• Title/Summary/Keyword: TI-201

Search Result 59, Processing Time 0.023 seconds

Capillary Electrophoresis Detection of Hydrogen Peroxide by Using Titanium Ion and 4-(2-thiazolylazo)resorcinol

  • Vu Phuong, Dong;Yoo, Hoon
    • International Journal of Oral Biology
    • /
    • v.42 no.4
    • /
    • pp.197-201
    • /
    • 2017
  • A novel method for the detection of hydrogen peroxide in aqueous solution was developed via reaction between $H_2O_2$, trivalent titanium ion ($Ti^{3+}$) and 4-(2-thiazolylazo) resorcinol (TAR), resulting in a ternary complex with a maximum UV absorbance at 530 nm. The CE detection of $H_2O_2$ was fast, sensitive and cost-effective without pretreatment procedures. $H_2O_2$ was detected within 15 min at 1 to $100{\mu}M$ range with the lowest detection limit at $1.0{\mu}M$. Under the optimized CE conditions, the concentration of $H_2O_2$ in coffee or tea extract was quantitatively determined. Our results show that CE detection of the ternary complex of $H_2O_2-Ti^{3+}$-TAR has potential applications for the detection of $H_2O_2$ in aqueous sources.

Fabrication of Bulk Metallic Glass Alloys by Warm Processing of Amorphous Powders (비정질 분말의 열간 성형법에 의한 벌크 비정질합금의 제조)

  • 이민하;김도향
    • Journal of Powder Materials
    • /
    • v.11 no.3
    • /
    • pp.193-201
    • /
    • 2004
  • 1960년 Au-Si계 합금에서 처음으로 비정질상이 급속 응고법에 의해 보고된 이래/sup 1)/ 지난 40년 간 많은 합금계에서 비정질상이 보고되어졌다. 대표적으로 Fe-, Ni-, Co기 합금 등 많은 합금계에서 비정질상이 보고되었으나, 비정질상의 형성을 위해서는 약 105 K/s이상의 높은 냉각속도를 필요로 하였다. 1980년대 수백 K/s의 낮은 냉각속도 하에서도 비정질상이 형성될 수 있는 다원계 합금(multi-component alloy)이 Mg-Ln-(Ni, Cu, Zn), Ln-Al-TM 합금에서 보고되어 졌으나 많은 관심을 받지 못하다가 1993년 Zr-Ti-Ni-Cu-Be 합금에서 수 ㎝ 크기의 비정질합금 제조가 보고되면서 전 세계적으로 많은 관심을 받게 되었다. Zr-Ti-Ni-Cu-Be계 벌크 비정질 합금이 보고된 후 Zr-(Nb,Pd)-Al-TM, Pd-Cu-Ni-P, Fe-Co-Zr-Mo-W-B, Ti-Zr-Ni-Cu-Sn등 여러 합금계에서 벌크 비정질 합금이 보고되었다. (중략)

Adsorption Characteristics of Arsenic on Composite Adsorbents using Recycled Aluminium Oxides and $TiO_2$ (재생 알루미늄 산화물과 $TiO_2$의 복합성형체를 이용한 비소 흡착 특성)

  • Min, Kyung-Chul;Lee, Seung-Mok;Kim, Keun-Han;Lee, Hee-Yong;Yang, Jae-Kyu;Park, Youn-Jong
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.2
    • /
    • pp.197-201
    • /
    • 2012
  • The objective of this study was to evaluate the removal efficiency of arsenite and arsenate using composite adsorbents with various mixing ratio of recycled aluminum oxides and $TiO_2$. From batch adsorption experiments, while the removal of As(III) was almost same with 4 different composite samples in the entire pH range, the removal of As(V) was substantially increased as the weight ratio of $TiO_2$ in composite samples reduced and showed anionic adsorption characteristics. Both adsorption of As (III) and As(V) on composite samples followed pseudo-second-order adsorption equation and C-3 showed faster reaction rate for the removal of arsenic. From the adsorption isotherm experiments, Langmuir isotherm explained well and the maximum adsorption capacities of arsenic were obtained with C-1.

