and $Synchrony^{TM}$ System's Accuracy of Radiosurgery using a Robot CyberKnife (로봇사이버나이프를 이용한 간 종양의 실시간 움직임 측정과 방사선수술 시 호흡추적장치의 정확성 평가)

  • Kim, Gha-Jung;Shim, Su-Jung;Kim, Jeong-Ho;Min, Chul-Kee;Chung, Weon-Kuu
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.263-270
    • /
    • 2008
  • Purpose: This study aimed to quantitatively measure the movement of tumors in real-time and evaluate the treatment accuracy, during the treatment of a liver tumor patient, who underwent radiosurgery with a Synchrony Respiratory motion tracking system of a robot CyberKnife. Materials and Methods: The study subjects included 24 liver tumor patients who underwent CyberKnife treatment, which included 64 times of treatment with the Synchrony Respiratory motion tracking system ($Synchrony^{TM}$). The treatment involved inserting 4 to 6 acupuncture needles into the vicinity of the liver tumor in all the patients using ultrasonography as a guide. A treatment plan was set up using the CT images for treatment planning uses. The position of the acupuncture needle was identified for every treatment time by Digitally Reconstructed Radiography (DRR) prepared at the time of treatment planning and X-ray images photographed in real-time. Subsequent results were stored through a Motion Tracking System (MTS) using the Mtsmain.log treatment file. In this way, movement of the tumor was measured. Besides, the accuracy of radiosurgery using CyberKnife was evaluated by the correlation errors between the real-time positions of the acupuncture needles and the predicted coordinates. Results: The maximum and the average translational movement of the liver tumor were measured 23.5 mm and $13.9{\pm}5.5\;mm$, respectively from the superior to the inferior direction, 3.9 mm and $1.9{\pm}0.9mm$, respectively from left to right, and 8.3 mm and $4.9{\pm}1.9\;mm$, respectively from the anterior to the posterior direction. The maximum and the average rotational movement of the liver tumor were measured to be $3.3^{\circ}$ and $2.6{\pm}1.3^{\circ}$, respectively for X (Left-Right) axis rotation, $4.8^{\circ}$ and $2.3{\pm}1.0^{\circ}$, respectively for Y (Crania-Caudal) axis rotation, $3.9^{\circ}$ and $2.8{\pm}1.1^{\circ}$, respectively for Z (Anterior-Posterior) axis rotation. In addition, the average correlation error, which represents the treatment's accuracy was $1.1{\pm}0.7\;mm$. Conclusion: In this study real-time movement of a liver tumor during the radiosurgery could be verified quantitatively and the accuracy of the radiosurgery with the Synchrony Respiratory motion tracking system of robot could be evaluated. On this basis, the decision of treatment volume in radiosurgery or conventional radiotherapy and useful information on the movement of liver tumor are supposed to be provided.

A Comparative Study on the Herbage Utilization from Tall type and Tall+short type Mixtures by Korean Native Goats (상번초 및 상ㆍ하번초형 혼파초지의 산양에 의한 초류이용성 비교 연구)

  • 이형석;이인덕
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.23 no.2
    • /
    • pp.129-134
    • /
    • 2003
  • This study was conducted to investigate the effect of tall type mixtures(TM) and tall + short type mixtures(TSM) on nutritive utilization. DM intake, digestibility and utilization of nitrogen and energy of herbages from pastures by Korean native goats were determined. This experiment was conducted by total collection method in laboratory, 2000. The experimental herbage included two treatments: Tall type mixtures(orchardgrass, Potomac 40+tall fescue, Fawn 20+Festulolium braunii, Paulita 10+perennial ryegrass. Reveille 10+timothy, Climax 10+red clover, Kenblue 5+alfalfa, Vernal 5%), Tall+short type mixtures {orchardgrass, Potomac 40+tall fescue, Fawn 20+Kentucky bluegrass, New port(turf type) 10+redtop, Barricuda(turf type) 10+perennial ryegrass, Palmer III(turf type) 10+red fescue, Flyer II(turf type) 5+white clover, Regal 5%}. The voluntary dry matter(DM) intake of Korean native goats fed with herbages from tall+short type mixtures(TSM) was slightly higher than that of tall type mixtures(TM), but no difference was observed between TSM and TM(p > 0.05). The digestibility of DM, neutral detergent fiber, cellular contents and acid detergent fiber of herbage from TSM was slightly higher than that of TM, but no difference was detected between TSM and TM(p > 0.05). The utilization of nitrogen and energy by Korean native goats did not showed any difference in herbages from TSM and TM(p > 0.05). In conclusion, the herbage utilization by Korean native goats did not showed any significant difference. Thus, there is a possibility that turf grasses in mixtures can be used as a forage sources.

