• Title/Summary/Keyword: THMs

Search Result 130, Processing Time 0.033 seconds

Demonstration of Low-carbon Pre-oxidation Technology for Algae Using Sodium Permanganate (과망간산나트륨을 활용한 조류 대응 저탄소 전산화기술 실증화 연구)

  • Junsoo, Ha;Daniel Sangdu, Hur;Chaieon, Im;Donghee, Jung;Youngseong, Lim;Jinkyong, Ju
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.6
    • /
    • pp.267-274
    • /
    • 2022
  • This paper is a result of research conducted on the 800,000 m3/d capacity of A Water Treatment Plant (WTP) and 400,000 m3/d capacity of B WTP plant in operation in the Nakdong River region. We evaluated the effect of algae broom on the WTP operation based on the running data of both WTP and the data on the pre-oxidation process field test for algae control using sodium permanganate (SPM) at the B WTP. The study results showed that during the algal bloom period, the coagulant dose increased by 102% in A WTP and 58% in B WTP, respectively, and the chlorine dose also increased by 38% and 29%, respectively, which may affect Total trihalomethane (THM) production. Data such as algal populations and Chl-a, residual chlorine and THM, algal populations, and ozone dose appeared also highly correlated, confirming that algal broom affects WTP operations, including water quality and chemical dosage. As a result of the field test of B WTP, THMs appeared lower than that of the control, suggesting the possibility of the SPM pre-oxidation process as an alternative to algae-related water quality management. Furthermore, in terms of GHG emissions due to energy consumption, it was observed that the pre-oxidation process using SPM was approximately 10.8%, which is a very low ratio compared to the pre-ozonation process. Therefore, these results suggest that the SPM pre-oxidation process can be recommended as an alternative to low-carbon water purification technology.

A Study on Marine Ecological Risk Assessment of Ballast Water Management Technology Using the Sodium Dichloroisocyanurate (NaDCC) Injection Method (이염화이소시아뉼산나트륨(NaDCC) 주입 선박평형수 처리기술의 해양생태위해성평가에 대한 연구)

  • Kim, Tae Won;Moon, Chang Ho;Park, MiOk;Jeon, MiHae;Son, Min Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.2
    • /
    • pp.203-214
    • /
    • 2018
  • Ballast water treated by sodium dichloroisocyanurate (NaDCC) injection method in ballast water management system (BWMS) contains reactive bromine, chlorine species and disinfection by-products (DBPs). In this study, we conducted whole effluent toxicity (WET) testing and ecological risk assessment (ERA) to investigate its ecotoxicological effects on the marine environment. WET testing was carried out for eight marine and fresh water organisms, i.e. diatom, Skeletonema costatum, Navicula pelliculosa, green algae, Dunaliella tertiolecta, Pseudokirchneriella subcapitata, rotifer, Brachionus plicatilis, Brachionus calyciflorus and fish, Cyprinodon variegatus, Pimephales promelas. The WET test revealed that diatom and green algae were the only organisms that showed apparent toxicity to the effluent; it showed no observed effect concentration (NOEC), lowest observable effect concentration (LOEC) and effect concentration of 50 % (EC50) values of 25.0 %, 50.0 % and over 100.0 %, respectively, in seawater conditions. In contrast, rotifer and fish showed no toxicities to the effluent in the all salinity conditions. Meanwhile, chemical analysis revealed that the BWMS effluent contained total of 25 DBPs such as bromate, isocyanuric acid, formaldehyde, chloropicrin, trihalomethanes (THMs), halogenated acetonitriles (HANs) and halogenated acetic acids (HAAs). Based on ERA, the 25 DBPs were not considered to have persistency, bioaccumulation and toxicity (PBT) properties. The ratio of predicted environmental concentration (PEC) to predicted no effect concentration (PNEC) of the all DBPs did not exceed 1.0 for general harbour environments, but isocyanuric acid, tribromomethane, chloropicrin and monochloroacetic acid exceed 1.0 for near ship environments. However, when NOEC (25.0%) of the WET test results where actual effluent was applied, it was concluded that the NaDCC injection method did not have unacceptable ecological risks to the general harbor including near ship environments.

