• Title/Summary/Keyword: TIP pulse sequence

Search Result 5, Processing Time 0.022 seconds

Efficient baseline suppression via TIP and modified DEPTH

  • Hyun, Namgoong
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.26 no.4
    • /
    • pp.51-58
    • /
    • 2022
  • The baseline flattened NMR spectrum has been achieved by several methodologies including pulse manipulation with a series of phase cycling. The background signal inherent in the probe is also main source of baseline distortion both in solution and solid NMR. The simple direct polarization with 90° pulse flipping the magnetization from the z-axis onto the receiver coil requires the strong rf pulse enough to encompass the wide frequency range to excite the resonance of interest nuclei. Albeit the perfect polarization 90° pulse, the signal from the unwanted magnetic fields such as background signal can not be completely suppressed by suitable phase cycling. Moreover, slowly baseline wiggling signal from the low 𝛾 nuclei is not easy to eliminate with multiple pulse manipulation. So there is still need to contrive the new scheme for that purpose in an adroit manner. In this article new triple pulse excitation schemes for TIP and modified DEPTH pulse sequence are analytically examined in terms of arbitrary phase and flip angle of pulse. The suitable phase cycling for these pulse trains is necessary for the good sensitivity and resolution of the spectrum. It is observed that the 13C sensitivity TIP experiment is almost equal to the CP/MAS with modified DEPTH sequence, both of which are applicable to both solid and solution state NMR.

The Suppressing of MR Image Artifacts using Phases Cycling in Fast SE Sequence

  • Shin, Yong-Jin;Jeong, Gwang-Woo
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.2 no.1
    • /
    • pp.59-65
    • /
    • 1998
  • The correction of image artifacts due to misadjustment in tuning of RF coils (tip angle) and in the RF single sideband spectrometer was investigated using phase cycling of the $\pi$/2 and $\pi$ pulses in spin-echo sequences. A general procedure was developed for the systematic design of phase cycles that select desirable coherence transfer pathways. To analyze a phase cycling sequence, changes in the coherence level and phase factor for each RF pulse in the spin-echo cycle must be determined. Four different phase cycling schemes (FIXED, ALTERNATE, FORWARD, REVERSED) to suppress unwanted signal components such as mirror and ghost images were evaluated using two signal acquisitions. When the receiver phase factor is cycled counter-clockwise (REVERSED), these artifacts are completely removed.

  • PDF

New Generalized SVPWM Algorithm for Multilevel Inverters

  • Kumar, A. Suresh;Gowri, K. Sri;Kumar, M. Vijay
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1027-1036
    • /
    • 2018
  • In this paper a new generalized space vector pulse width modulation scheme is proposed based on the principle of reverse mapping to drive the switches of multilevel inverters. This projected scheme is developed based on the middle vector of the subhexagon which holds the tip of the reference vector, which plays a major role in mapping the reference vector. A new approach is offered to produce middle vector of the subhexagon which holds tip of the reference vector in the multilevel space vector plane. By using middle vector of the subhexagon, reference vector is linked towards the inner two level sub-hexagon. Then switching vectors, switching sequence and dwell times corresponding to a particular sector of a two-level inverter are determined. After that, by using the two level stage findings, the switching vectors related to exact position of the reference vector are directly generated based on principle of the reverse mapping approach and do not need to be found at n level stage. In the reverse mapping principle, the middle vector of subhexagon is added to the formerly found two level switching vectors. The proposed generalized algorithm is efficient and it can be applied to an inverter of any level. In this paper, the proposed scheme is explained for a five-level inverter and the performance is analyzed for five level and three level inverters through MATLAB. The simulation results are validated by implementing the propose scheme on a V/f controlled three-level inverter fed induction motor using dSPACE control desk.

A Defect Detection of Thin Welded Plate using an Ultrasonic Infrared Imaging (초음파 열화상 검사를 이용한 박판 용접시편의 결함 검출)

  • Cho, Jai-Wan;Chung, Chin-Man;Choi, Young-Soo;Jung, Seung-Ho;Jung, Hyun-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.11
    • /
    • pp.1060-1066
    • /
    • 2007
  • When a high-energy ultrasound propagates through a solid body that contains a crack or a delamination, the two faces of the defect do not ordinarily vibrate in unison, and dissipative phenomena such as friction, rubbing and clapping between the faces will convert some of the vibrational energy to heat. By combining this heating effect with infrared imaging, one can detect a subsurface defect in material efficiently. In this paper a detection of the welding defect of thin SUS 304 plates using the UIR (ultrasonic infrared imaging) technology is described. A low frequency (20kHz) ultrasonic transducer was used to infuse the welded thin SUS 304 plates with a short pulse of sound for 280ms. The ultrasonic source has a maximum power of 2kW. The surface temperature of the area under inspection is imaged by a thermal infrared camera that is coupled to a fast frame grabber in a computer. The hot spots, which are a small area around the defect tip and heated up highly, are observed. From the sequence of the thermosonic images, the location of defective or inhomogeneous regions in the welded thin SUS 304 plates can be detected easily.

Usefulness Comparative Experimental Study of the CT and MR Imaging in the Dog Clonorchiasis (잡견 간흡충증의 전산화단층촬영과 자기공명영상의 유용성에 관한 실험적 연구)

  • Goo, Eun-Hoe;Kweon, Dae-Cheol;Kim, Dong-Sung;Choi, Chun-Kyu
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.33-39
    • /
    • 2003
  • Purpose : Be aware of clinical possibilities on image quality by comparison of contrast-enhanced dynamic CT and MR imaging applied of MIP technique after the experimentally induced clonorchasis infection in dogs. Materials and Method : Twenty mongrel dogs prepared in zoo-laboratory were followed up with serial CT scans and MR imaging for 13 weeks after the experimental infection in liver. Two-phase helical CT was acquired in the supine position with the following scanning parameters. After the injection of contrast material, the arterial phase was initiated using a bolus-racking method. The portal phase scan was started 15 seconds after the arterial phase scan. CT protocol was determined after single level dynamic scans. MR imaging used the CP body coil and images get a 2D image using HASTE, FLASH, TSE pulse sequence. Bile duct MR imaging were obtained in three plans. Then each image was post processed by using target MIP algorithm. Two experimentation above, as a method of evaluation, one pathologist, three radiologist and five radiological technologist were analyzed visually for evaluation of following findings, enhancement of the bile duct wall, dilatation of bile duct tip, liver parenchyma, background suppression. Results : Five dogs was died of a disease after the infection, the rest one else shows the chronic dilatation of the intrahepatic bile duct with CT and MR imaging. Contrast administration of CT shows the contrast-enhanced of the bile duct walls with live parenchyma. MR imaging calculated of CNR and CR from pulse sequence for comparative evaluation and shows the pattern of the intrahepatic bile duct, dilatation of bile duct tip using MIP technique. CNR of the clonorchiasis, HASTE was $16{\pm}0.83$, TSE $7.06{\pm}3.0$, FLASH $1.19{\pm}0.2$ and CR, HASTE was 73.3%, TSE 62.3%, FLASH 6.4%. Conclusion : CT and MR imaging is very usefulness in diagnosis of dog clonorchiasis.