Consideration of Normal Variation of Perfusion Measurements in the Quantitative Analysis of Myocardial Perfusion SPECT: Usefulness in Assessment of Viable Myocardium (심근관류 SPECT의 정량적 분석에서 관류정량값 정상변이의 고려: 생존심근 평가에서의 유용성)

  • Paeng, Jin-Chul;Lim, Il-Han;Kim, Ki-Bong;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.285-291
    • /
    • 2008
  • Purpose: Although automatic quantification software of myocardial perfusion SPECT provides highly objective and reproducible quantitative measurements, there is still some limitation in the direct use of quantitative measurements. In this study we derived parameters using normal variation of perfusion measurements, and tried to test the usefulness of these parameters. Materials and Methods: In order to calculate normal variation of perfusion measurements on myocardial perfusion SPECT, 55 patients (M:F = 28:27) of low-likelihood for coronary artery disease were enrolled and $^{201}TI$ rest/$^{99m}Tc$-MIBI stress SPECT studies were performed. Using 20-segment model, mean (m) and standard deviation (SD) of perfusion were calculated in each segment. As a myocardial viability assessment group, another 48 patients with known coronary artery disease, who underwent coronary artery bypass graft surgery (CABG) were enrolled. $^{201}TI$ rest/$^{99m}Tc$-MIBI stress / $^{201}TI$ 24-hr delayed SPECT was performed before CABG and SPECT was followed up 3 months after CABG. From the preoperative 24-hr delayed SPECT, $Q_{delay}$ (perfusion measurement), ${\Delta}_{delay}$ ($Q_{delay}$ - m) and $Z_{delay}$ (($Q_{delay}$ - m)/SD) were defined and diagnostic performances of them for myocardial viability were evaluated using area under curve (AUC) on receiver operating characteristic (ROC) curve analysis. Results: Segmental perfusion measurements showed considerable normal variations among segments. In men, the lowest segmental perfusion measurement was $51.8{\pm}6.5$ and the highest segmental perfusion was $87.0{\pm}5.9$, and they are $58.7{\pm}8.1$ and $87.3{\pm}6.0$, respectively in women. In the viability assessment $Q_{delay}$ showed AUC of 0.633, while those for ${\Delta}_{delay}$ and $Z_{delay}$ were 0.735 and 0.716, respectively. The AUCs of ${\Delta}_{delay}$ and $Z_{delay}$ were significantly higher than that of $Q_{delay}$ (p = 0.001 and 0.018, respectively). The diagnostic performance of ${\Delta}_{delay}$, which showed highest AUC, was 85% of sensitivity and 53% of specificity at the optimal cutoff of -24.7. Conclusion: On automatic quantification of myocardial perfusion SPECT, the normal variation of perfusion measurements were considerable among segments. In the viability assessment, the parameters considering normal variation showed better diagnostic performance than the direct perfusion measurement. This study suggests that consideration of normal variation is important in the analysis of measurements on quantitative myocardial perfusion SPECT.

A Study on the Properties and fabrication to the (Ba,Bi,Sr)TiO3 Ceramics for the Application of High Capacitance (고용량 캐패시터로의 응용을 위한 (Ba,Bi,Sr)TiO3세라믹스의 제조 및 특성에 관한 연구)

  • 이상철;최의선;배선기;이영희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.3
    • /
    • pp.195-201
    • /
    • 2003
  • The (Ba,Bi,Sr)TiO$_3$[BBST] thin films were fabricated on Pt/Ti/SiO$_2$ /Si substrate by RF sputtering method. The effects of Ar/O$_2$ ratio on the structural and dielectric properties of BBST thin films were investigated. Increasing the Ar/O$_2$ ratio, the intensity of BaBi$_4$Ti$_4$O$_{15}$ and Bi$_4$Ti$_3$O$_{12}$ peaks were increased but (Ba$_{0.5}$Sr$_{0.5}$)TiO$_3$ peak was decreased. In the BBST thin films deposited with condition of Ar/O$_2$(90/10) ratio, the composition ratio of the Ba, Bi and Sr atoms were 0.35, 0.25 and 0.4 respectively. The Bi and Ti atoms were diffused into the Pt layers. Increasing the Ar/O$_2$ ratio, the dielectric constant of the BBST thin films were increased but the dielectric loss of the BBST thin films were decreased. The dielectric constant and dielectric loss of the BBST deposited at 90/10 of Ar/O$_2$ ratio were 319 and 2.2%. respectively . Increasing the applied voltage, the capacitance of the BBST thin films were decreased.reased.

