• 제목/요약/키워드: TEST-1

검색결과 60,126건 처리시간 0.073초

견인전동기 고정자 권선의 절연상태 분석 (Analysis of Insulation Condition in Traction Motor Stator Windings)

  • 김희동;박영
    • 한국전기전자재료학회논문지
    • /
    • 제20권7호
    • /
    • pp.631-635
    • /
    • 2007
  • Diagnostic, surge and ac breakdown tests are widely used to evaluate the insulation condition of stator winding in traction motor. Diagnostic test included ac current, tan delta and maximum partial discharge. The result of diagnostic test indicates that five kinds of stator windings are good condition. Surge test was peformed to confirm the healthy of turn insulation in stator windings. This test is very easy to detect the turn insulation failure between normal and defect stator windings. After completing the diagnostic test, ac breakdown test has conducted gradually increasing ac voltage, until the stator winding punctured. No. 5 stator windings failed near rated voltage of 18.9 kV The breakdown voltage of No. 1 stator windings was 13.0 kV The ac breakdown voltage of normal winding is about 1.45 times higher than that of defect windings. The failure was located in a line-end coil at the exit from the core slot.

추진인버터 시험을 위한 실시간 부하 시뮬레이터에 관한 연구 (Study on Real-Time Load Simulator for Testing Propulsion Inverter Test)

  • 김길동;신정렬;이우동;한석윤;박기준
    • 한국철도학회논문집
    • /
    • 제7권1호
    • /
    • pp.1-8
    • /
    • 2004
  • A newly-built inverter has to undergo a series of stress tests in the final stage of production line. This can be achieved by connecting it to a dynamometer consisting of a three-phase machine joined by a rigid shaft to a DC load machine. The latter is controlled to create some specific load characteristic needed for the test. In this paper a test method is proposed, in which no mechanical equipment is needed. The suggested test stand consists only of a inverter to be tested and a simulator converter. Both devices are connected back-to-back on the AC-side via smoothing reactors. The simulator operates in real-time as an equivalent load circuit, so that the device under test will only notice the behaviour of a three-phase machine under consideration of the load. In oder to prove rightness of the suggested test method, the simulation and actural experiment carried out emulation for a 2.2kW induction motor.

A Review of Structural Testing Methods for ASIC based AI Accelerators

  • Umair, Saeed;Irfan Ali, Tunio;Majid, Hussain;Fayaz Ahmed, Memon;Ayaz Ahmed, Hoshu;Ghulam, Hussain
    • International Journal of Computer Science & Network Security
    • /
    • 제23권1호
    • /
    • pp.103-111
    • /
    • 2023
  • Implementing conventional DFT solution for arrays of DNN accelerators having large number of processing elements (PEs), without considering architectural characteristics of PEs may incur overwhelming test overheads. Recent DFT based techniques have utilized the homogeneity and dataflow of arrays at PE-level and Core-level for obtaining reduction in; test pattern volume, test time, test power and ATPG runtime. This paper reviews these contemporary test solutions for ASIC based DNN accelerators. Mainly, the proposed test architectures, pattern application method with their objectives are reviewed. It is observed that exploitation of architectural characteristic such as homogeneity and dataflow of PEs/ arrays results in reduced test overheads.

MMC 기반 HVDC 전력변환기의 밸브 성능 시험회로 (Performance Test Circuit for a Valve of MMC Based HVDC Power Converter)

  • 배치환;조광래;김학수;노의철
    • 전력전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.76-81
    • /
    • 2023
  • A new test circuit for an MMC-based valve HVDC power converter is proposed. The proposed scheme satisfies the required clauses from IEC-62501. The valve test current contains second harmonic component and DC offset as well as a fundamental component that is quite similar to the real operating arm current of MMC based HVDC power system. The structure of the proposed test circuit is simple compared to conventional test circuits. Furthermore, the power supply voltage rating of the proposed test circuit is reduced dramatically around 20% of the conventional scheme with the same current rating. The validity of the proposed test circuit is verified through simulation and experimental results.

철도 차량용 PMSM 추진제어시스템 개발 및 시험 (PMSM Propulsion Control System Development and Test for Rolling Stock)

  • 노애숙;김태윤;정은성;한정수;이장무
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1845-1850
    • /
    • 2011
  • Permanent Magnet Synchronous Motor(PM motor) of Advanced EMU is the direct drive morot(DDM) without using reduction gear and Interior buried Permanent Magnet Synchronous Motor(IPMSM). Propulsion system for IPMSM control is composed 1C1M. 1C1M is good for each motor control and anti slip/slide. Propulsion control system have completed running test on field and reliability test is in progress.

  • PDF

TTA 시험$\cdot$인증서비스 - 소프트웨어 분야 -

  • 김혜경
    • TTA 저널
    • /
    • 통권86호
    • /
    • pp.89-93
    • /
    • 2003
  • TTA(한국정보통신기술협회)는 2003년 2월 28일, 품질인증 제품으로 ㈜하나디에스디의''라이프에듀빌더 v 1.0'', ㈜연성정보기술의''이메일플러스 v 3.0'', ㈜포스정보의''책꽂이KDC v 3.1'', ㈜켈코인의''챌린저 웹진 웹스쿨 v 3.0'' 등 4개의 제품에 대하여 Good Software 마크를 발급하였다. 그리고 2003년 3월 10일에 VeriTest-TTA 인증제품으로 (주)스페이스 인터내셔널의''CD Tower v 3.1''은 VeriTest-TTA Good Quality, Optimized Performance & Internationalized 마크를, ㈜포스데이터의''BizBinder v 1.0''은 VeriTest-TTA Good Quality & Optimized Performance 인증마크를 발급하였다. 본 고에서는 상위의 인증 획득한 제품에 대하여 소개하고자 한다.

