• 제목/요약/키워드: TEST-RETEST RELIABILITY

검색결과 409건 처리시간 0.03초

The test-retest reliability of gait kinematic data measured using a portable gait analysis system in healthy adults

  • An, Jung-Ae;Byun, Kyung-Seok;Lee, Byounghee
    • 대한물리치료과학회지
    • /
    • 제27권3호
    • /
    • pp.25-34
    • /
    • 2020
  • Background: Gait analysis is an important measurement for health professionals to assess gait patterns related to functional limitations due to neurological or orthopedic conditions. The purpose of this study was to investigate the reliability of the newly developed portable gait analysis system (PGAS). Design: Cross-sectional design. Test-retest study. Methods: The PGAS study was based on a wearable sensor, and measurement of gait kinematic parameters, such as gait velocity, cadence, step length and stride length, and joint angle (hip, knee, and ankle) in stance and swing phases. The results were compared with a motion capture system (MCS). Twenty healthy individuals were applied to the MCS and PGAS simultaneously during gait performance. Results: The test-retest reliability of the PGAS showed good repeatability in gait parameters with mean intra-class correlation coefficients (ICCs) ranging from 0.840 to 0.992, and joint angles in stance and swing phase from 0.907 to 0.988. The acceptable test-retest ICC was observed for the gait parameters (0.809 to 0.961), and joint angles (0.800 to 0.977). Conclusion: The results of this study indicated that the developed PGAS showed good grades of repeatability for gait kinematic data along with acceptable ICCs compared with the results from the MCS. The gait kinematic parameters in healthy subjects can be used as standard values for adopting this PGAS.

The Reliability and Validity of Korean Pediatric Functional Muscle Testing in Children with Motor Disorder

  • Seo, Hye-Jung;Kim, Joong-Hwi
    • The Journal of Korean Physical Therapy
    • /
    • 제28권4호
    • /
    • pp.232-242
    • /
    • 2016
  • Purpose: This study was conducted to develop a Korean version of the pediatric functional muscle test (K-PFMT) for children with motor developmental disorders, and to verify its reliability and validity. Methods: The subjects were 40 children, aged below 5 years. Each was scored on the K-PFMT by 14 physical therapists to determine inter-rater reliability and internal consistency. Additionally, 3 of the 14 therapists tested 20 children again one or two weeks later to determine test-retest reliability. The internal consistency was calculated by Cronbach's alpha. The inter-rater and test-retest reliability were calculated using the intraclass correlation coefficient (ICC). One-way ANOVA and the paired t-test were used to compare differences among the three evaluator groups and between the test and retest group. Concurrent validity was evaluated by Pearson's correlation with a total score of GMFM. Results: Chronbach's alpha was over 0.98 for each test item and 0.99 for the total items. There was no significant differences in the score of K-PFMT among the three evaluator groups except for a few items. The test-retest ICC was from 0.89 to 1.00 and from 0.82 to 1.00, respectively. There was no significant difference between the test and retest group, except for a few items. There were high significant correlations between K-PFMT and GMFM. Conclusion: This study showed that a K-PFMT with relatively high reliability and validity was successfully developed. The K-PFMT will be a useful tool for measurement of muscle strength of children with motor developmental disorder.

Validity and Reliability of Ultrasound Measurement of Knee Joint Space Width in Individuals With Knee Osteoarthritis

  • Kim, Geon;Cha, Young-joo;Shin, Ji-won;You, Sung-hyun
    • 한국전문물리치료학회지
    • /
    • 제26권1호
    • /
    • pp.60-66
    • /
    • 2019
  • Background: Knee osteoarthritis (OA) is a single most arthritic disease. Knee joint space width (JSW) is commonly used for grading severity of knee OA. However, previous studies did not established criterion validity and test-retest reliability of ultrasound (US) image for measuring JSW. Objects: The aim of this study was to establish criterion validity and test-retest reliability of US measurement of medial and lateral knee JSW. Methods: Twenty-nine subjects with knee OA were participated. The US and X-ray were used to measure knee JSW. One sample Kolmogorov-Smirnov test was used to confirm the data normal distribution. Pearson correlation coefficient and ICC were used to calculated and establish criterion validity and test-retest reliability, respectively. Results: US measurement of medial and lateral knee JSW was highly correlated with radiographic imaging measure (r=.714 and .704, respectively). Test-retest reliabilities of medial and lateral knee JSW were excellent correlated (ICC=.959 for medial side and .988 for lateral side, respectively). Conclusion: US may be valid tool to measure knee JSW.