Computing the Dosage and Analysing the Effect of Optimal Rechlorination for Adequate Residual Chlorine in Water Distribution System (배.급수관망의 잔류염소 확보를 위한 적정 재염소 주입량 산정 및 효과분석)

  • Kim, Do-Hwan;Lee, Doo-Jin;Kim, Kyoung-Pil;Bae, Chul-Ho;Joo, Hye-Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.916-927
    • /
    • 2010
  • In general water treatment process, the disinfection process by chlorine is used to prevent water borne disease and microbial regrowth in water distribution system. Because chlorines were reacted with organic matter, carcinogens such as disinfection by-products (DBPs) were produced in drinking water. Therefore, a suitable injection of chlorine is need to decrease DBPs. Rechlorination in water pipelines or reservoirs are recently increased to secure the residual chlorine in the end of water pipelines. EPANET 2.0 developed by the U.S. Environmental Protection Agency (EPA) is used to compute the optimal chlorine injection in water treatment plant and to predict the dosage of rechlorination into water distribution system. The bulk decay constant ($k_{bulk}$) was drawn by bottle test and the wall decay constant ($k_{wall}$) was derived from using systermatic analysis method for water quality modeling in target region. In order to predict water quality based on hydraulic analysis model, residual chlorine concentration was forecasted in water distribution system. The formation of DBPs such as trihalomethanes (THMs) was verified with chlorine dosage in lab-scale test. The bulk decay constant ($k_{bulk}$) was rapidly decreased with increasing temperature in the early time. In the case of 25 degrees celsius, the bulk decay constant ($k_{bulk}$) decreased over half after 25 hours later. In this study, there were able to calculate about optimal rechlorine dosage and select on profitable sites in the network map.

A Study on Relation of Attached Algae and Odor's Cause in Sedimentation Basin of Water Treatment Plant (정수처리공정 중 침전지 부착조류 특성과 이취발생에 관한 연구)

  • Kim, Young-Ung;Son, Hee-Jong;Yu, Myung-Ho;Lee, Chun-Sik;Cho, In-Cheol;Kim, Eun-Ho;Seung, Nak-Chang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.5
    • /
    • pp.887-894
    • /
    • 2000
  • The purposes of this study are investigation of species of attached algae and the relation between attached algae and odor in tap water, Oscillatoria sp. and Mougeotia sp. were colonized at sedimentation basin in water treatment plant. Resulting from analysis, 3.7ppt of geosmin and dimethyl-disulfide with trace were detected in sample of Oscillatoria sp. only, 22 compounds were found in each of sample that had been incubated in room temperature for 5 days, 17 compounds were generated by algal decay. Decayed products were sulfur compounds of 10 species such as dimethyl-sulfide and phenol, p-cresol, indole and scatole. So, it is assumed that attached algae which tolerant to chlorine was the origin of odor in tap water. They usually formed big colonies. Colonies on the bottom were decayed because of anaerobic state. While decaying they were detached from colonies and so, odorous compounds are originated from this decayed algae.

  • PDF

Studies on the anodic oxidation of some volatile organic halogen compounds(THM) (휘발성 할로겐 화합물(THM)의 양극 산화에 관한 연구)

  • Yoo, K.S.;Park, S.Y.;Yang, S.B.;Woo, S.B.
    • Analytical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.264-273
    • /
    • 1997
  • Anodic oxidation reaction was applied to remove trihalomethanes in an aqueous solution. Each component was determined by using solid phase microextraction(SPME) fiber and GC-ECD. Anodic and cathodic compartments were separated in order to protect contaminants and connected by $KNO_3$-agar bridge. The calibration graphs of the 6 THM components were shown good linearlity from a few ppb up to a few hundreds ppb concentration level. Anodes such as platinum(Pt), titanium(Ti). zircornium(Zr), titanium metal coated with iridium(Ti-Ir), and glassy carbon coated with mixed valence ruthenium(mv Ru) were tried to remove the THMs at different potentials. The best result was obtained on the Ti-Ir anode applied 9 volts DC. The electrode could effectively remove almost all the THM components from the stirring solution within about 1.5 hours. The glassy carbon electrode coated with mixed valence ruthenium showed excellent removing effect at the begining, but the maximum removing level was remained at 60% probably due to the destruction of the electrode surface. The concentration of chloroform, however, tends to be increased due to the electrode reaction producing the component at the condition.

