• Title/Summary/Keyword: THRESHOLD

Search Result 8,542, Processing Time 0.031 seconds

A Pilot Study for Thermal Threshold Test of Trigeminal Nerve Injuries (삼차신경손상의 온도역치검사에 대한 예비연구)

  • Kim, Mee-Eun
    • Journal of Oral Medicine and Pain
    • /
    • v.37 no.4
    • /
    • pp.243-250
    • /
    • 2012
  • Trigeminal nerve injuries due to invasive dental procedures such as implant surgery and extraction is one of the most serious issues in dentistry and may provoke medico-legal problems. Thus, for objective and reliable assessment of nerve injury, a need of QST (quantitative sensory testing) is emphasized and thermal threshold test is an essential part of QST, reported to have acceptable reliability in the orofacial region. This pilot study aimed to evaluate thermal thresholds for limited cases of trigeminal nerve injures. The study investigated 18 clinical cases with trigeminal nerve injuries who visited Department of Oral Medicine, Dankook Univeristy Dental Hospital during the period from May 2011 to Oct 2012. Thermal thresholds was measured by Thermal Sensory Analyzer, TSA-II (Medoc, Israel). Their CDT(cold detection threshold) was significantly decreased in the affected sides compared to the unaffected sides. Other parameters such as WDT(warm detection threshold), CPT(cold pain threshold) and HPT(heat pain threshold) did not show statistical difference between the affected and unaffected sides. Further researches are required to compare thermal thresholds relative to types of nerve deficits such as thermal hyper- or hypoesthesia and hyper- or hypoalgesia for larger sample.

Estimation of Genetic Parameters for Calving Ease by Heifers and Cows Using Multi-trait Threshold Animal Models with Bayesian Approach

  • Lee, D.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.8
    • /
    • pp.1085-1090
    • /
    • 2002
  • Genetic parameters for birth weights (BWT), calving ease scores observed from calves born by heifers (CEH), and calving ease scores observed from calves born by cows (CEC) were estimated using Bayesian methodology with Gibbs sampling in different threshold animal models. Data consisted of 77,458 records for calving ease scores and birth weights in Gelbvieh cattle. Gibbs samplers were used to obtain the parameters of interest for the categorical traits in two univariate threshold animal models, a bivariate threshold animal model, and a three-trait linear-threshold animal model. Samples of heritabilities and genetic correlations were calculated from the posterior means of dispersion parameters. In a univariate threshold animal model with CEH (model 1), the posterior means of heritabilities for calving ease was 0.35 for direct genetic effects and 0.18 for maternal genetic effects. In the other univariate threshold model with CEC (model 2), the posterior means of heritabilities of CEC was 0.28 for direct genetic effects and 0.18 for maternal genetic effects. In a bivariate threshold model with CEH and CEC (model 3), heritability estimates were similar to those in unvariate threshold models. In this model, genetic correlation between heifer calving ease and cow calving ease was 0.89 and 0.87 for direct genetic effect and maternal genetic effects, respectively. In a three-trait animal model, which contained two categorical traits (CEH and CEC) and one continuous trait (BWT) (model 4), heritability estimates of CEH and CEC for direct (maternal) genetic effects were 0.40 (0.23) and 0.23 (0.13), respectively. In this model, genetic correlation estimates between CEH and CEC were 0.89 and 0.66 for direct genetic effects and maternal effects, respectively. These estimates were greater than estimates between BWT and CEH (0.82 and 0.34) or BWT and CEC (0.85 and 0.26). This result indicates that CEH and CEC should be high correlated rather than estimates between calving ease and birth weight. Genetic correlation estimates between direct genetic effects and maternal effects were -0.29, -0.31 and 0.15 for BWT, CEH and CEC, respectively. Correlation for permanent environmental effects between BWT and CEC was -0.83 in model 4. This study can provide genetic evaluation for calving ease with other continuous traits jointly with assuming that calving ease from first calving was a same trait to calving ease from later parities calving. Further researches for reliability of dispersion parameters would be needed even if the more correlated traits would be concerned in the model, the higher reliability could be obtained, especially on threshold model with property that categorical traits have little information.