Electronic Structure of the SrTiO3(001) Surfaces: Effects of the Oxygen Vacancy and Hydrogen Adsorption

  • Takeyasua, K.;Fukadaa, K.;Oguraa, S.;Matsumotob, M.;Fukutania, K.
    • Applied Science and Convergence Technology
    • /
    • v.23 no.5
    • /
    • pp.201-210
    • /
    • 2014
  • The influence of electron irradiation and hydrogen adsorption on the electronic structure of the $SrTiO_3$ (001) surface was investigated by ultraviolet photoemission spectroscopy (UPS). Upon electron irradiation of the surface, UPS revealed an electronic state within the band gap (in-gap state: IGS) with the surface kept at $1{\times}1$. This is considered to originate from oxygen vacancies at the topmost surface formed by electron-stimulated desorption of oxygen. Electron irradiation also caused a downward shift of the valence band maximum indicating downward band-bending and formation of a conductive layer on the surface. With oxygen dosage on the electron-irradiated surface, on the other hand, the IGS intensity was decreased along with upward band-bending, which points to disappearance of the conductive layer. The results indicate that electron irradiation and oxygen dosage allow us to control the surface electronic structure between semiconducting (nearly-vacancy free: NVF) and metallic (oxygen de cient: OD) regimes by changing the density of the oxygen vacancy. When the NVF surface was exposed to atomic hydrogen, in-gap states were induced along with downward band bending. The hydrogen saturation coverage was evaluated to be $3.1{\pm}0.8{\times}10^{14}cm^{-2}$ with nuclear reaction analysis. From the IGS intensity and H coverage, we argue that H is positively charged as $H^{{\sim}0:3+}$ on the NVF surface. On the OD surface, on the other hand, the IGS intensity due to oxygen vacancies was found to decrease to half the initial value with molecular hydrogen dosage. H is expected to be negatively charged as $H^-$ on the OD surface by occupying the oxygen vacancy site.

Correction of palatally displaced maxillary lateral incisors without brackets

  • Choi, Kyung-Hee;Lee, Yoonjung;Kim, Minji;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.43 no.4
    • /
    • pp.201-206
    • /
    • 2013
  • This article describes the orthodontic treatment of a 25-year-old Korean female patient with anterior crowding, including palatally displaced lateral incisors. Her facial profile was satisfactory, but 3.5 mm of maxillary anterior crowding was observed. To correct this crowding, we decided to minimize the use of the conventional fixed orthodontic appliances and employed a less bulky and more aesthetic appliance for applying light continuous force. We determined the final positions of the maxillary teeth via a working model for diagnostic set up and achieved space gaining and alignment with simple Ni-Ti spring and stainless steel round tubes. Tooth alignment was achieved efficiently and aesthetically without the conventional brackets.

Stress Testing and Imaging Protocols for Myocardial Perfusion Studies (심근관류영상을 위한 심근부하 방법 및 검사 프로토콜)

  • Kim, Seong-Min
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.3
    • /
    • pp.179-195
    • /
    • 2009
  • Scince $^{201}$TI was introduced as a myocardial perfusion imaging agent in the early 1970s, scintigraphic evaluation of myocardial perfusion for the diagnosis of coronary artery disease is a valuable noninvasive diagnostic imaging modality. Stress radionuclide myocardial perfusion imaging is widely accepted to have high diagnostic and prognostic use in the assessment of patients with known or suspected coronary artery disease. With wise use of this nonivasive imaging technique, more patients are referred for stress perfusion imaging. Until now various protocols for stress testing and myocardial imaging were developed and used in worldwide. This article presented various protocols of stress testing and myocardial imaging for clinical use.