  • PDF

Constructing the Operating Information System(OIS) and Improving the Water Quality by OIS in Water Treatment Plants (수도시설 운영정보화 시스템 구축 및 효율개선효과)

  • Oh, Jung-Woo;Song, Yoon-Seob;Kang, Geum-Bai;Yoo, Man-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.6
    • /
    • pp.699-705
    • /
    • 2007
  • In this study, the improvement of the operation condition and the water quality in water treatment plant by operating information system(OIS) was evaluated for Ansan water treatment plant. The average flow rate of raw water in the year 2005(after constructing the OIS) appeared 15.6 % lower than that in the year 2004(before constructing the OIS). The mean value(12.37 NTU) of raw water turbidity in the year 2005 remained constant, or nearly so with that(12.06 NTU) in the year 2004. The average dosing rates of coagulant appeared 12.06 mg/L in the year 2005 which was higher than 10.31 mg/L in the year 2004. Furthermore, the average turbidity concentration of fresh water in the year 2005 appcared slightly better than that in the year 2004. From $COD_{Mn}$ and BOD concentration of raw water, the water quality in the year 2005 were better than those in the year 2004. The average concentration of $KMnO_4$ in the year 2004 and the year 2005 was 2.95 mg/L and 1.25 mg/L, respectively, and the average concentration of THMs in the year 2004 and the year 2005 appeared 0.038 mg/L and 0.025 mg/L, respectively. Therefore, the fresh water quality in the year 2005 was better than that in the year 2004. In this study, it is considered that the operation of Ansan water treatment plant may be optimized by OIS, and thus the OIS may be very useful method to improve the water quality.

Health Risk Assessment of Disinfection By-products by Chlorination in Tap Water Ingestion (수도수중 염소 소독부산물로 인한 건강위해성 평가에 관한 연구 - 서울시 수도수중 Trihalomethanes 및 Haloaceticnitriles을 중심으로 -)

  • Chung, Yong;Shin, Dong-Chun;Yang, Ji-Yeon;Park, Yeon-Shin;Kim, Jun-Sung
    • Environmental Analysis Health and Toxicology
    • /
    • v.12 no.3_4
    • /
    • pp.31-41
    • /
    • 1997
  • Public concerns about hazardous health effect from the exposure to organic by-products of the chlorination have been increased. There are numerous studies reporting that chlorination of drinking water produces numerous chlorinated organic by-products including THMs, HAAs, HANs. Some of these products are known to be animal carcinogens. The purpose of this study was to estimate health risk of DBPs by chlorinated drinking water ingestion in Seoul based on methodologies that have been developed for conducting risk assessment of complex-chemical-mixture. The drinking water sample was collected seperately at six water treatment plant in Seoul at March, April, 1996. In tap water of households in Seoul, DBPs were measured wilfh the mean value of 36.6 $\mu$g/L. Risk assessment processes,. which include processes for the estimation of human cancer potency using animal bioassay data and calculation of human exposure, entail uncertainties. In the exposure assessment process, exposure scenarios with various assumptions could affect the exposure amount and excess cancer risk. The reference dose of haloacetonitriles was estimated to be 0.0023 mg/kg/day by applying dibromoacetonitrile NOAEL and uncertainty factor to the mean concentration. In the first case, human excess cancer risk was estimated by the US EPA method used to set the MCL (maximum contaminant level). In the second and third case, the risk was estimated for multi-route exposure with and without adopting Monte-Carlo simulation, respectively. In the second case, exposure input parameters and cancer potencies used probability distributions, and in the third case, those values used point estimates (mean, and maximum or 95% upper-bound value). As a result, while the excess cancer risk estimated by US EPA method considering only direct ingestion tended to be underestimated, the risk which was estimated by considering multi-route exposure without Monte-Carlo simulation and then using the maximum or 95% upper-bound value as input parameters tended to be overestimated. In risk assessment for Trihalomethanes, considering multi-route exposure with adopting Monte-Carlo analysis seems to provide the most reasonable estimations.