  • PDF

도시형 자기부상열차의 성능시험 및 평가 (Performance Test and Evaluation of the Urban Transit Maglev)

  • 김국진;박계서;김남해;조흥제
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 창립기념 춘계학술대회 논문집
    • /
    • pp.485-493
    • /
    • 1998
  • The EMS/LIM driven system, called UTM-01 has been under development for LRT type urban transit applications. At the present time, the 1st vehicle of UTM-01 (a two vehicle system) is undergoing various tests on the 1.1km test track at the KIMM premises in Taejon. This paper describes the design, characteristics and test results of the Levitation /Guidance, the Propulsion/Braking System and the Leakage Flux for 1st vehicle of UTM-01.

  • PDF

비보강 조적조의 동적 거동 (Dynamic Response of Unreinforced Masonry Building)

  • 김남희;김재관
    • 한국지진공학회논문집
    • /
    • 제8권5호통권39호
    • /
    • pp.1-14
    • /
    • 2004
  • 본 연구는 우리나라에서 저층 주거용 건물로 널리 사용되고 있는 2층 규모의 비보강조적조 의 1/3 축소 모델에 대한 진동대 실험을 수행한 것이다. 본 연구의 주목적은 내진설계가 이루어지지 않은 조적조 건물의 내진거동을 살펴보고, 실험적 자료를 확보하는데 있다. 실험대상구조물은 횡방향으로는 대칭이지만 종방향으로는 약간 비대칭이고, 비교적 강한 다이어프램을 나타내는 콘크리트 슬래브로 되어있다. 실험체에 대한 모의 지진하중은 가속도를 점차 증가시켜가면서 종방향으로 가력하였다. 실험에서 얻은 구조물의 동적 응답자료는 진동대의 입력지진과 연관지어서 분석하였다. 더욱이 성능기초설계를 위한 성능수준을 제시하였다. 실험결과 1층에서의 전단파괴가 지배적이고 상부층은 강체거동을 보여주었다. 또한 균열 발생후에도 상당한 강도와 변형능력을 보유하고 있는 것으로 나타났다.

반도체 RAM의 결합고장을 검출하는 알고리듬 (Algorithms for Detecting Coupling Faults in Semiconductor RAM's)

  • 여정모;조상복
    • 전자공학회논문지A
    • /
    • 제30A권1호
    • /
    • pp.51-63
    • /
    • 1993
  • 기존의 알고리듬들이 완전히 검출하지 못하는 차수 2나 3의 연결된 2-결합고장을 검출하기 위하여 "알고리듬 다"가 제안되었다. 제한된 3-결합고장을 검출하는 "테스트1*", "테스트2*" 및 "알고리듬 라"가 제안되었다. "테스트1*"는 제한된 3-결합고장을 검출하는 측면에서 기존의 알고리듬들보다 시간복잡도가 감소되었다. "테스트2*" 및 "알고리듬 라"는 기존의 알고리듬들과 비교하여 시간복잡도가 감소되었고 개선된 고장 검출능력을 가진다. 그리고 요구하는 고장 검출정도에 따라 "알고리듬 라"를 순차적으로 수행시킬 수 있으며, 메모리를 병렬테스트하는 경우에 "알고리듬 라"를 수행시키면 시간복잡도가 상당히 개선된다. 비선형 번지순서를 발생시키고 두 번지부분으로 분할하여 반도체 RAM의 결합고장을 검출하는 MT(March Test)는 차수 3의 연결된 2-결합고장보다 복잡한 결합고장은 완전히 검출될 수 없다는 것이 입증되었다.

  • PDF

Ceriodaphnia dubia의 온도조절에 근거한 단기급성독성 조사법 (Rapid Bioassay Technique Based on Temperature Control of Ceriodaphnia dubia)

  • 박종호;이상일;조영옥;이원호;연익준;조규석
    • 한국수산과학회지
    • /
    • 제37권3호
    • /
    • pp.209-214
    • /
    • 2004
  • A method for rapid acute toxicity test based on temperature control of Ceriodaphnia dubia has been developed and evaluated. A new toxicity test based on temperature control (TTBTC) which are based on temperature control, was developed and compared for the adsorption of the better methodology for short-term toxicity screening. Initially, daphnid larval are exposed to toxicants and at the same time the temperature of the water bath containing media is increased to high temperature $(35.5^{\circ}C).$ After 1.25 hrs of contact time, the number of the daphnids, either living (no toxic effect) or dead (toxic effect), is counted by the naked eyes. Effect of exposure time on test sensitivity was not significantly different between 1 to 1.5 hr. Comparison of the rapid 1.25 hr acute toxicity test developed in this study and the standard 48 hr acute toxicity test using heavy metals, cyanide and pentachlorophenol indicated that the 1.25 hour test provides an acceptable level of sensitivity in toxicity test for C. dubia.