Structural and Kinetic Characteristics of 1,4-Dioxane-Degrading Bacterial Consortia Containing the Phylum TM7

  • Nam, Ji-Hyun;Ventura, Jey-R S.;Yeom, Ick Tae;Lee, Yongwoo;Jahng, Deokjin
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.11
    • /
    • pp.1951-1964
    • /
    • 2016
  • 1,4-Dioxane-degrading bacterial consortia were enriched from forest soil (FS) and activated sludge (AS) using a defined medium containing 1,4-dioxane as the sole carbon source. These two enrichments cultures appeared to have inducible tetrahydrofuran/dioxane and propane degradation enzymes. According to qPCR results on the 16S rRNA and soluble di-iron monooxygenase genes, the relative abundances of 1,4-dioxane-degrading bacteria to total bacteria in FS and AS were 29.4% and 57.8%, respectively. For FS, the cell growth yields (Y), maximum specific degradation rate ($V_{max}$), and half-saturation concentration ($K_m$) were 0.58 mg-protein/mg-dioxane, $0.037mg-dioxane/mg-protein{\cdot}h$, and 93.9 mg/l, respectively. For AS, Y, $V_{max}$, and $K_m$ were 0.34 mg-protein/mg-dioxane, $0.078mg-dioxane/mg-protein{\cdot}h$, and 181.3 mg/l, respectively. These kinetics data of FS and AS were similar to previously reported values. Based on bacterial community analysis on 16S rRNA gene sequences of the two enrichment cultures, the FS consortium was identified to contain 38.3% of Mycobacterium and 10.6% of Afipia, similar to previously reported literature. Meanwhile, 49.5% of the AS consortium belonged to the candidate division TM7, which has never been reported to be involved in 1,4-dioxane biodegradation. However, recent studies suggested that TM7 bacteria were associated with degradation of non-biodegradable and hazardous materials. Therefore, our results showed that previously unknown 1,4-dioxane-degrading bacteria might play an important role in enriched AS. Although the metabolic capability and ecophysiological significance of the predominant TM7 bacteria in AS enrichment culture remain unclear, our data reveal hidden characteristics of the TM7 phylum and provide a perspective for studying this previously uncultured phylotype.

The effect of adhesive thickness on microtensile bond strength to the cavity wall (와동벽에서 접착제의 두께가 미세인장 결합강도에 미치는 영향)

  • Lee, Hwa-Eon;Kim, Hyeon-Cheol;Hur, Bock;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.9-18
    • /
    • 2007
  • The purposes of this study were to examine the variability of adhesive thickness on the different site of the cavity wall when used total-etch system without filler and simplified self-etch system with filler and to evaluate the relationship between variable adhesive thickness and microtensile bond strength to the cavity wall. A class I cavity in six human molars was prepared to expose all dentinal walls. Three teeth were bonded with a filled adhesive, $Clearfil^{TM}$ SE bond ana the other three teeth were bonded with unfilled adhesives, $Scotchbond^{TM}$ Multi Purpose. Morphology and thickness of adhesive layer were examined using fluorescence microscope. Bonding agent thickness was measured at three points along the axial cavity wall edge of cavity margin (rim). halfway down each cavity wall (h1f), internal angle of the cavity (ang). After reproducing the adhesive thickness at rim, h1f and ang, micro-tensile bond strength were evaluated. For both bonding agents, adhesive thickness of ang was significantly thicker than that of rim and h1f (P <0.05). As reproduced the adhesive thickness, microtensile bond strength was increased as adhesive thickness was increased in two bonding agents. Adhesive thickness of internal angle of the cavity was significantly thicker than that of the cavity margin and the halfway cavity wall for both bonding agents. Microtensile bond strength of the thick adhesive layer at the internal angle of the cavity was higher than that of the thin adhesive layer at 1,he cavity margin and the halfway cavity in the two bonding systems.

Positional uncertainties of cervical and upper thoracic spine in stereotactic body radiotherapy with thermoplastic mask immobilization

  • Jeon, Seung Hyuck;Kim, Jin Ho
    • Radiation Oncology Journal
    • /
    • v.36 no.2
    • /
    • pp.122-128
    • /
    • 2018
  • Purpose: To investigate positional uncertainty and its correlation with clinical parameters in spine stereotactic body radiotherapy (SBRT) using thermoplastic mask (TM) immobilization. Materials and Methods: A total of 21 patients who underwent spine SBRT for cervical or upper thoracic spinal lesions were retrospectively analyzed. All patients were treated with image guidance using cone beam computed tomography (CBCT) and 4 degrees-of-freedom (DoF) positional correction. Initial, pre-treatment, and post-treatment CBCTs were analyzed. Setup error (SE), pre-treatment residual error (preRE), post-treatment residual error (postRE), intrafraction motion before treatment (IM1), and intrafraction motion during treatment (IM2) were determined from 6 DoF manual rigid registration. Results: The three-dimensional (3D) magnitudes of translational uncertainties (mean ${\pm}$ 2 standard deviation) were $3.7{\pm}3.5mm$ (SE), $0.9{\pm}0.9mm$ (preRE), $1.2{\pm}1.5mm$ (postRE), $1.4{\pm}2.4mm$ (IM1), and $0.9{\pm}1.0mm$ (IM2), and average angular differences were $1.1^{\circ}{\pm}1.2^{\circ}$ (SE), $0.9^{\circ}{\pm}1.1^{\circ}$ (preRE), $0.9^{\circ}{\pm}1.1^{\circ}$ (postRE), $0.6^{\circ}{\pm}0.9^{\circ}$ (IM1), and $0.5^{\circ}{\pm}0.5^{\circ}$ (IM2). The 3D magnitude of SE, preRE, postRE, IM1, and IM2 exceeded 2 mm in 18, 0, 3, 3, and 1 patients, respectively. No association were found between all positional uncertainties and body mass index, pain score, and treatment location (p > 0.05, Mann-Whitney test). There was a tendency of intrafraction motion to increase with overall treatment time; however, the correlation was not statistically significant (p > 0.05, Spearman rank correlation test). Conclusion: In spine SBRT using TM immobilization, CBCT and 4 DoF alignment correction, a minimum residual translational uncertainty was 2 mm. Shortening overall treatment time and 6 DoF positional correction may further reduce positional uncertainties.