Epoxy/BaTiO3 (SrTiO3) composite films and pastes for high dielectric constant and low tolerance embedded capacitors fabrication in organic substrates

  • Paik Kyung-Wook;Hyun Jin-Gul;Lee Sangyong;Jang Kyung-Woon
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2005.09a
    • /
    • pp.201-212
    • /
    • 2005
  • [ $Epoxy/BaTiO_3$ ] composite embedded capacitor films (ECFs) were newly designed fur high dielectric constant and low tolerance (less than ${\pm}15\%$) embedded capacitor fabrication for organic substrates. In terms of material formulation, ECFs are composed of specially formulated epoxy resin and latent curing agent, and in terms of coating process, a comma roll coating method is used for uniform film thickness in large area. Dielectric constant of $BaTiO_3\;&\;SrTiO_3$ composite ECF is measured with MIM capacitor at 100 kHz using LCR meter. Dielectric constant of $BaTiO_3$ ECF is bigger than that of $SrTiO_3$ ECF, and it is due to difference of permittivity of $BaTiO_3\;and\;SrTiO_3$ particles. Dielectric constant of $BaTiO_3\;&\;SrTiO_3$ ECF in high frequency range $(0.5\~10GHz)$ is measured using cavity resonance method. In order to estimate dielectric constant, the reflection coefficient is measured with a network analyzer. Dielectric constant is calculated by observing the frequencies of the resonant cavity modes. About both powders, calculated dielectric constants in this frequency range are about 3/4 of the dielectric constants at 1 MHz. This difference is due to the decrease of the dielectric constant of epoxy matrix. For $BaTiO_3$ ECF, there is the dielectric relaxation at $5\~9GHz$. It is due to changing of polarization mode of $BaTiO_3$ powder. In the case of $SrTiO_3$ ECF, there is no relaxation up to 10GHz. Alternative material for embedded capacitor fabrication is $epoxy/BaTiO_3$ composite embedded capacitor paste (ECP). It uses similar materials formulation like ECF and a screen printing method for film coating. The screen printing method has the advantage of forming capacitor partially in desired part. But the screen printing makes surface irregularity during mask peel-off, Surface flatness is significantly improved by adding some additives and by applying pressure during curing. As a result, dielectric layer with improved thickness uniformity is successfully demonstrated. Using $epoxy/BaTiO_3$ composite ECP, dielectric constant of 63 and specific capacitance of 5.1nF/cm2 were achieved.

  • PDF

Diagnostic Accuracy and Evaluation of Myocardial Viability by Cardiac Magnetic Resonance Imaging in Acute Myocardial Infarction: A Comparison with Thallium-201 Myocardial SPECT (급성심근경색증에서의 심장자기공명영상술의 진단 정확도와 심근 생존력 평가: TI-201 심근관류 SPECT와의 비교)

  • Kim Hye-seon;Park Dong Woo;Kim Yongsoo;Kim Young-sun;Choi Yo Won;Jeon Seok Chul;Seo Heung Suk;Hahm Chang Kok;Kim Soon Kil;Ahn You hern;Choi Yoon Young;Park Choong-Ki
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.100-107
    • /
    • 2003
  • Purpose : To assess the usefulness of cardiac MR imaging (MRI) in the diagnosis of acute myocardial infarction and in the assessment of myocardial viability in comparision with T1-201 SPECT. Materials and Methods : We retrospectively studied 17 patients who complained of chest pain and dyspnea with cardiac MRI . The patients were evaluated for the presence or absence of high signal intensity on T2-weighted image (T2wI), abnormal wall motion on 2D-FIESTA, perfusion defect on Gd-DTPA enhanced T1WI, and delayed myocardial enhancement on 15-minutes delay Gd-DTPA enhanced T1WI. The results were correlated with the images on T1-201 SPECT, taken at rest and stress, through which reversibility of perfusion defect was assessed. Results : Both cardiac MRI and T1-201 SPECT proved to be useful methods for diagnosing acute myocardial infarction. In order of decreasing correspondence, T2WI, T1-201 SPECT, delayed enhancement study, and wall motion images all showed significant statistical correlation with the clinical diagnosis of myocardial infarction. Perfusion MRI, on the other hand, showed no significant statistical difference was found between T1-201 SPECT and cardiac MRI. The results on T2WI showed high accordance with those on Tl-201 SPECT, while delayed myocardial enhancement and wall motion studies showed no agreement with Tl-201 SPECT. Conclusion : Cardiac MRI is useful method for diagnosis of acute myocardiac infarction. With respect to the assessment of myocardial viability, the results obtained on cardiac MRI showed high agreement with those on Tl-201 SPECT. However, further study is necessary at this point for standardization and establishment of the methods for assessing myocardial viability on cardiac MRI.

  • PDF