A Quantitative Analysis of the Cyclomatic Complexity of the Web Software (웹 소프트웨어의 순환복잡도에 대한 정량적 분석)

  • Kim, JeeHyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.2
    • /
    • pp.183-191
    • /
    • 2014
  • In this study Cyclomatic Complexity of Web Software has been analyzed quantitatively by correlation between complexity and Number of Classes(NOC), and Number of Methods(NOM) which are object oriented programming measures. Based on the frequency distribution of complexity, NOC and NOM of software at the Web environment, correlation between complexity threshold and NOC threshold, and NOM threshold has been measured and more than 4,000 ASP files of 10 Web real projects have been used as the sample. The empirical result shows that NOC threshold is 21, NOM threshold is 40 and complexity threshold is 68 as high value, and 8 projects among of 10 except 2 projects with especially high frequency distribution shows that NOC threshold is 12, NOM threshold is 21 and complexity threshold is 52 with relatively low value, so correlation has been found out as exists. And also 8 projects with low threshold of complexity, NOC and NOM were internal management software, and the other 2 projects were external sales service software, Number of Classes and Number of Methods can be defined at the design stage according to business properties, and also the complexity can be estimated in order to improve the software quality.

Calculation of a Threshold for Decision of Similar Features in Different Spatial Data Sets (이종의 공간 데이터 셋에서 매칭 객체 판별을 위한 임계값 산출)

  • Kim, Jiyoung;Huh, Yong;Yu, Kiyun;Kim, Jung Ok
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.1
    • /
    • pp.23-28
    • /
    • 2013
  • The process of a feature matching for two different spatial data sets is similar to the process of classification as a binary class such as matching or non-matching. In this paper, we calculated a threshold by applying an equal error rate (EER) which is widely used in biometrics that classification is a main topic into spatial data sets. In a process of discriminating what's a matching or what's not, a precision and a recall is changed and a trade-off appears between these indexes because the number of matching pairs is changed when a threshold is changed progressively. This trade-off point is EER, that is, threshold. To the result of applying this method into training data, a threshold is estimated at 0.802 of a value of shape similarity. By applying the estimated threshold into test data, F-measure that is a evaluation index of matching method is highly value, 0.940. Therefore we confirmed that an accurate threshold is calculated by EER without person intervention and this is appropriate to matching different spatial data sets.

Influence of Tunneling Current on Threshold voltage Shift by Channel Length for Asymmetric Double Gate MOSFET (비대칭 DGMOSFET에서 터널링 전류가 채널길이에 따른 문턱전압이동에 미치는 영향)

  • Jung, Hakkee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.7
    • /
    • pp.1311-1316
    • /
    • 2016
  • This paper analyzes the influence of tunneling current on threshold voltage shift by channel length of short channel asymmetric double gate(DG) MOSFET. Tunneling current significantly increases by decrease of channel length in the region of 10 nm below, and the secondary effects such as threshold voltage shift occurs. Threshold voltage shift due to tunneling current is not negligible even in case of asymmetric DGMOSFET to develop for reduction of short channel effects. Off current consists of thermionic and tunneling current, and the ratio of tunneling current is increasing with reduction of channel length. The WKB(Wentzel-Kramers-Brillouin) approximation is used to obtain tunneling current, and potential distribution in channel is hermeneutically derived. As a result, threshold voltage shift due to tunneling current is greatly occurred for decreasing of channel length in short channel asymmetric DGMOSFET. Threshold voltage is changing according to bottom gate voltages, but threshold voltage shifts is nearly constant.

Effects of Microcurrent Electrical Neuromuscular Stimulation of Auricular and Somatic Acupuncture Points on Experimental Pressure Threshold (외이경혈 미세전류신경근 자극과 체성경혈 미세전류신경근 자극이 압통역치에 미치는 효과)

  • Ko, Hyun-Chul;Cho, Won-Ho;Han, Seung-Soo
    • Physical Therapy Korea
    • /
    • v.4 no.2
    • /
    • pp.36-50
    • /
    • 1997
  • The purpose of this study was to compare the effects of high intensity, high frequency microcurrent electrical neuromuscular stimulation(MENS) of auricular and somatic acupuncture points and low intensity, low frequency microcurrent electrical neuromuscular stimulation(MENS) of auricular and somatic acupuncture points on experimental pressure threshold at the elbow according to the time. Fifty healthy adults, aged 19 to 26 years, were assigned randomly to one of five groups: 1) the high intensity, high frequency somatic group(n=10) received MENS to somatic acupuncture points, 2) the high intensity, high frequency auricular group(n=10) received MENS to auricular acupuncture points, 3) the low intensity, low frequency somatic group(n=10) received MENS to somatic acupuncture points, 4) the low intensity, low frequency somatic group(n=10) receive MENS to somatic acupuncture points, and 5) the placebo group(n=10) received placebo treatment and served as controls. Pressure threshold was measured before, after, 5 minutes, 10 minutes and 15 minutes. Pressure threshold has increased significantly(p<.05) in the high intensity, high frequency auricular group following treatment after 5 minutes, with no statistically significant differences in pressure threshold change scores among five groups, Only the high intensity, high frequency auricular group demonstrated statistically significant change score in pressure threshold following treatment after, 5 minutes, 10 minutes and 15 minutes after compared to the placebo group. The results indicated that MENS applied to the high intensity, high frequency auricular group increases pressure threshold.

