• 제목/요약/키워드: TEST-1

검색결과 60,001건 처리시간 0.066초

A Study on the Built-In Self-Test for AC Parameter Testing of SDRAM using Image Graphic Controller

  • Park, Sang-Bong;Park, Nho-Kyung;Kim, Sang-Hun
    • The Journal of the Acoustical Society of Korea
    • /
    • 제20권1E호
    • /
    • pp.14-19
    • /
    • 2001
  • We have proposed BIST method and circuit for embedded 16M SDRAM with logic. It can test the AC parameter of embedded 16M SDRAM using the BIST circuit capable of detecting the address of a fail cell installed in an Merged Memory with Logic(MML). It generates the information of repair for redundancy circuit. The function and AC parameter of the embedded memory can also be tested using the proposed BIST method. It is possible to test the embedded SDRAM without external test pin. The total gate of the BIST circuit is approximately 4,500 in the case of synthesizing by 0.25μm cell library and is verified by Verilog simulation. The test time of each one AC parameter is about 200ms using 2Y-March 14n algorithm.

  • PDF

골관절증이 유발된 토끼에서 Sodium Hyaluronate의 효과 (Effect of Sodium Hyaluronate on Osteoarthrosis in Rabbit Model)

  • 이진원;김창환;박종환;최은실;홍정주;박재섭;박재학
    • Biomolecules & Therapeutics
    • /
    • 제7권4호
    • /
    • pp.347-353
    • /
    • 1999
  • Osteoarthrosis was induced in rabbit knees through resecton of anterior cruciate ligament. Sodium hyaluronate (1%) was administerated into articular space at the dose levels of 0.1 mg/kg once a week using 1ml sylinge and 26G needle for test groups. Saline was administrated for control groups. After 6 and 12 weeks, animals were sacrificed to conduct macroscopic observation and histopathologic examination. The articular lesions were evaluated and test groups were compared with control groups. No significant differencies were showed between test groups and control groups at macroscopic observation in both 6- and 12- week groups. In histopathologic examination, control groups showed higher osteoarthrosis than test groups. The articular surfaces of control groups showed fibrillation, denudation, pannus formation and hypocellularity. The articular surfaces of test groups showed fibrillaton and hypercellularity. These indicate that sodium hyaluronate has inhibitory effects on osteoarthrosis at least in rabbit and could be used for treatment of osteoarthrosis.

  • PDF

아동의 인지양식과 대인 문제 해결력 - 5세, 7세, 및 9세 아동을 대상으로 - (Cognitive Style and Interpersonal Problem Solving Ability among 5-, 7-, and 9-year-olds)

  • 정윤주;이순형
    • 아동학회지
    • /
    • 제14권1호
    • /
    • pp.77-89
    • /
    • 1993
  • The purpose of this study was to investigate (1) children's field dependence by age and sex, (2) children's interpersonal problem solving ability by age, sex, and contextual factors, (3) children's interpersonal problem solving ability by field dependence. The subjects were 120 five-, seven-, and nine-year-olds. Children's field-dependence was measured with the Children's Embedded Figures Test (CEFT). Children's interpersonal problem solving ability was measured with the Preschool Interpersonal Problem Solving Test (PIPS Test). Statistical methods adopted for data analysis were frequencies, percentiles, means, standard deviation, t-test, oneway ANOVA. $Scheff{\acute{e}}$ test and Pearson's correlations. Major findings were that (1) The older children were more field-independent than the younger ones (2) The older children suggested more problem solving methods and higher-level problem solving strategies than the younger ones. (3) Children suggested higher-level problem solving strategies in contexts involving familiar as opposed to unfamiliar participants and contexts involving children as opposed to adults. (4) 9-year-olds' field-independence was positively associated with interpersonal problem solving ability.

  • PDF

현장.실내 시험에 의한 연직 및 수평 압밀계수의 상관관계 분석 (Correlation of Vertical and Horizontal Coefficient of Consolidation by Laboratory test and Field Test)

  • 구남실;이재식;윤일형;노영목
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.117-122
    • /
    • 1999
  • Laboratory and field investigations of the coefficient of vertical and horizontal consolidation for Yangsan clay deposit were carried out using the conventional oedometer, Rowecell and piezocone test. Correlation among these test methods were also studied. In this paper, the relationship between vertical and horizontal consolidation were suggested such as C$\sub$h(Oed)/=0.75∼1.46 C$\sub$v(Oed)/, C$\sub$h(Rowecell) =1.95∼2.93 C$\sub$v(Oed)/, C$\sub$h(piezocone)/ =1.0∼5.0 C$\sub$v(Oed)/. As a result, a fair approximate estimations of C$\sub$h/ can be made by simple test using the conventional oedometer tests.

  • PDF

회전부를 장착한 터빈 시험장비 개발 (Development of a Rotating Turbine Test Rig)

  • 박응식;송성진;홍용식
    • 한국유체기계학회 논문집
    • /
    • 제1권1호
    • /
    • pp.58-63
    • /
    • 1998
  • To investigate turbine flow fields under realistic conditions, a rotating turbine test facility has been developed at the Inha University Propulsion Laboratory. The experimental facility consists of an air inlet, settling chamber, single turbine stage test section, and diffuser. This turbine has a design flow coefficient of 0.55 and work coefficient of 1.88. The turbine test rig has four features. First, a large scale test section improves space resolution. Second, low speed rpm enhances safety and reduces required power, Third, DC motor/generator is able to regenerate blower power. Fourth, various types of experiment can be carried out.