  • PDF

Operation of Advanced Water Treatment Processes for Downstream River Source Water (상수원수의 고도정수처리 공정 파일롯 운전 연구)

  • Wang, Chang-Keun;Oh, Sang-Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • Down Stream K River has high COD (4-10 mg/L) and high $NH_3$-N concentration (3.5 mg/L during winter period). Although $NH_3$-N itself is not reported harmful at this level, it must be removed to meet drinking water standard (0.5 mg/L). We constructed a pilot plant modifying the processes of conventional drinking water facilities. Prechlorination and powdered activated carbon (PAC) dechlorination was adopted prior to a flocculation tank to remove ammonia and prevent disinfection byproducts (DBPs) formation. Also, GAC processes was included after sand filter to remove residual DOC. This pilot having a capacity of 36 ton/day was operated for one year. The GAC processes were successful to remove ammonia and many organic pollutants (DOC, MBAS, UV-254 nm absorbance, etc). Influent DOC concentrations were very high as 3~6 mg/L throughout the plant operation. It was impossible to achieve 1.0 mg/L effluent DOC, indicating that bed depth (2 m) should be increased to achieve more strict DOC quality standards. When $Cl_2$ dose was well controlled ($Cl_2/NH_3$-N ratio 10~11 on a weight basis), $NH_3$-N removal was 98% and THMs was very low possibly due to low free residual chlorine and PAC dechlorination.

Effect of Pore Structure Change on the Adsorption of NOM and THMs in Water Due to the Increase of Reactivation Number of Coal-based Activated Carbon (석탄계 활성탄의 재생 횟수 증가에 따른 세공 구조 변화가 수중의 NOM과 THM 흡착에 미치는 영향)

  • Son, Hee-Jong;Ryu, Dong-Choon;Jang, Seong-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.965-972
    • /
    • 2010
  • The objective of this research was to evaluate for the changes of pore structures and adsorption capacities due to the increase the numbers of reactivation. The reactivated GAC had experienced three cycles of water treatment and thermal reactivation. The pore size distributions of virgin and reactivated GACs were very different. The virgin GAC was mostly microporous (< $15\;{\AA}$), with less mesopores ($20{\sim}100\;{\AA}$). The reactivated GACs was mostly mesoporous ($20{\sim}100\;{\AA}$), with less micropores (< $15\;{\AA}$). The specific surface area and total pore volume were reduced as the number of reactivation increased. The maximum adsorption capacity (X/M) of virgin GAC ($964.6\;{\mu}g/g$) for $CHCl_3$ was 2~3 times larger than 1st~3rd reactivated GAC ($255.6{\sim}399.5\;{\mu}g/g$). The maximum adsorption capacity (X/M) of virgin GAC (19.5 mg/g) for DOC (dissolved organic carbon) was equal to that of 1st~3rd reactivated GAC (18.0~18.7 mg/g).

Characteristics of Chlorination Byproduct Formation of Synthetic Nitrogenous Compounds (합성유기질소 성분에서의 염소 소독부산물 생성 특성)

  • Son, Hee-Jong;Hwang, Young-Do;Roh, Jae-Soon;Bean, Jae-Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.523-530
    • /
    • 2010
  • This study was conducted to analyze and determine formation potentials for chlorination disinfection by-products (DBPs) from 14 synthetic nitrogen compounds with or without $Br^-$. 5 of 14 compounds were 3-aminobenzoic acid, 2-aminophenol, aniline, anthranilic acid and 4-nitroaniline that were relatively shown high for formation of THMs/DOC whether or not $Br^-$ presented. 6 compounds that were p-nitrophenol, 3-aminobenzoic acid, 2-aminophenol, aniline, anthranilic acid and 4-nitroaniline were shown high for formation of haloacetic acids (HAAs)/DOC whether or not $Br^-$ presented. Trichloroacetic acid (TCAA) was dominated in 6 compounds. The formation of haloacetonitriles (HANs)/DOC whether or not $Br^-$ presented was high in 3-aminobenzoic acid, 2-aminophenol, aniline and anthranilic acid. Specially, aniline was detected 14.6∼16.1 ${\mu}g/mg$. The formation of chloral hydrate (CH)/DOC and chloropicrin (CP)/DOC were shown high in 3-aminobenzoic acid and 2-aminophenol in 14 compounds. 6 compounds (3-aminobenzoic acid, 2-aminophenol, aniline, anthranilic acid, 4-nitroaniline, p-nitrophenol) and a commercial humic acid were tested for the formation of DBPs/DOC whether or not $Br^-$ presented. When $Br^-$ was added, the DBPs/DOC was higher for the order of aniline> anthranilic acid> 3-aminobenzoic acid> 4-nitroaniline> humic acid> p-nitrophenol> 2-aminophenol. And when $Br^-$ was not added, the DBPs/DOC was higher for the order of anthranilic acid> aniline> p-nitrophenol> humic acid> 4-nitroaniline> 3-aminobenzoic acid> 2-aminophenol.