  • PDF

Short-axis cine MR 영상을 이용한 심박출량 측정 : Threshold segmentation 기법의 적용

  • 강원석;최병욱;최규옥;정해조;이상호;유선국;김희중
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.79-79
    • /
    • 2003
  • 심실의 내부는 유두근이나 trabecular와 같은 해부학적 구조물들로 인해 복잡한 형태를 띄고 있다. 그러한 복잡한 구조는 MR 영상을 이용한 심박출량 측정시 오차를 유발시킬 수 있으며, 만약 오차를 줄이기 위해 수작업을 하게 된다면 많은 수고와 시간이 필요하게 될 것이다. 본 연구에서는 threshold 기법을 이용하여 짧은 시간동안에 정확하게 복잡한 구조를 가진 심실의 심박출량을 측정하고자 하였다. 7 명의 환자에 대해 l.5T 급 MR 장치 (INTERA, Philips, Netherlands)를 이용하여 short-axis cardiac MR 영상을 획득하였다. 한 환자에 대해서 8개에서 10개의 슬라이스 영상을 8-10 mm의 두께로, 하나의 심장주기(cardiac cycle)동안 일정한 시간간격으로 25 개의 영상을 획득하였으며, 펄스시퀀스로는 ECG-gated segmented balanced fast field echo (TR/TE = 3ms/1.56ms)를 사용하였다. 획득된 영상은 PC(threshold 기법)와 workstation (기존의 수동 및 자동 segmentation 기법)로 DICOM 형태로 전송되었다. 측정은 IDL을 이용하여 자체 제작된 소프트웨어와 상용화된 소프트웨어 (MASS 5.0, MEDIS, Netherlands)를 이용하여 분석되었다. MR 영상에서 심내벽 부위를 추출하기 위하여 자체제작된 소프트웨어로는 threshold 기법을, 상용 소프트웨어로는 기존의 수동 및 자동 기법을 이용하였다. 심박출량은 최대수축기와 이완기 사이의 용적 차이로써 계산되었으며, 좌심실 및 우심실 모두에 대해 수행되었다. 또한, 해부학적 구조의 복잡도에 따른 측정방법의 정확도를 확인하기 위해 유두근 및 trabecular의 hypertrophy의 정도를 3 단계로 구분하고 측정된 값들을 통계적으로 분석하였다. Hypertrophy가 약한 그룹에서는 기존의 수동방식과 threshold 기법간의 의미있는 차이가 없었으며 (p=0.372), 기존의 수동 및 자동방식 간에도 큰 차이가 없었다 (p=0.298). 그러나, hypertrophy가 심한 그룹에서는 수동방식 및 자동방식 측정치 사이에 통계적으로 유의한 차이를 보임을 알 수 있었다 (p=0.044). 그러나, threshold 기법과 수동방식 사이에는 유의한 차이가 없었다 (p=0.l94). 분석시간은 threshold 기법이 기존의 수동방식에 비해서 두배정도 빠르다는 것을 알 수 있었다, Threshold 기법은 심박출량 측정에 있어서 정확하면서도 빠른 결과의 도출이 가능했으며, 특히 심내벽의 구조가 복잡한 경우에 그 효과가 증대됨을 알 수 있었다.

  • PDF

Change of Pain Threshold and Nociceptive Flexion Reflex of Hyperalgesia Rat by High Voltage Pulsed Current (고전압맥동전류가 통각과민 백서의 통각역치 및 유해성 굴곡반사에 미치는 영향)

  • Kim, Su-Hyon;Moon, Dal-Ju;Choi, Sug-Ju;Jung, Dae-In;Lee, Jung-Woo;Jeong, Jin-Gyu;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.2
    • /
    • pp.25-34
    • /
    • 2006
  • Purpose: This study conducted quantitative sensory test and nociceptive flexion reflex(NFR) measurement to examine degree of pain depending on polarity of high voltage pulsed current(HVPC) of hyperalgesia site in hyperalgesia rat by local thermal injury. mechanical pain threshold, thermal pain threshold and root mean square of NFR were measured. Methods: This study was conducted with control group I of hyperalgesia rat at hind paw by thermal injury and experimental groups divided into cathodal HVPC group II, anodal HVPC group III and alternate HVPC group IV. It measured pain threshold and root mean square(RMS) of NFR and obtained the following results. Results: Mechanical pain threshold of hyperalgeisa site was significantly increased at groups II, III and IV applying HVPC group compared to control group, but there was no difference among HVPC groups. Thermal pain threshold of hyperalgesia site showed a significant increase in group II. Group III showed significant difference after 4 days of hyperalgesia. RMS of NFR at hyperalgeisa site was significantly reduced in group II after 2 days of hyperalgesia. Group III showed significant decrease after 5 and 6 days of hyperalgesia. Conclusion: Consequently it was found that application of HVPC of hyperalgesia site increased pain threshold at hyperalgesia site by mechanical stimuli and thermal stimuli. NFR by electrical stimuli was similar to pain threshold by mechanical stimuli. Effects by polarity of HVPC showed the greatest reduction of hyperalgesia when cathodal electrode was used.