A study on the clinical usefulness, validity, and test-retest reliability of the Spirokit, a device that combines the pulmonary function test and respiratory muscle strength test

  • Kim, Byeong-Soo;Lee, Myung-Mo
    • Physical Therapy Rehabilitation Science
    • /
    • 제9권2호
    • /
    • pp.120-130
    • /
    • 2020
  • Objective: This study was conducted to identify the clinical usefulness, validity, and reliability of the Spirokit, a device that combines the pulmonary function test (PFT) and respiratory muscle strength (RMS) test. Design: Cross-sectional study. Methods: Forty young adults (male: 23, female: 17) participated in a PFT and a RMS test. The concurrent validity for pulmonary function was assessed by comparing data obtained from MicroQuark and the Spirokit and the agreements between the MicroRPM and the Spirokit for RMS were compared. The test-retest reliability of the Spirokit was determined by comparing data obtained from the first and second sessions. The test and retest were performed at the same time after one day for the PFT and RMS test. Validity was estimated using intraclass correlation coefficients (ICCs), and by calculating 95% limits of agreement (LoA). To estimate interrater reliability, ICCs were calculated. Results: The Spirokit showed a high agreement intra class coefficient (ICC [2, 1]): 0.978-0.999, 95% limits of agreements (95% LOA): -0.798 to 0.847 with MicroQuark. It also showed a high level of concordance ICC (2, 1): 0.992 to 0.993, 95% LOA: -9.313 to 11.169 with MicroRPM. The test-retest reliability of the Spirokit was analyzed using ICC (2, 1), and showed a high level of reliability (ICC [2,1]=0.960 to 0.998). Standard error of measurement % (SEM%) was 0.12% to 3.39%, and minimum detectable change% (MDC%) was 0.02% to 3.79%, indicating high level of reliability. Conclusions: The Spirokit is a device with high validity and reliability that can be used to simultaneously measure PFT and RMS tests.

The Reliability of the Pediatric Functional Muscle Testing in Children with Developmental Delay

  • Seo, Hye-Jung;Kim, Joong-Hwi
    • The Journal of Korean Physical Therapy
    • /
    • 제27권4호
    • /
    • pp.183-189
    • /
    • 2015
  • Purpose: The aim of this study was to examine the test-retest and inter-rater reliability of the pediatric functional muscle testing (PFMT) when applied to children with developmental delay. Methods: Sixteen children with developmental delay (seven females, nine males) participated in this study. For the inter-rater reliability, each was scored on the PMFT by two pediatric physical therapists with more than 8 years of clinical experience on the same day. For assessment of the test-retest reliability, one therapist tested the children again within 10 days. The second measurement was performed by taking a first measurement in video. Intraclass correlation coefficient (ICC) was calculated to determine the test-retest and inter-rater reliability of the PFMT, and Chronbach's alpha was used to measure internal consistency. Results: The results of this study were as follows: 1) The test-retest ICC of the score of the infant action month and the right side of the PFMT was from 0.53 to 1.00 and from 0.63 to 0.99, respectively. 2) The inter-rater ICC of the score of the infant action month and the right side of the PFMT was from 0.66 to 1.00 and from 0.64 to 1.00, respectively. 3) Chronbach's alpha was 0.93. The internal consistency indicated excellent. Conclusion: In conclusion, this study showed that the test-retest and inter-rater reliability of the PFMT was relatively high, except for a few items. Therefore, it can be suggested that the PFMT will be a useful tool for measurement of muscle strength for children with developmental delay if it be some modifications.

사상체질분류검사지에서 검사-재검사법을 통한 설문 문항에 대한 연구 (A Study on Questionnaires through the Test-Retest Method of Questionnaire for the Sasang Constitution Classification II)

  • 신미란;고호연;이재혁
    • 사상체질의학회지
    • /
    • 제35권1호
    • /
    • pp.35-45
    • /
    • 2023
  • Objectives We tried to examine the change in the test-retest response for the questionnaire itself regarding the QSCCII. Methods Tests were conducted twice times with an interval of 6 months between tests for test-retest reliability analysis. We examined the test-retest answer agreement rate (%) in all items of QSCCII . We conducted NcNemar analysis to examine test-retest reliability for 77 items selected from the QSCCII. Results The body shape-multiple-choice items showed a tendency of low test-retest agreement rate and most of the questions about when I was not well and when I felt my body condition improve showed an high test-retest agreement rate tendency in all items of QSCCII. As a result of the research on the selected 77 items, there was a significant change in the answer in item No.25, 58(in the item of Soeumin) item No.45, 103(in the item of Taeumin) and item No.87 (in the item of Soeumin) (Table.3, 4, 5, 6). Conclusion The QSCCII is shown as a questionnaire composed of mostly no significant response changes in test-retest in each item through this study. Some items were appropriately deleted in the process of developing the advanced model, but there are also items that should be considered further. It is thought that some items should be used after being refined in content and form.

