• Title/Summary/Keyword: TIN Elements

Search Result 75, Processing Time 0.017 seconds

How can the development of neighbourhood renewal strategies in Malaysia be informed by best practice and transferable lessons from developed countries (선진국 도시재생 사례비교를 통한 말레이시아 주거재생 전략의 모색)

  • Tin, Wan Jiun;Lee, Seok-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.469-486
    • /
    • 2017
  • Economy-based urban redevelopment is the main priority in Malaysia, but has resulted in social problems such as gentrification, loss of heritage and identity, inequity, etc. Hence, it is crucial for the government to seek other alternatives rather than being solely reliant on urban redevelopment. Neighborhood renewal is a strategy involving the integration of redevelopment, rehabilitation, revitalization and preservation that aims to improve deprived areas using a more holistic approach. The aim of this paper is to review the neighborhood renewal policies in developed countries and to identify those elements that can be adopted in Malaysia. This study is conducted via a literature review. It was found that neighborhood renewal which integrates people-based, place-based and system-based policies highlights the importance of diversity, thereby aiming for resource optimization, community engagement and urban governance with the focal point of the fair, equity and systematic provision of resources. This paper concluded that neighborhood renewal in Malaysia should be initiated by locals with an emphasis on real local participation and a sustainable funding system. The government and local authorities should be observers rather than implementers.

Manufacturing technique and provenance Analysis of Bronze Artefacts excavated from Pungnap earthen fortress (풍납토성 출토 청동유물의 제작기술 및 납 원료의 산지추정)

  • Han, Woo Rim;Kim, So Jin;Han, Min-su;Hwang, Jin-ju;Lee, Eun-woo
    • Korean Journal of Heritage: History & Science
    • /
    • v.48 no.2
    • /
    • pp.110-119
    • /
    • 2015
  • Bronzes, Earthenwares and various artifacts were excavated from Pungnap earthen fortress in the early Baekje age in Korea. This study was performed in order to identify the manufacture technology of bronze artefacts and provenance of lead in bronzes. Microstructure and chemical composition results show that 3 of them are Cu-Sn-Pb alloys in which an intentional lead addition was carried out and one is tin bronze showing straight twin structure within crystal grains. Also $CuFeS_2$ or $Cu_5FeS_4$ was used as raw materials through the detection of S and Fe as trace elements. The lead isotope results could be matched with one of the zones of southern Korea and China on the East Asian map. This results shows that data were plotted either in zone 2 or zone 3 of the South Korean galena map. However, one of bronze artifacts was matched with the zone of Northern China.

Antifouling Effect of an Ultrasonic System Operating at Different Frequencies (주파수 변동에 따른 초음파방오장비의 파울링제거효과)

  • Bae, Jin-Woo;Park, Guan-Sik;Ru, Myung-Lok;Park, Goun-Ha
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.5
    • /
    • pp.609-616
    • /
    • 2019
  • When the fouling of a vessel occurs, its resistance at sea increases and there is a corresponding increase in fuel consumption. The maintenance cost of the vessel also increases because it is time-consuming to remove the fouling. To solve this problem and minimize environmental contamination of sea-water, there have been recent developments in anti-fouling paints as self-polishing copolymers that not include toxic elements such as tin. When these conventional techniques are applied to vessels, polishing is promoted during the operation whereby friction or vibration with seawater occurs. This leads to enhanced anti-fouling performance. However, when fouling is intensified such as during an anchorage, there is no flow of seawater and polishing is suppressed. This leads to a deterioration of the performance of anti-fouling. To solve these problems, we developed a system that induces vibration in a vessel during anchorage. As such, the deterioration of polishing due to insuf icient flow of seawater is inhibited. The reliability of the ultrasonic antifouling system was evaluated by calculating its repeatability. The removal efficiency of fouling of the proposed system was qualitatively evaluated using test specimens. The test revealed that the value of the coefficient of variation for the reproducibility of the frequency and amplitude was 0.2 % and 4.0 % on average. The degree of fouling of the specimens was the highest at 73.3 g in the No.5 sepcimen. Moreover, efficiency of fouling removal was 93.2 % on average compared to the specimens without the proposed system.

Optically transparent ultrasound transducers for combined ultrasound and photoacoustic imaging: A review (초음파-광음향 융합 영상을 위한 투명 초음파 변환기)

  • Shunghun Park;Jin Ho Chang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.441-451
    • /
    • 2023
  • Ultrasound transducers are an essential component of combined photoacoustic and ultrasound imaging systems and play an important role in image evaluation. However, ultrasound transducers are opaque; therefore, light must bypass the ultrasound transducer to reach the target point to produce a photoacoustic image. Providing different paths for the optical and acoustic signals results in a complicated system design, increasing the system volume. To overcome these problems, an optically Transparent Ultrasound Transducer (TUT) was developed. Unlike conventional opaque ultrasound transducers, optically TUT can be fabricated by a variety of manufacturing methods and they are suitable for use with specific piezoelectric elements and serve various purposes. In this study, a comparative analysis of the results of using Lithium Niobate (LNO), Lead Magnesium Niobate-Lead Titanate (PMN-PT), and Polyvinylidene Difluoride (PVDF), which are materials used in piezoelectric element-based TUT. LNO is a piezoelectric element widely used in TUT, and PMN-PT has been actively studied recently with a higher transmission and reception rate than LNO. Existing TUT have lower ultrasound resolution than photoacoustic resolution, but they have recently been manufacturing focused TUT with high ultrasound resolution using PVDF. A comparative analysis of the production results of these TUT was performed.

Development of Lead Free Shielding Material for Diagnostic Radiation Beams (의료영상용 방사선방호를 위한 무납차폐체 개발)

  • Choi, Tae-Jin;Oh, Young-Kee;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.232-237
    • /
    • 2010
  • The shielding materials designed for replacement of lead equivalent materials for lighter apron than that of lead in diagnostic photon beams. The absorption characteristics of elements were applied to investigate the lead free material for design the shielding materials through the 50 kVp to 110 kVp x-ray energy in interval of 20 kVp respectively. The idea focused to the effect of K-edge absorption of variable elements excluding the lead material for weight reduction. The designed shielding materials composited of Tin 34.1%, Antimon 33.8% and Iodine 26.8% and Polyisoprene 5.3% gram weight account for 84 percent of weight of lead equivalent of 0.5 mm thickness. The size of lead-free shielder was $200{\times}200{\times}1.5\;mm^3$ and $3.2\;g/cm^3$ of density which is equivalent to 0.42 mm of Pb. The lead equivalent of 0.5 mm thickness generally used for shielding apron of diagnostic X rays which is transmitted 0.1% for 50 kVp, 0.9% for 70 kVp and 3.2% for 90 kVp and 4.8% for 110 kVp in experimental measurements. The experiment of transmittance for lead-free shielder has showed 0.3% for 50 kVp, 0.6% for 70 kVp, 2.0% for 90 kVp and 4.2% for 110 kVp within ${\pm}0.1%$. respectively. Using the attenuation coefficient of experiments for 0.5 mm Pb equivalent of lead-free materials showed 0.1%. 0.3%, 1.0% and 2.4%, respectively. Furthermore, the transmittance of lead-free shielder for scatter rays has showed the 2.4% in operation energy of 50 kVp and 5.9% in energy of 110 kVp against 2.4% and 5.1% for standard lead thickness within ${\pm}0.2%$ discrepancy, respectively. In this experiment shows the designed lead-free shielder is very effective for reduction the apron weight in diagnostic radiation fields.