  • PDF

Rock Permeability Estimation from Hydraulic Injection Tests in a Sealed Borehole Interval

  • Quach, Nghiep Q.;Jo, Yeonguk;Chang, Chandong
    • 지질공학
    • /
    • 제28권1호
    • /
    • pp.1-9
    • /
    • 2018
  • We propose a borehole test technique to estimate permeability of rocks in borehole. The borehole tests are hydraulic injection tests such as leak-off test and hydraulic fracturing tests, which are originally conducted for stress or casing integrity assessment and not for permeability measurement. We use one-dimensional radial diffusion equation to interpret fluid injection test results in terms of permeability. We apply this technique to a leak-off test conducted at a depth of 700 m in a wellbore, where rock formation is mudstone. The estimated permeability is at an order of $10^{-16}m^2$, which is somewhat high but within the range reported for mudstones previously. Quantitative rick assessment suggests that an accurate measurement of open hole section length is important to improve reliability of results. More data may be needed to ensure the reliability of this technique. If validated, however, this technique can provide cost-effective estimation of in situ permeability without conducting independent permeability tests in borehole.

Safety Requirements and Test Methods of a Radiofrequency Stimulator

  • Park, Sang-Geon
    • Journal of information and communication convergence engineering
    • /
    • 제14권3호
    • /
    • pp.191-199
    • /
    • 2016
  • In this study, we investigate the safety requirements and test methods of a radiofrequency stimulator. The main test items include controls of a minimum output, accommodation range, and output parameters that have been known as the safety requirements in conformity with international standards. As the test criteria for controlling the minimum output, an increase or decrease in a unit of 1 mA or 1 V or less was applied to the output amplitude regulator for both continuous and discontinuous control, and the output at the minimum setting was manipulated to not exceed 2% of the maximum setting. For controlling the output parameters, one of the representative test criteria states that the current limit of 250 mA should be equal to or less than 1,500 Hz. Consequently, when applying the radiofrequency stimulator on the human body, we need to ensure that the safety requirements conform to the international standards.

격벽화된 파이프 트러스 요소로 구성된 경량방음터널의 구조적 성능 평가 (Assessment of Structural Performance for a Lightweight Soundproof Tunnel Composed of Partitioned Pipe Truss Members)

  • 노명현;안동욱;주형중
    • 복합신소재구조학회 논문집
    • /
    • 제7권1호
    • /
    • pp.1-8
    • /
    • 2016
  • In this paper, the full-size structural performance test for a lightweight soundproof tunnel composed of partitioned pipe truss members is carried out to investigate the structural performance. In addition, a nonlinear structural analysis of the same finite element model as the full-size testing model is performed to compare the test result. The test and analysis results showed that the lightweight soundproof tunnel ensures the structural safety against wind loads, snow loads and load combinations. As a result, the full-size test and analysis results meet all the design load conditions, hence the proposed lightweight soundproof tunnel is ready for the field application.

무베어링 허브 훨타워 시험을 위한 무힌지 블레이드 보강 (Hingeless Blade Reinforcement for Whirl Tower Test of Bearingless Hub)

  • 김태주;윤철용;기영중;김승호;정성남
    • 항공우주시스템공학회지
    • /
    • 제6권1호
    • /
    • pp.1-6
    • /
    • 2012
  • During helicopter rotor system development process, whirl tower test is conducted basically. For conducting whirl tower test during bearingless hub development process, design new blade or using existing blade with repair or remodeling. Because simple shape and efficient aerodynamic characteristic, BO-105 blade is used for hub system development widely. Originally BO-105 Blade is used for hingeless hub, so flap stiffness and lag stiffness on blade root area is relatively low. So appling BO-105 blade to bearingless hub whirl tower test, root area have to be reinforce. In this paper, suggest reinforcement method of BO-105 blade root area.

마우스 말초혈액 망상적혈구를 이용한 Mitomycin C의 소핵생성효과 (The micronucleus formation in peripheral blood of mitomycin C-treated mice using supravital staining with acridine orange)

  • 허문영;류재천
    • 한국환경성돌연변이발암원학회지
    • /
    • 제16권1호
    • /
    • pp.24-29
    • /
    • 1996
  • In this study, the micronucleus test with peripheral blood using acridine orange coated slides was evaluated in mice treated with mitomycin C(MMC) at doses of 0.5, 1.0 and 1.5 mg/kg body weight. The peripheral bloods were obtained at 0, 24, 48 and 72h after treatment. The frequencies of micronucleated reficulocytes(MNRET) in the MMC-treated groups increased dose-dependently, and showed a peak time at 48h after treatment. We also performed the sex differences of MNRET frequency in 0.5 mg/kg MMC treated group, and we observed no sex differences in this experiment. And we evaluated the usefulness of a direct acting clastogen, N-methyl-N-nitrosourea and a indirect acting clastogen, benzo(a) pyrene as the positive control in this supravital micronucleus test. They also caused a significant increase in MNRET frequencies. These results suggest that the supravital staining micronucleus test using MNRET can be useful tool to evalulate the quantitative and qualitative assessment of genotoxicity in vivo compared to classical in vivo micronucleus test using bone-marrow cells.

  • PDF