승용 자동차 조종장치 스테레오타입 조사를 위한 설문조사법의 신뢰성 (Test-Retest Reliability of Paper-Pencil Test for Investigating Stereotypes of Controls of Passenger Cars)

  • 기도형
    • 대한안전경영과학회지
    • /
    • 제17권2호
    • /
    • pp.201-206
    • /
    • 2015
  • This study aims to investigate test-retest reliability or reproducibility of the paper-pencil test for investigating stereotypes of seven principal controls of passenger cars. The controls include wiper, head light, high beam, door window, ignition key, door key and door lock. Sixty two college-aged students participated in the paper-pencil tests and the tests were conducted twice with an in-between period of 4 weeks. The results showed that the stereotypes of motion-directions for the seven controls by the two paper-pencil tests were the same, and that the percentage agreements between two tests by subjects were ranged from 60.0% to 80.6%. There was a weak linear relationship between averaged rates of responses for the stereotypes of motion-directions for the seven controls and percentage agreements by subjects. Based on these results, it is concluded that the paper-pencil test collects reliable or reproducible data on the stereotypes of motion-directions for passenger cars' controls within four weeks.

Comparisons of Test-Retest Reliability of Strength Measurement of Gluteus Medius Strength between Break and Make Test in Subjects with Pelvic Drop

  • Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • 제31권3호
    • /
    • pp.147-150
    • /
    • 2019
  • Purpose: The purpose of this study was to compare the reliability of unilateral hip abductor strength assessment in side-lying with break and make test in subjects with pelvic drop. Hip abduction muscles are very important in the hip joint structures. Therefore, it is essential to evaluate their strength in a reliable way. Methods: Twenty-five subjects participated in this study. Unilateral isometric hip abductor muscle strength was measured in side-lying, with use of a specialized tensiometer using smart KEMA system for make test, of a hand held dynamometer for break test. Coefficients of variation, and intra class correlation coefficients were calculated to determine test-retest reliability of hip abductor strength. Results: In make test, maximal hip abductor strength in the side-lying position was significantly higher compared with break test (p<0.05). Additionally, Test-retest reliability of hip abductor strength measurements in terms of coefficients of variation (3.7% for make test, 16.1% for break test) was better in the side-lying position with make test. All intraclass correlation coefficients with break test were lower than make test (0.90 for make test, 0.73 for break test). Conclusion: The side-lying body position with make test offers more reliable assessment of unilateral hip abductor strength than the same position with break test. Make test in side-lying can be recommended for reliable measurement of hip abductor strength in subjects with pelvic drop.

The Test-Retest Reliability of Subjective Visual Horizontal Testing: Comparisons between Solid and Dotted Line Images

  • Zakaria, Mohd Normani;Wahat, Nor Haniza Abdul;Zainun, Zuraida;Sakeri, Nurul Syarida Mohd;Salim, Rosdan
    • Journal of Audiology & Otology
    • /
    • 제24권2호
    • /
    • pp.107-111
    • /
    • 2020
  • The present study aimed to determine the test-retest reliability of subjective visual horizontal (SVH) testing when tested with solid and dotted line images. In this repeated measures study, 36 healthy young Malaysian adults (mean age=23.3±2.3 years, 17 males and 19 females) were enrolled. All of them were healthy and had no hearing, vestibular, balance, or vision problems. The SVH angles were recorded from each participant in an upright body position using a computerized device. They were asked to report their horizontality perception for solid and dotted line images (in the presence of a static black background). After 1 week, the SVH procedure was repeated. The test-retest reliability of SVH was found to be good for both solid line [intraclass correlation (ICC)=0.80] and dotted line (ICC=0.78). As revealed by Bland-Altman plots, for each visual image, the agreements of SVH between the two sessions were within the clinically accepted criteria (±2°). The SVH testing was found to be temporally reliable, which can be clinically beneficial. Both solid and dotted lines in the SVH testing are reliable to be used among young adults.

The Test-Retest Reliability of Subjective Visual Horizontal Testing: Comparisons between Solid and Dotted Line Images

  • Zakaria, Mohd Normani;Wahat, Nor Haniza Abdul;Zainun, Zuraida;Sakeri, Nurul Syarida Mohd;Salim, Rosdan
    • 대한청각학회지
    • /
    • 제24권2호
    • /
    • pp.107-111
    • /
    • 2020
  • The present study aimed to determine the test-retest reliability of subjective visual horizontal (SVH) testing when tested with solid and dotted line images. In this repeated measures study, 36 healthy young Malaysian adults (mean age=23.3±2.3 years, 17 males and 19 females) were enrolled. All of them were healthy and had no hearing, vestibular, balance, or vision problems. The SVH angles were recorded from each participant in an upright body position using a computerized device. They were asked to report their horizontality perception for solid and dotted line images (in the presence of a static black background). After 1 week, the SVH procedure was repeated. The test-retest reliability of SVH was found to be good for both solid line [intraclass correlation (ICC)=0.80] and dotted line (ICC=0.78). As revealed by Bland-Altman plots, for each visual image, the agreements of SVH between the two sessions were within the clinically accepted criteria (±2°). The SVH testing was found to be temporally reliable, which can be clinically beneficial. Both solid and dotted lines in the SVH testing are reliable to be used among young adults.