  • PDF

Threshold Voltage Control through Layer Doping of Double Gate MOSFETs

  • Joseph, Saji;George, James T.;Mathew, Vincent
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.10 no.3
    • /
    • pp.240-250
    • /
    • 2010
  • Double Gate MOSFETs (DG MOSFETs) with doping in one or two thin layers of an otherwise intrinsic channel are simulated to obtain the transport characteristics, threshold voltage and leakage current. Two different device structures- one with doping on two layers near the top and bottom oxide layers and another with doping on a single layer at the centre- are simulated and the variation of device parameters with a change in doping concentration and doping layer thickness is studied. It is observed that an n-doped layer in the channel reduces the threshold voltage and increases the drive current, when compared with a device of undoped channel. The reduction in the threshold voltage and increase in the drain current are found to increase with the thickness and the level of doping of the layer. The leakage current is larger than that of an undoped channel, but less than that of a uniformly doped channel. For a channel with p-doped layer, the threshold voltage increases with the level of doping and the thickness of the layer, accompanied with a reduction in drain current. The devices with doped middle layers and doped gate layers show almost identical behavior, apart from the slight difference in the drive current. The doping level and the thickness of the layers can be used as a tool to adjust the threshold voltage of the device indicating the possibility of easy fabrication of ICs having FETs of different threshold voltages, and the rest of the channel, being intrinsic having high mobility, serves to maintain high drive current in comparison with a fully doped channel.

A Study for designing the mobile convergence device : Focusing on Threshold Management of users (모바일 컨버전스 디바이스의 디자인 Guideline: 사용 임계값 관리 (Threshold Management)를 중심으로)

  • Park, Ji-Young
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.769-774
    • /
    • 2009
  • 디지털 기술의 발달과 급진적인 IT 산업의 발전은 환경적 인프라의 통합 및 구축을 촉진시켰으며, 이를 기반으로 한 모바일 기기들의 기술적 통합 (Technology Convergence)을 통하여 테크노매드 (Technomad)와 같은 이동성향을 가진 사용자들이 등장하기 시작하였다. 모바일 컨버전스 디바이스에 대한 사용자들의 니즈 (Needs)는 점차 증가추세를 보이고 있으나, 모바일 컨버전스 디바이스의 수요는 캐즘을 넘지 못하여 시장에서 성공적으로 진입하지 못하고 있는 실정이다. 모바일 컨버전스 디바이스를 통해서 얻을 수 있는 디지털 서비스의 구축이 미비한 부분도 있기는 하지만, 만족스럽지 못한 사용성이나, 기기의 도메인적 특성의 불명확함은 기술이나 성능의 수용 민감도가 높은 선각수용자 (Early Adopter)들의 사용에서만 그치게 하는 등의 한계점을 가지고 있다. 이에 본 연구는 모바일 컨버전스 디바이스의 개념과 도메인적 특성을 조사하고, 이를 통하여 사용 임계값 (Threshold)이 매스유저 (Mass User)가 모바일 컨버전스 디바이스를 사용하는데 진입장벽의 원인으로 작용하는 것을 발견하였다. 이러한 사용 임계값 (Threshold)이 실제 태스크 (Task)수행 시 미치는 영향을 파악하기 위하여 휴리스틱과 선각수용자 (Early Adopter)의 웹 기반 조사를 실시하였고, 사용 임계값 (Threshold)의 영향으로 제대로 사용이 이루어지지 않는 태스크 타입 (Task Type)에 따라 시간적, 물리적 사용 임계값 관리 (Threshold Management)가 필요함을 발견하였다. 이를 개선하기 위해 실제 사용자들의 사용을 FGI (Focused Group Interview) 및 Contextual Inquiry 등의 정성적인 사용자 조사방법을 실시하여, 사용자에게 모바일 컨버전스 디바이스를 통하여 만족스런 사용성 및 경험을 제공하기 위해서는 시간적, 물리적, 시야적 사용 임계값 관리 (Threshold Management)를 개선 해야 함을 밝혀내고 결론적으로 이에 대한 가이드라인을 도출하였다.

  • PDF